{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T13:45:01Z","timestamp":1740145501616,"version":"3.37.3"},"reference-count":18,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,7,15]],"date-time":"2022-07-15T00:00:00Z","timestamp":1657843200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,7,15]],"date-time":"2022-07-15T00:00:00Z","timestamp":1657843200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Purpose<\/jats:title>\n                <jats:p>To define the more stable knot tightening of a suture bridge when a single limb is preserved.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Five different sutures were tested: No. 2 Ethibond (Ethicon), Hi-Fi (ConMed Linvatec), Sutblue (SBM), SingleFlat (SBM), Hi-Fi Ribbon (ConMed Linvatec). A Surgeon\u2019s Knot was tied around a 30-mm circumference device, 6 times for each experiment. A single limb was kept to analyze failure modes of the knot. First step was to analyze which of pulling or sliding suture of the construct must be kept preventing failure of the knot. The cutting distance from the knot was evaluated at 1\u00a0mm and 4\u00a0mm with the suture loops pre-tensioned to 10\u00a0N and fixed to a second row after a 50\u00a0N tension load. The more stable construct was found: a single-pull load to 100\u00a0N and cyclic load (to 50\u00a0N for 30 cycles) experiments were conducted to evaluate the impact of cycling on knot loosening.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The more stable construct was obtained when the non-post limb was tensioned, and the post limb was cut at 4\u00a0mm (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.01). Loop circumference increased after each experiment for all tested sutures, independently of the preserved limb and the cutting distance. Elongation was significant for all tested sutures in all groups. Knot failure mostly occurred by slippage, only with tapes.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>A suture-bridge construct with the non-post limb preserved and the post limb cut at a 4\u00a0mm distance from the knot provides with the best security. Sutures are safer than tapes in suture bridge.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s13018-022-03180-8","type":"journal-article","created":{"date-parts":[[2022,7,15]],"date-time":"2022-07-15T08:02:54Z","timestamp":1657872174000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["A biomechanical study of the medial row tightening on stability of single stitch suture-bridge construct"],"prefix":"10.1186","volume":"17","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8782-9396","authenticated-orcid":false,"given":"Sharon","family":"Abihssira","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pierre-Alban","family":"Bouche","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Claire","family":"Cammas","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cl\u00e9ment","family":"Thirache","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Geoffroy","family":"Nourissat","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,7,15]]},"reference":[{"key":"3180_CR1","doi-asserted-by":"publisher","first-page":"227","DOI":"10.32098\/mltj.04.2015.01","volume":"05","author":"F Oliva","year":"2019","unstructured":"Oliva F, Piccirilli E, Bossa M, Giai Via A, Colombo A, Chillemi C, et al. IS Mu. LT-rotator cuff tears guidelines. Muscle Ligaments Tendons J. 2019;05:227. https:\/\/doi.org\/10.32098\/mltj.04.2015.01.","journal-title":"Muscle Ligaments Tendons J"},{"key":"3180_CR2","doi-asserted-by":"publisher","first-page":"1480","DOI":"10.1016\/j.jse.2013.06.020","volume":"22","author":"GM Gartsman","year":"2013","unstructured":"Gartsman GM, Drake G, Edwards TB, Elkousy HA, Hammerman SM, O\u2019Connor DP, et al. Ultrasound evaluation of arthroscopic full-thickness supraspinatus rotator cuff repair: single-row versus double-row suture bridge (transosseous equivalent) fixation. Results of a prospective, randomized study. J Shoulder Elb Surg. 2013;22:1480\u20137. https:\/\/doi.org\/10.1016\/j.jse.2013.06.020.","journal-title":"J Shoulder Elb Surg"},{"key":"3180_CR3","doi-asserted-by":"publisher","first-page":"2274","DOI":"10.1016\/j.arthro.2015.06.004","volume":"31","author":"J Hein","year":"2015","unstructured":"Hein J, Reilly JM, Chae J, Maerz T, Anderson K. Retear rates after arthroscopic single-row, double-row, and suture bridge rotator cuff repair at a minimum of 1 year of imaging follow-up: a systematic review. Arthrosc J Arthrosc Relat Surg. 2015;31:2274\u201381. https:\/\/doi.org\/10.1016\/j.arthro.2015.06.004.","journal-title":"Arthrosc J Arthrosc Relat Surg"},{"key":"3180_CR4","doi-asserted-by":"publisher","first-page":"377","DOI":"10.1016\/j.arthro.2012.11.008","volume":"29","author":"NA Mall","year":"2013","unstructured":"Mall NA, Lee AS, Chahal J, Van Thiel GS, Romeo AA, Verma NN, et al. Transosseous-equivalent rotator cuff repair: a systematic review on the biomechanical importance of tying the medial row. Arthrosc J Arthrosc Relat Surg. 2013;29:377\u201386. https:\/\/doi.org\/10.1016\/j.arthro.2012.11.008.","journal-title":"Arthrosc J Arthrosc Relat Surg"},{"key":"3180_CR5","doi-asserted-by":"publisher","first-page":"2559","DOI":"10.1007\/s00167-012-1922-9","volume":"20","author":"W Anderl","year":"2012","unstructured":"Anderl W, Heuberer PR, Laky B, Kriegleder B, Reihsner R, Eberhardsteiner J. Superiority of bridging techniques with medial fixation on initial strength. Knee Surg Sports Traumatol Arthrosc. 2012;20:2559\u201366. https:\/\/doi.org\/10.1007\/s00167-012-1922-9.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"3180_CR6","doi-asserted-by":"publisher","first-page":"489","DOI":"10.1016\/j.arthro.2004.03.005","volume":"20","author":"IKY Lo","year":"2004","unstructured":"Lo IKY, Burkhart SS, Chan KC, Athanasiou K. Arthroscopic knots: determining the optimal balance of loop security and knot security. Arthrosc J Arthrosc Relat Surg. 2004;20:489\u2013502. https:\/\/doi.org\/10.1016\/j.arthro.2004.03.005.","journal-title":"Arthrosc J Arthrosc Relat Surg"},{"key":"3180_CR7","doi-asserted-by":"publisher","first-page":"S120","DOI":"10.1016\/j.arthro.2009.12.009","volume":"26","author":"IKY Lo","year":"2010","unstructured":"Lo IKY, Ochoa E, Burkhart SS. A comparison of knot security and loop security in arthroscopic knots tied with newer high-strength suture materials. Arthrosc J Arthrosc Relat Surg. 2010;26:S120\u20136. https:\/\/doi.org\/10.1016\/j.arthro.2009.12.009.","journal-title":"Arthrosc J Arthrosc Relat Surg"},{"key":"3180_CR8","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1016\/j.otsr.2019.10.008","volume":"106","author":"S Erg\u00fcn","year":"2020","unstructured":"Erg\u00fcn S, Akg\u00fcn U, Karahan M. The effect of loop size on loop security and elongation of a knot. Orthop Traumatol Surg Res. 2020;106:35\u20138. https:\/\/doi.org\/10.1016\/j.otsr.2019.10.008.","journal-title":"Orthop Traumatol Surg Res"},{"key":"3180_CR9","doi-asserted-by":"publisher","first-page":"1277","DOI":"10.1016\/j.otsr.2018.08.010","volume":"104","author":"DC Meyer","year":"2018","unstructured":"Meyer DC, Bachmann E, L\u00e4dermann A, Lajtai G, Jentzsch T. The best knot and suture configurations for high-strength suture material. an in vitro biomechanical study. Orthop Traumatol Surg Res. 2018;104:1277\u201382. https:\/\/doi.org\/10.1016\/j.otsr.2018.08.010.","journal-title":"Orthop Traumatol Surg Res"},{"key":"3180_CR10","doi-asserted-by":"publisher","first-page":"192","DOI":"10.1016\/j.arthro.2008.09.010","volume":"25","author":"FA Barber","year":"2009","unstructured":"Barber FA, Herbert MA, Beavis RC. Cyclic load and failure behavior of arthroscopic knots and high strength sutures. Arthrosc J Arthrosc Relat Surg. 2009;25:192\u20139. https:\/\/doi.org\/10.1016\/j.arthro.2008.09.010.","journal-title":"Arthrosc J Arthrosc Relat Surg"},{"key":"3180_CR11","doi-asserted-by":"publisher","first-page":"138","DOI":"10.1016\/j.otsr.2012.09.020","volume":"99","author":"B Rousseau","year":"2013","unstructured":"Rousseau B, Diop A, Atlan F, Priam S, Aim F, Nourissat G, et al. Influence of prolonged immersion on the resistance of arthroscopy knots in biological media. Orthop Traumatol Surg Res. 2013;99:138\u201344. https:\/\/doi.org\/10.1016\/j.otsr.2012.09.020.","journal-title":"Orthop Traumatol Surg Res"},{"key":"3180_CR12","doi-asserted-by":"publisher","first-page":"901","DOI":"10.1177\/0363546507312640","volume":"36","author":"BT Busfield","year":"2008","unstructured":"Busfield BT, Glousman RE, McGarry MH, Tibone JE, Lee TQ. A biomechanical comparison of 2 technical variations of double-row rotator cuff fixation: the importance of medial row knots. Am J Sports Med. 2008;36:901\u20136. https:\/\/doi.org\/10.1177\/0363546507312640.","journal-title":"Am J Sports Med"},{"key":"3180_CR13","doi-asserted-by":"publisher","first-page":"835","DOI":"10.1177\/0363546509359679","volume":"38","author":"TR Duquin","year":"2010","unstructured":"Duquin TR, Buyea C, Bisson LJ. Which method of rotator cuff repair leads to the highest rate of structural healing?: A systematic review. Am J Sports Med. 2010;38:835\u201341. https:\/\/doi.org\/10.1177\/0363546509359679.","journal-title":"Am J Sports Med"},{"key":"3180_CR14","doi-asserted-by":"publisher","first-page":"128","DOI":"10.1067\/mse.2003.21","volume":"12","author":"CA Cummins","year":"2003","unstructured":"Cummins CA, Murrell GAC. Mode of failure for rotator cuff repair with suture anchors identified at revision surgery. J Shoulder Elb Surg. 2003;12:128\u201333. https:\/\/doi.org\/10.1067\/mse.2003.21.","journal-title":"J Shoulder Elb Surg"},{"key":"3180_CR15","doi-asserted-by":"publisher","first-page":"204","DOI":"10.1016\/j.arthro.2004.09.024","volume":"21","author":"HA Elkousy","year":"2005","unstructured":"Elkousy HA, Sekiya JK, Stabile KJ, McMahon PJ. A biomechanical comparison of arthroscopic sliding and sliding-locking knots. Arthrosc J Arthrosc Relat Surg. 2005;21:204\u201310. https:\/\/doi.org\/10.1016\/j.arthro.2004.09.024.","journal-title":"Arthrosc J Arthrosc Relat Surg"},{"key":"3180_CR16","doi-asserted-by":"publisher","first-page":"e873","DOI":"10.1016\/j.asmr.2021.01.029","volume":"3","author":"P Borbas","year":"2021","unstructured":"Borbas P, Fischer L, Ernstbrunner L, Hoch A, Bachmann E, Bouaicha S, et al. High-strength suture tapes are biomechanically stronger than high-strength sutures used in rotator cuff repair. Arthrosc Sports Med Rehabil. 2021;3:e873\u201380. https:\/\/doi.org\/10.1016\/j.asmr.2021.01.029.","journal-title":"Arthrosc Sports Med Rehabil"},{"key":"3180_CR17","doi-asserted-by":"publisher","first-page":"232596711770121","DOI":"10.1177\/2325967117701212","volume":"5","author":"RW Liu","year":"2017","unstructured":"Liu RW, Lam PH, Shepherd HM, Murrell GAC. Tape versus suture in arthroscopic rotator cuff repair: biomechanical analysis and assessment of failure rates at 6 months. Orthop J Sports Med. 2017;5:232596711770121. https:\/\/doi.org\/10.1177\/2325967117701212.","journal-title":"Orthop J Sports Med"},{"key":"3180_CR18","doi-asserted-by":"publisher","first-page":"603","DOI":"10.32098\/mltj.04.2020.07","volume":"10","author":"E Okay","year":"2020","unstructured":"Okay E, Bezer M. Rotator cuff repair with different suture materials results in different protein expressions with similar histological findings. An experimental study in rabbits. Muscle Ligaments Tendons J. 2020;10:603. https:\/\/doi.org\/10.32098\/mltj.04.2020.07.","journal-title":"Muscle Ligaments Tendons J"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-022-03180-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13018-022-03180-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-022-03180-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,7,15]],"date-time":"2022-07-15T08:11:50Z","timestamp":1657872710000},"score":1,"resource":{"primary":{"URL":"https:\/\/josr-online.biomedcentral.com\/articles\/10.1186\/s13018-022-03180-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7,15]]},"references-count":18,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["3180"],"URL":"https:\/\/doi.org\/10.1186\/s13018-022-03180-8","relation":{},"ISSN":["1749-799X"],"issn-type":[{"type":"electronic","value":"1749-799X"}],"subject":[],"published":{"date-parts":[[2022,7,15]]},"assertion":[{"value":"8 January 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 May 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 July 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This is a biomechanical study that was not done on human or animal subjects. Thus, it does not require an ethical approval.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"This is a biomechanical study that was not done on human or animal subjects. Thus, it does not require a consent to publish.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors have no relevant financial or non-financial interests to disclose.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"350"}}