{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T09:44:23Z","timestamp":1785577463945,"version":"3.56.0"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,2,5]],"date-time":"2022-02-05T00:00:00Z","timestamp":1644019200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,2,5]],"date-time":"2022-02-05T00:00:00Z","timestamp":1644019200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100012544","name":"China Medical University, Taiwan","doi-asserted-by":"publisher","award":["CMU110-S-05"],"award-info":[{"award-number":["CMU110-S-05"]}],"id":[{"id":"10.13039\/501100012544","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>For oblique metacarpal shaft fracture, if anatomical reduction is achieved through conservative cast immobilization rather than stable fixation, bone malrotation can easily occur, resulting in severe loss in hand prehensile function. However, whether bone plate fixation or only lag screw fixation is more preferable remains unclear. Few studies have evaluated whether screw fixation can provide biomechanical fixation strength similar to bone plate fixation.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Objective<\/jats:title>\n                <jats:p>We assessed the difference in fixation strength between fixtation with two lag screws and bone plate for oblique metacarpal shaft fractures.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Materials and methods<\/jats:title>\n                <jats:p>We created oblique metacarpal shaft fractures on 21 artificial bones and fixated them using (1) double lag screw (2LS group), (2) regular plate (RP group), or (3) locked plate (LP group). To obtain the force\u2013displacement data, a cantilever bending test was conducted for each specimen through a material testing machine. One-way analysis of variance and a Tukey test were conducted to compare the maximum fracture force and stiffness of the three fixation methods.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The maximum fracture force of the 2LS group (mean\u2009+\u2009SD: 153.6\u2009\u00b1\u200926.5\u00a0N) was significantly lower than that of the RP (211.6\u2009\u00b1\u200918.5\u00a0N) and LP (227.5\u2009\u00b1\u200910.0\u00a0N) groups (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001). However, no significant differences were discovered between the RP and LP groups. The coefficient of variation for the maximum fracture force of the 2LS group (17.3%) was more than twice as high as that of the RP (8.7%) and LP (4.4%) groups. In addition, the stiffness of the three fixation methods was similar.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>Compared with bone plate fixation, double lag screw fixation yielded slightly lower maximum bearable fracture force but similar stiffness. Therefore, this technique could be used for treating oblique metacarpal shaft fractures. However, using double lag screw fixation alone is technically demanding and requires considerable surgical experiences to produce consistent results.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s13018-022-02963-3","type":"journal-article","created":{"date-parts":[[2022,2,5]],"date-time":"2022-02-05T12:02:29Z","timestamp":1644062549000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Comparison of the fixation ability between lag screw and bone plate for oblique metacarpal shaft fracture"],"prefix":"10.1186","volume":"17","author":[{"given":"Yung-Cheng","family":"Chiu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tsung-Yu","family":"Ho","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cheng-En","family":"Hsu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yen-Nien","family":"Ting","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ming-Tzu","family":"Tsai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5533-2059","authenticated-orcid":false,"given":"Jui-Ting","family":"Hsu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,2,5]]},"reference":[{"issue":"1","key":"2963_CR1","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1177\/1558944718798854","volume":"14","author":"D Dreyfuss","year":"2019","unstructured":"Dreyfuss D, Allon R, Izacson N, Hutt D. A comparison of locking plates and intramedullary pinning for fixation of metacarpal shaft fractures. Hand. 2019;14(1):27\u201333.","journal-title":"Hand"},{"issue":"4","key":"2963_CR2","first-page":"279","volume":"21","author":"S Aykut","year":"2015","unstructured":"Aykut S, \u00d6zt\u00fcrk K, \u00d6zcan \u00c7, Demiro\u011flu M, G\u00fcr\u00fcn AU, \u00d6zden E. Results of surgical treatment in metacarpal shaft fractures using low profile mini plates. Turk J Trauma Emerg Surg. 2015;21(4):279\u201384.","journal-title":"Turk J Trauma Emerg Surg"},{"issue":"3","key":"2963_CR3","doi-asserted-by":"publisher","first-page":"256","DOI":"10.1111\/os.12195","volume":"7","author":"BD Curtis","year":"2015","unstructured":"Curtis BD, Fajolu O, Ruff ME, Litsky AS. Fixation of metacarpal shaft fractures: biomechanical comparison of intramedullary nail crossed K-wires and plate-screw constructs. Orthop Surg. 2015;7(3):256\u201360.","journal-title":"Orthop Surg"},{"issue":"5","key":"2963_CR4","doi-asserted-by":"publisher","first-page":"609","DOI":"10.1016\/S0266-7681(05)80120-2","volume":"20","author":"C Low","year":"1995","unstructured":"Low C, Wong H, Low Y, Wong H. A cadaver study of the effects of dorsal angulation and shortening of the metacarpal shaft on the extension and flexion force ratios of the index and little fingers. J Hand Surg Br Eur. 1995;20(5):609\u201313.","journal-title":"J Hand Surg Br Eur"},{"key":"2963_CR5","volume-title":"Rockwood and Green's fractures in adults","author":"JD Heckman","year":"2014","unstructured":"Heckman JD, McKee M, McQueen MM, Ricci W, Tornetta P III. Rockwood and Green\u2019s fractures in adults. Philadelphia: Lippincott Williams & Wilkins; 2014."},{"issue":"3","key":"2963_CR6","doi-asserted-by":"publisher","first-page":"287","DOI":"10.1016\/j.hcl.2006.02.018","volume":"22","author":"K Kawamura","year":"2006","unstructured":"Kawamura K, Chung KC. Fixation choices for closed simple unstable oblique phalangeal and metacarpal fractures. Hand Clin. 2006;22(3):287\u201395.","journal-title":"Hand Clin"},{"issue":"1","key":"2963_CR7","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12891-020-03840-y","volume":"22","author":"Y-C Chiu","year":"2021","unstructured":"Chiu Y-C, Ho T-Y, Ting Y-N, Tsai M-T, Huang H-L, Hsu C-E, Hsu J-T. Effect of oblique headless compression screw fixation for metacarpal shaft fracture: a biomechanical in vitro study. BMC Musculoskelet Disord. 2021;22(1):1\u20138.","journal-title":"BMC Musculoskelet Disord"},{"issue":"1","key":"2963_CR8","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s13018-021-02575-3","volume":"16","author":"Y-C Chiu","year":"2021","unstructured":"Chiu Y-C, Hsu C-E, Ho T-Y, Ting Y-N, Tsai M-T, Hsu J-T. Bone plate fixation ability on the dorsal and lateral sides of a metacarpal shaft transverse fracture. J Orthop Surg Res. 2021;16(1):1\u201310.","journal-title":"J Orthop Surg Res"},{"issue":"3","key":"2963_CR9","doi-asserted-by":"publisher","first-page":"264","DOI":"10.1016\/S0363-5023(82)80177-9","volume":"7","author":"JB Massengill","year":"1982","unstructured":"Massengill JB, Alexander H, Langrana N, Mylod A. A phalangeal fracture model\u2014quantitative analysis of rigidity and failure. J Hand Surg. 1982;7(3):264\u201370.","journal-title":"J Hand Surg"},{"issue":"2","key":"2963_CR10","doi-asserted-by":"publisher","first-page":"216","DOI":"10.1016\/S0363-5023(84)80145-8","volume":"9","author":"RK Vanik","year":"1984","unstructured":"Vanik RK, Weber RC, Matloub HS, Sanger JR, Gingrass RP. The comparative strengths of internal fixation techniques. J Hand Surg. 1984;9(2):216\u201321.","journal-title":"J Hand Surg"},{"issue":"4","key":"2963_CR11","doi-asserted-by":"publisher","first-page":"466","DOI":"10.1016\/S0363-5023(85)80067-8","volume":"10","author":"D Black","year":"1985","unstructured":"Black D, Mann R, Constine R, Daniels A. Comparison of internal fixation techniques in metacarpal fractures. J Hand Surg. 1985;10(4):466\u201372.","journal-title":"J Hand Surg"},{"issue":"1","key":"2963_CR12","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12891-020-03840-y","volume":"22","author":"Y-C Chiu","year":"2021","unstructured":"Chiu Y-C, Hsu C-E, Ho T-Y, Ting Y-N, Tsai M-T, Hsu J-T. Effect of a figure-of-eight cerclage wire with two Kirschner wires on fixation strength for transverse metacarpal shaft fractures: an in vitro study with artificial bone. BMC Musculoskelet Disord. 2021;22(1):1\u20139.","journal-title":"BMC Musculoskelet Disord"},{"key":"2963_CR13","doi-asserted-by":"crossref","unstructured":"Chiu YC, Hsu CE, Ho TY, Ting YN, Wei BH, Tsai MT, Hsu JT. Comparison of the fixation ability of headless compression screws and locking plate for metacarpal shaft transverse fracture. Medicine 2021;100:39(e27375).","DOI":"10.1097\/MD.0000000000027375"},{"issue":"1","key":"2963_CR14","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s13018-018-0890-2","volume":"13","author":"Y-C Chiu","year":"2018","unstructured":"Chiu Y-C, Tsai M-T, Hsu C-E, Hsu H-C, Huang H-L, Hsu J-T. New fixation approach for transverse metacarpal neck fracture: a biomechanical study. J Orthop Surg Res. 2018;13(1):1\u20137.","journal-title":"J Orthop Surg Res"},{"issue":"2","key":"2963_CR15","doi-asserted-by":"publisher","first-page":"375","DOI":"10.2106\/00004623-195840020-00010","volume":"40","author":"BC Kilbourne","year":"1958","unstructured":"Kilbourne BC, Paul EG. The use of small bone screws in the treatment of metacarpal, metatarsal, and phalangeal fractures. JBJS. 1958;40(2):375\u201383.","journal-title":"JBJS"},{"issue":"5","key":"2963_CR16","doi-asserted-by":"publisher","first-page":"381","DOI":"10.1097\/00005373-197105000-00002","volume":"11","author":"TP R\u00fcedi","year":"1971","unstructured":"R\u00fcedi TP, Burri C, Pfeiffer KM. Stable internal fixation of fractures of the hand. J Trauma Acute Care Surg. 1971;11(5):381\u20139.","journal-title":"J Trauma Acute Care Surg"},{"issue":"4","key":"2963_CR17","doi-asserted-by":"publisher","first-page":"487","DOI":"10.2106\/00004623-197658040-00010","volume":"58","author":"GP Crawford","year":"1976","unstructured":"Crawford GP. Screw fixation for certain fractures of the phalanges and metacarpals. JBJS. 1976;58(4):487\u201392.","journal-title":"JBJS"},{"issue":"10","key":"2963_CR18","doi-asserted-by":"publisher","first-page":"675","DOI":"10.1007\/s00402-004-0745-7","volume":"124","author":"C Trevisan","year":"2004","unstructured":"Trevisan C, Morganti A, Casiraghi A, Marinoni EC. Low-severity metacarpal and phalangeal fractures treated with miniature plates and screws. Arch Orthop Trauma Surg. 2004;124(10):675\u201380.","journal-title":"Arch Orthop Trauma Surg"},{"issue":"1","key":"2963_CR19","doi-asserted-by":"publisher","first-page":"124","DOI":"10.1016\/0266-7681_90_90068-F","volume":"15","author":"S Royle","year":"1990","unstructured":"Royle S. Rotational deformity following metacarpal fracture. J Hand Surg Br Eur. 1990;15(1):124\u20135.","journal-title":"J Hand Surg Br Eur"},{"issue":"3","key":"2963_CR20","doi-asserted-by":"publisher","first-page":"415","DOI":"10.1016\/j.cps.2019.02.011","volume":"46","author":"AH Taghinia","year":"2019","unstructured":"Taghinia AH, Talbot SG. Phalangeal and metacarpal fractures. Clin Plast Surg. 2019;46(3):415\u201323.","journal-title":"Clin Plast Surg"},{"key":"2963_CR21","doi-asserted-by":"crossref","unstructured":"Freeland AE, Jabaley ME, Hughes JL. Oblique and spiral metacarpal shaft fractures. In: Stable fixation of the hand and wrist. edn.. Springer; 1986: 55\u201357.","DOI":"10.1007\/978-1-4613-8640-7_17"},{"issue":"1","key":"2963_CR22","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12891-021-04200-0","volume":"22","author":"FG Dyrna","year":"2021","unstructured":"Dyrna FG, Avery DM, Yoshida R, Lam D, Oeckenp\u00f6hler S, Cote MP, Obopilwe E, Rodner CM, Mazzocca AD. Metacarpal shaft fixation: a biomechanical comparison of dorsal plating, lag screws, and headless compression screws. BMC Musculoskelet Disord. 2021;22(1):1\u20138.","journal-title":"BMC Musculoskelet Disord"},{"issue":"4","key":"2963_CR23","doi-asserted-by":"publisher","first-page":"311","DOI":"10.1007\/s11552-008-9108-0","volume":"3","author":"FA Liporace","year":"2008","unstructured":"Liporace FA, Kinchelow T, Gupta S, Kubiak EN, McDonnell M. Minifragment screw fixation of oblique metacarpal fractures: a biomechanical analysis of screw types and techniques. Hand. 2008;3(4):311\u20135.","journal-title":"Hand"},{"issue":"4","key":"2963_CR24","doi-asserted-by":"publisher","first-page":"454","DOI":"10.1007\/s11552-013-9544-3","volume":"8","author":"C Barr","year":"2013","unstructured":"Barr C, Behn AW, Yao J. Plating of metacarpal fractures with locked or nonlocked screws, a biomechanical study: how many cortices are really necessary? Hand. 2013;8(4):454\u20139.","journal-title":"Hand"},{"issue":"2","key":"2963_CR25","first-page":"111","volume":"22","author":"J Elfar","year":"2014","unstructured":"Elfar J, Stanbury S, Menorca RMG, Reed JD. Composite bone models in orthopaedic surgery research and education. J Am Acad Orthop Surg. 2014;22(2):111.","journal-title":"J Am Acad Orthop Surg"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-022-02963-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13018-022-02963-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-022-02963-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,2,5]],"date-time":"2022-02-05T12:08:45Z","timestamp":1644062925000},"score":1,"resource":{"primary":{"URL":"https:\/\/josr-online.biomedcentral.com\/articles\/10.1186\/s13018-022-02963-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,2,5]]},"references-count":25,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["2963"],"URL":"https:\/\/doi.org\/10.1186\/s13018-022-02963-3","relation":{},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,2,5]]},"assertion":[{"value":"30 December 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 January 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 February 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors have no financial or personal relationships with people or organizations that could be considered inappropriate for conducting this study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"72"}}