{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,10]],"date-time":"2026-11-10T17:54:21Z","timestamp":1794333261336,"version":"4.9.0"},"reference-count":36,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,7,10]],"date-time":"2023-07-10T00:00:00Z","timestamp":1688947200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,7,10]],"date-time":"2023-07-10T00:00:00Z","timestamp":1688947200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Objective<\/jats:title>\n                <jats:p>Despite the studies that have investigated the reliability of Upper Extremity Functional Tests<jats:bold>(<\/jats:bold>UEFTs), the reliability of Closed Kinetic Chain Upper Extremity Stability(CKCUES), Seated Medicine Ball Throw(SMBT), push-up(PU) and Unilateral Seated Shot Put(USSP) tests in overhead athletes has yet to be assessed. The objective of this study was to determine both the relative and absolute test\u2013retest reliability of the four UEFTs in female overhead athletes.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Twenty-nine female overhead athletes (age: 26.6\u2009\u00b1\u20095.29\u00a0years) underwent the four UEFTs twice within a three- day interval. The upper limb stability was assessed through PU and CKCUES tests, while the power was assessed though SMBT and USSP tests. The Intraclass Correlation of Coefficient (ICC) was applied to assess the relative reliability. Absolute reliability was determined by calculating the Standard Error of Measurement (SEM) and the Minimal Detectable Change (MDC). Furthermore, Bland\u2013Altman plots were used to detect the agreements between the two measurements.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The relative reliability of PU, CKCUES, SMBT, and non-dominant arm USSP tests was excellent (ICC\u2009=\u20090.83, 0.80, 0.91, and 0.83, respectively). SEM was within a range of 1.69 to 1.72 for stability tests and a range of 13.61 to 52.12 for power (based on a 95% confidence interval). The MDC was 4.68 for PU and 4.75 for CKCUES test. At least four repetitions are needed to be considered a real improvement on PU and CKCUES tests. This value was 144.04, in SMBT and 59.03, 37.62\u00a0cm (dominant and non-dominant arm, respectively) in USSP tests, which represents the minimum change that must occur to be considered an athlete\u2019s progression.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>This study revealed that both the upper limb stability and power tests have acceptable relative and absolute intra-rater reliability in female overhead athletes. These can be considered as reliable tools in research and clinical settings.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s13018-023-03974-4","type":"journal-article","created":{"date-parts":[[2023,7,10]],"date-time":"2023-07-10T03:09:03Z","timestamp":1688958543000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":15,"title":["Upper extremity physical performance tests in female overhead athletes: a test\u2013retest reliability study"],"prefix":"10.1186","volume":"18","author":[{"given":"Sara","family":"Kardor","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zahra","family":"Gorji","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nastaran","family":"Ghotbi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Behrouz","family":"Attarbashi-Moghadam","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Azadeh","family":"Shadmehr","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mona","family":"Gorji","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,7,10]]},"reference":[{"issue":"4","key":"3974_CR1","doi-asserted-by":"publisher","first-page":"90","DOI":"10.3810\/psm.2011.11.1943","volume":"39","author":"KE Wilk","year":"2011","unstructured":"Wilk KE, Yenchak A, Arrigo CA, Andrews JR. The advanced throwers ten exercise program: a new exercise series for enhanced dynamic shoulder control in the overhead throwing athlete. Phys Sportsmed. 2011;39(4):90\u20137.","journal-title":"Phys Sportsmed"},{"key":"3974_CR2","unstructured":"Krishnan SG, Hawkins RJ, Warren RF. The shoulder and the overhead athlete. Lippincott Williams & Wilkins: Philadelphia; 2004."},{"issue":"2","key":"3974_CR3","first-page":"131","volume":"4","author":"G Beckham","year":"2019","unstructured":"Beckham G, Lish S, Disney C, Keebler L, DeBeliso M, Adams KJ. The reliability of the seated medicine ball throw as assessed with accelerometer instrumentation. J Phys Act Res. 2019;4(2):131\u20136.","journal-title":"J Phys Act Res"},{"issue":"1","key":"3974_CR4","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1123\/jsr.9.1.35","volume":"9","author":"TG Goldbeck","year":"2000","unstructured":"Goldbeck TG, Davies GJ. Test-retest reliability of the closed kinetic chain upper extremity stability test: a clinical field test. J Sport Rehabil. 2000;9(1):35\u201345.","journal-title":"J Sport Rehabil"},{"issue":"12","key":"3974_CR5","doi-asserted-by":"publisher","first-page":"3318","DOI":"10.1519\/JSC.0b013e3181e7259c","volume":"24","author":"RJ Negrete","year":"2010","unstructured":"Negrete RJ, Hanney WJ, Kolber MJ, Davies GJ, Ansley MK, McBride AB, et al. Reliability, minimal detectable change, and normative values for tests of upper extremity function and power. J Strength Cond Res. 2010;24(12):3318\u201325.","journal-title":"J Strength Cond Res"},{"issue":"3","key":"3974_CR6","doi-asserted-by":"publisher","first-page":"154","DOI":"10.1249\/JSR.0b013e3181a64607","volume":"8","author":"DJ Kennedy","year":"2009","unstructured":"Kennedy DJ, Visco CJ, Press J. Current concepts for shoulder training in the overhead athlete. Curr Sports Med Rep. 2009;8(3):154\u201360.","journal-title":"Curr Sports Med Rep"},{"issue":"2","key":"3974_CR7","first-page":"95","volume":"7","author":"JL Mayhew","year":"1993","unstructured":"Mayhew JL, Bemben MG, Piper FC, Ware JS, Rohrs DM, Bemben DA. Assessing bench press power in college football players: the seated shot put. J Strength Cond Res. 1993;7(2):95\u2013100.","journal-title":"J Strength Cond Res"},{"issue":"10","key":"3974_CR8","doi-asserted-by":"publisher","first-page":"789","DOI":"10.4085\/1062-6050-51.12.06","volume":"51","author":"D Borms","year":"2016","unstructured":"Borms D, Maenhout A, Cools AM. Upper quadrant field tests and isokinetic upper limb strength in overhead athletes. J Athl Train. 2016;51(10):789\u201396.","journal-title":"J Athl Train"},{"issue":"8","key":"3974_CR9","first-page":"232596712110218","volume":"9","author":"R Griffith","year":"2021","unstructured":"Griffith R, Fretes N, Bolia IK, Murray IR, Meyer J, Weber AE, et al. Return-to-sport criteria after upper extremity surgery in athletes\u2014A scoping review, part 1: rotator cuff and shoulder stabilization procedures. Orthop J Sports Med. 2021;9(8):23259671211021828.","journal-title":"Orthop J Sports Med"},{"issue":"1","key":"3974_CR10","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/1471-2474-15-1","volume":"15","author":"HT Tucci","year":"2014","unstructured":"Tucci HT, Martins J, de Carvalho SG, Camarini PMF, de Oliveira AS. Closed Kinetic Chain Upper Extremity Stability test (CKCUES test): a reliability study in persons with and without shoulder impingement syndrome. BMC Musculoskelet Disord. 2014;15(1):1\u20139.","journal-title":"BMC Musculoskelet Disord"},{"issue":"5","key":"3974_CR11","first-page":"655","volume":"10","author":"A Sciascia","year":"2015","unstructured":"Sciascia A, Uhl T. Reliability of strength and performance testing measures and their ability to differentiate persons with and without shoulder symptoms. Int J Sports Phys Ther. 2015;10(5):655.","journal-title":"Int J Sports Phys Ther"},{"issue":"4","key":"3974_CR12","doi-asserted-by":"publisher","first-page":"1071","DOI":"10.1589\/jpts.27.1071","volume":"27","author":"D-R Lee","year":"2015","unstructured":"Lee D-R, Kim LJ. Reliability and validity of the closed kinetic chain upper extremity stability test. J Phys Ther Sci. 2015;27(4):1071\u20133.","journal-title":"J Phys Ther Sci"},{"issue":"1","key":"3974_CR13","first-page":"125","volume":"12","author":"VM de Oliveira","year":"2017","unstructured":"de Oliveira VM, Pitangui AC, Nascimento VY, da Silva HA, Dos Passos MH, de Ara\u00fajo RC. Test-retest reliability of the closed kinetic chain upper extremity stability test (CKCUEST) in adolescents: reliability of CKCUEST in adolescents. Int J Sports Phys Ther. 2017;12(1):125.","journal-title":"Int J Sports Phys Ther"},{"issue":"6","key":"3974_CR14","doi-asserted-by":"publisher","first-page":"1958","DOI":"10.1519\/JSC.0b013e3181821b20","volume":"22","author":"KL Davis","year":"2008","unstructured":"Davis KL, Kang M, Boswell BB, DuBose KD, Altman SR, Binkley HM. Validity and reliability of the medicine ball throw for kindergarten children. J Strength Cond Res. 2008;22(6):1958\u201363.","journal-title":"J Strength Cond Res"},{"issue":"8","key":"3974_CR15","doi-asserted-by":"publisher","first-page":"2344","DOI":"10.1519\/JSC.0b013e3181ecd27b","volume":"25","author":"C Harris","year":"2011","unstructured":"Harris C, Wattles AP, DeBeliso M, Sevene-Adams PG, Berning JM, Adams KJ. The seated medicine ball throw as a test of upper body power in older adults. J Strength Cond Res. 2011;25(8):2344\u20138.","journal-title":"J Strength Cond Res"},{"issue":"3","key":"3974_CR16","doi-asserted-by":"publisher","first-page":"98","DOI":"10.2519\/jospt.2002.32.3.98","volume":"32","author":"SA Falsone","year":"2002","unstructured":"Falsone SA, Gross MT, Guskiewicz KM, Schneider RA. One-arm hop test: reliability and effects of arm dominance. J Orthop Sports Phys Ther. 2002;32(3):98\u2013103.","journal-title":"J Orthop Sports Phys Ther"},{"issue":"3","key":"3974_CR17","first-page":"159","volume":"2","author":"JR Roush","year":"2007","unstructured":"Roush JR, Kitamura J, Waits MC. Reference values for the closed kinetic chain upper extremity stability test (CKCUEST) for collegiate baseball players. North Am J Sports Phys Ther NAJSPT. 2007;2(3):159.","journal-title":"North Am J Sports Phys Ther NAJSPT"},{"issue":"5","key":"3974_CR18","doi-asserted-by":"publisher","first-page":"1234","DOI":"10.1519\/JSC.0b013e3182654a09","volume":"27","author":"R Van den Tillaar","year":"2013","unstructured":"Van den Tillaar R, Marques MC. Reliability of seated and standing throwing velocity using differently weighted medicine balls. J Strength Cond Res. 2013;27(5):1234\u20138.","journal-title":"J Strength Cond Res"},{"issue":"4","key":"3974_CR19","first-page":"768","volume":"17","author":"BA Stockbrugger","year":"2003","unstructured":"Stockbrugger BA, Haennel RG. Contributing factors to performance of a medicine ball explosive power test: a comparison between jump and nonjump athletes. J Strength Cond Res. 2003;17(4):768\u201374.","journal-title":"J Strength Cond Res"},{"issue":"2","key":"3974_CR20","first-page":"138","volume":"8","author":"RJ Negrete","year":"2013","unstructured":"Negrete RJ, Hanney WJ, Pabian P, Kolber MJ. Upper body push and pull strength ratio in recreationally active adults. Int J Sports Phys Ther. 2013;8(2):138.","journal-title":"Int J Sports Phys Ther"},{"issue":"1","key":"3974_CR21","first-page":"129","volume":"19","author":"JA Schulte-Edelmann","year":"2005","unstructured":"Schulte-Edelmann JA, Davies GJ, Kernozek TW, Gerberding ED. The effects of plyometric training of the posterior shoulder and elbow. J Strength Cond Res. 2005;19(1):129\u201334.","journal-title":"J Strength Cond Res"},{"issue":"6","key":"3974_CR22","first-page":"693","volume":"53","author":"M Jones","year":"2013","unstructured":"Jones M, Lorenzo D. Assessment of power, speed, and agility in athletic, preadolescent youth. J Sports Med Phys Fitness. 2013;53(6):693\u2013700.","journal-title":"J Sports Med Phys Fitness"},{"key":"3974_CR23","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1016\/j.jbmt.2021.07.018","volume":"28","author":"LGR Ferreira","year":"2021","unstructured":"Ferreira LGR, de Oliveira AS, do Carmo ND, Bueno GAS, Lemos TV, Matheus JPC, et al. Reliability and validity of the one arm hop test and seated medicine ball throw test in young adults: a cross-sectional study. J Bodywork Mov Ther. 2021;28:26\u201333. https:\/\/doi.org\/10.1016\/j.jbmt.2021.07.018.","journal-title":"J Bodywork Mov Ther"},{"issue":"7","key":"3974_CR24","doi-asserted-by":"publisher","first-page":"518","DOI":"10.2519\/jospt.2014.5004","volume":"44","author":"TL Chmielewski","year":"2014","unstructured":"Chmielewski TL, Martin C, Lentz TA, Tillman SM, Moser MW, Farmer KW, et al. Normalization considerations for using the unilateral seated shot put test in rehabilitation. J Orthopaed Sports Phys Ther. 2014;44(7):518\u201324.","journal-title":"J Orthopaed Sports Phys Ther"},{"key":"3974_CR25","unstructured":"Fleiss JL. Design and analysis of clinical experiments: Wiley; 2011."},{"issue":"7","key":"3974_CR26","doi-asserted-by":"publisher","first-page":"100","DOI":"10.3390\/sports9070100","volume":"9","author":"G Scinicarelli","year":"2021","unstructured":"Scinicarelli G, Trofenik M, Frob\u00f6se I, Wilke C. The reliability of common functional performance tests within an experimental test battery for the lower extremities. Sports. 2021;9(7):100.","journal-title":"Sports"},{"issue":"1","key":"3974_CR27","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s13102-021-00301-4","volume":"13","author":"M Degot","year":"2021","unstructured":"Degot M, Blache Y, Vigne G, Franger G, Neyton L, Rogowski I. Intra-and intersession reliability and agreement of the unilateral seated shot-put test outcome measures in healthy male athletes. BMC Sports Sci Med Rehabil. 2021;13(1):1\u20137.","journal-title":"BMC Sports Sci Med Rehabil"},{"issue":"4","key":"3974_CR28","doi-asserted-by":"publisher","first-page":"246","DOI":"10.1097\/01.bco.0000169386.23493.17","volume":"16","author":"JJ Christoforetti","year":"2005","unstructured":"Christoforetti JJ, Carroll RM. The thrower\u2019s shoulder. Curr Opin Orthop. 2005;16(4):246\u201351.","journal-title":"Curr Opin Orthop"},{"issue":"2","key":"3974_CR29","first-page":"131","volume":"4","author":"G Beckham","year":"2019","unstructured":"Beckham G, Lish S, Keebler L, Longaker C, Disney C, DeBeliso M, et al. The reliability of the seated medicine ball throw for distance. J Phys Act Res. 2019;4(2):131\u20136.","journal-title":"J Phys Act Res"},{"issue":"2","key":"3974_CR30","first-page":"97","volume":"13","author":"J Gillespie","year":"1987","unstructured":"Gillespie J, Keenum S. A validity and reliability-analysis of the seated shot put as a test of power. J Hum Mov Stud. 1987;13(2):97\u2013105.","journal-title":"J Hum Mov Stud"},{"issue":"2","key":"3974_CR31","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","volume":"15","author":"TK Koo","year":"2016","unstructured":"Koo TK, Li MY. A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med. 2016;15(2):155\u201363.","journal-title":"J Chiropr Med"},{"issue":"9","key":"3974_CR32","doi-asserted-by":"publisher","first-page":"2456","DOI":"10.1519\/JSC.0000000000003684","volume":"34","author":"NA Bohannon","year":"2020","unstructured":"Bohannon NA, Gillen ZM, Shoemaker ME, McKay BD, Gibson SM, Cramer JT. Test-retest reliability of static and countermovement power push-up tests in young male athletes. J Strength Cond Res. 2020;34(9):2456\u201364.","journal-title":"J Strength Cond Res"},{"issue":"9","key":"3974_CR33","doi-asserted-by":"publisher","first-page":"656","DOI":"10.1080\/09638280701400698","volume":"30","author":"L-J Liaw","year":"2008","unstructured":"Liaw L-J, Hsieh C-L, Lo S-K, Chen H-M, Lee S, Lin J-H. The relative and absolute reliability of two balance performance measures in chronic stroke patients. Disabil Rehabil. 2008;30(9):656\u201361.","journal-title":"Disabil Rehabil"},{"key":"3974_CR34","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1016\/j.ptsp.2019.04.017","volume":"38","author":"M Degot","year":"2019","unstructured":"Degot M, Blache Y, Vigne G, Jur\u00e9 D, Borel F, Neyton L, et al. Intrarater reliability and agreement of a modified closed kinetic chain upper extremity stability test. Phys Ther Sport. 2019;38:44\u20138.","journal-title":"Phys Ther Sport"},{"issue":"2","key":"3974_CR35","doi-asserted-by":"publisher","first-page":"210","DOI":"10.1016\/j.jesf.2023.02.003","volume":"21","author":"H-R Xu","year":"2023","unstructured":"Xu H-R, Zhang Y-H, Mao Y, Ngo TL, Zhang Q, He G, et al. Validity and reliability of upper extremity star excursion balance test in adolescent swimmers. J Exerc Sci Fit. 2023;21(2):210\u20137.","journal-title":"J Exerc Sci Fit"},{"issue":"3","key":"3974_CR36","doi-asserted-by":"publisher","first-page":"173","DOI":"10.1111\/cpf.12624","volume":"40","author":"D Henriques-Neto","year":"2020","unstructured":"Henriques-Neto D, Minderico C, Peralta M, Marques A, Sardinha LB. Test\u2013retest reliability of physical fitness tests among young athletes: the FITescola\u00ae battery. Clin Physiol Funct Imag. 2020;40(3):173\u201382.","journal-title":"Clin Physiol Funct Imag"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-023-03974-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13018-023-03974-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-023-03974-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,7,10]],"date-time":"2023-07-10T03:12:06Z","timestamp":1688958726000},"score":1,"resource":{"primary":{"URL":"https:\/\/josr-online.biomedcentral.com\/articles\/10.1186\/s13018-023-03974-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,7,10]]},"references-count":36,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["3974"],"URL":"https:\/\/doi.org\/10.1186\/s13018-023-03974-4","relation":{},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,7,10]]},"assertion":[{"value":"26 March 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 July 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 July 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was approved by the Ethic Committee of School of Rehabilitation, Tehran University of Medical Sciences. All participants signed an informed consent.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"There is no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"489"}}