{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,26]],"date-time":"2026-10-26T20:24:46Z","timestamp":1793046286537,"version":"4.5.0"},"reference-count":41,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,8,8]],"date-time":"2022-08-08T00:00:00Z","timestamp":1659916800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,8,8]],"date-time":"2022-08-08T00:00:00Z","timestamp":1659916800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Coronal alignment after total knee arthroplasty (TKA) would influence the implant survival. Coronal alignment could be measured on short and full-length X-rays. The goal of the current study was to assess the correlation of short and full-length X-rays to accurate prediction of the true Hip-Knee-Ankle alignment after TKA in the Iranian population.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Lateral distal femoral and medial proximal tibial angles, FTA, HKA, in 180 Iranian patients (243 knees without extra-articular deformities) were measured and compared on short and full-length standing X-rays of primary TKA pre\/postoperatively.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The correlation between the preoperative FTA-short and FTA-long, FTA-short and HKA, and FTA-long and HKA values in degrees were fair, good and good (<jats:italic>r<\/jats:italic>\u2009=\u20090.64) (<jats:italic>r<\/jats:italic>\u2009=\u20090.73), (<jats:italic>r<\/jats:italic>\u2009=\u20090.76), respectively. This correlation for postoperative aMPTA and mMPTA (<jats:italic>r<\/jats:italic>\u2009=\u20090.73), and FTA-short and HKA (<jats:italic>r<\/jats:italic>\u2009=\u20090.76) values were good and significant (<jats:italic>P<\/jats:italic>\u2009=\u20090.001). Also, assessing coronal alignment based on short and full-length measurements would result in varying pre\/postoperative alignments (varus, neutral and valgus).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>Full length X-rays could not be replaced by short knee X-rays to asses true coronal alignment in TKA; considerable portion of our cases were missorted as varus, neutral or valgus based on the FTA versus the HKA. Intraoperative fixed 5\u00b0 valgus angle cut of distal femur did not result in postoperative favorable neutral alignment in all cases.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Level of evidence<\/jats:title>\n                <jats:p>IV.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s13018-022-03246-7","type":"journal-article","created":{"date-parts":[[2022,8,8]],"date-time":"2022-08-08T07:04:10Z","timestamp":1659942250000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Correlation of short knee and full-length X-rays in evaluating coronal plane alignment in total knee arthroplasty"],"prefix":"10.1186","volume":"17","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3631-1305","authenticated-orcid":false,"given":"Seyyed-Morteza","family":"Kazemi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8975-3951","authenticated-orcid":false,"given":"Seyyed-Mohammad","family":"Qoreishi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arash","family":"Maleki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Reza","family":"Minaei-Noshahr","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6640-2983","authenticated-orcid":false,"given":"Seyyed-Mohsen","family":"Hosseininejad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,8,8]]},"reference":[{"issue":"5","key":"3246_CR1","doi-asserted-by":"publisher","first-page":"639","DOI":"10.1007\/s00264-007-0391-0","volume":"32","author":"SS Morgan","year":"2008","unstructured":"Morgan SS, Bonshahi A, Pradhan N, Gregory A, Gambhir A, Porter M. The influence of postoperative coronal alignment on revision surgery in total knee arthroplasty. Int Orthop. 2008;32(5):639\u201342.","journal-title":"Int Orthop"},{"issue":"8","key":"3246_CR2","doi-asserted-by":"publisher","first-page":"2663","DOI":"10.1007\/s00167-015-3781-7","volume":"24","author":"H-x Liu","year":"2016","unstructured":"Liu H-x, Shang P, Ying X-Z, Zhang Y. Shorter survival rate in varus-aligned knees after total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2016;24(8):2663\u201371.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"2","key":"3246_CR3","doi-asserted-by":"publisher","first-page":"379","DOI":"10.1007\/s00264-013-2097-9","volume":"38","author":"Y-H Kim","year":"2014","unstructured":"Kim Y-H, Park J-W, Kim J-S, Park S-D. The relationship between the survival of total knee arthroplasty and postoperative coronal, sagittal and rotational alignment of knee prosthesis. Int Orthop. 2014;38(2):379\u201385.","journal-title":"Int Orthop"},{"issue":"6","key":"3246_CR4","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1016\/j.arth.2009.04.034","volume":"24","author":"DM Fang","year":"2009","unstructured":"Fang DM, Ritter MA, Davis KE. Coronal alignment in total knee arthroplasty: just how important is it? J Arthroplasty. 2009;24(6):39\u201343.","journal-title":"J Arthroplasty"},{"issue":"9","key":"3246_CR5","doi-asserted-by":"publisher","first-page":"1217","DOI":"10.1302\/0301-620X.93B9.26573","volume":"93","author":"T Bonner","year":"2011","unstructured":"Bonner T, Eardley W, Patterson P, Gregg P. The effect of post-operative mechanical axis alignment on the survival of primary total knee replacements after a follow-up of 15 years. J Bone Joint Surg Br. 2011;93(9):1217\u201322.","journal-title":"J Bone Joint Surg Br"},{"issue":"3","key":"3246_CR6","doi-asserted-by":"publisher","first-page":"398","DOI":"10.1002\/art.22618","volume":"57","author":"SN Issa","year":"2007","unstructured":"Issa SN, Dunlop D, Chang A, Song J, Prasad PV, Guermazi A, et al. Full-limb and knee radiography assessments of varus-valgus alignment and their relationship to osteoarthritis disease features by magnetic resonance imaging. Arthritis Care Res. 2007;57(3):398\u2013406.","journal-title":"Arthritis Care Res"},{"issue":"4","key":"3246_CR7","doi-asserted-by":"publisher","first-page":"878","DOI":"10.1016\/j.arth.2015.08.015","volume":"31","author":"A Park","year":"2016","unstructured":"Park A, Stambough JB, Nunley RM, Barrack RL, Nam D. The inadequacy of short knee radiographs in evaluating coronal alignment after total knee arthroplasty. J Arthroplasty. 2016;31(4):878\u201382.","journal-title":"J Arthroplasty"},{"issue":"12","key":"3246_CR8","doi-asserted-by":"publisher","first-page":"2143","DOI":"10.2106\/JBJS.I.01398","volume":"92","author":"S Parratte","year":"2010","unstructured":"Parratte S, Pagnano MW, Trousdale RT, Berry DJ. Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements. JBJS. 2010;92(12):2143\u20139.","journal-title":"JBJS"},{"issue":"2","key":"3246_CR9","doi-asserted-by":"publisher","first-page":"126","DOI":"10.2106\/JBJS.K.00607","volume":"95","author":"MA Ritter","year":"2013","unstructured":"Ritter MA, Davis KE, Davis P, Farris A, Malinzak RA, Berend ME, et al. Preoperative malalignment increases risk of failure after total knee arthroplasty. JBJS. 2013;95(2):126\u201331.","journal-title":"JBJS"},{"issue":"1","key":"3246_CR10","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1007\/s11999-011-1936-5","volume":"470","author":"J Bellemans","year":"2012","unstructured":"Bellemans J, Colyn W, Vandenneucker H, Victor J. The Chitranjan Ranawat Award: is neutral mechanical alignment normal for all patients?: the concept of constitutional varus. Clin Orthopaedics Relat Res. 2012;470(1):45\u201353.","journal-title":"Clin Orthopaedics Relat Res"},{"issue":"4","key":"3246_CR11","doi-asserted-by":"publisher","first-page":"591","DOI":"10.1016\/j.arth.2010.05.008","volume":"26","author":"JB Meding","year":"2011","unstructured":"Meding JB, Berend ME, Ritter MA, Galley MR, Malinzak RA. Intramedullary vs extramedullary femoral alignment guides: a 15-year follow-up of survivorship. J Arthroplasty. 2011;26(4):591\u20135.","journal-title":"J Arthroplasty"},{"issue":"17","key":"3246_CR12","doi-asserted-by":"publisher","first-page":"1588","DOI":"10.2106\/JBJS.J.00772","volume":"93","author":"MA Ritter","year":"2011","unstructured":"Ritter MA, Davis KE, Meding JB, Pierson JL, Berend ME, Malinzak RA. The effect of alignment and BMI on failure of total knee replacement. JBJS. 2011;93(17):1588\u201396.","journal-title":"JBJS"},{"issue":"2","key":"3246_CR13","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1016\/j.knee.2008.10.003","volume":"16","author":"TM van Raaij","year":"2009","unstructured":"van Raaij TM, Brouwer RW, Reijman M, Bierma-Zeinstra SM, Verhaar JA. Conventional knee films hamper accurate knee alignment determination in patients with varus osteoarthritis of the knee. Knee. 2009;16(2):109\u201311.","journal-title":"Knee"},{"issue":"4","key":"3246_CR14","doi-asserted-by":"publisher","first-page":"695","DOI":"10.1016\/j.arth.2014.11.024","volume":"30","author":"RB Abu-Rajab","year":"2015","unstructured":"Abu-Rajab RB, Deakin AH, Kandasami M, McGlynn J, Picard F, Kinninmonth AW. Hip\u2013knee\u2013ankle radiographs are more appropriate for assessment of post-operative mechanical alignment of total knee arthroplasties than standard AP knee radiographs. J Arthroplasty. 2015;30(4):695\u2013700.","journal-title":"J Arthroplasty"},{"issue":"1","key":"3246_CR15","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1016\/j.knee.2008.07.007","volume":"16","author":"AN Colebatch","year":"2009","unstructured":"Colebatch AN, Hart DJ, Zhai G, Williams F, Spector TD, Arden NK. Effective measurement of knee alignment using AP knee radiographs. Knee. 2009;16(1):42\u20135.","journal-title":"Knee"},{"issue":"2","key":"3246_CR16","doi-asserted-by":"publisher","first-page":"306","DOI":"10.1002\/art.21836","volume":"55","author":"RS Hinman","year":"2006","unstructured":"Hinman RS, May RL, Crossley KM. Is there an alternative to the full-leg radiograph for determining knee joint alignment in osteoarthritis? Arthritis Care Res Off J Am College Rheumatol. 2006;55(2):306\u201313.","journal-title":"Arthritis Care Res Off J Am College Rheumatol"},{"issue":"4","key":"3246_CR17","doi-asserted-by":"publisher","first-page":"530","DOI":"10.1016\/j.joca.2009.12.004","volume":"18","author":"C Chang","year":"2010","unstructured":"Chang C, Choi J-Y, Koh I, Seo E, Seong S, Kim T. What should be considered in using standard knee radiographs to estimate mechanical alignment of the knee? Osteoarthritis Cartilage. 2010;18(4):530\u20138.","journal-title":"Osteoarthritis Cartilage"},{"issue":"2","key":"3246_CR18","doi-asserted-by":"publisher","first-page":"120","DOI":"10.1016\/j.knee.2011.02.001","volume":"19","author":"AH Deakin","year":"2012","unstructured":"Deakin AH, Basanagoudar PL, Nunag P, Johnston AT, Sarungi M. Natural distribution of the femoral mechanical\u2013anatomical angle in an osteoarthritic population and its relevance to total knee arthroplasty. Knee. 2012;19(2):120\u20133.","journal-title":"Knee"},{"key":"3246_CR19","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1097\/00003086-198801000-00010","volume":"226","author":"JR Moreland","year":"1988","unstructured":"Moreland JR. Mechanisms of failure in total knee arthroplasty. Clin Orthop Relat Res. 1988;226:49\u201364.","journal-title":"Clin Orthop Relat Res"},{"issue":"2","key":"3246_CR20","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1007\/s12178-014-9218-y","volume":"7","author":"JJ Cherian","year":"2014","unstructured":"Cherian JJ, Kapadia BH, Banerjee S, Jauregui JJ, Issa K, Mont MA. Mechanical, anatomical, and kinematic axis in TKA: concepts and practical applications. Curr Rev Musculoskelet Med. 2014;7(2):89\u201395.","journal-title":"Curr Rev Musculoskelet Med"},{"key":"3246_CR21","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1016\/j.jor.2021.02.010","volume":"24","author":"J Glasser","year":"2021","unstructured":"Glasser J, Mariorenzi M, Blood T, O\u2019Donnell S, Garcia D, Antoci V. Distal femoral valgus cut angles unreliable in total knee arthroplasty. J Orthop. 2021;24:29\u201333.","journal-title":"J Orthop"},{"issue":"1","key":"3246_CR22","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1177\/230949900701500108","volume":"15","author":"W Yau","year":"2007","unstructured":"Yau W, Chiu K, Tang W, Ng T. Coronal bowing of the femur and tibia in Chinese: its incidence and effects on total knee arthroplasty planning. J Orthop Surg. 2007;15(1):32\u20136.","journal-title":"J Orthop Surg"},{"issue":"7","key":"3246_CR23","doi-asserted-by":"publisher","first-page":"1936","DOI":"10.1007\/s00167-014-3006-5","volume":"23","author":"J-M Kim","year":"2015","unstructured":"Kim J-M, Hong S-H, Lee B-S, Kim D-E, Kim K-A, Bin S-I. Femoral shaft bowing in the coronal plane has more significant effect on the coronal alignment of TKA than proximal or distal variations of femoral shape. Knee Surg Sports Traumatol Arthrosc. 2015;23(7):1936\u201342.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"3246_CR24","unstructured":"Munro BH. Correlation. Statistical methods for health care research. 1997:224\u201345."},{"issue":"9","key":"3246_CR25","first-page":"e504","volume":"34","author":"AV Lombardi Jr","year":"2011","unstructured":"Lombardi AV Jr, Berend KR, Ng VY. Neutral mechanical alignment: a requirement for successful TKA: affirms. Orthopedics. 2011;34(9):e504\u20136.","journal-title":"Orthopedics"},{"issue":"4","key":"3246_CR26","doi-asserted-by":"publisher","first-page":"733","DOI":"10.1007\/s00264-013-2157-1","volume":"38","author":"B Kniesel","year":"2014","unstructured":"Kniesel B, Konstantinidis L, Hirschm\u00fcller A, S\u00fcdkamp N, Helwig P. Digital templating in total knee and hip replacement: an analysis of planning accuracy. Int Orthop. 2014;38(4):733\u20139.","journal-title":"Int Orthop"},{"issue":"11","key":"3246_CR27","doi-asserted-by":"publisher","first-page":"e516","DOI":"10.5435\/JAAOS-D-18-00272","volume":"27","author":"MM Alzahrani","year":"2019","unstructured":"Alzahrani MM, Wood TJ, Somerville LE, Howard JL, Lanting BA, Vasarhelyi EM. Correlation of short knee radiographs and full-length radiographs in patients undergoing total knee arthroplasty. JAAOS-J Am Acad Orthopaedic Surg. 2019;27(11):e516\u201321.","journal-title":"JAAOS-J Am Acad Orthopaedic Surg"},{"issue":"4","key":"3246_CR28","doi-asserted-by":"publisher","first-page":"220","DOI":"10.5435\/JAAOS-D-14-00332","volume":"24","author":"M Tanzer","year":"2016","unstructured":"Tanzer M, Makhdom AM. Preoperative planning in primary total knee arthroplasty. J Am Acad Orthop Surg. 2016;24(4):220\u201330.","journal-title":"J Am Acad Orthop Surg"},{"issue":"2","key":"3246_CR29","doi-asserted-by":"publisher","first-page":"349","DOI":"10.1016\/j.jbiomech.2004.02.024","volume":"38","author":"FW Werner","year":"2005","unstructured":"Werner FW, Ayers DC, Maletsky LP, Rullkoetter PJ. The effect of valgus\/varus malalignment on load distribution in total knee replacements. J Biomech. 2005;38(2):349\u201355.","journal-title":"J Biomech"},{"key":"3246_CR30","doi-asserted-by":"publisher","first-page":"124","DOI":"10.1097\/00003086-200111000-00015","volume":"392","author":"DD D\u2019Lima","year":"2001","unstructured":"D\u2019Lima DD, Hermida JC, Chen PC, Colwell CW Jr. Polyethylene wear and variations in knee kinematics. Clin Orthopaedics Relat Res. 2001;392:124\u201330.","journal-title":"Clin Orthopaedics Relat Res"},{"key":"3246_CR31","doi-asserted-by":"publisher","first-page":"232","DOI":"10.1097\/00003086-200111000-00029","volume":"392","author":"DD D\u2019Lima","year":"2001","unstructured":"D\u2019Lima DD, Chen PC, Colwell CW Jr. Polyethylene contact stresses, articular congruity, and knee alignment. Clin Orthopaedics Relat Res. 2001;392:232\u20138.","journal-title":"Clin Orthopaedics Relat Res"},{"issue":"10","key":"3246_CR32","doi-asserted-by":"publisher","first-page":"2325","DOI":"10.1007\/s00167-013-2481-4","volume":"21","author":"L Vanlommel","year":"2013","unstructured":"Vanlommel L, Vanlommel J, Claes S, Bellemans J. Slight undercorrection following total knee arthroplasty results in superior clinical outcomes in varus knees. Knee Surg Sports Traumatol Arthrosc. 2013;21(10):2325\u201330.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"6","key":"3246_CR33","doi-asserted-by":"publisher","first-page":"1730","DOI":"10.1002\/art.21100","volume":"52","author":"VB Kraus","year":"2005","unstructured":"Kraus VB, Vail TP, Worrell T, McDaniel G. A comparative assessment of alignment angle of the knee by radiographic and physical examination methods. Arthritis Rheum. 2005;52(6):1730\u20135.","journal-title":"Arthritis Rheum"},{"issue":"1","key":"3246_CR34","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1016\/S0883-5403(88)80054-8","volume":"3","author":"TL Petersen","year":"1988","unstructured":"Petersen TL, Engh GA. Radiographic assessment of knee alignment after total knee arthroplasty. J Arthroplasty. 1988;3(1):67\u201372.","journal-title":"J Arthroplasty"},{"issue":"2","key":"3246_CR35","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1016\/0968-0160(95)00011-D","volume":"2","author":"Y Ishii","year":"1995","unstructured":"Ishii Y, Ohmori G, Bechtold JE, Sherman R, Gustilo R. Accuracy of the short radiograph in the measurement of the tibiofemoral angle. Knee. 1995;2(2):81\u20134.","journal-title":"Knee"},{"issue":"4","key":"3246_CR36","doi-asserted-by":"publisher","first-page":"299","DOI":"10.3928\/01477447-20070401-14","volume":"30","author":"MA Rauh","year":"2007","unstructured":"Rauh MA, Boyle J, Mihalko WM, Phillips MJ, Mary Bayers-Thering MS, M, Krackow KA. Reliability of measuring long-standing lower extremity radiographs. Orthopedics. 2007;30(4):299.","journal-title":"Orthopedics"},{"issue":"4","key":"3246_CR37","doi-asserted-by":"publisher","first-page":"755","DOI":"10.1016\/j.arth.2018.12.013","volume":"34","author":"SN Andrews","year":"2019","unstructured":"Andrews SN, Beeler DM, Parke EA, Nakasone CK, Stickley CD. Fixed distal femoral cut of 6\u00b0 valgus in total knee arthroplasty: a radiographic review of 788 consecutive cases. J Arthroplasty. 2019;34(4):755\u20139.","journal-title":"J Arthroplasty"},{"issue":"5","key":"3246_CR38","doi-asserted-by":"publisher","first-page":"1579","DOI":"10.1007\/s00167-019-05577-1","volume":"28","author":"H-J Lee","year":"2020","unstructured":"Lee H-J, Lim J-W, Lee D-H, Kim D-H, Park Y-B. Slight under-correction using individualized intentional varus femoral cutting leads to favorable outcomes in patients with lateral femoral bowing and varus knee. Knee Surg Sports Traumatol Arthrosc. 2020;28(5):1579\u201386.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"5","key":"3246_CR39","doi-asserted-by":"publisher","first-page":"1434","DOI":"10.1007\/s00167-018-5041-0","volume":"27","author":"M Lampart","year":"2019","unstructured":"Lampart M, Behrend H, Moser LB, Hirschmann MT. Due to great variability fixed HKS angle for alignment of the distal cut leads to a significant error in coronal TKA orientation. Knee Surg Sports Traumatol Arthrosc. 2019;27(5):1434\u201341.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"1","key":"3246_CR40","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s13018-019-1133-x","volume":"14","author":"DA Cohen","year":"2019","unstructured":"Cohen DA, Gursel AC, Low AK. How coronal alignment affects distal femoral anatomy: an MRI-based comparison of varus and valgus knees. J Orthop Surg Res. 2019;14(1):1\u20135.","journal-title":"J Orthop Surg Res"},{"issue":"1","key":"3246_CR41","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1016\/j.arth.2012.04.014","volume":"28","author":"AB Mullaji","year":"2013","unstructured":"Mullaji AB, Shetty GM, Kanna R, Vadapalli RC. The influence of preoperative deformity on valgus correction angle: an analysis of 503 total knee arthroplasties. J Arthroplasty. 2013;28(1):20\u20137.","journal-title":"J Arthroplasty"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-022-03246-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13018-022-03246-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-022-03246-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,8,8]],"date-time":"2022-08-08T07:11:04Z","timestamp":1659942664000},"score":1,"resource":{"primary":{"URL":"https:\/\/josr-online.biomedcentral.com\/articles\/10.1186\/s13018-022-03246-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,8,8]]},"references-count":41,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["3246"],"URL":"https:\/\/doi.org\/10.1186\/s13018-022-03246-7","relation":{},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,8,8]]},"assertion":[{"value":"29 July 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 July 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 August 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The project registration ID: SBMU.RETECH.REC.1399.1097. Informed consent and consent to publish was obtained from all individual participants whose archived data included in the study; the data of patients in the study was kept confidential The research was supervised by Deputy of Research, Shahid Beheshti University of Medical Sciences, Tehran, Iran.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"All presentations of case reports must have consent for publication.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that there are no competing of interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"378"}}