{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,12]],"date-time":"2026-02-12T12:21:59Z","timestamp":1770898919324,"version":"3.50.1"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,3,28]],"date-time":"2023-03-28T00:00:00Z","timestamp":1679961600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,3,28]],"date-time":"2023-03-28T00:00:00Z","timestamp":1679961600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"the 3D-printing research project of Guangdong Second Provincial General Hospital","award":["3D-A2020006"],"award-info":[{"award-number":["3D-A2020006"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Preoperatively evaluating the feasibility of safe C2 pedicle screw placement is the key to avoiding iatrogenic vertebral artery injury. However, it has not been verified whether the conventional CT measurements of C2 pediculoisthmic component (PIC) are reliable and accurate, and the results may lack validity. The purpose of this study is to analyze the evaluative performance of conventional CT measurements and to create an accurate predictor of morphometrics of C2 PIC.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>A total of 304 C2 PICs were measured in 152 consecutive patients who underwent CT examination of the cervical spine between April 2020 and December 2020. We obtained the morphometric parameters of C2 PIC by measuring minimum PIC diameter (MPD) in CT multiplanar reconstruction versus conventional measurements of transverse PIC width (TPW), oblique PIC width (OPW) and definition of high-riding vertebral artery (HRVA). The outer diameter measured less than 4\u00a0mm in MPD was regarded as the standard of precluding safe C2 pedicle screw insertion. The evaluative performance of the conventional CT measurements was assessed, and the correlation between conventional CT measurements and measurements in CT multiplanar reconstruction was calculated.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The parameters in OPW and MPD were measured significantly larger than those in TPW, and the preclusion of C2 pedicle screw placement evaluated from TPW and HRVA was significantly higher than that evaluated from OPW and MPD. The sensitivity of TPW was 93.09%, and the specificity was 79.31%. The sensitivity and specificity of OPW were 97.82% and 82.76%. The sensitivity of HRVA was 88.36%, and the specificity was 96.55%. Strong agreement with the highest correlation coefficient (0.879) and determination coefficient (0.7720) suggested that the outer diameter of OPW could be useful for the precise prediction of MPD.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>CT MPR allows accurate measurement of the narrowest section of the C2 PIC. The outer diameter of OPW could be simply measured and be useful for precise prediction of MPD, which makes C2 pedicle screw placement more safely than the conventional measurement of TPW and HRVA.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s13018-023-03727-3","type":"journal-article","created":{"date-parts":[[2023,3,28]],"date-time":"2023-03-28T03:35:37Z","timestamp":1679974537000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Morphology analysis of the C2 pediculoisthmic component and feasibility of safe C2 pedicle screw placement: comparison of multiplanar reconstruction versus traditional radiographic methods"],"prefix":"10.1186","volume":"18","author":[{"given":"YueLin","family":"Wu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"ZhaoQuan","family":"Liang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"JunHao","family":"Bao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ling","family":"Wen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Li","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2023,3,28]]},"reference":[{"issue":"1\u20132","key":"3727_CR1","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1007\/BF01400872","volume":"129","author":"A Goel","year":"1994","unstructured":"Goel A, Laheri V. Plate and screw fixation for atlanto-axial subluxation. Acta Neurochir (Wien). 1994;129(1\u20132):47\u201353.","journal-title":"Acta Neurochir (Wien)"},{"issue":"22","key":"3727_CR2","doi-asserted-by":"publisher","first-page":"2467","DOI":"10.1097\/00007632-200111150-00014","volume":"26","author":"J Harms","year":"2001","unstructured":"Harms J, Melcher RP. Posterior C1\u2013C2 fusion with polyaxial screw and rod fixation. Spine (Phila Pa 1976). 2001;26(22):2467\u201371.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"5","key":"3727_CR3","doi-asserted-by":"publisher","first-page":"409","DOI":"10.3171\/spi.2005.3.5.0409","volume":"3","author":"NM Wright","year":"2005","unstructured":"Wright NM. Translaminar rigid screw fixation of the axis. J Neurosurg Spine. 2005;3(5):409\u201314.","journal-title":"J Neurosurg Spine"},{"issue":"6","key":"3727_CR4","doi-asserted-by":"publisher","first-page":"961","DOI":"10.3171\/jns.1997.86.6.0961","volume":"86","author":"AA Madawi","year":"1997","unstructured":"Madawi AA, Casey AT, Solanki GA, Tuite G, Veres R, Crockard HA. Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique. J Neurosurg. 1997;86(6):961\u20138.","journal-title":"J Neurosurg"},{"issue":"15","key":"3727_CR5","doi-asserted-by":"publisher","first-page":"E513","DOI":"10.1097\/01.brs.0000224516.29747.52","volume":"31","author":"M Yoshida","year":"2006","unstructured":"Yoshida M, Neo M, Fujibayashi S, Nakamura T. Comparison of the anatomical risk for vertebral artery injury associated with the C2-pedicle screw and atlantoaxial transarticular screw. Spine (Phila Pa 1976). 2006;31(15):E513-7.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"1","key":"3727_CR6","doi-asserted-by":"publisher","first-page":"E12","DOI":"10.1097\/BRS.0000000000000063","volume":"39","author":"BW Su","year":"2014","unstructured":"Su BW, Shimer AL, Chinthakunta S, et al. Comparison of fatigue strength of C2 pedicle screws, C2 pars screws, and a hybrid construct in C1\u2013C2 fixation. Spine (Phila Pa 1976). 2014;39(1):E12-9.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"9","key":"3727_CR7","doi-asserted-by":"publisher","first-page":"960","DOI":"10.1097\/BRS.0b013e31816c915b","volume":"33","author":"RA Lehman Jr","year":"2008","unstructured":"Lehman RA Jr, Dmitriev AE, Helgeson MD, Sasso RC, Kuklo TR, Riew KD. Salvage of C2 pedicle and pars screws using the intralaminar technique: a biomechanical analysis. Spine (Phila Pa 1976). 2008;33(9):960\u20135.","journal-title":"Spine (Phila Pa 1976)"},{"key":"3727_CR8","doi-asserted-by":"publisher","first-page":"40","DOI":"10.4103\/sni.sni_438_17","volume":"9","author":"D Yin","year":"2018","unstructured":"Yin D, Oh G, Neckrysh S. Axial and oblique C2 pedicle diameters and feasibility of C2 pedicle screw placement: Technical note. Surg Neurol Int. 2018;9:40.","journal-title":"Surg Neurol Int"},{"issue":"1","key":"3727_CR9","doi-asserted-by":"publisher","first-page":"150","DOI":"10.1227\/00006123-199507000-00026","volume":"37","author":"ST Dull","year":"1995","unstructured":"Dull ST, Toselli RM. Preoperative oblique axial computed tomographic imaging for C1\u2013C2 transarticular screw fixation: technical note. Neurosurgery. 1995;37(1):150.","journal-title":"Neurosurgery"},{"issue":"7","key":"3727_CR10","doi-asserted-by":"publisher","first-page":"666","DOI":"10.1097\/01.BRS.0000051919.14927.57","volume":"28","author":"M Neo","year":"2003","unstructured":"Neo M, Matsushita M, Iwashita Y, Yasuda T, Sakamoto T, Nakamura T. Atlantoaxial transarticular screw fixation for a high-riding vertebral artery. Spine (Phila Pa 1976). 2003;28(7):666\u201370.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"9","key":"3727_CR11","doi-asserted-by":"publisher","first-page":"1230","DOI":"10.1007\/s00586-008-0725-7","volume":"17","author":"JP Sieradzki","year":"2008","unstructured":"Sieradzki JP, Karaikovic EE, Lautenschlager EP, Lazarus ML. Preoperative imaging of cervical pedicles: comparison of accuracy of oblique radiographs versus axial CT scans. Eur Spine J. 2008;17(9):1230\u20136.","journal-title":"Eur Spine J"},{"issue":"7","key":"3727_CR12","doi-asserted-by":"publisher","first-page":"775","DOI":"10.1016\/j.spinee.2013.04.005","volume":"13","author":"JS Yeom","year":"2013","unstructured":"Yeom JS, Buchowski JM, Kim H-J, Chang B-S, Lee C-K, Riew KD. Risk of vertebral artery injury: comparison between C1\u2013C2 transarticular and C2 pedicle screws. Spine J. 2013;13(7):775\u201385.","journal-title":"Spine J"},{"key":"3727_CR13","doi-asserted-by":"publisher","first-page":"e282","DOI":"10.1016\/j.wneu.2018.08.052","volume":"120","author":"M Agrawal","year":"2018","unstructured":"Agrawal M, Devarajan LJ, Singh PK, Garg A, Kale SS. Proposal of a new safety margin for placement of C2 pedicle screws on computed tomography angiography. World Neurosurg. 2018;120:e282\u20139.","journal-title":"World Neurosurg"},{"issue":"1","key":"3727_CR14","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1007\/s00586-012-2417-6","volume":"22","author":"F Yuan","year":"2013","unstructured":"Yuan F, Yang HL, Guo KJ, et al. A clinical morphologic study of the C2 pedicle and isthmus. Eur Spine J. 2013;22(1):39\u201345.","journal-title":"Eur Spine J"},{"key":"3727_CR15","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1016\/j.jocn.2015.11.026","volume":"29","author":"S Maki","year":"2016","unstructured":"Maki S, Koda M, Iijima Y, et al. Medially-shifted rather than high-riding vertebral arteries preclude safe pedicle screw insertion. J Clin Neurosci. 2016;29:169\u201372.","journal-title":"J Clin Neurosci"},{"issue":"2","key":"3727_CR16","doi-asserted-by":"publisher","first-page":"75","DOI":"10.4103\/0974-8237.181826","volume":"7","author":"LMS Marques","year":"2016","unstructured":"Marques LMS, d\u2019Almeida GN, Cabral J. \u201cTwo-step\u201d technique with OsiriX\u2122 to evaluate feasibility of C2 pedicle for surgical fixation. J Craniovertebr Junction Spine. 2016;7(2):75\u201381.","journal-title":"J Craniovertebr Junction Spine"},{"issue":"1","key":"3727_CR17","doi-asserted-by":"publisher","first-page":"46","DOI":"10.4103\/jcvjs.JCVJS_116_18","volume":"10","author":"CT Davidson","year":"2019","unstructured":"Davidson CT, Bergin PF, Varney ET, Jones LC, Ward MS. Planning C2 pedicle screw placement with multiplanar reformatted cervical spine computed tomography. J Craniovertebr Junction Spine. 2019;10(1):46\u201350.","journal-title":"J Craniovertebr Junction Spine"},{"issue":"1 Suppl","key":"3727_CR18","first-page":"74","volume":"95","author":"O Bloch","year":"2001","unstructured":"Bloch O, Holly LT, Park J, Obasi C, Kim K, Johnson JP. Effect of frameless stereotaxy on the accuracy of C1\u20132 transarticular screw placement. J Neurosurg. 2001;95(1 Suppl):74\u20139.","journal-title":"J Neurosurg"},{"issue":"6","key":"3727_CR19","doi-asserted-by":"publisher","first-page":"521","DOI":"10.1097\/00002517-199812000-00012","volume":"11","author":"NA Ebraheim","year":"1998","unstructured":"Ebraheim NA, Xu R, Lin D, Haman S, Yeasting RA. Quantitative anatomy of the transverse foramen and pedicle of the axis. J Spinal Disord. 1998;11(6):521\u20135.","journal-title":"J Spinal Disord"},{"issue":"12","key":"3727_CR20","doi-asserted-by":"publisher","first-page":"1542","DOI":"10.1097\/00007632-200006150-00014","volume":"25","author":"IM Mandel","year":"2000","unstructured":"Mandel IM, Kambach BJ, Petersilge CA, Johnstone B, Yoo JU. Morphologic considerations of C2 isthmus dimensions for the placement of transarticular screws. Spine (Phila Pa 1976). 2000;25(12):1542\u20137.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"3","key":"3727_CR21","doi-asserted-by":"publisher","first-page":"306","DOI":"10.3171\/spi.2004.1.3.0306","volume":"1","author":"S Naderi","year":"2004","unstructured":"Naderi S, Arman C, G\u00fcven\u00e7er M, et al. An anatomical study of the C-2 pedicle. J Neurosurg Spine. 2004;1(3):306\u201310.","journal-title":"J Neurosurg Spine"},{"issue":"4","key":"3727_CR22","doi-asserted-by":"publisher","first-page":"367","DOI":"10.1097\/00007632-198904000-00004","volume":"14","author":"GR Misenhimer","year":"1989","unstructured":"Misenhimer GR, Peek RD, Wiltse LL, Rothman SL, Widell EH Jr. Anatomic analysis of pedicle cortical and cancellous diameter as related to screw size. Spine (Phila Pa 1976). 1989;14(4):367\u201372.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"1","key":"3727_CR23","first-page":"192","volume":"32","author":"A Karaka\u015fl\u0131","year":"2021","unstructured":"Karaka\u015fl\u0131 A, Acar N, H\u00fcsemo\u011flu RB. Biomechanical comparison of pullout strengths of six pedicle screws with different thread designs. Jt Dis Relat Surg. 2021;32(1):192\u20137.","journal-title":"Jt Dis Relat Surg"},{"issue":"6","key":"3727_CR24","doi-asserted-by":"publisher","first-page":"564","DOI":"10.3171\/2013.2.SPINE12798","volume":"18","author":"LM Burke","year":"2013","unstructured":"Burke LM, Yu WD, Ho A, Wagner T, O\u2019Brien JR. Anatomical feasibility of C-2 pedicle screw fixation: the effect of variable angle interpolation of axial CT scans. J Neurosurg Spine. 2013;18(6):564\u20137.","journal-title":"J Neurosurg Spine"},{"issue":"3","key":"3727_CR25","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1097\/00007632-199502000-00001","volume":"20","author":"R Xu","year":"1995","unstructured":"Xu R, Nadaud MC, Ebraheim NA, Yeasting RA. Morphology of the second cervical vertebra and the posterior projection of the C2 pedicle axis. Spine (Phila Pa 1976). 1995;20(3):259\u201363.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"1","key":"3727_CR26","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1186\/s13018-023-03498-x","volume":"18","author":"Y Wu","year":"2023","unstructured":"Wu Y, Liang Z, Bao J, Wen L, Zhang L. C2 pedicle screw placement on 3D-printed models for the performance assessment of CTA-based screw preclusion. J Orthop Surg Res. 2023;18(1):7.","journal-title":"J Orthop Surg Res"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-023-03727-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13018-023-03727-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-023-03727-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,3,28]],"date-time":"2023-03-28T03:35:56Z","timestamp":1679974556000},"score":1,"resource":{"primary":{"URL":"https:\/\/josr-online.biomedcentral.com\/articles\/10.1186\/s13018-023-03727-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,3,28]]},"references-count":26,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["3727"],"URL":"https:\/\/doi.org\/10.1186\/s13018-023-03727-3","relation":{},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,3,28]]},"assertion":[{"value":"10 May 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 March 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 March 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was approved by the Committee of Guangdong Second Provincial General Hospital, Guangzhou, China.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Consent to publish was obtained from the patient detailed in this study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no conflict of interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"252"}}