{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,12]],"date-time":"2026-11-12T18:13:34Z","timestamp":1794507214306,"version":"4.9.1"},"reference-count":50,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,2,23]],"date-time":"2024-02-23T00:00:00Z","timestamp":1708646400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,2,23]],"date-time":"2024-02-23T00:00:00Z","timestamp":1708646400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Total knee arthroplasty (TKA) with all-polyethylene tibial (APT) components has shown comparable survivorship and clinical outcomes to that with metal-backed tibial (MBT). Although MBT is more frequently implanted, APT equivalents are considered a low-cost variant for elderly patients. A biomechanical analysis was assumed to be suitable to compare the response of the periprosthetic tibia after implantation of TKA NexGen APT and MBT equivalent.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>A standardised load model was used representing the highest load achieved during level walking. The geometry and material models were created using computed tomography data. In the analysis, a material model was created that represents a patient with osteopenia.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The equivalent strain distribution in the models of cancellous bone with an APT component showed values above 1000 \u03bc\u03b5 in the area below the medial tibial section, with MBT component were primarily localised in the stem tip area. For APT variants, the microstrain values in more than 80% of the volume were in the range from 300 to 1500 \u03bc\u03b5, MBT only in less than 64% of the volume.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>The effect of APT implantation on the periprosthetic tibia was shown as equal or even superior to that of MBT despite maximum strain values occurring in different locations. On the basis of the strain distribution, the state of the bone tissue was analysed to determine whether bone tissue remodelling or remodelling would occur. Following clinical validation, outcomes could eventually modify the implant selection criteria and lead to more frequent implantation of APT components.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s13018-024-04631-0","type":"journal-article","created":{"date-parts":[[2024,2,23]],"date-time":"2024-02-23T14:06:55Z","timestamp":1708697215000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Biomechanical comparison of all-polyethylene total knee replacement and its metal-backed equivalent on periprosthetic tibia using the finite element method"],"prefix":"10.1186","volume":"19","author":[{"given":"Vasileios","family":"Apostolopoulos","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Petr","family":"Boh\u00e1\u010d","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Petr","family":"Marci\u00e1n","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lubo\u0161","family":"Nachtnebl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michal","family":"Mahdal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luk\u00e1\u0161","family":"Pazourek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tom\u00e1\u0161","family":"Tom\u00e1\u0161","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,2,23]]},"reference":[{"key":"4631_CR1","doi-asserted-by":"publisher","first-page":"2421","DOI":"10.1016\/j.arth.2017.02.077","volume":"32","author":"KA Gustke","year":"2017","unstructured":"Gustke KA, Gelbke MK. All-polyethylene tibial component use for elderly, low-demand total knee arthroplasty patients. J Arthroplasty. 2017;32:2421\u20136.","journal-title":"J Arthroplasty"},{"key":"4631_CR2","unstructured":"Robertsson O, Lidgren L, Sundberg M, W-Dahl A. The Swedish Knee arthroplasty register\u2014annual report 2020; 2020."},{"key":"4631_CR3","doi-asserted-by":"publisher","first-page":"1548","DOI":"10.2106\/JBJS.21.01251","volume":"104","author":"J Kendall","year":"2022","unstructured":"Kendall J, Pelt CE, Imlay B, Yep P, Mullen K, Kagan R. Revision risk for total knee arthroplasty polyethylene designs in patients 65 years of age or older: an analysis from the american joint replacement registry. J Bone Jt Surg. 2022;104:1548\u201353.","journal-title":"J Bone Jt Surg"},{"key":"4631_CR4","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-023-05772-3","author":"V Apostolopoulos","year":"2023","unstructured":"Apostolopoulos V, Nachtnebl L, Mahdal M, Pazourek L, Boh\u00e1\u010d P, Jan\u00ed\u010dek P, et al. Clinical outcomes and survival comparison between NexGen all-poly and its metal-backed equivalent in total knee arthroplasty. Int Orthop. 2023. https:\/\/doi.org\/10.1007\/s00264-023-05772-3.","journal-title":"Int Orthop"},{"key":"4631_CR5","doi-asserted-by":"publisher","first-page":"3620","DOI":"10.1007\/s00167-016-4168-0","volume":"25","author":"UG Longo","year":"2017","unstructured":"Longo UG, Ciuffreda M, D\u2019Andrea V, Mannering N, Locher J, Denaro V. All-polyethylene versus metal-backed tibial component in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2017;25:3620\u201336.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"4631_CR6","doi-asserted-by":"publisher","DOI":"10.1016\/j.cmpb.2022.106834","volume":"220","author":"V Apostolopoulos","year":"2022","unstructured":"Apostolopoulos V, Tom\u00e1\u0161 T, Boh\u00e1\u010d P, Marci\u00e1n P, Mahdal M, Valou\u0161ek T, et al. Biomechanical analysis of all-polyethylene total knee arthroplasty on periprosthetic tibia using the finite element method. Comput Methods Programs Biomed. 2022;220: 106834.","journal-title":"Comput Methods Programs Biomed"},{"key":"4631_CR7","doi-asserted-by":"publisher","first-page":"105446","DOI":"10.1016\/j.cmpb.2020.105446","volume":"192","author":"AZEA Arab","year":"2020","unstructured":"Arab AZEA, Merdji A, Benaissa A, Roy S, Bachir Bouiadjra B-A, Layadi K, et al. Finite-Element analysis of a lateral femoro-tibial impact on the total knee arthroplasty. Comput Methods Progr Biomed. 2020;192:105446.","journal-title":"Comput Methods Progr Biomed"},{"key":"4631_CR8","doi-asserted-by":"publisher","DOI":"10.1016\/j.cmpb.2021.106499","volume":"213","author":"E Bori","year":"2022","unstructured":"Bori E, Armaroli F, Innocenti B. Biomechanical analysis of femoral stems in hinged total knee arthroplasty in physiological and osteoporotic bone. Comput Methods Progr Biomed. 2022;213: 106499.","journal-title":"Comput Methods Progr Biomed"},{"key":"4631_CR9","unstructured":"Zimmer Biomet, NexGen\u00ae CR-Flex and LPS-Flex Knees; 2016."},{"key":"4631_CR10","doi-asserted-by":"publisher","first-page":"267","DOI":"10.3892\/etm.2021.9698","volume":"21","author":"N Gheorghiu","year":"2021","unstructured":"Gheorghiu N, Socea B, Dimitriu M, Bacalbasa N, Stan G, Orban H. A finite element analysis for predicting outcomes of cemented total knee arthroplasty. Exp Ther Med. 2021;21:267.","journal-title":"Exp Ther Med"},{"key":"4631_CR11","doi-asserted-by":"publisher","first-page":"1886","DOI":"10.1007\/s11999-016-4732-4","volume":"474","author":"MD Kohn","year":"2016","unstructured":"Kohn MD, Sassoon AA, Fernando ND. Classifications in brief: Kellgren\u2013Lawrence classification of osteoarthritis. Clin Orthop Relat Res. 2016;474:1886\u201393.","journal-title":"Clin Orthop Relat Res"},{"key":"4631_CR12","unstructured":"Australian Orthopaedic Association National Joint Replacement Registry. Annual Report. Adelaide. AOA 2020: Table KT2 10 Most Used Femoral Prostheses in Primary Total Knee Replacement."},{"key":"4631_CR13","unstructured":"Marci\u00e1n P, Konecn\u00fd O, Bor\u00e1k L, Valasek J, Rehak K, Krpalek D, Florian Z. On the level of computational models in biomechanics depending on gained data from CT\/MRI and micro-CT; 2011."},{"key":"4631_CR14","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1186\/s12891-016-0940-z","volume":"17","author":"PZ Feczko","year":"2016","unstructured":"Feczko PZ, Pijls BG, van Steijn MJ, van Rhijn LW, Arts JJ, Emans PJ. Tibial component rotation in total knee arthroplasty. BMC Musculoskelet Disord. 2016;17:87.","journal-title":"BMC Musculoskelet Disord"},{"key":"4631_CR15","doi-asserted-by":"publisher","first-page":"309","DOI":"10.1016\/j.arth.2010.03.021","volume":"26","author":"GL Hatfield","year":"2011","unstructured":"Hatfield GL, Hubley-Kozey CL, Astephen Wilson JL, Dunbar MJ. The effect of total knee arthroplasty on knee joint kinematics and kinetics during gait. J Arthroplasty. 2011;26:309\u201318.","journal-title":"J Arthroplasty"},{"key":"4631_CR16","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1186\/s12891-015-0525-2","volume":"16","author":"J Rahman","year":"2015","unstructured":"Rahman J, Tang Q, Monda M, Miles J, McCarthy I. Gait assessment as a functional outcome measure in total knee arthroplasty: a cross-sectional study. BMC Musculoskelet Disord. 2015;16:66.","journal-title":"BMC Musculoskelet Disord"},{"key":"4631_CR17","doi-asserted-by":"publisher","first-page":"295","DOI":"10.1302\/0301-620X.95B3.29586","volume":"95-B","author":"DT Cawley","year":"2013","unstructured":"Cawley DT, Kelly N, McGarry JP, Shannon FJ. Cementing techniques for the tibial component in primary total knee replacement. Bone Jt J. 2013;95-B:295\u2013300.","journal-title":"Bone Jt J"},{"key":"4631_CR18","doi-asserted-by":"publisher","DOI":"10.1115\/1.2913335","volume":"130","author":"HA Gray","year":"2008","unstructured":"Gray HA, Taddei F, Zavatsky AB, Cristofolini L, Gill HS. Experimental validation of a finite element model of a human cadaveric tibia. J Biomech Eng. 2008;130: 031016.","journal-title":"J Biomech Eng"},{"key":"4631_CR19","doi-asserted-by":"publisher","first-page":"1940","DOI":"10.1080\/02670836.2018.1469455","volume":"34","author":"FP Zaribaf","year":"2018","unstructured":"Zaribaf FP. Medical-grade ultra-high molecular weight polyethylene: past, current and future. Mater Sci Technol. 2018;34:1940\u201353.","journal-title":"Mater Sci Technol"},{"key":"4631_CR20","doi-asserted-by":"publisher","first-page":"932","DOI":"10.3390\/ma8030932","volume":"8","author":"R Osman","year":"2015","unstructured":"Osman R, Swain M. A critical review of dental implant materials with an emphasis on titanium versus zirconia. Materials. 2015;8:932\u201358.","journal-title":"Materials"},{"key":"4631_CR21","doi-asserted-by":"crossref","unstructured":"Klarstrom D, Crook P, Sharif A. Cobalt alloys: alloying and thermomechanical processing. Reference module in materials science and materials engineering [Internet]. Elsevier; 2017 [cited 2021 Sep 4]. p. B9780128035818093000. Available from: https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/B9780128035818092134","DOI":"10.1016\/B978-0-12-803581-8.09213-4"},{"key":"4631_CR22","doi-asserted-by":"crossref","unstructured":"Dunne N. Mechanical properties of bone cements. Orthopaedic Bone Cements [Internet]. Elsevier; 2008 [cited 2022 Apr 6], pp. 233\u201364. Available from: https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/B9781845693763500113","DOI":"10.1533\/9781845695170.3.233"},{"key":"4631_CR23","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2021.104393","volume":"117","author":"P Marci\u00e1n","year":"2021","unstructured":"Marci\u00e1n P, Bor\u00e1k L, Zikmund T, Hor\u00e1\u010dkov\u00e1 L, Kaiser J, Joukal M, et al. On the limits of finite element models created from (micro)CT datasets and used in studies of bone-implant-related biomechanical problems. J Mech Behav Biomed Mater. 2021;117: 104393.","journal-title":"J Mech Behav Biomed Mater"},{"key":"4631_CR24","doi-asserted-by":"publisher","first-page":"285","DOI":"10.1007\/s40846-021-00607-1","volume":"41","author":"C Rungruangbaiyok","year":"2021","unstructured":"Rungruangbaiyok C, Azari F, van Lenthe GH, Vander Sloten J, Tangtrakulwanich B, Chatpun S. Finite element investigation of fracture risk under postero-anterior mobilization on a lumbar bone in elderly with and without osteoporosis. J Med Biol Eng. 2021;41:285\u201394.","journal-title":"J Med Biol Eng"},{"key":"4631_CR25","doi-asserted-by":"publisher","first-page":"111171","DOI":"10.1016\/j.jbiomech.2022.111171","volume":"141","author":"MJ Dreyer","year":"2022","unstructured":"Dreyer MJ, Trepczynski A, Hosseini Nasab SH, Kutzner I, Sch\u00fctz P, Weisse B, et al. European society of biomechanics S.M. Perren award 2022: standardized tibio-femoral implant loads and kinematics. J Biomech. 2022;141:111171.","journal-title":"J Biomech"},{"key":"4631_CR26","doi-asserted-by":"publisher","first-page":"375","DOI":"10.1016\/j.jmbbm.2016.07.002","volume":"63","author":"M Guezmil","year":"2016","unstructured":"Guezmil M, Bensalah W, Mezlini S. Tribological behavior of UHMWPE against TiAl6V4 and CoCr28Mo alloys under dry and lubricated conditions. J Mech Behav Biomed Mater. 2016;63:375\u201385.","journal-title":"J Mech Behav Biomed Mater"},{"key":"4631_CR27","first-page":"73","volume":"2","author":"HM Frost","year":"1987","unstructured":"Frost HM. The mechanostat: a proposed pathogenic mechanism of osteoporoses and the bone mass effects of mechanical and nonmechanical agents. Bone Miner. 1987;2:73\u201385.","journal-title":"Bone Miner"},{"key":"4631_CR28","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1002\/ar.1092260402","volume":"226","author":"HM Frost","year":"1990","unstructured":"Frost HM. Skeletal structural adaptations to mechanical usage (SATMU): 1. Redefining Wolff\u2019s law: the bone modeling problem. Anat Rec. 1990;226:403\u201313.","journal-title":"Anat Rec"},{"key":"4631_CR29","doi-asserted-by":"publisher","first-page":"414","DOI":"10.1002\/ar.1092260403","volume":"226","author":"HM Frost","year":"1990","unstructured":"Frost HM. Skeletal structural adaptations to mechanical usage (SATMU): 2. Redefining Wolff\u2019s law: the remodeling problem. Anat Rec. 1990;226:414\u201322.","journal-title":"Anat Rec"},{"key":"4631_CR30","doi-asserted-by":"publisher","first-page":"2724","DOI":"10.1002\/jcb.25265","volume":"116","author":"JB Tyrovola","year":"2015","unstructured":"Tyrovola JB, Odont X. The, \u201cmechanostat theory\u201d of frost and the OPG\/RANKL\/RANK system: the \u201cmechanostat \u201d and the OPG\/RANKL\/RANK. J Cell Biochem. 2015;116:2724\u20139.","journal-title":"J Cell Biochem"},{"key":"4631_CR31","doi-asserted-by":"publisher","first-page":"2837","DOI":"10.1016\/j.arth.2020.05.017","volume":"35","author":"DR Selvan","year":"2020","unstructured":"Selvan DR, Santini AJA, Davidson JS, Pope JA. The medium-term survival analysis of an all-polyethylene tibia in a single-series cohort of over 1000 knees. J Arthroplasty. 2020;35:2837\u201342.","journal-title":"J Arthroplasty"},{"key":"4631_CR32","doi-asserted-by":"crossref","first-page":"108","DOI":"10.3113\/JSOA.2019.0108","volume":"28","author":"T Herschmiller","year":"2019","unstructured":"Herschmiller T, Bradley KE, Wellman SS, Attarian DE. Early to midterm clinical and radiographic survivorship of the all-polyethylene versus modular metal-backed tibia component in primary total knee replacement. J Surg Orthop Adv. 2019;28:108\u201314.","journal-title":"J Surg Orthop Adv"},{"key":"4631_CR33","doi-asserted-by":"publisher","first-page":"478","DOI":"10.2106\/JBJS.I.00842","volume":"92","author":"TJ Gioe","year":"2010","unstructured":"Gioe TJ, Maheshwari AV. The all-polyethylene tibial component in primary total knee arthroplasty. J Bone Jt Surg. 2010;92:478\u201387.","journal-title":"J Bone Jt Surg"},{"key":"4631_CR34","first-page":"249","volume":"32","author":"K Sabeh","year":"2018","unstructured":"Sabeh K, Alam M, Rosas S, Hussain S, Schneiderbauer M. Cost analysis of all-polyethylene compared to metal-backed implants in total knee arthroplasty. Surg Technol Int. 2018;32:249\u201355.","journal-title":"Surg Technol Int"},{"key":"4631_CR35","doi-asserted-by":"publisher","first-page":"2560","DOI":"10.1007\/s00167-015-3923-y","volume":"24","author":"SM Thompson","year":"2016","unstructured":"Thompson SM, Yohuno D, Bradley WN, Crocombe AD. Finite element analysis: a comparison of an all-polyethylene tibial implant and its metal-backed equivalent. Knee Surg Sports Traumatol Arthrosc. 2016;24:2560\u20136.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"4631_CR36","doi-asserted-by":"publisher","first-page":"2550","DOI":"10.1007\/s00167-015-3630-8","volume":"24","author":"J Brihault","year":"2016","unstructured":"Brihault J, Navacchia A, Pianigiani S, Labey L, De Corte R, Pascale V, et al. All-polyethylene tibial components generate higher stress and micromotions than metal-backed tibial components in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2016;24:2550\u20139.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"4631_CR37","unstructured":"Zimmer. Innex Knee System Primary [Internet]. 2005. Available from: https:\/\/www.zimmerbiomet.com\/content\/dam\/zimmer-web\/documents\/en-GB\/pdf\/medical-professionals\/knee\/innex-knee-system-primary-brochure.pdf"},{"key":"4631_CR38","doi-asserted-by":"publisher","first-page":"1445","DOI":"10.1177\/0954411920947204","volume":"234","author":"Q Zhang","year":"2020","unstructured":"Zhang Q, Chen Z, Zhang Z, Jin Z, Muratoglu OK, Varadarajan KM. Leveraging subject-specific musculoskeletal modeling to assess effect of anterior cruciate ligament retaining total knee arthroplasty during walking gait. Proc Inst Mech Eng H. 2020;234:1445\u201356.","journal-title":"Proc Inst Mech Eng H"},{"key":"4631_CR39","doi-asserted-by":"publisher","first-page":"779","DOI":"10.1302\/0301-620X.99B6.BJJ-2016-0713.R1","volume":"99-B","author":"I Kutzner","year":"2017","unstructured":"Kutzner I, Bender A, Dymke J, Duda G, von Roth P, Bergmann G. Mediolateral force distribution at the knee joint shifts across activities and is driven by tibiofemoral alignment. Bone Jt J. 2017;99-B:779\u201387.","journal-title":"Bone Jt J"},{"key":"4631_CR40","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1016\/j.knee.2008.01.008","volume":"15","author":"A Completo","year":"2008","unstructured":"Completo A, Sim\u00f5es JA, Fonseca F, Oliveira M. The influence of different tibial stem designs in load sharing and stability at the cement\u2013bone interface in revision TKA. Knee. 2008;15:227\u201332.","journal-title":"Knee"},{"key":"4631_CR41","doi-asserted-by":"publisher","first-page":"797","DOI":"10.1016\/j.jbiomech.2003.10.010","volume":"37","author":"KB Shelburne","year":"2004","unstructured":"Shelburne KB, Pandy MG, Anderson FC, Torry MR. Pattern of anterior cruciate ligament force in normal walking. J Biomech. 2004;37:797\u2013805. https:\/\/doi.org\/10.1016\/j.jbiomech.2003.10.010.","journal-title":"J Biomech."},{"key":"4631_CR42","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1016\/j.jbiomech.2003.07.001","volume":"37","author":"KB Shelburne","year":"2004","unstructured":"Shelburne KB, Pandy MG, Torry MR. Comparison of shear forces and ligament loading in the healthy and ACL-deficient knee during gait. J Biomech. 2004;37:313\u20139.","journal-title":"J Biomech"},{"key":"4631_CR43","doi-asserted-by":"publisher","DOI":"10.1016\/j.cmpb.2019.105109","volume":"183","author":"M Nikkhoo","year":"2020","unstructured":"Nikkhoo M, Hassani K, Tavakoli Golpaygani A, Karimi A. Biomechanical role of posterior cruciate ligament in total knee arthroplasty: a finite element analysis. Comput Methods Prog Biomed. 2020;183: 105109.","journal-title":"Comput Methods Prog Biomed"},{"key":"4631_CR44","doi-asserted-by":"publisher","DOI":"10.1115\/1.4032464","volume":"138","author":"CR Smith","year":"2016","unstructured":"Smith CR, Vignos MF, Lenhart RL, Kaiser J, Thelen DG. The influence of component alignment and ligament properties on tibiofemoral contact forces in total knee replacement. J Biomech Eng. 2016;138: 021017.","journal-title":"J Biomech Eng"},{"key":"4631_CR45","doi-asserted-by":"publisher","first-page":"211","DOI":"10.1016\/j.smhs.2020.10.002","volume":"2","author":"KD Harper","year":"2020","unstructured":"Harper KD, Clyburn TA, Incavo SJ, Lambert BS. DEXA overestimates bone mineral density in adults with knee replacements. Sports Med Health Sci. 2020;2:211\u20135.","journal-title":"Sports Med Health Sci"},{"key":"4631_CR46","doi-asserted-by":"publisher","first-page":"3957","DOI":"10.1007\/s00402-021-04297-x","volume":"142","author":"MM Delsmann","year":"2021","unstructured":"Delsmann MM, Schmidt C, M\u00fchlenfeld M, Jandl NM, Boese CK, Beil FT, et al. Prevalence of osteoporosis and osteopenia in elderly patients scheduled for total knee arthroplasty. Arch Orthop Trauma Surg. 2021;142:3957\u201364.","journal-title":"Arch Orthop Trauma Surg"},{"key":"4631_CR47","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1007\/s11914-011-0062-3","volume":"9","author":"WF Lems","year":"2011","unstructured":"Lems WF, Raterman HG, van den Bergh JPW, Bijlsma HWJ, Valk NK, Zillikens MC, et al. Osteopenia: a diagnostic and therapeutic challenge. Curr Osteoporos Rep. 2011;9:167\u201372.","journal-title":"Curr Osteoporos Rep"},{"key":"4631_CR48","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1007\/BF03324955","volume":"23","author":"A Spinarelli","year":"2011","unstructured":"Spinarelli A, Petrera M, Vicenti G, Pesce V, Patella V. Total knee arthroplasty in elderly osteoporotic patients. Aging Clin Exp Res. 2011;23:78\u201380.","journal-title":"Aging Clin Exp Res"},{"key":"4631_CR49","doi-asserted-by":"publisher","first-page":"2274","DOI":"10.1016\/j.arth.2020.04.013","volume":"35","author":"C Hanreich","year":"2020","unstructured":"Hanreich C, Martelanz L, Koller U, Windhager R, Waldstein W. Sport and physical activity following primary total knee arthroplasty: a systematic review and meta-analysis. J Arthroplasty. 2020;35:2274-2285.e1.","journal-title":"J Arthroplasty"},{"key":"4631_CR50","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1016\/j.medengphy.2004.09.010","volume":"27","author":"AG Au","year":"2005","unstructured":"Au AG, Liggins AB, Raso VJ, Amirfazli A. A parametric analysis of fixation post shape in tibial knee prostheses. Med Eng Phys. 2005;27:123\u201334.","journal-title":"Med Eng Phys"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-024-04631-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13018-024-04631-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-024-04631-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,23]],"date-time":"2024-02-23T15:10:53Z","timestamp":1708701053000},"score":1,"resource":{"primary":{"URL":"https:\/\/josr-online.biomedcentral.com\/articles\/10.1186\/s13018-024-04631-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2,23]]},"references-count":50,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["4631"],"URL":"https:\/\/doi.org\/10.1186\/s13018-024-04631-0","relation":{},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,2,23]]},"assertion":[{"value":"22 November 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 February 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 February 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Informed consent was obtained from all individual participants included in this study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"All authors consent to the publication of the study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interest.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"153"}}