{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,16]],"date-time":"2026-11-16T18:35:23Z","timestamp":1794854123190,"version":"4.9.1"},"reference-count":8,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,7,16]],"date-time":"2022-07-16T00:00:00Z","timestamp":1657929600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,7,16]],"date-time":"2022-07-16T00:00:00Z","timestamp":1657929600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Intertrochanteric hip fractures are common and devastating injuries, especially for the elderly. Surgical treatment is the optimal strategy for managing intertrochanteric fractures as it allows early rehabilitation and functional recovery. The relative effects of internal fixation strategies for intertrochanteric fracture after operation remain limited to relatively small studies which create uncertainty in attempts to establish evidence-based best practice.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>We conducted a systematic review and meta-analysis of randomised controlled trials (RCTs) and observational studies to assess the clinical effectiveness of two commonly used intramedullary devices: a twin-screw integrated cephalomedullary nail (InterTAN) versus a single-screw cephalomedullary nail (proximal femoral nail antirotation) in patients with intertrochanteric fractures. The following outcomes were considered: revisions, implant-related failures, non-unions, pain, Harris hip score and intra-operative outcomes. Odds ratios or mean differences with 95% confidence intervals in brackets are reported.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Six studies met the inclusion criteria: two randomised controlled trials and four observational studies enrolling 970 patients with a mean age of 77\u00a0years and 64% of patients being female. There was a statistically significant difference (<jats:italic>p<\/jats:italic> value\u2009&lt;\u20090.05) for revisions OR 0.27 (0.13\u20130.56), implant-related failures OR 0.16 (0.09\u20130.27) and proportion of patients complaining of pain OR 0.50 (0.34\u20130.74). There was no difference in non-unions and Harris hip score (<jats:italic>p<\/jats:italic> value\u2009&gt;\u20090.05). There was a significant difference in blood loss and fluoroscopy usage in favour of PFNA, while no difference in operating times was observed between the two devices.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Our meta-analysis suggests that a twin-screw integrated cephalomedullary nail (InterTAN) is clinically more effective when compared to a single-screw cephalomedullary nail proximal femoral nail antirotation resulting in fewer complications, fewer revisions and fewer patients complaining of pain. No difference has been established regarding non-unions and Harris hip score. Intra-operative outcomes favour PFNA with less blood loss and fluoroscopy usage. Further studies are warranted to explore the cost-effectiveness of these and other implants in managing patients with intertrochanteric fractures.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s13018-022-03244-9","type":"journal-article","created":{"date-parts":[[2022,7,16]],"date-time":"2022-07-16T09:03:14Z","timestamp":1657962194000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["In reply to the letter to the editor regarding \u201cComparison of a twin interlocking derotation and compression screw cephalomedullary nail (InterTAN) with a single screw derotation cephalomedullary nail (proximal femoral nail antirotation): a systematic review and meta-analysis for intertrochanteric fractures\u201d"],"prefix":"10.1186","volume":"17","author":[{"given":"Leo","family":"Nherera","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paul","family":"Trueman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alan","family":"Horner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tracy","family":"Watson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alan J.","family":"Johnstone","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,7,16]]},"reference":[{"key":"3244_CR1","doi-asserted-by":"publisher","first-page":"284","DOI":"10.1186\/s13018-022-03174-6","volume":"17","author":"H Hu","year":"2022","unstructured":"Hu H, Hui Y. Letter to the editor regarding \u201cComparison of a twin interlocking derotation and compression screw cephalomedullary nail (InterTAN) with a single screw derotation cephalomedullary nail (proximal femoral nail antirotation): a systematic review and meta-analysis for intertrochanteric fractures.\u201d J Ortho Surg Res. 2022;17:284.","journal-title":"J Ortho Surg Res"},{"issue":"1","key":"3244_CR2","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1186\/s13018-018-0749-6","volume":"13","author":"L Nherera","year":"2018","unstructured":"Nherera L, Trueman P, Horner A, et al. Comparison of a twin interlocking derotation and compression screw cephalomedullary nail (InterTAN) with a single screw derotation cephalomedullary nail (proximal femoral nail antirotation): a systematic review and meta-analysis for intertrochanteric fractures. J Orthop Surg Res. 2018;13(1):46.","journal-title":"J Orthop Surg Res"},{"key":"3244_CR3","doi-asserted-by":"publisher","DOI":"10.1038\/srep18195","author":"J Yu","year":"2015","unstructured":"Yu J, Zhang C, Li L, Kwong JSW, Xue L, Zeng X, Tang L, Li Y, Sunb X. Internal fixation treatments for intertrochanteric fracture: a systematic review and meta-analysis of randomized evidence. Sci Rep. 2015. https:\/\/doi.org\/10.1038\/srep18195.","journal-title":"Sci Rep"},{"key":"3244_CR4","doi-asserted-by":"publisher","first-page":"500","DOI":"10.1186\/s13018-020-02031-8","volume":"15","author":"W Liu","year":"2020","unstructured":"Liu W, Liu J, Ji G. Comparison of clinical outcomes with proximal femoral nail anti-rotation versus InterTAN nail for intertrochanteric femoral fractures: a meta-analysis. J Orthop Surg Res. 2020;15:500. https:\/\/doi.org\/10.1186\/s13018-020-02031-8.","journal-title":"J Orthop Surg Res"},{"key":"3244_CR5","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1186\/s13018-018-0852-8","volume":"13","author":"Z Hao","year":"2018","unstructured":"Hao Z, Wang X, Zhang X. Comparing surgical interventions for intertrochanteric hip fracture by blood loss and operation time: a network meta-analysis. J Orthop Surg Res. 2018;13:157. https:\/\/doi.org\/10.1186\/s13018-018-0852-8.","journal-title":"J Orthop Surg Res"},{"key":"3244_CR6","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1186\/s13018-020-01603-y","volume":"15","author":"N Wang","year":"2020","unstructured":"Wang N, Chen Y, Ji J, et al. The relationship between serum vitamin D and fracture risk in the elderly: a meta-analysis. J Orthop Surg Res. 2020;15:81. https:\/\/doi.org\/10.1186\/s13018-020-01603-y.","journal-title":"J Orthop Surg Res"},{"key":"3244_CR7","doi-asserted-by":"publisher","first-page":"377","DOI":"10.1186\/s13018-020-01904-2","volume":"15","author":"R Tian","year":"2020","unstructured":"Tian R, Zheng F, Zhao W, et al. Prevalence and influencing factors of nonunion in patients with tibial fracture: systematic review and meta-analysis. J Orthop Surg Res. 2020;15:377. https:\/\/doi.org\/10.1186\/s13018-020-01904-2.","journal-title":"J Orthop Surg Res"},{"key":"3244_CR8","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1186\/s13018-020-01624-7","volume":"15","author":"Z Yang","year":"2020","unstructured":"Yang Z, Ni J, Long Z, et al. Is hip fracture surgery safe for patients on antiplatelet drugs and is it necessary to delay surgery? A systematic review and meta-analysis. J Orthop Surg Res. 2020;15:105. https:\/\/doi.org\/10.1186\/s13018-020-01624-7.","journal-title":"J Orthop Surg Res"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-022-03244-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13018-022-03244-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-022-03244-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,7,16]],"date-time":"2022-07-16T09:16:09Z","timestamp":1657962969000},"score":1,"resource":{"primary":{"URL":"https:\/\/josr-online.biomedcentral.com\/articles\/10.1186\/s13018-022-03244-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7,16]]},"references-count":8,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["3244"],"URL":"https:\/\/doi.org\/10.1186\/s13018-022-03244-9","relation":{},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,7,16]]},"assertion":[{"value":"21 June 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 July 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 July 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable as this article does not contain any studies with human participants or animals performed by any of the authors.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"LN & PT are employees of Smith\u2009+\u2009Nephew (S\u2009+\u2009N). AH is a former employee of S\u2009+\u2009N. TW and AJ have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"354"}}