{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T16:53:02Z","timestamp":1792601582481,"version":"4.5.0"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,8,22]],"date-time":"2023-08-22T00:00:00Z","timestamp":1692662400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,8,22]],"date-time":"2023-08-22T00:00:00Z","timestamp":1692662400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Unstable femoral neck fractures with medial calcar defects are difficult to manage. The optimal fixation methods for these fractures have been a subject of ongoing debate among orthopedic surgeons. In this study, three different fixation techniques for vertical, medial defected femoral neck fractures were compared.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>In this study, a biomechanical analysis was conducted to compare three fixation methods: cannulated screws (Group 1), cannulated screws combined with a medial buttress plate (Group 2), and intramedullary nails (Group 3). Synthetic composite bone models representing vertical collum femoris fractures with medial calcar defects were used. Each group consisted of seven specimens, and, to maintain consistency, a single surgeon performed the surgical procedure. Biomechanical testing involved subjecting the specimens to axial loading until failure, and the load to failure, stiffness, and displacement values were recorded. Normality was tested using the Shapiro\u2013Wilk test. One-way ANOVA and Tukey\u2019s HSD post hoc test were used for comparisons.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The difference in the load to failure values was statistically significant among the groups, with Group 2 exhibiting the highest load to failure value, followed by Group 3 and Group 1. Stiffness values were significantly higher in Group 2 than in the other groups. Displacement values were not significantly different between the groups. Fracture and displacement patterns at the point of failure varied across the groups.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>The results of this study indicate that fixation with a medial buttress plate in combination with cannulated screws provides additional biomechanical stability for vertical femoral neck fractures with medial calcar defects. Intramedullary nail fixation also demonstrated durable stability in these fractures. These findings can be used to better understand current management strategies for these challenging fractures to promote the identification of better evidence-based recommendations.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s13018-023-04100-0","type":"journal-article","created":{"date-parts":[[2023,8,22]],"date-time":"2023-08-22T06:02:10Z","timestamp":1692684130000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["A biomechanical comparison of three fixation methods for unstable femoral neck fractures with medial calcar defect"],"prefix":"10.1186","volume":"18","author":[{"given":"Emre","family":"Koraman","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yusuf","family":"Iyetin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Oguzhan","family":"Ozyaman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Muhlik","family":"Akyurek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,8,22]]},"reference":[{"key":"4100_CR1","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1186\/s13018-016-0498-3","volume":"11","author":"M Shen","year":"2016","unstructured":"Shen M, Wang C, Chen H, Rui Y-F, Zhao S. An update on the Pauwels classification. J Orthop Surg Res. 2016;11:161.","journal-title":"J Orthop Surg Res"},{"key":"4100_CR2","doi-asserted-by":"publisher","first-page":"270","DOI":"10.1097\/BOT.0000000000000014","volume":"28","author":"CA Collinge","year":"2014","unstructured":"Collinge CA, Mir H, Reddix R. Fracture morphology of high shear angle \u201cvertical\u201d femoral neck fractures in young adult patients. J Orthop Trauma. 2014;28:270\u20135.","journal-title":"J Orthop Trauma"},{"key":"4100_CR3","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1186\/s13018-018-0901-3","volume":"13","author":"Z Wang","year":"2018","unstructured":"Wang Z, Yin Y, Li Q, Sun G, Peng X, Yin H, et al. Comparison of early complications between the use of a cannulated screw locking plate and multiple cancellous screws in the treatment of displaced intracapsular hip fractures in young adults: a randomized controlled clinical trial. J Orthop Surg Res. 2018;13:201.","journal-title":"J Orthop Surg Res"},{"key":"4100_CR4","doi-asserted-by":"publisher","first-page":"429","DOI":"10.1016\/j.mehy.2015.01.029","volume":"84","author":"H Mir","year":"2015","unstructured":"Mir H, Collinge C. Application of a medial buttress plate may prevent many treatment failures seen after fixation of vertical femoral neck fractures in young adults. Med Hypotheses. 2015;84:429\u201333.","journal-title":"Med Hypotheses"},{"key":"4100_CR5","doi-asserted-by":"publisher","first-page":"2655","DOI":"10.1007\/s00068-022-01905-2","volume":"48","author":"F Migliorini","year":"2022","unstructured":"Migliorini F, Maffulli N, Trivellas M, Eschweiler J, Hildebrand F, Betsch M. Total hip arthroplasty compared to bipolar and unipolar hemiarthroplasty for displaced hip fractures in the elderly: a Bayesian network meta-analysis. Eur J trauma Emerg Surg Off Publ Eur Trauma Soc. 2022;48:2655\u201366.","journal-title":"Eur J trauma Emerg Surg Off Publ Eur Trauma Soc"},{"key":"4100_CR6","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1097\/BOT.0000000000000291","volume":"29","author":"AV Florschutz","year":"2015","unstructured":"Florschutz AV, Langford JR, Haidukewych GJ, Koval KJ. Femoral neck fractures: current management. J Orthop Trauma. 2015;29:121\u20139.","journal-title":"J Orthop Trauma"},{"issue":"Suppl 1","key":"4100_CR7","doi-asserted-by":"publisher","first-page":"S27","DOI":"10.1097\/BOT.0000000000001365","volume":"33","author":"P Augat","year":"2019","unstructured":"Augat P, Bliven E, Hackl S. Biomechanics of femoral neck fractures and implications for fixation. J Orthop Trauma. 2019;33(Suppl 1):S27-32.","journal-title":"J Orthop Trauma"},{"key":"4100_CR8","first-page":"1537","volume":"69","author":"R Zdero","year":"2010","unstructured":"Zdero R, Keast-Butler O, Schemitsch EH. A biomechanical comparison of two triple-screw methods for femoral neck fracture fixation in a synthetic bone model. J Trauma. 2010;69:1537\u201344.","journal-title":"J Trauma"},{"key":"4100_CR9","doi-asserted-by":"publisher","first-page":"454","DOI":"10.1097\/BOT.0b013e3182249bb2","volume":"25","author":"L Latta","year":"2011","unstructured":"Latta L, Milne EL, Kaimrajh DN. Building a biomechanical model. J Orthop Trauma. 2011;25:454\u20138.","journal-title":"J Orthop Trauma"},{"key":"4100_CR10","doi-asserted-by":"publisher","first-page":"1058","DOI":"10.2106\/00004623-199507000-00012","volume":"77","author":"MR Baumgaertner","year":"1995","unstructured":"Baumgaertner MR, Curtin SL, Lindskog DM, Keggi JM. The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip. J Bone Joint Surg Am. 1995;77:1058\u201364.","journal-title":"J Bone Joint Surg Am"},{"key":"4100_CR11","doi-asserted-by":"publisher","first-page":"1695","DOI":"10.1007\/s00264-010-1199-x","volume":"35","author":"M Rupprecht","year":"2011","unstructured":"Rupprecht M, Grossterlinden L, Sellenschloh K, Hoffmann M, P\u00fcschel K, Morlock M, et al. Internal fixation of femoral neck fractures with posterior comminution: a biomechanical comparison of DHS\u00ae and Intertan nail\u00ae. Int Orthop. 2011;35:1695\u2013701.","journal-title":"Int Orthop"},{"key":"4100_CR12","doi-asserted-by":"publisher","first-page":"617","DOI":"10.1016\/j.injury.2016.01.004","volume":"47","author":"JC Katthagen","year":"2016","unstructured":"Katthagen JC, Schwarze M, Warnhoff M, Voigt C, Hurschler C, Lill H. Influence of plate material and screw design on stiffness and ultimate load of locked plating in osteoporotic proximal humeral fractures. Injury. 2016;47:617\u201324.","journal-title":"Injury"},{"key":"4100_CR13","doi-asserted-by":"publisher","first-page":"395","DOI":"10.1016\/S8756-3282(97)00302-5","volume":"22","author":"P Augat","year":"1998","unstructured":"Augat P, Fan B, Lane NE, Lang TF, LeHir P, Lu Y, et al. Assessment of bone mineral at appendicular sites in females with fractures of the proximal femur. Bone. 1998;22:395\u2013402.","journal-title":"Bone"},{"key":"4100_CR14","first-page":"69","volume":"58","author":"TV Ly","year":"2009","unstructured":"Ly TV, Swiontkowski MF. Treatment of femoral neck fractures in young adults. Instr Course Lect. 2009;58:69\u201381.","journal-title":"Instr Course Lect"},{"key":"4100_CR15","doi-asserted-by":"publisher","first-page":"61","DOI":"10.2106\/JBJS.K.01081","volume":"95","author":"J-J Yang","year":"2013","unstructured":"Yang J-J, Lin L-C, Chao K-H, Chuang S-Y, Wu C-C, Yeh T-T, et al. Risk factors for nonunion in patients with intracapsular femoral neck fractures treated with three cannulated screws placed in either a triangle or an inverted triangle configuration. J Bone Joint Surg Am. 2013;95:61\u20139.","journal-title":"J Bone Joint Surg Am"},{"key":"4100_CR16","first-page":"680","volume":"36","author":"E Walker","year":"2007","unstructured":"Walker E, Mukherjee DP, Ogden AL, Sadasivan KK, Albright JA. A biomechanical study of simulated femoral neck fracture fixation by cannulated screws: effects of placement angle and number of screws. Am J Orthop (Belle Mead NJ). 2007;36:680\u20134.","journal-title":"Am J Orthop (Belle Mead NJ)"},{"key":"4100_CR17","first-page":"438","volume":"32","author":"SG Maurer","year":"2003","unstructured":"Maurer SG, Wright KE, Kummer FJ, Zuckerman JD, Koval KJ. Two or three screws for fixation of femoral neck fractures? Am J Orthop (Belle Mead NJ). 2003;32:438\u201342.","journal-title":"Am J Orthop (Belle Mead NJ)"},{"key":"4100_CR18","doi-asserted-by":"publisher","first-page":"691","DOI":"10.1016\/j.injury.2018.02.009","volume":"49","author":"Y-K Lee","year":"2018","unstructured":"Lee Y-K, Yoon B-H, Hwang JS, Cha Y-H, Kim K-C, Koo K-H. Risk factors of fixation failure in basicervical femoral neck fracture: Which device is optimal for fixation? Injury. 2018;49:691\u20136.","journal-title":"Injury"},{"key":"4100_CR19","doi-asserted-by":"publisher","first-page":"296","DOI":"10.1016\/j.injury.2008.08.009","volume":"40","author":"S Vidyadhara","year":"2009","unstructured":"Vidyadhara S, Rao SK. Cephalomedullary nails in the management of ipsilateral neck and shaft fractures of the femur\u2013one or two femoral neck screws? Injury. 2009;40:296\u2013303.","journal-title":"Injury"},{"key":"4100_CR20","doi-asserted-by":"publisher","first-page":"642","DOI":"10.1016\/j.clinbiomech.2009.06.009","volume":"24","author":"C-C Wu","year":"2009","unstructured":"Wu C-C, Tai C-L. Reconstruction interlocking nails for ipsilateral femoral neck and shaft fractures: biomechanical analysis of effect of supplementary cannulated screw on intracapsular femoral neck fracture. Clin Biomech (Bristol, Avon). 2009;24:642\u20137.","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"4100_CR21","doi-asserted-by":"publisher","first-page":"1972","DOI":"10.1007\/s11999-009-0800-3","volume":"467","author":"S Eberle","year":"2009","unstructured":"Eberle S, Gerber C, von Oldenburg G, Hungerer S, Augat P. Type of hip fracture determines load share in intramedullary osteosynthesis. Clin Orthop Relat Res. 2009;467:1972\u201380.","journal-title":"Clin Orthop Relat Res"},{"key":"4100_CR22","doi-asserted-by":"publisher","first-page":"1676","DOI":"10.1016\/j.injury.2016.03.014","volume":"47","author":"CM Hoshino","year":"2016","unstructured":"Hoshino CM, Christian MW, O\u2019Toole RV, Manson TT. Fixation of displaced femoral neck fractures in young adults: fixed-angle devices or Pauwel screws? Injury. 2016;47:1676\u201384.","journal-title":"Injury"},{"key":"4100_CR23","doi-asserted-by":"publisher","first-page":"140","DOI":"10.55095\/achot2015\/020","volume":"82","author":"Y Imren","year":"2015","unstructured":"Imren Y, Gurkan V, Bilsel K, Desteli EE, Tuna M, Gurcan C, et al. Biomechanical comparison of dynamic hip screw, proximal femoral nail, cannulated screw, and monoaxial external fixation in the treatment of basicervical femoral neck fractures. Acta Chir Orthop Traumatol Cech. 2015;82:140\u20134.","journal-title":"Acta Chir Orthop Traumatol Cech"},{"key":"4100_CR24","doi-asserted-by":"publisher","first-page":"557","DOI":"10.1177\/0300060518816185","volume":"47","author":"J Guo","year":"2019","unstructured":"Guo J, Dong W, Yin B, Jin L, Lin Z, Hou Z, et al. Intramedullary nails with cannulated screw fixation for the treatment of unstable femoral neck fractures. J Int Med Res. 2019;47:557\u201368.","journal-title":"J Int Med Res"},{"key":"4100_CR25","doi-asserted-by":"publisher","first-page":"144","DOI":"10.1097\/BOT.0000000000000205","volume":"29","author":"SC Kunapuli","year":"2015","unstructured":"Kunapuli SC, Schramski MJ, Lee AS, Popovich JMJ, Cholewicki J, Reeves NP, et al. Biomechanical analysis of augmented plate fixation for the treatment of vertical shear femoral neck fractures. J Orthop Trauma. 2015;29:144\u201350.","journal-title":"J Orthop Trauma"},{"key":"4100_CR26","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1016\/j.clinbiomech.2010.09.020","volume":"26","author":"G R\u00f6derer","year":"2011","unstructured":"R\u00f6derer G, Moll S, Gebhard F, Claes L, Krischak G. Side plate fixation vs. intramedullary nailing in an unstable medial femoral neck fracture model: a comparative biomechanical study. Clin Biomech (Bristol, Avon). 2011;26:141\u20136.","journal-title":"Clin Biomech (Bristol, Avon.)"},{"key":"4100_CR27","first-page":"625","volume":"71","author":"M Rupprecht","year":"2011","unstructured":"Rupprecht M, Grossterlinden L, Ruecker AH, de Oliveira AN, Sellenschloh K, N\u00fcchtern J, et al. A comparative biomechanical analysis of fixation devices for unstable femoral neck fractures: the Intertan versus cannulated screws or a dynamic hip screw. J Trauma. 2011;71:625\u201334.","journal-title":"J Trauma"},{"key":"4100_CR28","doi-asserted-by":"publisher","first-page":"577","DOI":"10.1007\/s00276-015-1595-4","volume":"38","author":"R Bartoska","year":"2016","unstructured":"Bartoska R, Baca V, Horak Z, Hrubina M, Skala-Rosenbaum J, Marvan J, et al. The importance of intramedullary hip nail positioning during implantation for stable pertrochanteric fractures: biomechanical analysis. Surg Radiol Anat. 2016;38:577\u201385.","journal-title":"Surg Radiol Anat"},{"key":"4100_CR29","doi-asserted-by":"publisher","first-page":"2189","DOI":"10.1016\/j.injury.2017.08.017","volume":"48","author":"Y Ye","year":"2017","unstructured":"Ye Y, Chen K, Tian K, Li W, Mauffrey C, Hak DJ. Medial buttress plate augmentation of cannulated screw fixation in vertically unstable femoral neck fractures: Surgical technique and preliminary results. Injury. 2017;48:2189\u201393.","journal-title":"Injury"},{"key":"4100_CR30","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1097\/BOT.0000000000001377","volume":"33","author":"SM Putnam","year":"2019","unstructured":"Putnam SM, Collinge CA, Gardner MJ, Ricci WM, McAndrew CM. Vascular anatomy of the medial femoral neck and implications for surface plate fixation. J Orthop Trauma. 2019;33:111\u20135.","journal-title":"J Orthop Trauma"},{"key":"4100_CR31","doi-asserted-by":"publisher","first-page":"611","DOI":"10.1302\/2633-1462.28.BJO-2021-0099.R1","volume":"2","author":"JF Kubik","year":"2021","unstructured":"Kubik JF, Bornes TD, Klinger CE, Dyke JP, Helfet DL. The effect of calcar femoral neck plating on vascularity of the femoral head and neck. Bone Jt open. 2021;2:611\u20137.","journal-title":"Bone Jt open"},{"key":"4100_CR32","doi-asserted-by":"publisher","DOI":"10.1016\/j.biopha.2019.108658","volume":"112","author":"L Tianye","year":"2019","unstructured":"Tianye L, Peng Y, Jingli X, QiuShi W, GuangQuan Z, Wei H, et al. Finite element analysis of different internal fixation methods for the treatment of Pauwels type III femoral neck fracture. Biomed Pharmacother. 2019;112: 108658.","journal-title":"Biomed Pharmacother"},{"key":"4100_CR33","doi-asserted-by":"publisher","first-page":"933","DOI":"10.1016\/S0021-9290(97)00057-2","volume":"30","author":"GN Duda","year":"1997","unstructured":"Duda GN, Schneider E, Chao EY. Internal forces and moments in the femur during walking. J Biomech. 1997;30:933\u201341.","journal-title":"J Biomech"},{"key":"4100_CR34","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1186\/s12891-022-05056-8","volume":"23","author":"C Ma","year":"2022","unstructured":"Ma C, Liu Y, Liu J, Chen L, Huang J, Luo X, et al. The role of the medial buttress plate in the treatment of Pauwels type II and III femoral neck fracture in nonelderly patients: a retrospective study and preliminary results. BMC Musculoskelet Disord. 2022;23:100.","journal-title":"BMC Musculoskelet Disord"},{"key":"4100_CR35","first-page":"11860","volume":"13","author":"A Tuxun","year":"2021","unstructured":"Tuxun A, Aila P, Mijiti M, Abulikemu M, Keremu A, Xie Z. Effects of intramedullary nailing fixation on quality of life and joint function in patients with femoral neck fractures. Am J Transl Res. 2021;13:11860\u20137.","journal-title":"Am J Transl Res"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-023-04100-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13018-023-04100-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-023-04100-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,18]],"date-time":"2023-11-18T15:31:52Z","timestamp":1700321512000},"score":1,"resource":{"primary":{"URL":"https:\/\/josr-online.biomedcentral.com\/articles\/10.1186\/s13018-023-04100-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,8,22]]},"references-count":35,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["4100"],"URL":"https:\/\/doi.org\/10.1186\/s13018-023-04100-0","relation":{},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,8,22]]},"assertion":[{"value":"2 August 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 August 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 August 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable. Approval was not required, as neither human participants nor animals were involved in this study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"614"}}