{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,3]],"date-time":"2026-02-03T20:28:26Z","timestamp":1770150506467,"version":"3.49.0"},"reference-count":38,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,12,1]],"date-time":"2021-12-01T00:00:00Z","timestamp":1638316800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,12,14]],"date-time":"2021-12-14T00:00:00Z","timestamp":1639440000000},"content-version":"vor","delay-in-days":13,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>How to perform minimally invasive surgery for Tile C pelvic fracture is a major problem in clinical practice. We performed minimally invasive surgery for Tile C pelvic fracture using anterior ring internal fixator systems combined with sacroiliac screw fixation.\n<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Objective<\/jats:title>\n                <jats:p>To investigate the advantages and efficacy of anterior ring internal fixator systems combined with sacroiliac screw fixation in the treatment of Tile C pelvic fracture.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>From May 2017 to May 2020, 27 patients with Tile C pelvic fracture who underwent anterior ring internal fixator system combined with sacroiliac screw fixation (group A) and 21 patients with Tile C pelvic fracture who underwent plate-screw system combined with sacroiliac screw fixation (group B) were retrospectively analyzed.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>All 48 patients were followed up for more than 12\u00a0months, all fractures healed within 3\u20136\u00a0months. The operative time, intraoperative bleeding volume, blood transfusion volume, incision length, hospital stay, complication rate and Majeed score were 63.5\u2009\u00b1\u200910.7\u00a0min, 48.3\u2009\u00b1\u200927.9\u00a0ml, 0\u00a0ml, 4.5\u2009\u00b1\u20090.8\u00a0cm, 10.2\u2009\u00b1\u20092.7 d, 3.7% and 89.7\u2009\u00b1\u20094.6 points, respectively, in group A and 114.8\u2009\u00b1\u200919.1\u00a0min, 375\u2009\u00b1\u2009315.8\u00a0ml, 266.7\u2009\u00b1\u2009326.6\u00a0ml, 9.2\u2009\u00b1\u20093.9\u00a0cm, 20.9\u2009\u00b1\u20095.7 d, 23.8% and 88.7\u2009\u00b1\u20094.9 points, respectively, in group B. Combined excellent and good rates of the Matta evaluation and Majeed score were 100% in both groups. There were no significant differences in the Matta evaluation or Majeed score between the two groups (both <jats:italic>P<\/jats:italic>\u2009&gt;\u20090.05), whereas the operative time, intraoperative bleeding volume, blood transfusion volume, incision length and hospital stay were significantly less in group A (all <jats:italic>P<\/jats:italic>\u2009&lt;\u20090.05).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>An anterior ring internal fixator system combined with sacroiliac screw fixation can effectively treat Tile C pelvic fracture, and has advantages, including minimal invasiveness, simple operation, short operative time, safe and reliable features, fewer complications, short hospital stay and a good curative effect.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s13018-021-02863-y","type":"journal-article","created":{"date-parts":[[2021,12,14]],"date-time":"2021-12-14T10:02:55Z","timestamp":1639476175000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Clinical application of anterior ring internal fixator system combined with sacroiliac screw fixation in Tile C pelvic fracture treatment"],"prefix":"10.1186","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3729-2353","authenticated-orcid":false,"given":"Lin","family":"Liu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shicai","family":"Fan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Donggui","family":"Zeng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuhui","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hui","family":"Song","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Letian","family":"Zeng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dadi","family":"Jin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,12,14]]},"reference":[{"issue":"5","key":"2863_CR1","doi-asserted-by":"publisher","first-page":"269","DOI":"10.1097\/BOT.0b013e3182410577","volume":"26","author":"PA Cole","year":"2012","unstructured":"Cole PA, Gauger EM, Anavian J, Ly TV, Morgan RA, Heddings AA. Anterior pelvic external fixator versus subcutaneous internal fixator in the treatment of anterior ring pelvic fractures. J Orthop Trauma. 2012;26(5):269\u201377. https:\/\/doi.org\/10.1097\/BOT.0b013e3182410577.","journal-title":"J Orthop Trauma"},{"issue":"8","key":"2863_CR2","doi-asserted-by":"publisher","first-page":"2116","DOI":"10.1007\/s11999-012-2341-4","volume":"470","author":"TG Hiesterman","year":"2012","unstructured":"Hiesterman TG, Hill BW, Cole PA. Surgical technique: a percutaneous method of subcutaneous fixation for the anterior pelvic ring: the pelvic bridge. Clin Orthop Relat Res. 2012;470(8):2116\u201323. https:\/\/doi.org\/10.1007\/s11999-012-2341-4.","journal-title":"Clin Orthop Relat Res"},{"issue":"1","key":"2863_CR3","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1097\/BOT.0b013e318233b8a7","volume":"26","author":"R Vaidya","year":"2012","unstructured":"Vaidya R, Colen R, Vigdorchik J, Tonnos F, Sethi A. Treatment of unstable pelvic ring injuries with an internal anterior fixator and posterior fixation: initial clinical series. J Orthop Trauma. 2012;26(1):1\u20138. https:\/\/doi.org\/10.1097\/BOT.0b013e318233b8a7.","journal-title":"J Orthop Trauma"},{"issue":"5","key":"2863_CR4","doi-asserted-by":"publisher","first-page":"314","DOI":"10.1097\/BOT.0b013e318220bb22","volume":"26","author":"MJ Gardner","year":"2012","unstructured":"Gardner MJ, Mehta S, Mirza A, Ricci WM. Anterior pelvic reduction and fixation using a subcutaneous internal fixator. J Orthop Trauma. 2012;26(5):314\u201321. https:\/\/doi.org\/10.1097\/BOT.0b013e318220bb22.","journal-title":"J Orthop Trauma"},{"key":"2863_CR5","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1186\/1756-0500-7-133","volume":"7","author":"MJ Scheyerer","year":"2014","unstructured":"Scheyerer MJ, Zimmermann SM, Osterhoff G, Tiziani S, Simmen HP, Wanner GA, Werner CM. Anterior subcutaneous internal fixation for treatment of unstable pelvic fractures. BMC Res Notes. 2014;7:133. https:\/\/doi.org\/10.1186\/1756-0500-7-133.","journal-title":"BMC Res Notes"},{"key":"2863_CR6","doi-asserted-by":"publisher","first-page":"7285","DOI":"10.12659\/MSM.911009","volume":"24","author":"C Wang","year":"2018","unstructured":"Wang C, Liu H, Lin X, Chen J, Li T, Mai Q, Fan S. A single lateral rectus abdominis approach for the surgical treatment of complicated acetabular fractures: a clinical evaluation study of 59 patients. Med Sci Monit. 2018;24:7285\u201394. https:\/\/doi.org\/10.12659\/MSM.911009.","journal-title":"Med Sci Monit"},{"issue":"1","key":"2863_CR7","doi-asserted-by":"publisher","first-page":"29","DOI":"10.4055\/cios.2015.7.1.29","volume":"7","author":"HY Kim","year":"2015","unstructured":"Kim HY, Yang DS, Park CK, Choy WS. Modified Stoppa approach for surgical treatment of acetabular fracture. Clin Orthop Surg. 2015;7(1):29\u201338. https:\/\/doi.org\/10.4055\/cios.2015.7.1.29.","journal-title":"Clin Orthop Surg"},{"issue":"11","key":"2863_CR8","doi-asserted-by":"publisher","first-page":"3345","DOI":"10.1007\/s11999-014-3460-x","volume":"472","author":"MJ Isaacson","year":"2014","unstructured":"Isaacson MJ, Taylor BC, French BG, et al. Treatment of acetabulum fractures through the modified Stoppa approach: strategies and outcomes. Clin Orthop Relat Res. 2014;472(11):3345\u201352. https:\/\/doi.org\/10.1007\/s11999-014-3460-x.","journal-title":"Clin Orthop Relat Res"},{"issue":"3","key":"2863_CR9","doi-asserted-by":"publisher","first-page":"243","DOI":"10.4055\/cios.2016.8.3.243","volume":"8","author":"H-K Oh","year":"2016","unstructured":"Oh H-K, Choo SK, Kim J-J, et al. Stoppa approach for anterior plate fixation in unstable pelvic ring injury. Clin Orthop Surg. 2016;8(3):243\u20138. https:\/\/doi.org\/10.4055\/cios.2016.8.3.243.","journal-title":"Clin Orthop Surg"},{"key":"2863_CR10","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1097\/00003086-199608000-00016","volume":"329","author":"JM Matta","year":"1996","unstructured":"Matta JM, Tornetta P 3rd. Internal fixation of unstable pelvic ring injuries. Clin Orthop Relat Res. 1996;329:129\u201340. https:\/\/doi.org\/10.1097\/00003086-199608000-00016.","journal-title":"Clin Orthop Relat Res"},{"issue":"11","key":"2863_CR11","doi-asserted-by":"publisher","first-page":"1632","DOI":"10.2106\/00004623-199611000-00002","volume":"78","author":"JM Matta","year":"1996","unstructured":"Matta JM. Fractures of the acetabulum: accuracy of reduction and clinical results in patients managed operatively within three weeks after the injury. J Bone Jt Surg Am. 1996;78(11):1632\u201345.","journal-title":"J Bone Jt Surg Am"},{"issue":"2","key":"2863_CR12","doi-asserted-by":"publisher","first-page":"304","DOI":"10.1302\/0301-620X.71B2.2925751","volume":"71","author":"SA Majeed","year":"1989","unstructured":"Majeed SA. Grading the outcome of pelvic fractures. J Bone Jt Surg Br. 1989;71(2):304\u20136. https:\/\/doi.org\/10.1302\/0301-620X.71B2.2925751.","journal-title":"J Bone Jt Surg Br"},{"issue":"6","key":"2863_CR13","doi-asserted-by":"publisher","first-page":"889","DOI":"10.3171\/jns.1990.72.6.0889","volume":"72","author":"KJ Gibbons","year":"1990","unstructured":"Gibbons KJ, Soloniuk DS, Razack N. Neurological injury and patterns of sacral fractures. J Neurosurg. 1990;72(6):889\u201393. https:\/\/doi.org\/10.3171\/jns.1990.72.6.0889.","journal-title":"J Neurosurg"},{"issue":"5","key":"2863_CR14","doi-asserted-by":"publisher","first-page":"599","DOI":"10.1016\/j.injury.2004.11.016","volume":"36","author":"WT Mason","year":"2005","unstructured":"Mason WT, Khan SN, James CL, Chesser TJ, Ward AJ. Complications of temporary and definitive external fixation of pelvic ring injuries. Injury. 2005;36(5):599\u2013604. https:\/\/doi.org\/10.1016\/j.injury.2004.11.016.","journal-title":"Injury"},{"issue":"4","key":"2863_CR15","doi-asserted-by":"publisher","first-page":"431","DOI":"10.1016\/j.injury.2007.01.020","volume":"38","author":"E Hirvensalo","year":"2007","unstructured":"Hirvensalo E, Lindahl J, Kiljunen V. Modified and new approaches for pelvic and acetabular surgery. Injury. 2007;38(4):431\u201341. https:\/\/doi.org\/10.1016\/j.injury.2007.01.020.","journal-title":"Injury"},{"issue":"4","key":"2863_CR16","doi-asserted-by":"publisher","first-page":"330","DOI":"10.1007\/s00064-006-1181-3","volume":"18","author":"A G\u00e4nsslen","year":"2006","unstructured":"G\u00e4nsslen A, Krettek C. Retrograde transpubic screw fixation of transpubic instabilities. Oper Orthop Traumatol. 2006;18(4):330\u201340. https:\/\/doi.org\/10.1007\/s00064-006-1181-3 (English, German).","journal-title":"Oper Orthop Traumatol"},{"issue":"2","key":"2863_CR17","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1097\/BOT.0b013e318162ab6e","volume":"22","author":"AJ Starr","year":"2008","unstructured":"Starr AJ, Nakatani T, Reinert CM, Cederberg K. Superior pubic ramus fractures fixed with percutaneous screws: what predicts fixation failure? J Orthop Trauma. 2008;22(2):81\u20137. https:\/\/doi.org\/10.1097\/BOT.0b013e318162ab6e.","journal-title":"J Orthop Trauma"},{"issue":"7","key":"2863_CR18","doi-asserted-by":"publisher","first-page":"661","DOI":"10.1007\/s00113-009-1623-0","volume":"112","author":"M Kuttner","year":"2009","unstructured":"Kuttner M, Klaiber A, Lorenz T, F\u00fcchtmeier B, Neugebauer R. Der subkutane ventrale Fixateur interne (SVFI) am Becken [The pelvic subcutaneous cross-over internal fixator]. Unfallchirurg. 2009;112(7):661\u20139. https:\/\/doi.org\/10.1007\/s00113-009-1623-0 (German).","journal-title":"Unfallchirurg"},{"key":"2863_CR19","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1186\/1471-2474-15-111","volume":"15","author":"G Osterhoff","year":"2014","unstructured":"Osterhoff G, Tiziani S, Ferguson SJ, Spreiter G, Scheyerer MJ, Spinas GL, Wanner GA, Simmen HP, Werner CM. Mechanical testing of a device for subcutaneous internal anterior pelvic ring fixation versus external pelvic ring fixation. BMC Musculoskelet Disord. 2014;15:111. https:\/\/doi.org\/10.1186\/1471-2474-15-111.","journal-title":"BMC Musculoskelet Disord"},{"issue":"6","key":"2863_CR20","doi-asserted-by":"publisher","first-page":"665","DOI":"10.1007\/s00068-014-0482-8","volume":"41","author":"E Mcdonald","year":"2015","unstructured":"Mcdonald E, Theologis AA, Horst P, Kandemir U, Pekmezci M. When do anterior external or internal fixators provide additional stability in an unstable (Tile C) pelvic fracture? A biomechanical study. Eur J Trauma Emerg Surg. 2015;41(6):665\u201371. https:\/\/doi.org\/10.1007\/s00068-014-0482-8.","journal-title":"Eur J Trauma Emerg Surg"},{"issue":"1","key":"2863_CR21","doi-asserted-by":"publisher","first-page":"2578","DOI":"10.1038\/s41598-019-39068-7","volume":"9","author":"Y Yin","year":"2019","unstructured":"Yin Y, Luo J, Zhang R, Li S, Jiao Z, Zhang Y, Hou Z. Anterior subcutaneous internal fixator (INFIX) versus plate fixation for pelvic anterior ring fracture. Sci Rep. 2019;9(1):2578. https:\/\/doi.org\/10.1038\/s41598-019-39068-7.","journal-title":"Sci Rep"},{"key":"2863_CR22","doi-asserted-by":"publisher","first-page":"3764","DOI":"10.12659\/msm.900673","volume":"22","author":"C Bi","year":"2016","unstructured":"Bi C, Wang Q, Nagelli C, Wu J, Wang Q, Wang J. Treatment of unstable posterior pelvic ring fracture with pedicle screw-rod fixator versus locking compression plate: a comparative study. Med Sci Monit. 2016;22:3764\u201370. https:\/\/doi.org\/10.12659\/msm.900673.","journal-title":"Med Sci Monit"},{"issue":"5","key":"2863_CR23","doi-asserted-by":"publisher","first-page":"252","DOI":"10.1097\/BOT.0000000000000781","volume":"31","author":"R Vaidya","year":"2017","unstructured":"Vaidya R, Martin AJ, Roth M, Tonnos F, Oliphant B, Carlson J. Midterm radiographic and functional outcomes of the anterior subcutaneous internal pelvic fixator (INFIX) for pelvic ring injuries. J Orthop Trauma. 2017;31(5):252\u20139. https:\/\/doi.org\/10.1097\/BOT.0000000000000781.","journal-title":"J Orthop Trauma"},{"issue":"4","key":"2863_CR24","doi-asserted-by":"publisher","first-page":"e0215233","DOI":"10.1371\/journal.pone.0215233","volume":"14","author":"YT Tsai","year":"2019","unstructured":"Tsai YT, Hsu CL, Hung CC, Chou YC, Wu CC, Yeh TT. Conventional plate fixation versus minimally invasive modified pedicle screw-rod fixation for anterior pelvic ring fractures. PLoS ONE. 2019;14(4):e0215233. https:\/\/doi.org\/10.1371\/journal.pone.0215233.","journal-title":"PLoS ONE"},{"key":"2863_CR25","doi-asserted-by":"publisher","first-page":"e915886","DOI":"10.12659\/MSM.915886","volume":"26","author":"L Liu","year":"2020","unstructured":"Liu L, Fan S, Chen Y, Peng Y, Wen X, Zeng D, Song H, Jin D. Biomechanics of anterior ring internal fixation combined with sacroiliac screw fixation for Tile C3 pelvic fractures. Med Sci Monit. 2020;26:e915886. https:\/\/doi.org\/10.12659\/MSM.915886.","journal-title":"Med Sci Monit"},{"issue":"1","key":"2863_CR26","doi-asserted-by":"publisher","first-page":"225","DOI":"10.1186\/s13018-021-02348-y","volume":"16","author":"L Liu","year":"2021","unstructured":"Liu L, Zeng D, Fan S, Peng Y, Song H, Jin D, Zeng L. Biomechanical study of Tile C3 pelvic fracture fixation using an anterior internal system combined with sacroiliac screws. J Orthop Surg Res. 2021;16(1):225. https:\/\/doi.org\/10.1186\/s13018-021-02348-y.","journal-title":"J Orthop Surg Res"},{"issue":"8","key":"2863_CR27","doi-asserted-by":"publisher","first-page":"2124","DOI":"10.1007\/s11999-011-2233-z","volume":"470","author":"R Vaidya","year":"2012","unstructured":"Vaidya R, Kubiak EN, Bergin PF, Dombroski DG, Critchlow RJ, Sethi A, Starr AJ. Complications of anterior subcutaneous internal fixation for unstable pelvis fractures: a multicenter study. Clin Orthop Relat Res. 2012;470(8):2124\u201331. https:\/\/doi.org\/10.1007\/s11999-011-2233-z.","journal-title":"Clin Orthop Relat Res"},{"issue":"3","key":"2863_CR28","doi-asserted-by":"publisher","first-page":"138","DOI":"10.1097\/BOT.0000000000000193","volume":"29","author":"D Hesse","year":"2015","unstructured":"Hesse D, Kandmir U, Solberg B, Stroh A, Osgood G, Sems SA, Collinge CA. Femoral nerve palsy after pelvic fracture treated with INFIX: a case series. J Orthop Trauma. 2015;29(3):138\u201343. https:\/\/doi.org\/10.1097\/BOT.0000000000000193.","journal-title":"J Orthop Trauma"},{"issue":"17","key":"2863_CR29","doi-asserted-by":"publisher","first-page":"2312","DOI":"10.4103\/0366-6999.163377","volume":"128","author":"T Wu","year":"2015","unstructured":"Wu T, Chen W, Zhang Q, Zheng ZL, Lyu HZ, Cui YW, Cheng XD, Zhang YZ, Yang YJ. Biomechanical comparison of two kinds of internal fixation in a type C zone II pelvic fracture model. Chin Med J (Engl). 2015;128(17):2312\u20137. https:\/\/doi.org\/10.4103\/0366-6999.163377.","journal-title":"Chin Med J (Engl)"},{"issue":"2","key":"2863_CR30","doi-asserted-by":"publisher","first-page":"133","DOI":"10.4055\/cios.2016.8.2.133","volume":"8","author":"JJ Kim","year":"2016","unstructured":"Kim JJ, Jung CY, Eastman JG, Oh HK. Measurement of optimal insertion angle for iliosacral screw fixation using three-dimensional computed tomography scans. Clin Orthop Surg. 2016;8(2):133\u20139. https:\/\/doi.org\/10.4055\/cios.2016.8.2.133.","journal-title":"Clin Orthop Surg"},{"issue":"9","key":"2863_CR31","doi-asserted-by":"publisher","first-page":"1257","DOI":"10.1007\/s00402-013-1788-4","volume":"133","author":"J Zwingmann","year":"2013","unstructured":"Zwingmann J, Hauschild O, Bode G, S\u00fcdkamp NP, Schmal H. Malposition and revision rates of different imaging modalities for percutaneous iliosacral screw fixation following pelvic fractures: a systematic review and meta-analysis. Arch Orthop Trauma Surg. 2013;133(9):1257\u201365. https:\/\/doi.org\/10.1007\/s00402-013-1788-4.","journal-title":"Arch Orthop Trauma Surg"},{"issue":"4","key":"2863_CR32","doi-asserted-by":"publisher","first-page":"485","DOI":"10.1016\/j.otsr.2013.01.010","volume":"99","author":"M Boudissa","year":"2013","unstructured":"Boudissa M, Ruatti S, Maisse N, Arvin-Berod A, Trilling B, Long JA, Blaysat M, Tonetti J. Bilateral testicular dislocation with pelvic ring fracture: a case report and literature review. Orthop Traumatol Surg Res. 2013;99(4):485\u20137. https:\/\/doi.org\/10.1016\/j.otsr.2013.01.010.","journal-title":"Orthop Traumatol Surg Res"},{"issue":"6","key":"2863_CR33","doi-asserted-by":"publisher","first-page":"988","DOI":"10.1016\/j.injury.2014.01.015","volume":"45","author":"M Takao","year":"2014","unstructured":"Takao M, Nishii T, Sakai T, Yoshikawa H, Sugano N. Iliosacral screw insertion using CT-3D-fluoroscopy matching navigation. Injury. 2014;45(6):988\u201394. https:\/\/doi.org\/10.1016\/j.injury.2014.01.015.","journal-title":"Injury"},{"issue":"12","key":"2863_CR34","doi-asserted-by":"publisher","first-page":"707","DOI":"10.1097\/BOT.0000000000000092","volume":"28","author":"A Matityahu","year":"2014","unstructured":"Matityahu A, Kahler D, Krettek C, St\u00f6ckle U, Grutzner PA, Messmer P, Ljungqvist J, Gebhard F. Three-dimensional navigation is more accurate than two-dimensional navigation or conventional fluoroscopy for percutaneous sacroiliac screw fixation in the dysmorphic sacrum: a randomized multicenter study. J Orthop Trauma. 2014;28(12):707\u201310. https:\/\/doi.org\/10.1097\/BOT.0000000000000092.","journal-title":"J Orthop Trauma"},{"issue":"3","key":"2863_CR35","doi-asserted-by":"publisher","first-page":"392","DOI":"10.1002\/ca.22149","volume":"26","author":"R Vaidya","year":"2013","unstructured":"Vaidya R, Oliphant B, Jain R, Nasr K, Siwiec R, Onwudiwe N, Sethi A. The bikini area and bikini line as a location for anterior subcutaneous pelvic fixation: an anatomic and clinical investigation. Clin Anat. 2013;26(3):392\u20139. https:\/\/doi.org\/10.1002\/ca.22149.","journal-title":"Clin Anat"},{"issue":"8","key":"2863_CR36","doi-asserted-by":"publisher","first-page":"2111","DOI":"10.1007\/s11999-012-2287-6","volume":"470","author":"DJ Merriman","year":"2012","unstructured":"Merriman DJ, Ricci WM, McAndrew CM, Gardner MJ. Is application of an internal anterior pelvic fixator anatomically feasible? Clin Orthop Relat Res. 2012;470(8):2111\u20135. https:\/\/doi.org\/10.1007\/s11999-012-2287-6.","journal-title":"Clin Orthop Relat Res"},{"issue":"10","key":"2863_CR37","doi-asserted-by":"publisher","first-page":"2077","DOI":"10.1016\/j.injury.2016.08.006","volume":"47","author":"T Apivatthakakul","year":"2016","unstructured":"Apivatthakakul T, Rujiwattanapong N. Anterior subcutaneous pelvic internal fixator (INFIX), is it safe? A cadaveric study. Injury. 2016;47(10):2077\u201380. https:\/\/doi.org\/10.1016\/j.injury.2016.08.006.","journal-title":"Injury"},{"issue":"10","key":"2863_CR38","doi-asserted-by":"publisher","first-page":"2162","DOI":"10.1016\/j.injury.2017.08.047","volume":"48","author":"G Osterhoff","year":"2017","unstructured":"Osterhoff G, Aichner EV, Scherer J, Simmen HP, Werner CML, Feigl GC. Anterior subcutaneous internal fixation of the pelvis\u2014what rod-to-bone distance is anatomically optimal? Injury. 2017;48(10):2162\u20138. https:\/\/doi.org\/10.1016\/j.injury.2017.08.047.","journal-title":"Injury"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-021-02863-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13018-021-02863-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-021-02863-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,12,14]],"date-time":"2021-12-14T10:26:45Z","timestamp":1639477605000},"score":1,"resource":{"primary":{"URL":"https:\/\/josr-online.biomedcentral.com\/articles\/10.1186\/s13018-021-02863-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,12]]},"references-count":38,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["2863"],"URL":"https:\/\/doi.org\/10.1186\/s13018-021-02863-y","relation":{},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,12]]},"assertion":[{"value":"16 May 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 December 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 December 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was approved by the Institutional Review Board (approval number: LL-KT-2017145) of our institution. All patients provided written informed consent, and all procedures were in accordance with the Declaration of HELSINKI.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"715"}}