{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,24]],"date-time":"2026-09-24T01:59:37Z","timestamp":1790215177719,"version":"4.1.0"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,11,16]],"date-time":"2022-11-16T00:00:00Z","timestamp":1668556800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,11,16]],"date-time":"2022-11-16T00:00:00Z","timestamp":1668556800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100009592","name":"Beijing Municipal Science and Technology Commission","doi-asserted-by":"crossref","award":["Z191100006619040"],"award-info":[{"award-number":["Z191100006619040"]}],"id":[{"id":"10.13039\/501100009592","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Objective<\/jats:title>\n                <jats:p>This study aims to investigate the clinical application and feasibility of C2 subfacetal screws in patients with Klippel-Feil syndrome (KFS), narrow C2 pedicles, and high-riding vertebral arteries (HRVAs).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>The clinical data of seven patients with KFS, atlantoaxial dislocation, narrow C2 pedicles, and HRVAs treated with C2 subfacetal screws were analyzed in this retrospective study. The internal height, isthmus height, and pedicle width of C2 vertebra were measured using preoperative computed tomography (CT). Subfacetal screws were inserted for 7 patients (12 sides). The position and length of the screws were observed using postoperative CT. Intraoperative dura mater and vertebral artery (VA) injuries were recorded. Bone fusion was observed using follow-up CT.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The internal height was 10.5\u2009\u00b1\u20093.2\u00a0mm, the isthmus height was 3.7\u2009\u00b1\u20091.8\u00a0mm, the pedicle width was 3.0\u2009\u00b1\u20091.4\u00a0mm, and the screw length was 19.7\u2009\u00b1\u20091.5\u00a0mm. All patients had HRVAs and narrow pedicles. No injury to the dura mater and vertebral artery (VA) occurred in this group of patients. Bone fusion was achieved in all patients during follow-up.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>In patients with KFS, HRVA, and a narrow C2 pedicle, there is sufficient space below the C2 articular surface for screw insertion. When the pedicle is narrow and the C2 pedicle screw is not suitable for placement due to possible injury to the VA, subfacetal screws are a feasible alternative.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s13018-022-03391-z","type":"journal-article","created":{"date-parts":[[2022,11,16]],"date-time":"2022-11-16T23:02:36Z","timestamp":1668639756000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":12,"title":["Application of C2 subfacetal screws for the management of atlantoaxial dislocation in patients with Klippel-Feil syndrome characterized by a narrow C2 pedicle and high-riding vertebral artery"],"prefix":"10.1186","volume":"17","author":[{"given":"Zhe","family":"Hou","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qiang","family":"Jian","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wayne","family":"Fan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xingang","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yinqian","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tao","family":"Fan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,11,16]]},"reference":[{"issue":"14","key":"3391_CR1","doi-asserted-by":"publisher","first-page":"1425","DOI":"10.1097\/00007632-199907150-00007","volume":"24","author":"K Abumi","year":"1999","unstructured":"Abumi K, Takada T, Shono Y, Kaneda K, Fujiya M. Posterior occipitocervical reconstruction using cervical pedicle screws and plate-rod systems. Spine. 1999;24(14):1425\u201334. https:\/\/doi.org\/10.1097\/00007632-199907150-00007.","journal-title":"Spine"},{"key":"3391_CR2","doi-asserted-by":"publisher","DOI":"10.3171\/2019.11.SPINE191178","author":"YQ Du","year":"2020","unstructured":"Du YQ, Li T, Ma C, Qiao GY, Yin YH, Yu XG. Biomechanical evaluation of two alternative techniques to the Goel-Harms technique for atlantoaxial fixation: C1 lateral mass-C2 bicortical translaminar screw fixation and C1 lateral mass-C2\/3 transarticular screw fixation. J Neurosurg Spine. 2020. https:\/\/doi.org\/10.3171\/2019.11.SPINE191178.","journal-title":"J Neurosurg Spine"},{"key":"3391_CR3","doi-asserted-by":"publisher","DOI":"10.3171\/2020.2.SPINE191517","author":"YQ Du","year":"2020","unstructured":"Du YQ, Yin YH, Qiao GY, Yu XG. C2 medial pedicle screw: a novel \u201cin-out-in\u201d technique as an alternative option for posterior C2 fixation in cases with a narrow C2 isthmus. J Neurosurg Spine. 2020. https:\/\/doi.org\/10.3171\/2020.2.SPINE191517.","journal-title":"J Neurosurg Spine"},{"key":"3391_CR4","doi-asserted-by":"publisher","DOI":"10.1007\/s10143-021-01729-5","author":"YQ Du","year":"2022","unstructured":"Du YQ, Yin YH, Li T, Qiao GY, Yu XG. Can C1 lateral mass and C3 pedicle screw fixation be used as an option for atlantoaxial reduction and stabilization in Klippel-Feil patients? A study of its morphological feasibility, technical nuances, and clinical efficiency. Neurosurg Rev. 2022. https:\/\/doi.org\/10.1007\/s10143-021-01729-5.","journal-title":"Neurosurg Rev"},{"issue":"3","key":"3391_CR5","doi-asserted-by":"publisher","first-page":"2183","DOI":"10.1007\/s10143-021-01729-5","volume":"45","author":"YQ Du","year":"2022","unstructured":"Du YQ, Yin YH, Li T, Qiao GY, Yu XG. Can C1 lateral mass and C3 pedicle screw fixation be used as an option for atlantoaxial reduction and stabilization in Klippel-Feil patients? A study of its morphological feasibility, technical nuances, and clinical efficiency. Neurosurg Rev. 2022;45(3):2183\u201392. https:\/\/doi.org\/10.1007\/s10143-021-01729-5.","journal-title":"Neurosurg Rev"},{"issue":"6","key":"3391_CR6","doi-asserted-by":"publisher","first-page":"577","DOI":"10.3171\/2012.9.SPINE111021","volume":"17","author":"RE Elliott","year":"2012","unstructured":"Elliott RE, Tanweer O, Boah A, Smith ML, Frempong-Boadu A. Comparison of safety and stability of C-2 pars and pedicle screws for atlantoaxial fusion: meta-analysis and review of the literature. J Neurosurg Spine. 2012;17(6):577\u201393. https:\/\/doi.org\/10.3171\/2012.9.SPINE111021.","journal-title":"J Neurosurg Spine"},{"issue":"1","key":"3391_CR7","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1097\/MCD.0000000000000301","volume":"29","author":"R Frikha","year":"2020","unstructured":"Frikha R. Klippel-Feil syndrome: a review of the literature. Clin Dysmorphol. 2020;29(1):35\u20137. https:\/\/doi.org\/10.1097\/MCD.0000000000000301.","journal-title":"Clin Dysmorphol"},{"key":"3391_CR8","doi-asserted-by":"publisher","first-page":"533","DOI":"10.1016\/j.wneu.2017.07.007","volume":"110","author":"A Goel","year":"2018","unstructured":"Goel A, Jain S, Shah A. Radiological evaluation of 510 cases of basilar invagination with evidence of atlantoaxial instability (group A basilar invagination). World Neurosurg. 2018;110:533\u201343. https:\/\/doi.org\/10.1016\/j.wneu.2017.07.007.","journal-title":"World Neurosurg"},{"issue":"4","key":"3391_CR9","doi-asserted-by":"publisher","first-page":"E322","DOI":"10.1093\/ons\/opaa456","volume":"20","author":"A Goel","year":"2021","unstructured":"Goel A, Prasad A, Shah A, Sasane S, Hawaldar A, Biswas C, Thomas A. Transarticular fixation following mobilization of \u201chigh-riding\u201d vertebral artery. Oper Neurosurg. 2021;20(4):E322\u20135. https:\/\/doi.org\/10.1093\/ons\/opaa456.","journal-title":"Oper Neurosurg"},{"issue":"4","key":"3391_CR10","doi-asserted-by":"publisher","first-page":"448","DOI":"10.1016\/j.jspd.2017.12.002","volume":"6","author":"J Gruber","year":"2018","unstructured":"Gruber J, Saleh A, Bakhsh W, Rubery PT, Mesfin A. The prevalence of Klippel-Feil syndrome: a computed tomography-based analysis of 2917 patients. Spine Deform. 2018;6(4):448\u201353. https:\/\/doi.org\/10.1016\/j.jspd.2017.12.002.","journal-title":"Spine Deform"},{"issue":"22","key":"3391_CR11","doi-asserted-by":"publisher","first-page":"2467","DOI":"10.1097\/00007632-200111150-00014","volume":"26","author":"J Harms","year":"2001","unstructured":"Harms J, Melcher RP. Posterior C1\u2013C2 fusion with polyaxial screw and rod fixation. Spine. 2001;26(22):2467\u201371. https:\/\/doi.org\/10.1097\/00007632-200111150-00014.","journal-title":"Spine"},{"key":"3391_CR12","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.RVW.21.00166","author":"A Jae-Min Park","year":"2022","unstructured":"Jae-Min Park A, Nelson SE, Mesfin A. Klippel-Feil syndrome: clinical presentation and management. JBJS Rev. 2022. https:\/\/doi.org\/10.2106\/JBJS.RVW.21.00166.","journal-title":"JBJS Rev"},{"issue":"5","key":"3391_CR13","doi-asserted-by":"publisher","first-page":"1251","DOI":"10.1007\/s00586-022-07146-6","volume":"31","author":"DH Lee","year":"2022","unstructured":"Lee DH, Park S, Cho JH, Hwang CJ, Lee HR, Seok SY, Lee CS. The medial window technique as a salvage method to insert C2 pedicle screw in the case of a high-riding vertebral artery or narrow pedicle: a technical note and case series. European Spine J Off Publ Eur Spine Soc Eur Spinal Deform Soc Eur Sect Cerv Spine Res Soc. 2022;31(5):1251\u20139. https:\/\/doi.org\/10.1007\/s00586-022-07146-6.","journal-title":"European Spine J Off Publ Eur Spine Soc Eur Spinal Deform Soc Eur Sect Cerv Spine Res Soc"},{"issue":"9","key":"3391_CR14","doi-asserted-by":"publisher","first-page":"960","DOI":"10.1097\/BRS.0b013e31816c915b","volume":"33","author":"RA Lehman Jr","year":"2008","unstructured":"Lehman RA Jr, Dmitriev AE, Helgeson MD, Sasso RC, Kuklo TR, Riew KD. Salvage of C2 pedicle and pars screws using the intralaminar technique: a biomechanical analysis. Spine. 2008;33(9):960\u20135. https:\/\/doi.org\/10.1097\/BRS.0b013e31816c915b.","journal-title":"Spine"},{"issue":"22","key":"3391_CR15","doi-asserted-by":"publisher","first-page":"951","DOI":"10.5435\/JAAOS-D-21-00190","volume":"29","author":"J Litrenta","year":"2021","unstructured":"Litrenta J, Bi AS, Dryer JW. Klippel-Feil syndrome: pathogenesis, diagnosis, and management. J Am Acad Orthop Surg. 2021;29(22):951\u201360. https:\/\/doi.org\/10.5435\/JAAOS-D-21-00190.","journal-title":"J Am Acad Orthop Surg"},{"issue":"7","key":"3391_CR16","doi-asserted-by":"publisher","first-page":"666","DOI":"10.1097\/01.BRS.0000051919.14927.57","volume":"28","author":"M Neo","year":"2003","unstructured":"Neo M, Matsushita M, Iwashita Y, Yasuda T, Sakamoto T, Nakamura T. Atlantoaxial transarticular screw fixation for a high-riding vertebral artery. Spine. 2003;28(7):666\u201370. https:\/\/doi.org\/10.1097\/01.BRS.0000051919.14927.57.","journal-title":"Spine"},{"key":"3391_CR17","doi-asserted-by":"publisher","DOI":"10.1080\/02688697.2019.1668538","author":"AP Patankar","year":"2019","unstructured":"Patankar AP. Vertebro-basilar stroke due to Bow-Hunter syndrome: an unusual presentation of rotatory atlanto-axial subluxation in a fourteen year old. Br J Neurosurg. 2019. https:\/\/doi.org\/10.1080\/02688697.2019.1668538.","journal-title":"Br J Neurosurg"},{"key":"3391_CR18","unstructured":"Patkar SV (2014) Sub-facetal C2 body screw in posterior fixation (Goel-Harm's Technique) of the Atlanto-Axial joint avoiding the vertebral artery. Internet J Neurosurg"},{"issue":"4","key":"3391_CR19","doi-asserted-by":"publisher","first-page":"1082","DOI":"10.1007\/s00586-017-4997-7","volume":"26","author":"A Rusconi","year":"2017","unstructured":"Rusconi A, Freitas-Olim E, Coloma P, Messerer R, Barrey C. Bicortical facet screws as a new option for posterior C2 fixation: anatomical study and clinical experience. Eur Spine J Off Publ Eur Spine Soc Eur Spinal Deform Soc Eur Sect Cerv Spine Res Soc. 2017;26(4):1082\u20139. https:\/\/doi.org\/10.1007\/s00586-017-4997-7.","journal-title":"Eur Spine J Off Publ Eur Spine Soc Eur Spinal Deform Soc Eur Sect Cerv Spine Res Soc"},{"key":"3391_CR20","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1016\/j.wneu.2020.08.045","volume":"144","author":"P Salunke","year":"2020","unstructured":"Salunke P, Singh A, Karthigeyan M. Technique of C2 subfacetal screw in patients with high-riding vertebral artery. World Neurosurg. 2020;144:59. https:\/\/doi.org\/10.1016\/j.wneu.2020.08.045.","journal-title":"World Neurosurg"},{"issue":"2","key":"3391_CR21","doi-asserted-by":"publisher","first-page":"583","DOI":"10.1007\/s10143-019-01084-6","volume":"42","author":"G Shang","year":"2019","unstructured":"Shang G, Fan T, Hou Z, Liang C, Wang Y, Zhao X, Fan W. A modified microsurgical interfacet release and direct distraction technique for management of congenital atlantoaxial dislocation: technical note. Neurosurg Rev. 2019;42(2):583\u201391. https:\/\/doi.org\/10.1007\/s10143-019-01084-6.","journal-title":"Neurosurg Rev"},{"issue":"4","key":"3391_CR22","doi-asserted-by":"publisher","first-page":"770","DOI":"10.14245\/ns.2142726.363","volume":"18","author":"Y Tian","year":"2021","unstructured":"Tian Y, Xu N, Yan M, Chen J, Hung KL, Hou X, Wang S, Li W. Vertebral artery variations at the craniovertebral junction in \u201cSandwich\u201d Atlantoaxial dislocation patients. Neurospine. 2021;18(4):770\u20137. https:\/\/doi.org\/10.14245\/ns.2142726.363.","journal-title":"Neurospine"},{"issue":"8","key":"3391_CR23","doi-asserted-by":"publisher","first-page":"1306","DOI":"10.1007\/s00586-010-1418-6","volume":"19","author":"S Wang","year":"2010","unstructured":"Wang S, Wang C, Passias PG, Yan M, Zhou H. Pedicle versus laminar screws: what provides more suitable C2 fixation in congenital C2\u20133 fusion patients? Eur Spine J. 2010;19(8):1306\u201311. https:\/\/doi.org\/10.1007\/s00586-010-1418-6.","journal-title":"Eur Spine J"},{"issue":"5","key":"3391_CR24","doi-asserted-by":"publisher","first-page":"976","DOI":"10.1227\/NEU.0b013e31826cdd3b","volume":"71","author":"S Wang","year":"2012","unstructured":"Wang S, Wang C, Leng H, Zhao W, Yan M, Zhou H. Cable-strengthened C2 pedicle screw fixation in the treatment of congenital C2\u20133 fusion, atlas occipitalization, and atlantoaxial dislocation. Neurosurgery. 2012;71(5):976\u201384. https:\/\/doi.org\/10.1227\/NEU.0b013e31826cdd3b.","journal-title":"Neurosurgery"},{"issue":"8","key":"3391_CR25","doi-asserted-by":"publisher","first-page":"1730","DOI":"10.1007\/s00586-014-3397-5","volume":"23","author":"P Xiu","year":"2014","unstructured":"Xiu P, Wang Q, Wang G, Wang S, Dai G, Lan Y. Morphological and clinical feasibility of C3 pedicle screw instrumentation in patients with congenital C2\u20133 fusion. European Spine J Off Publ Eur Spine Soc Eur Spinal Deform Soc Eur Sect Cerv Spine Res Soc. 2014;23(8):1730\u20136. https:\/\/doi.org\/10.1007\/s00586-014-3397-5.","journal-title":"European Spine J Off Publ Eur Spine Soc Eur Spinal Deform Soc Eur Sect Cerv Spine Res Soc"},{"issue":"7","key":"3391_CR26","doi-asserted-by":"publisher","first-page":"775","DOI":"10.1016\/j.spinee.2013.04.005","volume":"13","author":"JS Yeom","year":"2013","unstructured":"Yeom JS, Buchowski JM, Kim HJ, Chang BS, Lee CK, Riew KD. Risk of vertebral artery injury: comparison between C1\u2013C2 transarticular and C2 pedicle screws. Spine J Off J North Am Spine Soc. 2013;13(7):775\u201385. https:\/\/doi.org\/10.1016\/j.spinee.2013.04.005.","journal-title":"Spine J Off J North Am Spine Soc"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-022-03391-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13018-022-03391-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-022-03391-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,11,16]],"date-time":"2022-11-16T23:13:54Z","timestamp":1668640434000},"score":1,"resource":{"primary":{"URL":"https:\/\/josr-online.biomedcentral.com\/articles\/10.1186\/s13018-022-03391-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,11,16]]},"references-count":26,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["3391"],"URL":"https:\/\/doi.org\/10.1186\/s13018-022-03391-z","relation":{},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,11,16]]},"assertion":[{"value":"12 August 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 November 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 November 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Approval for the retrospective study was obtained from the ethics committee of Sanbo Brain Hospital, and all procedures performed in this study were in accordance with the 1964 Helsinki declaration and its later amendments.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"Not applicable.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Human and animal ethics"}},{"value":"The authors declare that they have no conflicts of interest.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"495"}}