{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T16:23:29Z","timestamp":1792167809205,"version":"4.4.0"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,4,12]],"date-time":"2023-04-12T00:00:00Z","timestamp":1681257600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,4,12]],"date-time":"2023-04-12T00:00:00Z","timestamp":1681257600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100008375","name":"University of Basel","doi-asserted-by":"crossref","id":[{"id":"10.13039\/100008375","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Bone functional adaptation rationalises the inhomogeneous morphology found in bone. By means of computed tomography osteoabsorptiometry and micro-computed tomography, the mineralisation of the subchondral endplates and trabecular microstructure of vertebral bodies can be assessed to visualise the chronic loading conditions bone endures over time. In this study, we determined cancellous and compartment-specific trabecular architecture in the cervical vertebra to aid with successful integration of orthopaedic implants.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>We examined the micro-computed tomography scans of seven prospectively healthy C4 vertebrae, evaluated their microstructure parameters (bone volume fraction (BV\/TV), bone surface density (BS\/BV), trabecular thickness (Tb.Th), trabecular separation (Tb.Sp), trabecular number per volume (Tb.N), connectivity density (Conn.D), structure model index (SMI), and degree of anisotropy (DA), and compared the trabecular architecture in twelve predefined volumes of interest: the cranial and caudal 0\u201310%, 10\u201315%, and 25\u201350% in both the ventral and dorsal half. Using computed tomography osteoabsorptiometry, the subchondral bone mineralisation of the subchondral endplates of nine C4 vertebrae was also evaluated.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Highest mineralisation is located dorsally at the endplates. Tb.Sp and Tb.N were the only two parameters that displayed significant differences in averaged values of VOI. Nonetheless, distinct, consistent ventral\u2013dorsal modulations were seen in matched sample ventral\u2013dorsal comparison in the BV\/TV, BS\/BV, and SMI overall levels, as well as in Tb.Th in the three caudal levels. To simplify, the vertebra was split into ventral\u2013cranial, dorsal\u2013cranial, ventral\u2013caudal, and dorsal\u2013caudal equal quarters. The ventral quarters display lower BV\/TV, respectively, higher BS\/BV and SMI than their sample paired dorsal quarters. The ventral\u2013cranial quarter shows the lowest BV\/TV and the highest BS\/BV and SMI, describing spacious cancellous bone with rod-like trabeculae. In contrast, the dorsal\u2013caudal quarter exhibits the highest BV\/TV and Tb.Th and the lowest BS\/BV and SMI, illustrating thicker, denser, and more plate-like trabeculae. The dorsal\u2013cranial and ventral\u2013caudal quarters are comparable and represent intermediate characteristics.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>CT-OAM and \u00b5CT demonstrate the interdependence of compact and trabecular bone in response to long-term loading conditions. Results show highest mineralisation in the dorso-caudal part of the C4 vertebra. Recommended placement of orthopaedic implants should be positioned dorsally with screws anchored in the dorsal\u2013caudal region.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s13018-023-03760-2","type":"journal-article","created":{"date-parts":[[2023,4,12]],"date-time":"2023-04-12T09:03:06Z","timestamp":1681290186000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["The quantification of 3D-trabecular architecture of the fourth cervical vertebra using CT osteoabsorptiometry and micro-CT"],"prefix":"10.1186","volume":"18","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1835-4344","authenticated-orcid":false,"given":"Am\u00e9lie","family":"Poilliot","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0959-0150","authenticated-orcid":false,"given":"Max Hans-Peter","family":"Gay-Dujak","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4875-1685","authenticated-orcid":false,"given":"Magdalena","family":"M\u00fcller-Gerbl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,4,12]]},"reference":[{"issue":"2","key":"3760_CR1","doi-asserted-by":"publisher","first-page":"298","DOI":"10.1007\/s00586-013-3039-3","volume":"23","author":"R Campos","year":"2014","unstructured":"Campos R, Botelho R. Systematic review of the effect of dynamic fixation systems compared with rigid fixation in the anterior cervical spine. Eur Spine J. 2014;23(2):298\u2013304.","journal-title":"Eur Spine J"},{"issue":"7","key":"3760_CR2","doi-asserted-by":"publisher","first-page":"751","DOI":"10.1177\/2192568218759940","volume":"8","author":"AF Joaquim","year":"2018","unstructured":"Joaquim AF, Mudo ML, Tan LA, Riew KD. Posterior subaxial cervical spine screw fixation: a review of techniques. Glob Spine J. 2018;8(7):751\u201360.","journal-title":"Glob Spine J"},{"issue":"7","key":"3760_CR3","doi-asserted-by":"publisher","first-page":"E413","DOI":"10.1097\/BRS.0000000000002441","volume":"43","author":"JD Oliver","year":"2018","unstructured":"Oliver JD, Goncalves S, Kerezoudis P, Alvi MA, Freedman BA, Nassr A, Bydon M. Comparison of outcomes for anterior cervical discectomy and fusion with and without anterior plate fixation a systematic review and meta-analysis. Spine. 2018;43(7):E413\u201322.","journal-title":"Spine"},{"issue":"7","key":"3760_CR4","doi-asserted-by":"publisher","first-page":"1125","DOI":"10.1016\/j.spinee.2013.07.474","volume":"14","author":"A Veeravagu","year":"2014","unstructured":"Veeravagu A, Cole T, Jiang B, Ratliff JK. Revision rates and complication incidence in single- and multilevel anterior cervical discectomy and fusion procedures: an administrative database study. Spine J. 2014;14(7):1125\u201331.","journal-title":"Spine J"},{"issue":"4","key":"3760_CR5","doi-asserted-by":"publisher","first-page":"873","DOI":"10.1007\/s00701-018-3490-3","volume":"160","author":"I Noordhoek","year":"2018","unstructured":"Noordhoek I, Koning MT, Jacobs WCH, Vleggeert-Lankamp CLA. Incidence and clinical relevance of cage subsidence in anterior cervical discectomy and fusion: a systematic review. Acta Neurochir. 2018;160(4):873\u201380.","journal-title":"Acta Neurochir"},{"issue":"3","key":"3760_CR6","doi-asserted-by":"publisher","first-page":"432","DOI":"10.1007\/s00586-008-0601-5","volume":"17","author":"M M\u00fcller-Gerbl","year":"2008","unstructured":"M\u00fcller-Gerbl M, Weisser S, Linsenmeier U. The distribution of mineral density in the cervical vertebral endplates. Eur Spine J. 2008;17(3):432\u20138.","journal-title":"Eur Spine J"},{"issue":"1","key":"3760_CR7","doi-asserted-by":"publisher","first-page":"25","DOI":"10.5115\/acb.20.269","volume":"54","author":"G Schroder","year":"2021","unstructured":"Schroder G, Jabke B, Schulze M, Wree A, Martin H, Sahmel O, Doerell A, Kullen CM, Andresen R, Schober HC. A comparison, using X-ray micro-computed tomography, of the architecture of cancellous bone from the cervical, thoracic and lumbar spine using 240 vertebral bodies from 10 body donors. Anat Cell Biol. 2021;54(1):25\u201334.","journal-title":"Anat Cell Biol"},{"issue":"3","key":"3760_CR8","doi-asserted-by":"publisher","first-page":"301","DOI":"10.1016\/8756-3282(94)00042-5","volume":"16","author":"HJ Grote","year":"1995","unstructured":"Grote HJ, Amling M, Vogel M, Hahn M, Posl M, Delling G. Intervertebral variation in trabecular microarchitecture throughout the normal spine in relation to age. Bone. 1995;16(3):301\u20138.","journal-title":"Bone"},{"issue":"7","key":"3760_CR9","doi-asserted-by":"publisher","first-page":"507","DOI":"10.1007\/BF00351749","volume":"18","author":"M M\u00fcller-Gerbl","year":"1989","unstructured":"M\u00fcller-Gerbl M, Putz R, Hodapp N, Schulte E, Wimmer B. Computed tomography-osteoabsorptiometry for assessing the density distribution of subchondral bone as a measure of long-term mechanical adaptation in individual joints. Skelet Radiol. 1989;18(7):507\u201312.","journal-title":"Skelet Radiol"},{"issue":"6","key":"3760_CR10","doi-asserted-by":"publisher","first-page":"612","DOI":"10.1364\/JOSAA.1.000612","volume":"1","author":"LA Feldkamp","year":"1984","unstructured":"Feldkamp LA, Davis LC, Kress JW. Practical cone-beam algorithm. J Opt Soc Am A Opt Image Sci Vis. 1984;1(6):612\u20139.","journal-title":"J Opt Soc Am A Opt Image Sci Vis"},{"issue":"7","key":"3760_CR11","doi-asserted-by":"publisher","first-page":"1468","DOI":"10.1002\/jbmr.141","volume":"25","author":"ML Bouxsein","year":"2010","unstructured":"Bouxsein ML, Boyd SK, Christiansen BA, Guldberg RE, Jepsen KJ, Muller R. Guidelines for assessment of bone microstructure in rodents using micro-computed tomography. J Bone Miner Res. 2010;25(7):1468\u201386.","journal-title":"J Bone Miner Res"},{"issue":"1","key":"3760_CR12","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1080\/01495739708936692","volume":"1","author":"T Hildebrand","year":"1997","unstructured":"Hildebrand T, Ruegsegger P. Quantification of bone microarchitecture with the structure model index. Comput Methods Biomech Biomed Eng. 1997;1(1):15\u201323.","journal-title":"Comput Methods Biomech Biomed Eng"},{"issue":"4","key":"3760_CR13","doi-asserted-by":"publisher","first-page":"401","DOI":"10.1007\/s00276-019-02190-2","volume":"41","author":"S Hoechel","year":"2019","unstructured":"Hoechel S, Zwimpfer TA, Toranelli M, Muller-Gerbl M. The adaption of the bony microstructure of the human glenoid cavity as a result of long-term biomechanical loading. Surg Radiol Anat. 2019;41(4):401\u20138.","journal-title":"Surg Radiol Anat"},{"key":"3760_CR14","first-page":"III","volume":"141","author":"M M\u00fcller-Gerbl","year":"1998","unstructured":"M\u00fcller-Gerbl M. The subchondral bone plate. Adv Anat Embryol Cell Biol. 1998;141:III\u2013XI.","journal-title":"Adv Anat Embryol Cell Biol"},{"issue":"2","key":"3760_CR15","doi-asserted-by":"publisher","first-page":"174","DOI":"10.1007\/s00774-004-0557-4","volume":"23","author":"H Gong","year":"2005","unstructured":"Gong H, Zhang M, Yeung HY, Qin L. Regional variations in microstructural properties of vertebral trabeculae with aging. J Bone Miner Metab. 2005;23(2):174\u201380.","journal-title":"J Bone Miner Metab"},{"issue":"1","key":"3760_CR16","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1097\/01.brs.0000193939.99618.ee","volume":"31","author":"H Gong","year":"2006","unstructured":"Gong H, Zhang M, Qin L, Lee KK, Guo X, Shi SQ. Regional variations in microstructural properties of vertebral trabeculae with structural groups. Spine (Phila Pa 1976). 2006;31(1):24\u201332.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"4","key":"3760_CR17","doi-asserted-by":"publisher","first-page":"616","DOI":"10.1007\/s00198-005-0025-6","volume":"17","author":"M Stauber","year":"2006","unstructured":"Stauber M, Muller R. Age-related changes in trabecular bone microstructures: global and local morphometry. Osteoporos Int. 2006;17(4):616\u201326.","journal-title":"Osteoporos Int"},{"issue":"6","key":"3760_CR18","doi-asserted-by":"publisher","first-page":"946","DOI":"10.1016\/j.bone.2007.08.019","volume":"41","author":"PA Hulme","year":"2007","unstructured":"Hulme PA, Boyd SK, Ferguson SJ. Regional variation in vertebral bone morphology and its contribution to vertebral fracture strength. Bone. 2007;41(6):946\u201357.","journal-title":"Bone"},{"issue":"3","key":"3760_CR19","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1016\/8756-3282(93)90141-V","volume":"14","author":"M Vogel","year":"1993","unstructured":"Vogel M, Hahn M, Delling G. Relation between 2-dimensional and 3-dimensional architecture of trabecular bone in the human spine. Bone. 1993;14(3):199\u2013203.","journal-title":"Bone"},{"issue":"3","key":"3760_CR20","doi-asserted-by":"publisher","first-page":"273","DOI":"10.1007\/BF02010781","volume":"25","author":"AH Beddoe","year":"1978","unstructured":"Beddoe AH. A quantitative study of the structure of trabecular bone in man, rhesus monkey, beagle and miniature pig. Calcif Tissue Res. 1978;25(3):273\u201381.","journal-title":"Calcif Tissue Res"},{"key":"3760_CR21","doi-asserted-by":"publisher","first-page":"S121","DOI":"10.1007\/BF01673420","volume":"53","author":"L Mosekilde","year":"1993","unstructured":"Mosekilde L, Raisz, Reeve, Malluche, Snyder. Vertebral structure and strength in-vivo and in-vitro. Calcif Tissue Int. 1993;53:S121\u20136.","journal-title":"Calcif Tissue Int"},{"issue":"6","key":"3760_CR22","first-page":"162","volume":"13","author":"P Salmon","year":"2015","unstructured":"Salmon P, Ohlsson C, Shefelbine S, Doube M. Structure model index does not measure rods and plates in trabecular bone. Front Endocrinol (Lausanne). 2015;13(6):162.","journal-title":"Front Endocrinol (Lausanne)"},{"issue":"11","key":"3760_CR23","doi-asserted-by":"publisher","first-page":"1783","DOI":"10.1359\/jbmr.1998.13.11.1783","volume":"13","author":"YB Jiang","year":"1998","unstructured":"Jiang YB, Zhao JN, Augat P, Ouyang XL, Lu Y, Majumdar S, Genant HK. Trabecular bone mineral and calculated structure of human bone specimens scanned by peripheral quantitative computed tomography: relation to biomechanical properties. J Bone Miner Res. 1998;13(11):1783\u201390.","journal-title":"J Bone Miner Res"},{"issue":"10","key":"3760_CR24","doi-asserted-by":"publisher","first-page":"1953","DOI":"10.1016\/j.jbiomech.2010.03.013","volume":"43","author":"CM Yakacki","year":"2010","unstructured":"Yakacki CM, Poukalova M, Guldberg RE, Lin A, Saing M, Gillogly S, Gall K. The effect of the trabecular microstructure on the pullout strength of suture anchors. J Biomech. 2010;43(10):1953\u20139.","journal-title":"J Biomech"},{"issue":"2","key":"3760_CR25","doi-asserted-by":"publisher","first-page":"347","DOI":"10.1016\/j.jbiomech.2013.11.030","volume":"47","author":"R Ab-Lazid","year":"2014","unstructured":"Ab-Lazid R, Perilli E, Ryan MK, Costi JJ, Reynolds KJ. Does cancellous screw insertion torque depend on bone mineral density and\/or microarchitecture? J Biomech. 2014;47(2):347\u201353.","journal-title":"J Biomech"},{"issue":"3","key":"3760_CR26","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s41747-018-0080-3","volume":"22","author":"D Nakashima","year":"2019","unstructured":"Nakashima D, Ishii K, Nishiwaki Y, Kawana H, Jinzaki M, Matsumoto M, Nakamura M, Nagura T. Quantitative CT-based bone strength parameters for the prediction of novel spinal implant stability using resonance frequency analysis: a cadaveric study involving experimental micro-CT and clinical multislice CT. Eur Radiol Exp. 2019;22(3):1.","journal-title":"Eur Radiol Exp"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-023-03760-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13018-023-03760-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-023-03760-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,4,12]],"date-time":"2023-04-12T09:07:36Z","timestamp":1681290456000},"score":1,"resource":{"primary":{"URL":"https:\/\/josr-online.biomedcentral.com\/articles\/10.1186\/s13018-023-03760-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,4,12]]},"references-count":26,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["3760"],"URL":"https:\/\/doi.org\/10.1186\/s13018-023-03760-2","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-2307963\/v1","asserted-by":"object"}]},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,4,12]]},"assertion":[{"value":"24 November 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 March 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 April 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All procedures performed in studies involving human material were in accordance with the ethical standards of the institutional and national research committee and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards. The samples were acquired from individuals who consented to donate their bodies to research at the Ludwig Maximilian University of Munich.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"All authors certify that they have no affiliations with or involvement in any organisation or entity with any financial or non-financial interest in the subject matter or materials discussed in this manuscript.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"297"}}