{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T15:59:11Z","timestamp":1791907151480,"version":"4.3.4"},"reference-count":51,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,7,27]],"date-time":"2024-07-27T00:00:00Z","timestamp":1722038400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,7,27]],"date-time":"2024-07-27T00:00:00Z","timestamp":1722038400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"New Clinical Technology of the Army Medical University","award":["2015-2A-1-5"],"award-info":[{"award-number":["2015-2A-1-5"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Objective<\/jats:title>\n                <jats:p>The aim of this study is to evaluate the clinical efficacy of injectable cemented hollow pedicle screw (CICPS) in the treatment of osteoporotic lumbar degenerative diseases through a large sample long-term follow-up study. Additionally, we aim to explore the risk factors affecting interbody fusion.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>A total of 98 patients who underwent CICPS for transforaminal lumbar interbody fusion (TLIF) for osteoporotic lumbar degenerative disease from March 2011 to September 2017 were analyzed. X-ray and electronic computed tomography (CT) imaging data were collected during preoperative, postoperative, and follow-up periods. The data included changes in intervertebral space height (\u0394H), screw failure, cement leakage (CL), and intervertebral fusion. The patients were divided into two groups based on their fusion status one year after surgery: satisfied group A and dissatisfied group B. Surgical data such as operation time, intraoperative bleeding volume and surgical complications were recorded, and visual analog scale (VAS) and Oswestry disability index (ODI) were used to evaluate the improvement of lumbar and leg pain.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The mean follow-up time was 101.29 months (ranging from 70 to 128 months). A total of 320 CICPS were used, with 26 screws (8.13%) leaking, 3 screws (0.94%) experiencing cement augmentation failure, and 1 screw (0.31%) becoming loose and breaking. The remaining screws were not loose or pulled out. Female gender, decreased bone density, and CL were identified as risk factors affecting interbody fusion (<jats:italic>P<\/jats:italic>\u2009&lt;\u20090.05). Early realization of interbody fusion can effectively prevent the loss of intervertebral space height (<jats:italic>P<\/jats:italic>\u2009&lt;\u20090.05) and maintain the surgical treatment effect. Both VAS and ODI scores showed significant improvement during the follow-up period (<jats:italic>P<\/jats:italic>\u2009&lt;\u20090.05). Binary logistic regression analysis revealed that decreased bone density and cement leakage were risk factors for prolonged interbody fusion.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>The results of long-term follow-up indicate that PMMA enhanced CICPS has unique advantages in achieving good clinical efficacy in the treatment of osteoporosis lumbar degenerative diseases. Attention should be paid to identify female gender, severe osteoporosis, and CL as risk factors affecting interbody fusion.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s13018-024-04934-2","type":"journal-article","created":{"date-parts":[[2024,7,27]],"date-time":"2024-07-27T04:02:03Z","timestamp":1722052923000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Injectable bone cement cannulated pedicle screw for lumbar degenerative disease in osteoporosis - clinical follow-up of over 5 years"],"prefix":"10.1186","volume":"19","author":[{"given":"Cong-can","family":"Li","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiu-lun","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wen-wen","family":"Wu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rui","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yi-fan","family":"Jiang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jun","family":"Xiao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yu-Xuan","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lei","family":"Song","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fei","family":"Dai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,7,27]]},"reference":[{"key":"4934_CR1","doi-asserted-by":"publisher","first-page":"106481","DOI":"10.1016\/j.cmpb.2021.106481","volume":"212","author":"K Khalaf","year":"2021","unstructured":"Khalaf K, Nikkhoo M. Comparative biomechanical analysis of rigid vs. flexible fixation devices for the lumbar spine: a geometrically patient-specific poroelastic finite element study. Comput Methods Programs Biomed. 2021;212:106481\u201392.","journal-title":"Comput Methods Programs Biomed"},{"key":"4934_CR2","doi-asserted-by":"publisher","first-page":"1519","DOI":"10.2106\/00004623-199911000-00003","volume":"81","author":"JE Lonstein","year":"1999","unstructured":"Lonstein JE, Denis F, Perra JH, Pinto MR, Smith MD, Winter RB. Complications associated with pedicle screws. J Bone Joint Surg Am. 1999;81:1519\u201328.","journal-title":"J Bone Joint Surg Am"},{"key":"4934_CR3","doi-asserted-by":"publisher","first-page":"1655","DOI":"10.1097\/BRS.0b013e318074d604","volume":"32","author":"M Di Silvestre","year":"2007","unstructured":"Di Silvestre M, Parisini P, Lolli F, Bakaloudis G. Complications of thoracic pedicle screws in scoliosis treatment. Spine (Phila Pa 1976). 2007;32:1655\u201361.","journal-title":"Spine (Phila Pa 1976)"},{"key":"4934_CR4","doi-asserted-by":"publisher","first-page":"306","DOI":"10.1097\/01.bsd.0000090575.08296.9d","volume":"17","author":"CA Reitman","year":"2004","unstructured":"Reitman CA, Nguyen L, Fogel GR. Biomechanical evaluation of relationship of screw pullout strength, insertional torque, and bone mineral density in the cervical spine. J Spinal Disord Tech. 2004;17:306\u201311.","journal-title":"J Spinal Disord Tech"},{"key":"4934_CR5","doi-asserted-by":"publisher","first-page":"1374","DOI":"10.1097\/00007632-199806150-00015","volume":"23","author":"DW Polly Jr","year":"1998","unstructured":"Polly DW Jr, Orchowski JR, Ellenbogen RG. Revision pedicle screws. Bigger, longer shims\u2013what is best. Spine (Phila Pa 1976). 1998;23:1374\u20139.","journal-title":"Spine (Phila Pa 1976)"},{"key":"4934_CR6","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1055\/s-0033-1361588","volume":"4","author":"CA Kuhns","year":"2014","unstructured":"Kuhns CA, Reiter M, Pfeiffer F, Choma TJ. Surgical strategies to improve fixation in the osteoporotic spine: the effects of tapping, cement augmentation, and screw trajectory. Global Spine J. 2014;4:47\u201354.","journal-title":"Global Spine J"},{"key":"4934_CR7","doi-asserted-by":"publisher","first-page":"E867","DOI":"10.1097\/01.brs.0000244658.35865.59","volume":"31","author":"FM Pfeiffer","year":"2006","unstructured":"Pfeiffer FM, Abernathie DL, Smith DE. A comparison of pullout strength for pedicle screws of different designs: a study using tapped and untapped pilot holes. Spine (Phila Pa 1976). 2006;31:E867\u201370.","journal-title":"Spine (Phila Pa 1976)"},{"key":"4934_CR8","doi-asserted-by":"publisher","first-page":"402","DOI":"10.1016\/j.spinee.2003.11.010","volume":"4","author":"SD Cook","year":"2004","unstructured":"Cook SD, Salkeld SL, Stanley T, Faciane A, Miller SD. Biomechanical study of pedicle screw fixation in severely osteoporotic bone. Spine J. 2004;4:402\u20138.","journal-title":"Spine J"},{"key":"4934_CR9","doi-asserted-by":"publisher","first-page":"655","DOI":"10.2106\/00004623-197557050-00013","volume":"57","author":"HU Cameron","year":"1975","unstructured":"Cameron HU, Jacob R, Macnab I, Pilliar RM. Use of polymethylmethacrylate to enhance screw fixation in bone. J Bone Joint Surg Am. 1975;57:655\u20136.","journal-title":"J Bone Joint Surg Am"},{"key":"4934_CR10","doi-asserted-by":"publisher","first-page":"976","DOI":"10.1016\/j.wneu.2015.01.056","volume":"83","author":"S Yi","year":"2015","unstructured":"Yi S, Rim DC, Park SW, Murovic JA, Lim J, Park J. Biomechanical comparisons of pull out strengths after Pedicle Screw Augmentation with Hydroxyapatite, Calcium phosphate, or polymethylmethacrylate in the cadaveric spine. World Neurosurg. 2015;83:976\u201381.","journal-title":"World Neurosurg"},{"key":"4934_CR11","doi-asserted-by":"publisher","first-page":"3","DOI":"10.4184\/asj.2018.12.1.3","volume":"12","author":"G Kiyak","year":"2018","unstructured":"Kiyak G, Balikci T, Heydar AM, Bezer M. Comparison of the pullout strength of different pedicle screw designs and augmentation techniques in an osteoporotic bone model. Asian Spine J. 2018;12:3\u201311.","journal-title":"Asian Spine J"},{"key":"4934_CR12","doi-asserted-by":"publisher","first-page":"1432","DOI":"10.1016\/j.spinee.2015.03.016","volume":"15","author":"BD Elder","year":"2015","unstructured":"Elder BD, Lo SF, Holmes C, Goodwin CR, Kosztowski TA, Lina IA, Locke JE, Witham TF. The biomechanics of pedicle screw augmentation with cement. Spine J. 2015;15:1432\u201345.","journal-title":"Spine J"},{"key":"4934_CR13","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1007\/s00586-015-3904-3","volume":"26","author":"R Bostelmann","year":"2017","unstructured":"Bostelmann R, Keiler A, Steiger HJ, Scholz A, Cornelius JF, Schmoelz W. Effect of augmentation techniques on the failure of pedicle screws under cranio-caudal cyclic loading. Eur Spine J. 2017;26:181\u20138.","journal-title":"Eur Spine J"},{"key":"4934_CR14","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1097\/BSD.0b013e31819942cd","volume":"23","author":"T Hamasaki","year":"2010","unstructured":"Hamasaki T, Tanaka N, Kim J, Okada M, Ochi M, Hutton WC. Pedicle screw augmentation with polyethylene tape: a biomechanical study in the osteoporotic thoracolumbar spine. J Spinal Disord Tech. 2010;23:127\u201332.","journal-title":"J Spinal Disord Tech"},{"key":"4934_CR15","doi-asserted-by":"publisher","first-page":"1506","DOI":"10.1016\/j.medengphy.2013.04.007","volume":"35","author":"KH Chao","year":"2013","unstructured":"Chao KH, Lai YS, Chen WC, Chang CM, McClean CJ, Fan CY, Chang CH, Lin LC, Cheng CK. Biomechanical analysis of different types of pedicle screw augmentation: a cadaveric and synthetic bone sample study of instrumented vertebral specimens. Med Eng Phys. 2013;35:1506\u201312.","journal-title":"Med Eng Phys"},{"key":"4934_CR16","doi-asserted-by":"publisher","first-page":"1462","DOI":"10.1007\/s00586-008-0769-8","volume":"17","author":"S Becker","year":"2008","unstructured":"Becker S, Chavanne A, Spitaler R, Kropik K, Aigner N, Ogon M, Redl H. Assessment of different screw augmentation techniques and screw designs in osteoporotic spines. Eur Spine J. 2008;17:1462\u20139.","journal-title":"Eur Spine J"},{"key":"4934_CR17","doi-asserted-by":"publisher","first-page":"S305","DOI":"10.1016\/j.spinee.2005.02.020","volume":"5","author":"IH Lieberman","year":"2005","unstructured":"Lieberman IH, Togawa D, Kayanja MM. Vertebroplasty and kyphoplasty: filler materials. Spine J. 2005;5:S305\u201316.","journal-title":"Spine J"},{"key":"4934_CR18","doi-asserted-by":"publisher","first-page":"960","DOI":"10.1002\/jbm.b.33424","volume":"104","author":"Y Liu","year":"2016","unstructured":"Liu Y, Xu J, Sun D, Luo F, Zhang Z, Dai F. Biomechanical and finite element analyses of bone cement-injectable cannulated pedicle screw fixation in osteoporotic bone. J Biomed Mater Res B Appl Biomater. 2016;104:960\u20137.","journal-title":"J Biomed Mater Res B Appl Biomater"},{"key":"4934_CR19","doi-asserted-by":"publisher","first-page":"114","DOI":"10.6061\/clinics\/2015(02)08","volume":"70","author":"F Dai","year":"2015","unstructured":"Dai F, Liu Y, Zhang F, Sun D, Luo F, Zhang Z, Xu J. Surgical treatment of the osteoporotic spine with bone cement-injectable cannulated pedicle screw fixation: technical description and preliminary application in 43 patients. Clin (Sao Paulo). 2015;70:114\u20139.","journal-title":"Clin (Sao Paulo)"},{"key":"4934_CR20","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1007\/s00586-004-0817-y","volume":"15","author":"JY Choi","year":"2006","unstructured":"Choi JY, Sung KH. Subsidence after anterior lumbar interbody fusion using paired stand-alone rectangular cages. Eur Spine J. 2006;15:16\u201322.","journal-title":"Eur Spine J"},{"key":"4934_CR21","doi-asserted-by":"publisher","first-page":"838","DOI":"10.1007\/s00586-014-3642-y","volume":"24","author":"CJ Siepe","year":"2015","unstructured":"Siepe CJ, Stosch-Wiechert K, Heider F, Amnajtrakul P, Krenauer A, Hitzl W, Szeimies U, St\u00e4bler A, Mayer HM. Anterior stand-alone fusion revisited: a prospective clinical, X-ray and CT investigation. Eur Spine J. 2015;24:838\u201351.","journal-title":"Eur Spine J"},{"key":"4934_CR22","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1302\/0301-620X.85B1.13026","volume":"85","author":"JS Yeom","year":"2003","unstructured":"Yeom JS, Kim WJ, Choy WS, Lee CK, Chang BS, Kang JW. Leakage of cement in percutaneous transpedicular vertebroplasty for painful osteoporotic compression fractures. J Bone Joint Surg Br. 2003;85:83\u20139.","journal-title":"J Bone Joint Surg Br"},{"key":"4934_CR23","doi-asserted-by":"publisher","first-page":"E784","DOI":"10.1097\/BSD.0000000000000406","volume":"30","author":"SJ Park","year":"2017","unstructured":"Park SJ, Lee CS, Chung SS, Kang SS, Park HJ, Kim SH. The Ideal cage position for achieving both indirect neural decompression and Segmental Angle Restoration in lateral lumbar Interbody Fusion (LLIF). Clin Spine Surg. 2017;30:E784\u2013784790.","journal-title":"Clin Spine Surg"},{"key":"4934_CR24","doi-asserted-by":"publisher","first-page":"20","DOI":"10.3109\/17453679408993711","volume":"65","author":"J St\u00fcrup","year":"1994","unstructured":"St\u00fcrup J, Nimb L, Kramh\u00f8ft M, Jensen JS. Effects of polymerization heat and monomers from acrylic cement on canine bone. Acta Orthop Scand. 1994;65:20\u20133.","journal-title":"Acta Orthop Scand"},{"key":"4934_CR25","doi-asserted-by":"publisher","first-page":"769","DOI":"10.1111\/j.1469-7580.2007.00816.x","volume":"211","author":"M van der Werf","year":"2007","unstructured":"van der Werf M, Lezuo P, Maissen O, van Donkelaar CC, Ito K. Inhibition of vertebral endplate perfusion results in decreased intervertebral disc intranuclear diffusive transport. J Anat. 2007;211:769\u201374.","journal-title":"J Anat"},{"key":"4934_CR26","doi-asserted-by":"publisher","first-page":"2171","DOI":"10.1097\/01.brs.0000180402.50500.5b","volume":"30","author":"L Chen","year":"2005","unstructured":"Chen L, Yang H, Tang T. Cage migration in spondylolisthesis treated with posterior lumbar interbody fusion using BAK cages. Spine (Phila Pa 1976). 2005;30:2171\u20135.","journal-title":"Spine (Phila Pa 1976)"},{"key":"4934_CR27","doi-asserted-by":"publisher","first-page":"110","DOI":"10.3171\/2013.4.SPINE12319","volume":"19","author":"L Marchi","year":"2013","unstructured":"Marchi L, Abdala N, Oliveira L, Amaral R, Coutinho E, Pimenta L. Radiographic and clinical evaluation of cage subsidence after stand-alone lateral interbody fusion. J Neurosurg Spine. 2013;19:110\u20138.","journal-title":"J Neurosurg Spine"},{"key":"4934_CR28","doi-asserted-by":"publisher","first-page":"525","DOI":"10.3171\/2018.3.SPINE171147","volume":"29","author":"N Agarwal","year":"2018","unstructured":"Agarwal N, Faramand A, Alan N, Tempel ZJ, Hamilton DK, Okonkwo DO, Kanter AS. Lateral lumbar interbody fusion in the elderly: a 10-year experience. J Neurosurg Spine. 2018;29:525\u20139.","journal-title":"J Neurosurg Spine"},{"key":"4934_CR29","doi-asserted-by":"publisher","first-page":"180","DOI":"10.1016\/j.jocn.2019.03.004","volume":"64","author":"JM Jung","year":"2019","unstructured":"Jung JM, Chung CK, Kim CH, Yang SH. Clinical and radiologic outcomes of single-level direct lateral lumbar interbody fusion in patients with osteopenia. J Clin Neurosci. 2019;64:180\u20136.","journal-title":"J Clin Neurosci"},{"key":"4934_CR30","doi-asserted-by":"publisher","first-page":"1131","DOI":"10.1007\/s00586-020-06348-0","volume":"29","author":"I Okano","year":"2020","unstructured":"Okano I, Jones C, Salzmann SN, Reisener MJ, Sax OC, Rentenberger C, Shue J, Carrino JA, Sama AA, Cammisa FP, Girardi FP, Hughes AP. Endplate volumetric bone mineral density measured by quantitative computed tomography as a novel predictive measure of severe cage subsidence after standalone lateral lumbar fusion. Eur Spine J. 2020;29:1131\u201340.","journal-title":"Eur Spine J"},{"key":"4934_CR31","doi-asserted-by":"publisher","first-page":"289","DOI":"10.14444\/6039","volume":"13","author":"RG Samtani","year":"2019","unstructured":"Samtani RG, Bernatz JT, Harrison R, Roy S, Gupta S, O\u2019Brien JR. The Effect of Alendronate on Subsidence after lateral transpsoas Interbody Fusion: a preliminary Report. Int J Spine Surg. 2019;13:289\u201395.","journal-title":"Int J Spine Surg"},{"key":"4934_CR32","doi-asserted-by":"publisher","first-page":"907","DOI":"10.4184\/asj.2016.10.5.907","volume":"10","author":"K Satake","year":"2016","unstructured":"Satake K, Kanemura T, Yamaguchi H, Segi N, Ouchida J. Predisposing factors for Intraoperative Endplate Injury of Extreme lateral Interbody Fusion. Asian Spine J. 2016;10:907\u201314.","journal-title":"Asian Spine J"},{"issue":"Suppl 3","key":"4934_CR33","doi-asserted-by":"publisher","first-page":"414","DOI":"10.1007\/s00586-015-3844-y","volume":"24","author":"ZJ Tempel","year":"2015","unstructured":"Tempel ZJ, Gandhoke GS, Okonkwo DO, Kanter AS. Impaired bone mineral density as a predictor of graft subsidence following minimally invasive transpsoas lateral lumbar interbody fusion. Eur Spine J. 2015;24(Suppl 3):414\u20139.","journal-title":"Eur Spine J"},{"key":"4934_CR34","doi-asserted-by":"publisher","first-page":"e969","DOI":"10.1016\/j.wneu.2018.10.182","volume":"122","author":"E Chen","year":"2019","unstructured":"Chen E, Xu J, Yang S, Zhang Q, Yi H, Liang D, Lan S, Duan M, Wu Z. Cage Subsidence and Fusion Rate in Extreme lateral Interbody Fusion with and without fixation. World Neurosurg. 2019;122:e969\u2013969977.","journal-title":"World Neurosurg"},{"key":"4934_CR35","doi-asserted-by":"publisher","first-page":"1280","DOI":"10.1097\/BRS.0000000000000400","volume":"39","author":"YS Lee","year":"2014","unstructured":"Lee YS, Kim YB, Park SW. Risk factors for postoperative subsidence of single-level anterior cervical discectomy and fusion: the significance of the preoperative cervical alignment. Spine (Phila Pa 1976). 2014;39:1280\u20137.","journal-title":"Spine (Phila Pa 1976)"},{"key":"4934_CR36","doi-asserted-by":"publisher","first-page":"350","DOI":"10.1097\/00007632-199402000-00017","volume":"19","author":"MH Krag","year":"1994","unstructured":"Krag MH, Johnson C. Repair of failed transpedicle screw fixation. A biomechanPfeifer BAical study comparing polymethylmethacrylate, milled bone, and matchstick bone reconstruction. Spine (Phila Pa 1976). 1994;19:350\u20133.","journal-title":"Spine (Phila Pa 1976)"},{"key":"4934_CR37","doi-asserted-by":"publisher","first-page":"2231","DOI":"10.1097\/00007632-199311000-00015","volume":"18","author":"SI Esses","year":"1993","unstructured":"Esses SI, Sachs BL, Dreyzin V. Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members. Spine (Phila Pa 1976). 1993;18:2231\u20138. discussion 2238-9.","journal-title":"Spine (Phila Pa 1976)"},{"key":"4934_CR38","doi-asserted-by":"publisher","first-page":"858","DOI":"10.1097\/00007632-200004010-00015","volume":"25","author":"K Okuyama","year":"2000","unstructured":"Okuyama K, Abe E, Suzuki T, Tamura Y, Chiba M, Sato K. Can insertional torque predict screw loosening and related failures? An in vivo study of pedicle screw fixation augmenting posterior lumbar interbody fusion. Spine (Phila Pa 1976). 2000;25:858\u201364.","journal-title":"Spine (Phila Pa 1976)"},{"key":"4934_CR39","doi-asserted-by":"publisher","first-page":"647","DOI":"10.1097\/00007632-199106000-00009","volume":"16","author":"RH Wittenberg","year":"1991","unstructured":"Wittenberg RH, Shea M, Swartz DE, Lee KS, White AA 3rd, Hayes WC. Importance of bone mineral density in instrumented spine fusions. Spine (Phila Pa 1976). 1991;16:647\u201352.","journal-title":"Spine (Phila Pa 1976)"},{"key":"4934_CR40","doi-asserted-by":"publisher","first-page":"531","DOI":"10.1227\/01.NEU.0000290899.15567.68","volume":"61","author":"BM Frankel","year":"2007","unstructured":"Frankel BM, Jones T, Wang C. Segmental polymethylmethacrylate-augmented pedicle screw fixation in patients with bone softening caused by osteoporosis and metastatic tumor involvement: a clinical evaluation. Neurosurgery. 2007;61:531\u20137. discussion 537-8.","journal-title":"Neurosurgery"},{"key":"4934_CR41","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1007\/s10195-011-0164-9","volume":"12","author":"L Amendola","year":"2011","unstructured":"Amendola L, Gasbarrini A, Fosco M, Simoes CE, Terzi S, De Iure F, Boriani S. Fenestrated pedicle screws for cement-augmented purchase in patients with bone softening: a review of 21 cases. J Orthop Traumatol. 2011;12:193\u20139.","journal-title":"J Orthop Traumatol"},{"key":"4934_CR42","doi-asserted-by":"crossref","unstructured":"Wittenberg RH, Lee KS, Shea M, White AA 3rd, Hayes WC. Effect of screw diameter, insertion technique, and bone cement augmentation of pedicular screw fixation strength. Clin Orthop Relat Res. 1993:278\u201387.","DOI":"10.1097\/00003086-199311000-00045"},{"key":"4934_CR43","doi-asserted-by":"publisher","first-page":"E1210","DOI":"10.1097\/BRS.0b013e318205e3af","volume":"36","author":"PE Par\u00e9","year":"2011","unstructured":"Par\u00e9 PE, Chappuis JL, Rampersaud R, Agarwala AO, Perra JH, Erkan S, Wu C. Biomechanical evaluation of a novel fenestrated pedicle screw augmented with bone cement in osteoporotic spines. Spine (Phila Pa 1976). 2011;36:E1210\u20134.","journal-title":"Spine (Phila Pa 1976)"},{"key":"4934_CR44","doi-asserted-by":"publisher","first-page":"1192","DOI":"10.1016\/j.spinee.2017.04.029","volume":"17","author":"M Mart\u00edn-Fern\u00e1ndez","year":"2017","unstructured":"Mart\u00edn-Fern\u00e1ndez M, L\u00f3pez-Herrad\u00f3n A, Pi\u00f1era AR, Tom\u00e9-Bermejo F, Duart JM, Vlad MD, Rodr\u00edguez-Arguisjuela MG, Alvarez-Galovich L. Potential risks of using cement-augmented screws for spinal fusion in patients with low bone quality. Spine J. 2017;17:1192\u20139.","journal-title":"Spine J"},{"key":"4934_CR45","doi-asserted-by":"publisher","first-page":"276","DOI":"10.1097\/BSD.0b013e3181f605d0","volume":"24","author":"W Cho","year":"2011","unstructured":"Cho W, Wu C, Zheng X, Erkan S, Suratwala SJ, Mehbod AA, Transfeldt EE. Is it safe to back out pedicle screws after augmentation with polymethyl methacrylate or calcium phosphate cement? A biomechanical study. J Spinal Disord Tech. 2011;24:276\u20139.","journal-title":"J Spinal Disord Tech"},{"key":"4934_CR46","doi-asserted-by":"publisher","first-page":"E932","DOI":"10.1097\/BRS.0b013e3181c6ec60","volume":"35","author":"V Bullmann","year":"2010","unstructured":"Bullmann V, Schmoelz W, Richter M, Grathwohl C, Schulte TL. Revision of cannulated and perforated cement-augmented pedicle screws: a biomechanical study in human cadavers. Spine (Phila Pa 1976). 2010;35:E932\u20139.","journal-title":"Spine (Phila Pa 1976)"},{"key":"4934_CR47","doi-asserted-by":"publisher","first-page":"23","DOI":"10.3171\/2009.3.SPINE08625","volume":"11","author":"TR Blattert","year":"2009","unstructured":"Blattert TR, Glasmacher S, Riesner HJ, Josten C. Revision characteristics of cement-augmented, cannulated-fenestrated pedicle screws in the osteoporotic vertebral body: a biomechanical in vitro investigation. Technical note. J Neurosurg Spine. 2009;11:23\u20137.","journal-title":"J Neurosurg Spine"},{"key":"4934_CR48","doi-asserted-by":"publisher","first-page":"2118","DOI":"10.1007\/s00586-007-0473-0","volume":"16","author":"A Boger","year":"2007","unstructured":"Boger A, Heini P, Windolf M, Schneider E. Adjacent vertebral failure after vertebroplasty: a biomechanical study of low-modulus PMMA cement. Eur Spine J. 2007;16:2118\u201325.","journal-title":"Eur Spine J"},{"key":"4934_CR49","doi-asserted-by":"publisher","first-page":"1061","DOI":"10.1097\/00007632-200005010-00004","volume":"25","author":"SM Belkoff","year":"2000","unstructured":"Belkoff SM, Mathis JM, Erbe EM, Fenton DC. Biomechanical evaluation of a new bone cement for use in vertebroplasty. Spine (Phila Pa 1976). 2000;25:1061\u20134.","journal-title":"Spine (Phila Pa 1976)"},{"key":"4934_CR50","doi-asserted-by":"publisher","first-page":"920","DOI":"10.1007\/s00586-011-2119-5","volume":"21","author":"M Kinzl","year":"2012","unstructured":"Kinzl M, Benneker LM, Boger A, Zysset PK, Pahr DH. The effect of standard and low-modulus cement augmentation on the stiffness, strength, and endplate pressure distribution in vertebroplasty. Eur Spine J. 2012;21:920\u20139.","journal-title":"Eur Spine J"},{"key":"4934_CR51","doi-asserted-by":"publisher","first-page":"2092","DOI":"10.1097\/01.brs.0000435029.88434.97","volume":"38","author":"R Aquarius","year":"2013","unstructured":"Aquarius R, van der Zijden AM, Homminga J, Verdonschot N, Tanck E. Does bone cement in percutaneous vertebroplasty act as a stress riser. Spine (Phila Pa 1976). 2013;38:2092\u20137.","journal-title":"Spine (Phila Pa 1976)"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-024-04934-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13018-024-04934-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-024-04934-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,7,27]],"date-time":"2024-07-27T16:06:17Z","timestamp":1722096377000},"score":1,"resource":{"primary":{"URL":"https:\/\/josr-online.biomedcentral.com\/articles\/10.1186\/s13018-024-04934-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,7,27]]},"references-count":51,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["4934"],"URL":"https:\/\/doi.org\/10.1186\/s13018-024-04934-2","relation":{},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,7,27]]},"assertion":[{"value":"1 June 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 July 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 July 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was approved by the Ethics Committee of Southwest Hospital (KY2024037) and conducted in accordance with the ethical guidelines of the Army Military Medical University. All patients participating in this study signed the informed consent form.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"440"}}