{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,25]],"date-time":"2026-07-25T05:30:53Z","timestamp":1784957453669,"version":"3.55.0"},"reference-count":16,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,1,7]],"date-time":"2021-01-07T00:00:00Z","timestamp":1609977600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2021,1,7]],"date-time":"2021-01-07T00:00:00Z","timestamp":1609977600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>The femoral component anteversion during surgery is traditionally assessed by a visual assessment of the surgeon and has proven to be imprecise. We sought to determine the accuracy of a digital protractor and a spirit level to measure the stem anteversion during cementless THA.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A prospective study was conducted among 107 patients (114 hips) who underwent primary cementless THA via posterolateral approach. A pipe with a spirit level was attached to the tibial tubercle and intermalleolar midpoint. While the leg was held perpendicularly to the floor, stem anteversion was estimated by 3 methods: method A by visual assessment; method B by a digital protractor alone; and method C by a digital protractor combined with a spirit level. The angles were compared with the true anteversion measured by postoperative CT scan.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The average anteversion by method C (22.8\u00b0 \u00b1 6.9\u00b0, range -2\u00b0 to 40\u00b0) was significantly lower than method A (24.6\u00b0 \u00b1 5.2\u00b0, range 0\u00b0 to 30\u00b0) (p=0.033), but not different from the true anteversion (22.1\u00b0 \u00b1 8.2\u00b0, range -5.4\u00b0 to 43.1\u00b0) (p=0.445). There were no significant differences between method B (23.2\u00b0 \u00b1 8.2\u00b0, range -4\u00b0 to 45\u00b0) and method A, C or the true anteversion. The mean deviation of the intraoperative estimation from the true anteversion was 0.8\u00b0 \u00b1 3.7\u00b0 (range -7.1\u00b0 to 8.0\u00b0) by method C; 1.2\u00b0 \u00b1 5.1\u00b0 (range -8.8\u00b0 to 14.3\u00b0) by method B; and 2.5\u00b0 \u00b1 7.4\u00b0 (range -19.0\u00b0 to 16.0\u00b0) by method A. Estimation error within 5\u00b0 was found in 107 hips (93.9%) with method C; 86 hips (75.4%) with method B; and 59 hips (51.8%) with method A.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Accurate estimation of stem anteversion during cementless THA can be determined intraoperatively by the use of a digital protractor and a spirit level.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Trial registration<\/jats:title>\n                    <jats:p>\n                      Thai Clinical Trials Registry (\n                      <jats:ext-link xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" ext-link-type=\"uri\" xlink:href=\"http:\/\/www.clinicaltrials.in.th\/index.php?tp=regtrials&amp;menu=trialsearch&amp;smenu=fulltext&amp;task=search&amp;task2=view1&amp;id=3375\">TCTR 20180326003<\/jats:ext-link>\n                      ). Registered on 20 March 2018. Retrospectively registered.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s13018-020-02183-7","type":"journal-article","created":{"date-parts":[[2021,1,7]],"date-time":"2021-01-07T15:10:28Z","timestamp":1610032228000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Accuracy of intraoperative estimation of femoral stem anteversion in cementless total hip arthroplasty by using a digital protractor and a spirit level"],"prefix":"10.1186","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3305-7591","authenticated-orcid":false,"given":"Anuwat","family":"Pongkunakorn","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nawakun","family":"Phetpangnga","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Narawit","family":"Kananai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,1,7]]},"reference":[{"key":"2183_CR1","doi-asserted-by":"publisher","first-page":"1315","DOI":"10.1016\/j.jbiomech.2005.03.008","volume":"39","author":"F Yoshimine","year":"2006","unstructured":"Yoshimine F. The safe-zones for combined cup and neck anteversions that fulfill the essential range of motion and their optimum combination in total hip replacements. J Biomech. 2006;39:1315\u201323. https:\/\/doi.org\/10.1016\/j.jbiomech.2005.03.008.","journal-title":"J Biomech."},{"key":"2183_CR2","doi-asserted-by":"publisher","first-page":"696","DOI":"10.1016\/j.arth.2005.11.008","volume":"21","author":"AP Wines","year":"2006","unstructured":"Wines AP, McNicol D. Computed tomography measurement of the accuracy of component version in total hip arthroplasty. J Arthroplasty. 2006;21:696\u2013701. https:\/\/doi.org\/10.1016\/j.arth.2005.11.008.","journal-title":"J Arthroplasty."},{"key":"2183_CR3","doi-asserted-by":"publisher","first-page":"119","DOI":"10.1007\/s11999-008-0598-4","volume":"467","author":"LD Dorr","year":"2009","unstructured":"Dorr LD, Malik A, Dastane M, Wan Z. Combined anteversion technique for total hip arthroplasty. Clin Orthop Relat Res. 2009;467:119\u201327. https:\/\/doi.org\/10.1007\/s11999-008-0598-4.","journal-title":"Clin Orthop Relat Res."},{"key":"2183_CR4","doi-asserted-by":"publisher","first-page":"2598","DOI":"10.2106\/JBJS.H.01225","volume":"91","author":"LD Dorr","year":"2009","unstructured":"Dorr LD, Wan Z, Malik A, Zhu J, Dastane M, Deshmane P. A comparison of surgeon estimation and computed tomographic measurement of femoral component anteversion in cementless total hip arthroplasty. J Bone Joint Surg Am. 2009;91:2598\u2013604.","journal-title":"J Bone Joint Surg Am."},{"key":"2183_CR5","doi-asserted-by":"publisher","first-page":"1648","DOI":"10.1016\/j.arth.2013.03.006","volume":"28","author":"M Hirata","year":"2013","unstructured":"Hirata M, Nakashima Y, Ohishi M, Hamai S, Hara D, Iwamoto Y. Surgeon error in performing intraoperative estimation of stem anteversion in cementless total hip arthroplasty. J Arthroplasty. 2013;28:1648\u201353. https:\/\/doi.org\/10.1016\/j.arth.2013.03.006.","journal-title":"J Arthroplasty."},{"key":"2183_CR6","doi-asserted-by":"publisher","first-page":"341","DOI":"10.1016\/j.otsr.2017.11.023","volume":"104","author":"YK Lee","year":"2018","unstructured":"Lee YK, Kim JW, Kim TY, Ha YC, Koo KH. Validity of the intra-operative measurement of stem anteversion and factors for the erroneous estimation in cementless total hip arthroplasty using postero-lateral approach. Orthop Traumatol Surg Res. 2018;104:341\u20136. https:\/\/doi.org\/10.1016\/j.otsr.2017.11.023.","journal-title":"Orthop Traumatol Surg Res."},{"key":"2183_CR7","doi-asserted-by":"publisher","first-page":"603","DOI":"10.1302\/0301-620X.97B5.34781","volume":"97-B","author":"G Meermans","year":"2015","unstructured":"Meermans G, Goetheer-Smits I, Lim RF, Van Doorn WJ, Kats J. The difference between the radiographic and the operative angle of inclination of the acetabular component in total hip arthroplasty: use of a digital protractor and the circumference of the hip to improve orientation. Bone Joint J. 2015;97-B:603\u201310. https:\/\/doi.org\/10.1302\/0301-620X.97B5.34781.","journal-title":"Bone Joint J."},{"key":"2183_CR8","doi-asserted-by":"publisher","first-page":"413","DOI":"10.1016\/j.arth.2005.04.015","volume":"21","author":"S Echeverri","year":"2006","unstructured":"Echeverri S, Leyvraz PF, Zambelli PY, Jolles BM. Reliable acetabular cup orientation with a new gravity-assisted guidance system. J Arthroplasty. 2006;21:413\u20139. https:\/\/doi.org\/10.1016\/j.arth.2005.04.015.","journal-title":"J Arthroplasty."},{"key":"2183_CR9","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1097\/BTO.0b013e318221e876","volume":"26","author":"WA Leone","year":"2011","unstructured":"Leone WA, Nevelos JE, Fonti F, Patel A. A new surgical instrument and technique designed to achieve more accurate component placement in total hip replacement. Tech Orthop. 2011;26:217\u201321.","journal-title":"Tech Orthop."},{"key":"2183_CR10","doi-asserted-by":"publisher","first-page":"862","DOI":"10.1302\/0301-620X.100B7.BJJ-2017-1607.R1","volume":"100-B","author":"B Darrith","year":"2018","unstructured":"Darrith B, Bell JA, Culvern C, Della Valle CJ. Can the use of an inclinometer improve the positioning of the acetabular component in total hip arthroplasty? Bone Joint J. 2018;100-B:862\u20136. https:\/\/doi.org\/10.1302\/0301-620X.100B7.BJJ-2017-1607.R1.","journal-title":"Bone Joint J."},{"key":"2183_CR11","doi-asserted-by":"publisher","first-page":"273","DOI":"10.1016\/j.joca.2009.10.005","volume":"18","author":"G McDaniel","year":"2010","unstructured":"McDaniel G, Mitchell KL, Charles C, Kraus VB. A comparison of five approaches to measurement of anatomic knee alignment from radiographs. Osteoarthritis Cartilage. 2010;18:273\u20137. https:\/\/doi.org\/10.1016\/j.joca.2009.10.005.","journal-title":"Osteoarthritis Cartilage."},{"key":"2183_CR12","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","volume":"15","author":"TK Koo","year":"2016","unstructured":"Koo TK, Li MY. A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med. 2016;15:155\u201363. https:\/\/doi.org\/10.1016\/j.jcm.2016.02.012.","journal-title":"J Chiropr Med."},{"key":"2183_CR13","first-page":"69","volume":"24","author":"MM Mukaka","year":"2012","unstructured":"Mukaka MM. Statistics corner: a guide to appropriate use of correlation coefficient in medical research. Malawi Med J. 2012;24:69\u201371.","journal-title":"Malawi Med J."},{"key":"2183_CR14","first-page":"314","volume":"7","author":"A Pongkunakorn","year":"2019","unstructured":"Pongkunakorn A, Palawong P, Chatmaitri S, Phetpangnga N. Use of a digital protractor and a spirit level to determine the intraoperative anteversion of femoral component during cemented hip hemiarthroplasty: a prospective clinical trial. Arch Bone Jt Surg. 2019;7:314\u201320.","journal-title":"Arch Bone Jt Surg."},{"key":"2183_CR15","doi-asserted-by":"publisher","first-page":"2288","DOI":"10.1007\/s00167-012-1987-5","volume":"21","author":"SM Howell","year":"2013","unstructured":"Howell SM, Chen J, Hull ML. Variability of the location of the tibial tubercle affects the rotational alignment of the tibial component in kinematically aligned total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2013;21:2288\u201395. https:\/\/doi.org\/10.1007\/s00167-012-1987-5.","journal-title":"Knee Surg Sports Traumatol Arthrosc."},{"key":"2183_CR16","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1097\/01.blo.0000170873.88306.56","volume":"439","author":"RA Siston","year":"2005","unstructured":"Siston RA, Daub AC, Giori NJ, Goodman SB, Delp SL. Evaluation of methods that locate the center of the ankle for computer-assisted total knee arthroplasty. Clin Orthop Relat Res. 2005;439:129\u201335.","journal-title":"Clin Orthop Relat Res."}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-020-02183-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s13018-020-02183-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-020-02183-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,1,7]],"date-time":"2021-01-07T15:42:11Z","timestamp":1610034131000},"score":1,"resource":{"primary":{"URL":"https:\/\/josr-online.biomedcentral.com\/articles\/10.1186\/s13018-020-02183-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1,7]]},"references-count":16,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["2183"],"URL":"https:\/\/doi.org\/10.1186\/s13018-020-02183-7","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-51288\/v1","asserted-by":"object"}]},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,1,7]]},"assertion":[{"value":"31 October 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 December 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 January 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The Research Ethics Committee of Lampang Hospital reviewed and approved this study (EC code: 042\/60). Written informed consent was obtained from all participants in the study. The procedures were in accordance with the ethical standards of the responsible committee on human experimentation and with the Declaration of Helsinki 2000.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"27"}}