{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,17]],"date-time":"2026-03-17T02:20:23Z","timestamp":1773714023209,"version":"3.50.1"},"reference-count":34,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,7,30]],"date-time":"2022-07-30T00:00:00Z","timestamp":1659139200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,7,30]],"date-time":"2022-07-30T00:00:00Z","timestamp":1659139200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>We created patient-based 3D finite-element (FE) models that simulate the congruent-arc Latarjet (CAL) and traditional Latarjet (TL) procedures and then compared their stress distribution patterns with different arm positions and glenoid defects.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>The computed tomography data of 10 adult patients (9 men and 1 woman, ages: 18\u201350\u00a0years) were used to develop the 3D FE glenohumeral joint models. Twenty-five and 35% bony defects were created on the anterior glenoid rim, and the coracoid process was transferred flush with the glenoid by the traditional and congruent-arc techniques using two half-threaded screws. A load was applied to the greater tuberosity toward the center of the glenoid, and a tensile force (20\u00a0N) was applied to the coracoid tip along the direction of the conjoint tendon. The distribution patterns of the von Mises stress in the traditional and congruent-arc Latarjet techniques were compared.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The mean von Mises on the graft was significantly greater for the TL technique than for the CAL. While the von Mises stress was greater in the distal medial part of the graft in the TL models, a higher stress concentration was observed in the distal lateral edge of the coracoid graft in the CAL models. The proximal medial part of the graft exhibited significantly lower von Mises stress than the distal medial part when compared according to technique, defect size, and arm position. Increasing the glenoid defect from 25 to 35% resulted in a significant increase in stress on the lateral side of the graft in both models.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>The stress distribution patterns and stress magnitude of the coracoid grafts differed according to the procedure. Due to placing less stress on the proximal\u2013medial part of the graft, the CAL technique may lead to insufficient stimulation for bone formation at the graft\u2013glenoid interface, resulting in a higher incidence of graft osteolysis.<\/jats:p>\n                <jats:p><jats:italic>Clinical relevance<\/jats:italic> The CAL technique may lead to a higher incidence of graft osteolysis.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Level of evidence<\/jats:title>\n                <jats:p>Basic Science Study; Computer Modeling.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s13018-022-03264-5","type":"journal-article","created":{"date-parts":[[2022,7,30]],"date-time":"2022-07-30T15:02:42Z","timestamp":1659193362000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Comparison of two coracoid process transfer techniques on stress shielding using three-dimensional finite-element model"],"prefix":"10.1186","volume":"17","author":[{"given":"Seyyid Serif","family":"Unsal","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tugrul","family":"Yildirim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Murat","family":"Kayalar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,7,30]]},"reference":[{"issue":"4","key":"3264_CR1","first-page":"604","volume":"54","author":"M Latarjet","year":"1958","unstructured":"Latarjet M. Technic of coracoid preglenoid arthroereisis in the treatment of recurrent dislocation of the shoulder. Lyon Chir. 1958;54(4):604\u20137.","journal-title":"Lyon Chir"},{"issue":"1","key":"3264_CR2","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1016\/j.ocl.2014.09.005","volume":"46","author":"MA Joshi","year":"2015","unstructured":"Joshi MA, Young AA, Balestro JC, Walch G. The Latarjet-Patte procedure for recurrent anterior shoulder instability in contact athletes. Orthop Clin North Am. 2015;46(1):105\u201311.","journal-title":"Orthop Clin North Am"},{"issue":"10","key":"3264_CR3","doi-asserted-by":"publisher","first-page":"1033","DOI":"10.1016\/j.arthro.2007.08.009","volume":"23","author":"SS Burkhart","year":"2007","unstructured":"Burkhart SS, De Beer JF, Barth JR, Cresswell T, Roberts C, Richards DP. Results of modified Latarjet reconstruction in patients with anteroinferior instability and significant bone loss. Arthroscopy. 2007;23(10):1033\u201341.","journal-title":"Arthroscopy"},{"issue":"4","key":"3264_CR4","doi-asserted-by":"publisher","first-page":"280","DOI":"10.1302\/2058-5241.6.200074","volume":"6","author":"LA Rossi","year":"2021","unstructured":"Rossi LA, Tanoira I, De Cicco FL, Ranalletta M. Traditional versus congruent-arc Latarjet anatomic and biomechanical perspective. EFORT Open Rev. 2021;6(4):280\u20137.","journal-title":"EFORT Open Rev"},{"issue":"12","key":"3264_CR5","doi-asserted-by":"publisher","first-page":"1689","DOI":"10.1016\/j.jse.2013.02.014","volume":"22","author":"JS Dines","year":"2013","unstructured":"Dines JS, Dodson CC, McGarry MH, Oh JH, Altchek DW, Lee TQ. Contribution of osseous and muscular stabilizing effects with the Latarjet procedure for anterior instability without glenoid bone loss. J Shoulder Elbow Surg. 2013;22(12):1689\u201394.","journal-title":"J Shoulder Elbow Surg"},{"issue":"11","key":"3264_CR6","doi-asserted-by":"publisher","first-page":"1691","DOI":"10.1016\/j.jse.2014.02.015","volume":"23","author":"N Mizuno","year":"2014","unstructured":"Mizuno N, Denard PJ, Raiss P, Melis B, Walch G. Long-term results of the Latarjet procedure for anterior instability of the shoulder. J Shoulder Elbow Surg. 2014;23(11):1691\u20139.","journal-title":"J Shoulder Elbow Surg"},{"issue":"6","key":"3264_CR7","doi-asserted-by":"publisher","first-page":"989","DOI":"10.1016\/j.jse.2010.11.016","volume":"20","author":"G Di Giacomo","year":"2011","unstructured":"Di Giacomo G, Costantini A, de Gasperis N, De Vita A, Lin BK, Francone M, et al. Coracoid graft osteolysis after the Latarjet procedure for anteroinferior shoulder instability: a computed tomography scan study of twenty-six patients. J Shoulder Elbow Surg. 2011;20(6):989\u201395.","journal-title":"J Shoulder Elbow Surg"},{"issue":"11","key":"3264_CR8","doi-asserted-by":"publisher","first-page":"2059","DOI":"10.2106\/JBJS.I.00261","volume":"92","author":"N Yamamoto","year":"2010","unstructured":"Yamamoto N, Muraki T, Sperling JW, Steinmann SP, Cofield RH, Itoi E, et al. Stabilizing mechanism in bone-grafting of a large glenoid defect. J Bone Joint Surg Am. 2010;92(11):2059\u201366.","journal-title":"J Bone Joint Surg Am"},{"issue":"3","key":"3264_CR9","doi-asserted-by":"publisher","first-page":"407","DOI":"10.1016\/j.ocl.2010.02.008","volume":"41","author":"JF de Beer","year":"2010","unstructured":"de Beer JF, Roberts C. Glenoid bone defects\u2013open latarjet with congruent arc modification. Orthop Clin North Am. 2010;41(3):407\u201315.","journal-title":"Orthop Clin North Am"},{"issue":"11","key":"3264_CR10","doi-asserted-by":"publisher","first-page":"1485","DOI":"10.1016\/j.arthro.2011.06.020","volume":"27","author":"MS Armitage","year":"2011","unstructured":"Armitage MS, Elkinson I, Giles JW, Athwal GS. An anatomic, computed tomographic assessment of the coracoid process with special reference to the congruent-arc latarjet procedure. Arthroscopy. 2011;27(11):1485\u20139.","journal-title":"Arthroscopy"},{"issue":"5","key":"3264_CR11","doi-asserted-by":"publisher","first-page":"1140","DOI":"10.1177\/0363546513478578","volume":"41","author":"A Dehaan","year":"2013","unstructured":"Dehaan A, Munch J, Durkan M, Yoo J, Crawford D. Reconstruction of a bony bankart lesion: best fit based on radius of curvature. Am J Sports Med. 2013;41(5):1140\u20135.","journal-title":"Am J Sports Med"},{"issue":"8","key":"3264_CR12","doi-asserted-by":"publisher","first-page":"1113","DOI":"10.1016\/j.jse.2013.11.011","volume":"23","author":"B Noonan","year":"2014","unstructured":"Noonan B, Hollister SJ, Sekiya JK, Bedi A. Comparison of reconstructive procedures for glenoid bone loss associated with recurrent anterior shoulder instability. J Shoulder Elbow Surg. 2014;23(8):1113\u20139.","journal-title":"J Shoulder Elbow Surg"},{"issue":"12","key":"3264_CR13","doi-asserted-by":"publisher","first-page":"2801","DOI":"10.1177\/0363546512460835","volume":"40","author":"JW Giles","year":"2012","unstructured":"Giles JW, Puskas G, Welsh M, Johnson JA, Athwal GS. Do the traditional and modified latarjet techniques produce equivalent reconstruction stability and strength? Am J Sports Med. 2012;40(12):2801\u20137.","journal-title":"Am J Sports Med"},{"issue":"6","key":"3264_CR14","doi-asserted-by":"publisher","first-page":"1252","DOI":"10.1177\/0363546516685318","volume":"45","author":"SR Montgomery","year":"2017","unstructured":"Montgomery SR, Katthagen JC, Mikula JD, Marchetti DC, Tahal DS, Dornan GJ, et al. Anatomic and biomechanical comparison of the classic and congruent-arc techniques of the Latarjet procedure. Am J Sports Med. 2017;45(6):1252\u201360.","journal-title":"Am J Sports Med"},{"issue":"2","key":"3264_CR15","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1007\/s00402-020-03426-2","volume":"141","author":"C Chillemi","year":"2021","unstructured":"Chillemi C, Guerrisi M, Paglialunga C, Salate Santone F, Osimani M. Latarjet procedure for anterior shoulder instability: a 24-year follow-up study. Arch Orthop Trauma Surg. 2021;141(2):189\u201396.","journal-title":"Arch Orthop Trauma Surg"},{"issue":"2","key":"3264_CR16","doi-asserted-by":"publisher","first-page":"e33","DOI":"10.1016\/j.jse.2018.08.028","volume":"28","author":"ET Hurley","year":"2019","unstructured":"Hurley ET, Jamal MS, Ali ZS, Montgomery C, Pauzenberger L, Mullett H. Long-term outcomes of the Latarjet procedure for anterior shoulder instability: a systematic review of studies at 10-year follow-up. J Shoulder Elbow Surg. 2019;28(2):e33\u20139.","journal-title":"J Shoulder Elbow Surg"},{"issue":"1","key":"3264_CR17","doi-asserted-by":"publisher","first-page":"1","DOI":"10.4103\/0973-6042.109877","volume":"7","author":"GD Giacomo","year":"2013","unstructured":"Giacomo GD, Costantini A, de Gasperis N, De Vita A, Lin BK, Francone M, et al. Coracoid bone graft osteolysis after Latarjet procedure: a comparison study between two screws standard technique vs mini-plate fixation. Int J Shoulder Surg. 2013;7(1):1\u20136.","journal-title":"Int J Shoulder Surg"},{"issue":"10","key":"3264_CR18","doi-asserted-by":"publisher","first-page":"2260","DOI":"10.1016\/j.jse.2021.02.014","volume":"30","author":"H Sano","year":"2021","unstructured":"Sano H, Komatsuda T, Abe H, Ozawa H, Kumagai J, Yokobori TA Jr. Intra-articular biomechanical environment following modified Bristow and Latarjet procedures in shoulders with large glenoid defects: Relationship with postoperative complications. J Shoulder Elbow Surg. 2021;30(10):2260\u20139.","journal-title":"J Shoulder Elbow Surg"},{"issue":"12","key":"3264_CR19","doi-asserted-by":"publisher","first-page":"2632","DOI":"10.1016\/j.jse.2020.03.037","volume":"29","author":"H Sano","year":"2020","unstructured":"Sano H, Komatsuda T, Abe H, Ozawa H, Yokobori TA Jr. Proximal-medial part in the coracoid graft demonstrates the most evident stress shielding following the Latarjet procedure: a simulation study using the 3-dimensional finite element method. J Shoulder Elbow Surg. 2020;29(12):2632\u20139.","journal-title":"J Shoulder Elbow Surg"},{"issue":"8","key":"3264_CR20","doi-asserted-by":"publisher","first-page":"2560","DOI":"10.1007\/s00167-015-3923-y","volume":"24","author":"SM Thompson","year":"2016","unstructured":"Thompson SM, Yohuno D, Bradley WN, Crocombe AD. Finite element analysis: a comparison of an all-polyethylene tibial implant and its metal-backed equivalent. Knee Surg Sports Traumatol Arthrosc. 2016;24(8):2560\u20136.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"1","key":"3264_CR21","doi-asserted-by":"publisher","first-page":"13","DOI":"10.7547\/16-112","volume":"109","author":"S Inal","year":"2019","unstructured":"Inal S, Gok K, Gok A, Pinar AM, Inal C. Comparison of biomechanical effects of different configurations of Kirschner wires on the epiphyseal plate and stability in a Salter-Harris type 2 distal femoral fracture model. J Am Podiatr Med Assoc. 2019;109(1):13\u201321.","journal-title":"J Am Podiatr Med Assoc"},{"issue":"1","key":"3264_CR22","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1002\/rcs.1584","volume":"11","author":"S Inal","year":"2015","unstructured":"Inal S, Taspinar F, Gulbandilar E, Gok K. Comparison of the biomechanical effects of pertrochanteric fixator and dynamic hip screw on an intertrochanteric femoral fracture using the finite element method. Int J Med Robot. 2015;11(1):95\u2013103.","journal-title":"Int J Med Robot"},{"key":"3264_CR23","doi-asserted-by":"publisher","DOI":"10.3390\/jcm9010207","author":"M Gregori","year":"2020","unstructured":"Gregori M, Eichelberger L, Gahleitner C, Hajdu S, Pretterklieber M. relationship between the thickness of the coracoid process and Latarjet graft positioning-an anatomical study on 70 embalmed scapulae. J Clin Med. 2020. https:\/\/doi.org\/10.3390\/jcm9010207.","journal-title":"J Clin Med"},{"issue":"5","key":"3264_CR24","doi-asserted-by":"publisher","first-page":"769","DOI":"10.1016\/j.jse.2010.01.011","volume":"19","author":"MC Beran","year":"2010","unstructured":"Beran MC, Donaldson CT, Bishop JY. Treatment of chronic glenoid defects in the setting of recurrent anterior shoulder instability: a systematic review. J Shoulder Elbow Surg. 2010;19(5):769\u201380.","journal-title":"J Shoulder Elbow Surg"},{"issue":"15","key":"3264_CR25","doi-asserted-by":"publisher","first-page":"1390","DOI":"10.2106\/JBJS.L.00777","volume":"95","author":"N Yamamoto","year":"2013","unstructured":"Yamamoto N, Muraki T, An KN, Sperling JW, Cofield RH, Itoi E, et al. The stabilizing mechanism of the Latarjet procedure: a cadaveric study. J Bone Joint Surg Am. 2013;95(15):1390\u20137.","journal-title":"J Bone Joint Surg Am"},{"issue":"2","key":"3264_CR26","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1177\/1947603516651669","volume":"8","author":"C Schleich","year":"2017","unstructured":"Schleich C, Bittersohl B, Antoch G, Krauspe R, Zilkens C, Kircher J. Thickness distribution of glenohumeral joint cartilage. Cartilage. 2017;8(2):105\u201311.","journal-title":"Cartilage"},{"issue":"2","key":"3264_CR27","doi-asserted-by":"publisher","first-page":"309","DOI":"10.1016\/j.arthro.2012.09.007","volume":"29","author":"HW Boons","year":"2013","unstructured":"Boons HW, Giles JW, Elkinson I, Johnson JA, Athwal GS. Classic versus congruent coracoid positioning during the Latarjet procedure: an in vitro biomechanical comparison. Arthroscopy. 2013;29(2):309\u201316.","journal-title":"Arthroscopy"},{"issue":"1","key":"3264_CR28","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1186\/s13018-017-0707-8","volume":"13","author":"F Chen","year":"2018","unstructured":"Chen F, Huang X, Ya Y, Ma F, Qian Z, Shi J, et al. Finite element analysis of intramedullary nailing and double locking plate for treating extra-articular proximal tibial fractures. J Orthop Surg Res. 2018;13(1):12.","journal-title":"J Orthop Surg Res"},{"issue":"3","key":"3264_CR29","doi-asserted-by":"publisher","first-page":"484","DOI":"10.1016\/j.jse.2016.08.007","volume":"26","author":"DL Haeni","year":"2017","unstructured":"Haeni DL, Opsomer G, Sood A, Munji J, Sanchez M, Villain B, et al. Three-dimensional volume measurement of coracoid graft osteolysis after arthroscopic Latarjet procedure. J Shoulder Elbow Surg. 2017;26(3):484\u20139.","journal-title":"J Shoulder Elbow Surg"},{"issue":"10","key":"3264_CR30","doi-asserted-by":"publisher","first-page":"232596712110302","DOI":"10.1177\/23259671211030204","volume":"9","author":"SRP Mengers","year":"2021","unstructured":"Mengers SRP, Knapik DM, Kaufman MW, Edwards G, Voos JE, Gillespie RJ, et al. Clinical outcomes of the traditional latarjet versus the congruent arc modification for the treatment of recurrent anterior shoulder instability: a meta-analysis. Orthop J Sports Med. 2021;9(10):23259671211030204. https:\/\/doi.org\/10.1177\/23259671211030204.","journal-title":"Orthop J Sports Med"},{"issue":"4","key":"3264_CR31","doi-asserted-by":"publisher","first-page":"514","DOI":"10.1016\/j.jse.2013.10.005","volume":"23","author":"G Di Giacomo","year":"2014","unstructured":"Di Giacomo G, de Gasperis N, Costantini A, De Vita A, Beccaglia MA, Pouliart N. Does the presence of glenoid bone loss influence coracoid bone graft osteolysis after the Latarjet procedure? A computed tomography scan study in 2 groups of patients with and without glenoid bone loss. J Shoulder Elbow Surg. 2014;23(4):514\u20138.","journal-title":"J Shoulder Elbow Surg"},{"issue":"12","key":"3264_CR32","doi-asserted-by":"publisher","first-page":"2418","DOI":"10.1016\/j.jse.2019.04.050","volume":"28","author":"DN Bhatia","year":"2019","unstructured":"Bhatia DN, Kandhari V. Bone defect-induced alteration in glenoid articular surface geometry and restoration with coracoid transfer procedures: a cadaveric study. J Shoulder Elbow Surg. 2019;28(12):2418\u201326.","journal-title":"J Shoulder Elbow Surg"},{"issue":"6","key":"3264_CR33","doi-asserted-by":"publisher","first-page":"1478","DOI":"10.2106\/JBJS.I.00220","volume":"92","author":"N Ghodadra","year":"2010","unstructured":"Ghodadra N, Gupta A, Romeo AA, Bach BR Jr, Verma N, Shewman E, et al. Normalization of glenohumeral articular contact pressures after Latarjet or iliac crest bone-grafting. J Bone Joint Surg Am. 2010;92(6):1478\u201389.","journal-title":"J Bone Joint Surg Am"},{"issue":"5","key":"3264_CR34","doi-asserted-by":"publisher","first-page":"946","DOI":"10.1016\/j.arthro.2016.09.035","volume":"33","author":"GD Dumont","year":"2017","unstructured":"Dumont GD, Vopat BG, Parada S, Cohn R, Makani A, Sanchez G, et al. Traditional versus congruent arc Latarjet technique: effect on surface area for union and bone width surrounding screws. Arthroscopy. 2017;33(5):946\u201352.","journal-title":"Arthroscopy"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-022-03264-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13018-022-03264-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-022-03264-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,7,30]],"date-time":"2022-07-30T15:02:50Z","timestamp":1659193370000},"score":1,"resource":{"primary":{"URL":"https:\/\/josr-online.biomedcentral.com\/articles\/10.1186\/s13018-022-03264-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7,30]]},"references-count":34,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["3264"],"URL":"https:\/\/doi.org\/10.1186\/s13018-022-03264-5","relation":{},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,7,30]]},"assertion":[{"value":"14 May 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 July 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 July 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was carried out following ethical standards under the Declaration of Helsinki of 1964. The acquisition of CT images was approved by the Ethics Committee of the SBU Kanuni Research and Education Hospital, Trabzon, Turkey (approval no: 2022\/19), and written consent was obtained from the volunteers.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"The patients enrolled in the study agreed to the use of the data for research and to authorize its publication.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"371"}}