{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,8]],"date-time":"2026-01-08T01:49:08Z","timestamp":1767836948810,"version":"3.49.0"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,7,3]],"date-time":"2021-07-03T00:00:00Z","timestamp":1625270400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,7,3]],"date-time":"2021-07-03T00:00:00Z","timestamp":1625270400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>When approaching a joint replacement procedure, pre-surgical planning is essential to predict an accurate estimation of implant size and position. There are currently two methods to achieve it, analog and digital. The present study aims to demonstrate how the hybrid technique is accurate and precise for pre-surgical planning in a non-cemented total hip replacement.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Concordance-type study is used against a gold standard, as well as inter- and intra-observer consistency evaluation of two orthopedic surgeons and two orthopedic surgery residents. Accuracy was calculated with the intra-class correlation coefficient (ICC). Afterwards, the same calculation was done considering a margin of error with one size more and one less.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Thirty-eight patients were included in the study: 19 women and 19 men. Twenty-two prostheses (57.89%) were right-sided and 16 were left (42.11%). Twelve prostheses (31.57%) were Stryker and 26 Johnson &amp; Johnson (68.43%). Acetabular cup correlation compared with the gold standard was moderate: ICC reported 0.45 (95% CI, 0.15\u20130.76). When adjusted by \u00b1 1 size, ICC was 0.48 (95% CI, 0.18\u20130.79). On the other hand, results from the femoral stem reported ICC 0.85 (95% CI, 0.07\u20130.98). When adjusted by \u00b1 1 size, ICC was 0.86 (95% CI, 0.06\u20130.99).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Hybrid templating is a reliable substitute for analog or digital planning. It is quick, inexpensive, accurate, and better results are observed in the femoral component regardless the level of expertise of the evaluator.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Level of evidence<\/jats:title>\n                <jats:p>Grade IV<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s13018-021-02584-2","type":"journal-article","created":{"date-parts":[[2021,7,3]],"date-time":"2021-07-03T12:02:36Z","timestamp":1625313756000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":14,"title":["Precision and accuracy of pre-surgical planning of non-cemented total hip replacement with calibrated digital images and acetates"],"prefix":"10.1186","volume":"16","author":[{"given":"Luis Fernando Useche","family":"G\u00f3mez","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4913-7764","authenticated-orcid":false,"given":"Hernando","family":"Gait\u00e1n-Lee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mar\u00eda Alejandra","family":"Duarte","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Patrick Dennis","family":"Halley","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alejandro Romero","family":"Jaramillo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Efraim Leal","family":"Garc\u00eda","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,7,3]]},"reference":[{"key":"2584_CR1","first-page":"3","volume":"49","author":"HR Blackley","year":"2000","unstructured":"Blackley HR, Howell GE, Rorabeck CH. Planning and management of the difficult primary hip replacement: preoperative planning and technical considerations. Instr Course Lect. 2000;49:3\u201311.","journal-title":"Instr Course Lect."},{"key":"2584_CR2","first-page":"636","volume":"29","author":"N Schiffers","year":"2000","unstructured":"Schiffers N, Schkommodau E, Portheine F, Radermacher K, Staudte HW. [Planning and performance of orthopedic surgery with the help of individual templates] (in German). Orthopade. 2000;29:636\u201340.","journal-title":"Orthopade"},{"issue":"3","key":"2584_CR3","doi-asserted-by":"publisher","first-page":"382","DOI":"10.1302\/0301-620X.80B3.0800382","volume":"80","author":"S Eggli","year":"1998","unstructured":"Eggli S, Pisan M, Muller ME. The value of preoperative planning for total hip arthroplasty. J Bone Joint Surg Br. 1998;80(3):382\u201390. https:\/\/doi.org\/10.1302\/0301-620X.80B3.0800382.","journal-title":"J Bone Joint Surg Br."},{"issue":"9 suppl","key":"2584_CR4","doi-asserted-by":"publisher","first-page":"s1037","DOI":"10.3928\/0147-7447-20050902-06","volume":"28","author":"WM Goldstein","year":"2005","unstructured":"Goldstein WM, Gordon A, Branson JJ. Leg length inequality in total hip arthroplasty. Orthopedics. 2005;28(9 suppl):s1037\u201340. https:\/\/doi.org\/10.3928\/0147-7447-20050902-06.","journal-title":"Orthopedics."},{"issue":"2","key":"2584_CR5","doi-asserted-by":"publisher","first-page":"191","DOI":"10.1016\/S0030-5898(05)70074-2","volume":"30","author":"FS Haddad","year":"1999","unstructured":"Haddad FS, Masri BA, Garbuz DS, Duncan CP. The prevention of periprosthetic fractures in total hip and knee arthroplasty. Orthop Clin North Am. 1999;30(2):191\u2013207. https:\/\/doi.org\/10.1016\/S0030-5898(05)70074-2.","journal-title":"Orthop Clin North Am."},{"key":"2584_CR6","first-page":"636","volume":"29","author":"N Schiffers","year":"2000","unstructured":"Schiffers N, Schkommodau E, Portheine F, Radermacher K, Staudte HW. Planning and performance of orthopedic surgery with the help of individual templates. Orthopade. 2000;29:636\u201340.","journal-title":"Orthopade"},{"key":"2584_CR7","doi-asserted-by":"publisher","first-page":"909","DOI":"10.1007\/s11999-008-0486-y","volume":"467","author":"JA Hendrikus","year":"2009","unstructured":"Hendrikus JA, Laumen M, Van Pul C, Van Mourik J. A New Digital Preoperative Planning Method for Total Hip Arthroplasties. Clin Orthop Relat Res. 2009;467:909\u201316.","journal-title":"Clin Orthop Relat Res"},{"issue":"4","key":"2584_CR8","doi-asserted-by":"publisher","first-page":"507","DOI":"10.1016\/S0883-5403(05)80153-6","volume":"10","author":"LW Carter","year":"1995","unstructured":"Carter LW, Stovall DO, Young TR. Determination of accuracy of preoperative templating of noncemented femoral prosthesis. J Arthroplasty. 1995;10(4):507\u201313. https:\/\/doi.org\/10.1016\/S0883-5403(05)80153-6.","journal-title":"J Arthroplasty."},{"key":"2584_CR9","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1016\/S0883-5403(07)80031-3","volume":"7","author":"JL Knight","year":"1992","unstructured":"Knight JL, Atwater RD. Preoperative planning for total hip arthroplasty: quantitating its utility and precision. J Arthroplasty. 1992;7:403\u20139. https:\/\/doi.org\/10.1016\/S0883-5403(07)80031-3.","journal-title":"J Arthroplasty."},{"issue":"1","key":"2584_CR10","doi-asserted-by":"publisher","first-page":"78","DOI":"10.1080\/00016470510030364","volume":"76","author":"R Diercks","year":"2005","unstructured":"The B, Diercks R, van Ooijen P, Van Horn JR. Comparison of analog and digital preoperative planning in total hip and knee arthroplasty. Acta Orthop. 2005;76(1):78\u201384. https:\/\/doi.org\/10.1080\/00016470510030364.","journal-title":"Acta Orthop."},{"issue":"5","key":"2584_CR11","doi-asserted-by":"publisher","first-page":"400","DOI":"10.1007\/s00423-003-0446-7","volume":"389","author":"M Viceconti","year":"2004","unstructured":"Viceconti M, Chiarini A, Testi D, Taddei F, Bordini B, Traina F, et al. New aspects and approaches in pre-operative planning of hip reconstruction: a computer simulation. Langenbecks Arch Surg. 2004;389(5):400\u20134. https:\/\/doi.org\/10.1007\/s00423-003-0446-7.","journal-title":"Langenbecks Arch Surg."},{"key":"2584_CR12","doi-asserted-by":"publisher","unstructured":"Petretta R, Strelzow J, Ohly NE, Misur P, Masri BA. Acetate templating on digital images is more accurate than computer-based templating for total hip arthroplasty. Clin Orthop Relat Res. 2015;473(12):3752\u20139. https:\/\/doi.org\/10.1007\/s11999-015-4321-y.","DOI":"10.1007\/s11999-015-4321-y"},{"key":"2584_CR13","volume-title":"F\u00edsica Universitaria. 11a edici\u00f3n ed. Vol. Volumen 2","author":"Z Sears","year":"2004","unstructured":"Sears, Z., Young, Freedman. , F\u00edsica Universitaria. 11a edici\u00f3n ed. Vol. Volumen 2. 2004: Pearson."},{"key":"2584_CR14","first-page":"595","volume-title":"Review principles of digital radiography with large-area , electronically readable detectors : a review of the basics radiology","author":"HG Chotas","year":"1999","unstructured":"Chotas HG, Iii JTD, Ravin CE. Review principles of digital radiography with large-area , electronically readable detectors : a review of the basics radiology, vol. 210; 1999. p. 595\u20139."},{"issue":"1","key":"2584_CR15","doi-asserted-by":"publisher","first-page":"136","DOI":"10.1302\/0301-620X.92B1.22257","volume":"92","author":"M Franken","year":"2010","unstructured":"Franken M, Grimm B, Heyligers I. A comparison of four systems for calibration when templating for total hip replacement with digital radiography. J Bone Joint Surg. Br. 2010;92(1):136\u201341.","journal-title":"J Bone Joint Surg. Br"},{"issue":"12","key":"2584_CR16","doi-asserted-by":"publisher","first-page":"1623","DOI":"10.1302\/0301-620X.90B12.20238","volume":"90","author":"A Kulkarni","year":"2008","unstructured":"Kulkarni A, Partington P, Kelly D, Muller S. Disc calibration for digital templating in hip replacement. J Bone Joint Surg Br. 2008;90(12):1623\u20136.","journal-title":"J Bone Joint Surg Br"},{"key":"2584_CR17","doi-asserted-by":"publisher","unstructured":"Wimsey S, Pickard R, Shaw G. Accurate scaling of digital radiographs of the pelvis. A prospective trial of two methods. J Bone Joint Surg Br. 2006;88(11):1508\u201312. https:\/\/doi.org\/10.1302\/0301-620X.88B11.18017.","DOI":"10.1302\/0301-620X.88B11.18017"},{"issue":"6","key":"2584_CR18","doi-asserted-by":"publisher","first-page":"390","DOI":"10.1007\/s00256-006-0106-4","volume":"35","author":"JA Davila","year":"2006","unstructured":"Davila JA, Kransdorf MJ, Duffy GP. Surgical planning of total hip arthroplasty: accuracy of computer-assisted EndoMap software in predicting component size. Skeletal Radiol. 2006;35(6):390\u20133. https:\/\/doi.org\/10.1007\/s00256-006-0106-4.","journal-title":"Skeletal Radiol."},{"issue":"7","key":"2584_CR19","doi-asserted-by":"publisher","first-page":"455","DOI":"10.5435\/00124635-200511000-00005","volume":"13","author":"AG Della Valle","year":"2005","unstructured":"Della Valle AG, Padgett D, Salvati EA. Preoperative planning for primary total hip arthroplasty. J Am Acad Orthop Surg. 2005;13(7):455\u201362.","journal-title":"J Am Acad Orthop Surg"},{"issue":"7","key":"2584_CR20","doi-asserted-by":"publisher","first-page":"778","DOI":"10.1016\/j.jclinepi.2011.10.019","volume":"65","author":"MA Rotondi","year":"2012","unstructured":"Rotondi MA, Donner A. A confidence interval approach to sample size estimation for interobserver agreement studies with multiple raters and outcomes. J Clin Epidemiol. 2012;65(7):778\u201384. https:\/\/doi.org\/10.1016\/j.jclinepi.2011.10.019 Epub 2012.","journal-title":"J Clin Epidemiol."},{"issue":"3","key":"2584_CR21","doi-asserted-by":"publisher","first-page":"247","DOI":"10.18597\/rcog.271","volume":"61","author":"\u00c9 Cort\u00e9s-Reyes","year":"2010","unstructured":"Cort\u00e9s-Reyes \u00c9, Rubio-Romero J, Gait\u00e1n-Duarte H. M\u00e9todos estad\u00edsticos de evaluaci\u00f3n de la concordancia y la reproducibilidad de pruebas diagn\u00f3sticas. Rev Colomb Obstet Ginecol. 2010;61(3):247\u201355 [cited 2020 July 03]. Available from: http:\/\/www.scielo.org.co\/scielo.php?script=sci_arttext&pid=S0034-74342010000300009&lng=en.","journal-title":"Rev Colomb Obstet Ginecol"},{"issue":"4","key":"2584_CR22","doi-asserted-by":"publisher","first-page":"529","DOI":"10.1016\/j.arth.2009.04.011","volume":"25","author":"P Gamble","year":"2010","unstructured":"Gamble P, de Beer J, Petruccelli D, Winemaker M. The accuracy of digital templating in uncemented total hip arthroplasty. J Arthroplasty. 2010;25(4):529\u201332. https:\/\/doi.org\/10.1016\/j.arth.2009.04.011.","journal-title":"J Arthroplasty."},{"key":"2584_CR23","doi-asserted-by":"publisher","first-page":"581","DOI":"10.1302\/0301-620X.88B5.17184","volume":"88","author":"MJ Oddy","year":"2006","unstructured":"Oddy MJ, Jones MJ, Pendegrass CJ, Pilling JR, Wimhurst JA. Assessment of reproducibility and accuracy in templating hybrid total hip arthroplasty using digital radiographs. J Bone Joint Surg Br. 2006;88:581\u20135.","journal-title":"J Bone Joint Surg Br."},{"issue":"3","key":"2584_CR24","doi-asserted-by":"publisher","first-page":"341","DOI":"10.1016\/j.otsr.2016.12.022","volume":"103","author":"Q Wang","year":"2017","unstructured":"Wang Q, Xiao J, Zhu L, Zhao X, Liu Z, Wang J, et al. Acetate templating on calibrated standing digital radiograph improves accuracy of preoperative templating for total hip arthroplasty. Orthop Traumatol Surg Res. 2017;103(3):341\u20137. https:\/\/doi.org\/10.1016\/j.otsr.2016.12.022.","journal-title":"Orthop Traumatol Surg Res."},{"issue":"1","key":"2584_CR25","doi-asserted-by":"publisher","first-page":"78","DOI":"10.1080\/00016470510030364","volume":"76","author":"B The","year":"2005","unstructured":"The B, Diercks RL, van Ooijen PM, van Horn JR. Comparison of analog and digital preoperative planning in total hip and knee arthroplasties. A prospective study of 173 hips and 65 total knees. Acta Orthop. 2005;76(1):78\u201384. https:\/\/doi.org\/10.1080\/00016470510030364.","journal-title":"Acta Orthop."}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-021-02584-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13018-021-02584-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-021-02584-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,7,3]],"date-time":"2021-07-03T12:07:20Z","timestamp":1625314040000},"score":1,"resource":{"primary":{"URL":"https:\/\/josr-online.biomedcentral.com\/articles\/10.1186\/s13018-021-02584-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,7,3]]},"references-count":25,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["2584"],"URL":"https:\/\/doi.org\/10.1186\/s13018-021-02584-2","relation":{},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,7,3]]},"assertion":[{"value":"6 May 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 June 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 July 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was submitted and approved by the ethics committee of the San Ignacio University Hospital and the Pontificia Universidad Javeriana. As it is a retrospective study, it does not require the informed consent of the participants upon admission.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"431"}}