{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,28]],"date-time":"2026-08-28T12:43:55Z","timestamp":1787921035932,"version":"build-2784847793"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,1,11]],"date-time":"2022-01-11T00:00:00Z","timestamp":1641859200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,1,11]],"date-time":"2022-01-11T00:00:00Z","timestamp":1641859200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Good clinical outcomes for locking plates as an external fixator to treat tibial fractures have been reported. However, external locking plate fixation is still generally rarely performed. This study aimed to compare the stability of an external locking plate fixator with that of a conventional external fixator for extraarticular proximal tibial fractures using finite element analysis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Three models were constructed: (1) external locking plate fixation of proximal tibial fracture with lateral proximal tibial locking plate and 5-mm screws (ELP), (2) conventional external fixation of proximal tibial fracture with an 11-mm rod and 5-mm Schanz screws (EF-11), and (3) conventional external fixation of a proximal tibial fracture with a 7-mm rod and 5-mm Schanz screws (EF-7). The stress distribution, displacement at the fracture gap, and stiffness of the three finite element models at 30-, 40-, 50-, and 60-mm plate\u2013rod offsets from the lateral surface of the lateral condyle of the tibia were determined.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The conventional external fixator showed higher stiffness than the external locking plate fixator. In all models, the stiffness decreased as the distance of the plate\u2013rod from the bone surface increased. The maximum stiffness was 121.06\u00a0N\/mm in the EF-11 model with 30-mm tibia\u2013rod offset. In the EF-7 model group, the maximum stiffness was 40.00\u00a0N\/mm in the model with 30-mm tibia\u2013rod offset. In the ELP model group, the maximum stiffness was 35.79\u00a0N\/mm in the model with 30-mm tibia\u2013plate offset.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Finite element analysis indicated that external locking plate fixation is more flexible than conventional external fixation and can influence secondary bone healing. External locking plate fixation requires the placement of the plate as close as possible to the skin, which allows for a low-profile design because the increased distance from the plate to the bone can be too flexible for bone healing. Further experimental mechanical model tests are necessary to validate these finite element models, and further biological analysis is necessary to evaluate the effect of external locking plate fixation on fracture healing.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s13018-021-02907-3","type":"journal-article","created":{"date-parts":[[2022,1,11]],"date-time":"2022-01-11T08:02:53Z","timestamp":1641888173000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":24,"title":["Comparison between external locking plate fixation and conventional external fixation for extraarticular proximal tibial fractures: a finite element analysis"],"prefix":"10.1186","volume":"17","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2908-2508","authenticated-orcid":false,"given":"Dejan","family":"Bla\u017eevi\u0107","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jano\u0161","family":"Kodvanj","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Petra","family":"Adamovi\u0107","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dinko","family":"Vidovi\u0107","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zlatko","family":"Trobonja\u010da","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sre\u0107ko","family":"Sabali\u0107","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,1,11]]},"reference":[{"issue":"3","key":"2907_CR1","doi-asserted-by":"publisher","first-page":"501","DOI":"10.1007\/s00590-018-2320-x","volume":"29","author":"G Kalinterakis","year":"2019","unstructured":"Kalinterakis G, Koutras A, Syllaios A, Michalakeas N, Lytras D, Tsilikis I. The evolution and impact of the \u201cdamage control orthopedics\u201d paradigm in combat surgery: a review. Eur J Orthop Surg Traumatol. 2019;29(3):501\u20138.","journal-title":"Eur J Orthop Surg Traumatol"},{"issue":"9","key":"2907_CR2","doi-asserted-by":"publisher","first-page":"1923","DOI":"10.1007\/s00264-012-1585-7","volume":"36","author":"SA Tulner","year":"2012","unstructured":"Tulner SA, Strackee SD, Kloen P. Metaphyseal locking compression plate as an external fixator for the distal tibia. Int Orthop. 2012;36(9):1923\u20137.","journal-title":"Int Orthop"},{"issue":"49","key":"2907_CR3","doi-asserted-by":"publisher","first-page":"e9083","DOI":"10.1097\/MD.0000000000009083","volume":"96","author":"P Luo","year":"2017","unstructured":"Luo P, Xu D, Wu J, Chen YH. Locked plating as an external fixator in treating tibial fractures: a PRISMA-compliant systematic review. Medicine. 2017;96(49):e9083.","journal-title":"Medicine"},{"key":"2907_CR4","doi-asserted-by":"publisher","DOI":"10.1016\/j.otsr.2010.03.008","author":"P Cronier","year":"2010","unstructured":"Cronier P, Pietu G, Dujardin C, Bigorre N, Ducellier F, Gerard R. The concept of locking plates. Orthop Traumatol Surg Res. 2010. https:\/\/doi.org\/10.1016\/j.otsr.2010.03.008.","journal-title":"Orthop Traumatol Surg Res"},{"issue":"3","key":"2907_CR5","doi-asserted-by":"publisher","first-page":"383","DOI":"10.1007\/s00402-013-1916-1","volume":"134","author":"XS Qiu","year":"2014","unstructured":"Qiu XS, Yuan H, Zheng X, Wang JF, Xiong J, Chen YX. Locking plate as a definitive external fixator for treating tibial fractures with compromised soft tissue envelop. Arch Orthop Trauma Surg. 2014;134(3):383\u20138.","journal-title":"Arch Orthop Trauma Surg"},{"issue":"2","key":"2907_CR6","doi-asserted-by":"publisher","first-page":"154","DOI":"10.1111\/os.12101","volume":"6","author":"NA Ebraheim","year":"2014","unstructured":"Ebraheim NA, Carroll T, Hanna M, Zhang J, Liu J. Staged treatment of proximal tibial fracture using external locking compression plate. Orthop Surg. 2014;6(2):154\u20137.","journal-title":"Orthop Surg"},{"issue":"3","key":"2907_CR7","first-page":"614","volume":"71","author":"CH Ma","year":"2011","unstructured":"Ma CH, Tu YK, Yeh JH, Yang SC, Wu CH. Using external and internal locking plates in a two-stage protocol for treatment of segmental tibial fractures. J Trauma. 2011;71(3):614\u20139.","journal-title":"J Trauma"},{"issue":"1","key":"2907_CR8","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1186\/s12891-016-1384-1","volume":"18","author":"W Liu","year":"2017","unstructured":"Liu W, Yang L, Kong X, An L, Hong G, Guo Z, et al. Stiffness of the locking compression plate as an external fixator for treating distal tibial fractures: a biomechanics study. BMC Musculoskelet Disord. 2017;18(1):26.","journal-title":"BMC Musculoskelet Disord"},{"issue":"4","key":"2907_CR9","doi-asserted-by":"publisher","first-page":"216","DOI":"10.1302\/2046-3758.64.2000470","volume":"6","author":"BFH Ang","year":"2017","unstructured":"Ang BFH, Chen JY, Yew AKS, Chua SK, Chou SM, Chia SL, et al. Externalised locking compression plate as an alternative to the unilateral external fixator: a biomechanical comparative study of axial and torsional stiffness. Bone Joint Res. 2017;6(4):216\u201323.","journal-title":"Bone Joint Res"},{"issue":"2","key":"2907_CR10","doi-asserted-by":"publisher","first-page":"501","DOI":"10.1016\/j.injury.2016.11.031","volume":"48","author":"CH Ma","year":"2017","unstructured":"Ma CH, Wu CH, Jiang JR, Tu YK, Lin TS. Metaphyseal locking plate as an external fixator for open tibial fracture: clinical outcomes and biomechanical assessment. Injury. 2017;48(2):501\u20135.","journal-title":"Injury"},{"issue":"5","key":"2907_CR11","doi-asserted-by":"publisher","first-page":"587","DOI":"10.1123\/jab.28.5.587","volume":"28","author":"C Kanchanomai","year":"2012","unstructured":"Kanchanomai C, Phiphobmongkol V. Biomechanical evaluation of fractured tibia externally fixed with an LCP. J Appl Biomech. 2012;28(5):587\u201392.","journal-title":"J Appl Biomech"},{"issue":"Suppl 1","key":"2907_CR12","doi-asserted-by":"publisher","first-page":"S1","DOI":"10.1097\/BOT.0000000000001063","volume":"32","author":"EG Meinberg","year":"2018","unstructured":"Meinberg EG, Agel J, Roberts CS, Karam MD, Kellam JF. Fracture and dislocation classification compendium-2018. J Orthop Trauma. 2018;32(Suppl 1):S1\u2013170.","journal-title":"J Orthop Trauma"},{"key":"2907_CR13","doi-asserted-by":"publisher","DOI":"10.1016\/j.compbiomed.2020.104062","volume":"127","author":"AHA Wahab","year":"2020","unstructured":"Wahab AHA, Wui NB, Kadir MRA, Ramlee MH. Biomechanical evaluation of three different configurations of external fixators for treating distal third tibia fracture: Finite element analysis in axial, bending and torsion load. Comput Biol Med. 2020;127: 104062. https:\/\/doi.org\/10.1016\/j.compbiomed.2020.104062.","journal-title":"Comput Biol Med"},{"issue":"4","key":"2907_CR14","doi-asserted-by":"publisher","first-page":"664","DOI":"10.1053\/j.jfas.2019.09.006","volume":"59","author":"MH Ramlee","year":"2020","unstructured":"Ramlee MH, Gan HS, Daud SA, Wahab AA, Kadir MRA. Stress distributions and micromovement of fragment bone of pilon fracture treated with external fixator: a finite element analysis. J Foot Ankle Surg. 2020;59(4):664\u201372.","journal-title":"J Foot Ankle Surg"},{"issue":"15","key":"2907_CR15","doi-asserted-by":"publisher","first-page":"3282","DOI":"10.1016\/j.jbiomech.2008.08.013","volume":"41","author":"AD Heiner","year":"2008","unstructured":"Heiner AD. Structural properties of fourth-generation composite femurs and tibias. J Biomech. 2008;41(15):3282\u20134.","journal-title":"J Biomech"},{"issue":"10","key":"2907_CR16","doi-asserted-by":"publisher","first-page":"1322","DOI":"10.1016\/j.medengphy.2014.05.015","volume":"36","author":"MH Ramlee","year":"2014","unstructured":"Ramlee MH, Kadir MRA, Murali MR, Kamarul T. Finite element analysis of three commonly used external fixation devices for treating Type III pilon fractures. Med Eng Phys. 2014;36(10):1322\u201330.","journal-title":"Med Eng Phys"},{"issue":"12","key":"2907_CR17","doi-asserted-by":"publisher","first-page":"2634","DOI":"10.1016\/j.injury.2017.10.040","volume":"48","author":"JB Arnold","year":"2017","unstructured":"Arnold JB, Tu CG, Phan TM, Rickman M, Varghese VD, Thewlis D, Solomon LB. Characteristics of postoperative weight bearing and management protocols for tibial plateau fractures: findings from a scoping review. Injury. 2017;48(12):2634\u201342.","journal-title":"Injury"},{"issue":"8","key":"2907_CR18","doi-asserted-by":"publisher","first-page":"1093","DOI":"10.1302\/0301-620X.84B8.0841093","volume":"84","author":"SM Perren","year":"2002","unstructured":"Perren SM. Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology. J Bone Joint Surg Br. 2002;84(8):1093\u2013110.","journal-title":"J Bone Joint Surg Br"},{"issue":"3","key":"2907_CR19","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1097\/BOT.0b013e3181be6720","volume":"24","author":"TJ Lujan","year":"2010","unstructured":"Lujan TJ, Henderson CE, Madey SM, Fitzpatrick DC, Marsh JL, Bottlang M. Locked plating of distal femur fractures leads to inconsistent and asymmetric callus formation. J Orthop Trauma. 2010;24(3):156\u201362.","journal-title":"J Orthop Trauma"},{"issue":"7","key":"2907_CR20","doi-asserted-by":"publisher","first-page":"1652","DOI":"10.2106\/JBJS.I.01111","volume":"92","author":"M Bottlang","year":"2010","unstructured":"Bottlang M, Lesser M, Koerber J, Doornink J, Rechenberg BV, Augat P, et al. Far cortical locking can improve healing of fractures stabilized with locking plates. J Bone Joint Surg Am. 2010;92(7):1652\u201360.","journal-title":"J Bone Joint Surg Am"},{"issue":"1","key":"2907_CR21","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1097\/BOT.0b013e31818f8de4","volume":"23","author":"P Kloen","year":"2009","unstructured":"Kloen P. Supercutaneous plating: use of a locking compression plate as an external fixator. J Orthop Trauma. 2009;23(1):72\u20135.","journal-title":"J Orthop Trauma"},{"issue":"8","key":"2907_CR22","doi-asserted-by":"publisher","first-page":"494","DOI":"10.3928\/01477447-20150804-05","volume":"38","author":"J Zhang","year":"2015","unstructured":"Zhang J, Ebraheim NA, Li M, He X, Liu J. One-stage external fixation using a locking plate: experience in 116 tibial fractures. Orthopedics. 2015;38(8):494\u20137.","journal-title":"Orthopedics"},{"issue":"6","key":"2907_CR23","doi-asserted-by":"publisher","first-page":"1099","DOI":"10.1007\/s00590-015-1604-7","volume":"25","author":"J Zhang","year":"2015","unstructured":"Zhang J, Ebraheim N, Li M, He X, Schwind J, Liu J, et al. External fixation using locking plate in distal tibial fracture: a finite element analysis. Eur J Orthop Surg Traumatol. 2015;25(6):1099\u2013104.","journal-title":"Eur J Orthop Surg Traumatol"},{"issue":"8","key":"2907_CR24","doi-asserted-by":"publisher","first-page":"1097","DOI":"10.1016\/j.injury.2013.04.023","volume":"44","author":"CH Ma","year":"2013","unstructured":"Ma CH, Wu CH, Tu YK, Lin TS. Metaphyseal locking plate as a definitive external fixator for treating open tibial fractures\u2013clinical outcome and a finite element study. Injury. 2013;44(8):1097\u2013101.","journal-title":"Injury"},{"issue":"5","key":"2907_CR25","doi-asserted-by":"publisher","first-page":"461","DOI":"10.1016\/j.medengphy.2010.03.005","volume":"32","author":"K Karunratanakul","year":"2010","unstructured":"Karunratanakul K, Schrooten J, Oosterwyck HV. Finite element modelling of a unilateral fixator for bone reconstruction: Importance of contact settings. Med Eng Phys. 2010;32(5):461\u20137.","journal-title":"Med Eng Phys"},{"issue":"3","key":"2907_CR26","first-page":"262","volume":"16","author":"MH Ramlee","year":"2020","unstructured":"Ramlee MH. Finite element modelling and simulation for lower limb of human bone: a review. Mal J Med Health Sci. 2020;16(3):262\u201371.","journal-title":"Mal J Med Health Sci"},{"issue":"3","key":"2907_CR27","doi-asserted-by":"publisher","first-page":"257","DOI":"10.2106\/JBJS.20.00380","volume":"103","author":"V Glatt","year":"2021","unstructured":"Glatt V, Samchukov M, Cherkashin A, Iobst C. Reverse dynamization accelerates bone-healing in a large-animal osteotomy model. J Bone Joint Surg Am. 2021;103(3):257\u201363.","journal-title":"J Bone Joint Surg Am"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-021-02907-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13018-021-02907-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-021-02907-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,1,11]],"date-time":"2022-01-11T08:05:31Z","timestamp":1641888331000},"score":1,"resource":{"primary":{"URL":"https:\/\/josr-online.biomedcentral.com\/articles\/10.1186\/s13018-021-02907-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,1,11]]},"references-count":27,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["2907"],"URL":"https:\/\/doi.org\/10.1186\/s13018-021-02907-3","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-955261\/v1","asserted-by":"object"}]},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,1,11]]},"assertion":[{"value":"1 October 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 December 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 January 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"16"}}