{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,17]],"date-time":"2026-11-17T19:34:21Z","timestamp":1794944061602,"version":"4.9.1"},"reference-count":17,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,2,27]],"date-time":"2023-02-27T00:00:00Z","timestamp":1677456000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,2,27]],"date-time":"2023-02-27T00:00:00Z","timestamp":1677456000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Operative treatment of humeral shaft fractures (AO\/OTA 12) is being performed more frequently. Accordingly, it is important to understand the complications associated with plate fixation. This study analyzes risk factors associated with mechanical failure following plate fixation of humeral shaft fractures in order to further elucidate the mode and location of failure.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A retrospective review of 351 humeral shaft fractures was completed at a single level I trauma center. Eleven of eighty-five humeral shaft fractures had aseptic mechanical failure requiring revision (12.9%), following initial plate fixation. Fracture characteristics (AO type, comminution, location) and fracture fixation (plate type, multiplanar, number of screws proximal and distal to the fracture) were compared between aseptic mechanical failure and those without failure. A forward stepwise logistic regression analysis was performed to determine any significant predictors of aseptic mechanical failure.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      There was significant differences in fixation between the aseptic mechanical failure group and those without failure, specifically in the number of screws for proximal fixation (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.008) and distal fixation (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.040). In the aseptic mechanical failure group, patients tended to have less than\u2009&lt;\u20098 cortices of proximal fixation (82%) and less than\u2009&lt;\u20098 cortices of distal fixation (64%). Conversely, in patients without mechanical failure there was a tendency to have greater than\u2009&gt;\u20098 cortices in both the proximal (62%) and distal fixation (70%). A forward stepwise logistic regression analysis found that less than\u2009&lt;\u20098 cortices of proximal fixation was a significant predictor of aseptic failure, OR 7.96 (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.011). We think this can be accounted for due to the variable bone quality, thinner cortices and multiple torsional forces in the proximal shaft that may warrant special consideration for fixation.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The current dogma of humeral shaft fracture stabilization is to use a minimum of 3 screws proximal and distal to the fracture, however the current study demonstrates this is associated with higher rates of mechanical failure. In contrast, 4 bicortical screws or more of fixation on either side of the fracture had lower failure rates and may help to reduce the risk of mechanical failure.<\/jats:p>\n                    <jats:p>\n                      <jats:italic>Level of Evidence<\/jats:italic>\n                      Level III.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s13018-023-03566-2","type":"journal-article","created":{"date-parts":[[2023,2,26]],"date-time":"2023-02-26T23:16:48Z","timestamp":1677453408000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Inadequate proximal screw fixation increases risk of failure following plate fixation of diaphyseal humerus fractures"],"prefix":"10.1186","volume":"18","author":[{"given":"Manisha R.","family":"Mistry","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jimmy","family":"Tat","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rafi","family":"Husain","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ujash","family":"Sheth","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robin R.","family":"Richards","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Diane","family":"Nam","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,2,27]]},"reference":[{"key":"3566_CR1","first-page":"257","volume":"51","author":"A Sarmiento","year":"2002","unstructured":"Sarmiento A, Waddell JP, Latta LL. Diaphyseal humeral fractures: treatment options. Instr Course Lect. 2002;51:257\u201369.","journal-title":"Instr Course Lect"},{"key":"3566_CR2","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1007\/s10195-017-0459-6","volume":"18","author":"BS Schoch","year":"2017","unstructured":"Schoch BS, Padegimas EM, Maltenfort M, Krieg J, Namdari S. Humeral shaft fractures: national trends in management. J Orthop Traumatol. 2017;18:259\u201363.","journal-title":"J Orthop Traumatol"},{"key":"3566_CR3","doi-asserted-by":"crossref","unstructured":"Attum B, Obremskey W. Treatment of humeral shaft fractures: a critical analysis review. JBJS Rev. 2015;3(9).","DOI":"10.2106\/JBJS.RVW.N.00119"},{"key":"3566_CR4","doi-asserted-by":"publisher","first-page":"e71","DOI":"10.2106\/JBJS.15.01049","volume":"98","author":"MB Gottschalk","year":"2016","unstructured":"Gottschalk MB, Carpenter W, Hiza E, Reisman W, Roberson J. Humeral shaft fracture fixation: incidence rates and complications as reported by American Board of Orthopaedic Surgery Part II Candidates. J Bone Joint Surg Am. 2016;98:e71.","journal-title":"J Bone Joint Surg Am"},{"issue":"4","key":"3566_CR5","doi-asserted-by":"publisher","first-page":"734","DOI":"10.1016\/j.jseint.2020.06.009","volume":"4","author":"JJ Olson","year":"2020","unstructured":"Olson JJ, Entezari V, Vallier HA. Risk factors for nonunion after traumatic humeral shaft fractures in adults. JSES Int. 2020;4(4):734\u20138.","journal-title":"JSES Int"},{"key":"3566_CR6","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1097\/BOT.0b013e3181bdd1da","volume":"24","author":"DJ Hak","year":"2010","unstructured":"Hak DJ, Althausen P, Hazelwood SJ. Locked plate fixation of osteoporotic humeral shaft fractures: Are two locking screws per segment enough? J Orthop Trauma. 2010;24:207\u201311.","journal-title":"J Orthop Trauma"},{"key":"3566_CR7","doi-asserted-by":"publisher","first-page":"1310","DOI":"10.1007\/s11999-013-3379-7","volume":"472","author":"V Kosmopoulos","year":"2014","unstructured":"Kosmopoulos V, Nana AD. Dual plating of humeral shaft fractures: orthogonal plates biomechanically outperform side-by-side plates. Clin Orthop Relat Res. 2014;472:1310\u20137.","journal-title":"Clin Orthop Relat Res"},{"key":"3566_CR8","doi-asserted-by":"crossref","unstructured":"Denard A, Richards JE, Obremskey WT, Tucker MC, Floyd M, Herzog GA. Outcome of nonoperative vs operative treatment of humeral shaft fractures: a retrospective study of 213 patients. Orthopedics. 2010;33.","DOI":"10.3928\/01477447-20100625-16"},{"key":"3566_CR9","first-page":"141","volume":"11","author":"SM Hosseini Khameneh","year":"2019","unstructured":"Hosseini Khameneh SM, Abbasian M, Abrishamkarzadeh H, et al. Humeral shaft fracture: a randomized controlled trial of nonoperative versus operative management (plate fixation). Orthop Res Rev. 2019;11:141\u20137.","journal-title":"Orthop Res Rev"},{"key":"3566_CR10","doi-asserted-by":"publisher","first-page":"278","DOI":"10.1097\/00005373-200008000-00014","volume":"49","author":"EM Tingstad","year":"2000","unstructured":"Tingstad EM, Wolinsky PR, Shyr Y, Johnson KD. Effect of immediate weightbearing on plated fractures of the humeral shaft. J Trauma. 2000;49:278\u201380.","journal-title":"J Trauma"},{"key":"3566_CR11","doi-asserted-by":"publisher","first-page":"300","DOI":"10.1097\/BOT.0b013e3181df968c","volume":"25","author":"R Patel","year":"2011","unstructured":"Patel R, Neu CP, Curtiss S, Fyhrie DP, Yoo B. Crutch weightbearing on comminuted humeral shaft fractures: a biomechanical comparison of large versus small fragment fixation for humeral shaft fractures. J Orthop Trauma. 2011;25:300\u20135.","journal-title":"J Orthop Trauma"},{"key":"3566_CR12","doi-asserted-by":"publisher","first-page":"117","DOI":"10.1007\/s10195-014-0290-2","volume":"15","author":"AK Singh","year":"2014","unstructured":"Singh AK, Narsaria N, Seth RR, Garg S. Plate osteosynthesis of fractures of the shaft of the humerus: comparison of limited contact dynamic compression plates and locking compression plates. J Orthop Traumatol. 2014;15:117\u201322.","journal-title":"J Orthop Traumatol"},{"key":"3566_CR13","doi-asserted-by":"publisher","first-page":"709","DOI":"10.1097\/BOT.0b013e31818df8cb","volume":"22","author":"RV O'Toole","year":"2008","unstructured":"O\u2019Toole RV, Andersen RC, Vesnovsky O, et al. Are locking screws advantageous with plate fixation of humeral shaft fractures? A biomechanical analysis of synthetic and cadaveric bone. J Orthop Trauma. 2008;22:709\u201315.","journal-title":"J Orthop Trauma"},{"key":"3566_CR14","doi-asserted-by":"publisher","first-page":"432","DOI":"10.1016\/j.aott.2016.07.002","volume":"50","author":"A Karakasli","year":"2016","unstructured":"Karakasli A, Basci O, Ertem F, Sekik E, Havitcioglu H. Dual plating for fixation of humeral shaft fractures: a mechanical comparison of various combinations of plate lengths. Acta Orthop Traumatol Turc. 2016;50:432\u20136.","journal-title":"Acta Orthop Traumatol Turc"},{"issue":"Suppl 2","key":"3566_CR15","doi-asserted-by":"publisher","first-page":"B63","DOI":"10.1016\/j.injury.2003.09.026","volume":"34","author":"E Gautier","year":"2003","unstructured":"Gautier E, Sommer C. Guidelines for the clinical application of the LCP. Injury. 2003;34(Suppl 2):B63-76.","journal-title":"Injury"},{"key":"3566_CR16","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1111\/joa.12903","volume":"234","author":"F Hik","year":"2019","unstructured":"Hik F, Ackland DC. The moment arms of the muscles spanning the glenohumeral joint: a systematic review. J Anat. 2019;234:1\u201315.","journal-title":"J Anat"},{"key":"3566_CR17","doi-asserted-by":"publisher","first-page":"611","DOI":"10.1302\/0301-620X.85B4.12843","volume":"85","author":"MJ Tingart","year":"2003","unstructured":"Tingart MJ, Apreleva M, von Stechow D, Zurakowski D, Warner JJ. The cortical thickness of the proximal humeral diaphysis predicts bone mineral density of the proximal humerus. J Bone Joint Surg Br. 2003;85:611\u20137.","journal-title":"J Bone Joint Surg Br"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-023-03566-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13018-023-03566-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-023-03566-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,2,26]],"date-time":"2023-02-26T23:19:42Z","timestamp":1677453582000},"score":1,"resource":{"primary":{"URL":"https:\/\/josr-online.biomedcentral.com\/articles\/10.1186\/s13018-023-03566-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,2,27]]},"references-count":17,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["3566"],"URL":"https:\/\/doi.org\/10.1186\/s13018-023-03566-2","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-1738653\/v1","asserted-by":"object"}]},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,2,27]]},"assertion":[{"value":"8 June 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 January 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 February 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Yes.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Yes, all authors provide consent for publication.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"All authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"142"}}