{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,14]],"date-time":"2026-02-14T02:19:50Z","timestamp":1771035590737,"version":"3.50.1"},"reference-count":56,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,8,27]],"date-time":"2024-08-27T00:00:00Z","timestamp":1724716800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,8,27]],"date-time":"2024-08-27T00:00:00Z","timestamp":1724716800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100003725","name":"National Research Foundation of Korea","doi-asserted-by":"publisher","award":["2019R1A2B5B01005924"],"award-info":[{"award-number":["2019R1A2B5B01005924"]}],"id":[{"id":"10.13039\/501100003725","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100014188","name":"Ministry of Science and ICT, South Korea","doi-asserted-by":"publisher","award":["50539-2022"],"award-info":[{"award-number":["50539-2022"]}],"id":[{"id":"10.13039\/501100014188","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Cerclage wiring is commonly used for treating fractures; however, it has several limitations, including mechanical weakness, decreased blood circulation, and technical complexity. In this study, we developed an implant using a shape memory alloy (SMA) and tested its efficacy in treating Vancouver type B1 (VB1) periprosthetic femoral fractures (PFFs) in a canine model.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>The mid-diaphyseal fracture models underwent reduction via the SMA plate (SMA group) or the cerclage cable plate (cable group) method in randomly selected pelvic limbs. An intraoperative evaluation was conducted to assess the surgical time and difficulty related to implant fitting. Clinical assessments, radiography, microcomputed tomography (micro-CT), histological analysis, positron emission tomography (PET)\/CT, and galvanic corrosion analysis were conducted for 52 weeks to evaluate bone healing and blood perfusion.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The results for bone healing and blood perfusion were not significantly different between the groups (<jats:italic>p<\/jats:italic>\u2009&gt;\u20090.05). In addition, no evidence of galvanic corrosion was present in any of the implants. However, the median surgical time was 75\u00a0min (range, 53\u201382\u00a0min) for the SMA group and 126\u00a0min (range, 120\u2013171\u00a0min) for the cable group, which was a statistically significant difference (<jats:italic>p<\/jats:italic>\u2009=\u20090.0286).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>This study assessed the ability of a newly developed shape memory alloy (SMA) to treat VB1 periprosthetic femoral fractures (PFFs) in canines for over a 52-week period and revealed outcomes comparable to those of traditional methods in terms of bone healing and mechanical stability. Despite the lower surgical complexity and potential time-saving benefits of this treatment, further research is needed to confirm its efficacy.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s13018-024-05011-4","type":"journal-article","created":{"date-parts":[[2024,8,27]],"date-time":"2024-08-27T04:02:24Z","timestamp":1724731344000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Pilot study on the feasibility of shape memory alloy implantation for Vancouver type B1 periprosthetic femoral fractures in a canine model: a step toward advancing treatment modalities"],"prefix":"10.1186","volume":"19","author":[{"given":"Hyunsoo","family":"Kim","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kyu-Won","family":"Kang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Timofey","family":"Chekalkin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jang-Woo","family":"Park","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hye-Kyung","family":"Chung","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Byung-Jae","family":"Kang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sung-Woo","family":"Choi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2024,8,27]]},"reference":[{"issue":"3","key":"5011_CR1","doi-asserted-by":"publisher","first-page":"419","DOI":"10.1111\/vec.12434","volume":"26","author":"JW Swann","year":"2016","unstructured":"Swann JW, Maunder CL, Roberts E, McLauchlan G, Adamantos S. Prevalence and risk factors for development of hemorrhagic gastro-intestinal disease in veterinary intensive care units in the United Kingdom. J Vet Emerg Crit Care (San Antonio). 2016;26(3):419\u201327.","journal-title":"J Vet Emerg Crit Care (San Antonio)"},{"issue":"1","key":"5011_CR2","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1016\/j.arth.2006.02.077","volume":"22","author":"JB Stiehl","year":"2007","unstructured":"Stiehl JB, Mahfouz MR. Catastrophic failure of a modular revision total hip polyethylene insert. J Arthroplast. 2007;22(1):143\u20137.","journal-title":"J Arthroplast"},{"issue":"1","key":"5011_CR3","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1080\/17453670710014707","volume":"79","author":"LO Lam","year":"2008","unstructured":"Lam LO, Stoffel K, Kop A, Swarts E. Catastrophic failure of 4 cobalt-alloy omnifit hip arthroplasty femoral components. Acta Orthop. 2008;79(1):18\u201321.","journal-title":"Acta Orthop"},{"issue":"4","key":"5011_CR4","doi-asserted-by":"publisher","first-page":"485","DOI":"10.1007\/s00264-009-0815-0","volume":"34","author":"C Mukundan","year":"2010","unstructured":"Mukundan C, Rayan F, Kheir E, Macdonald D. Management of late periprosthetic femur fractures: a retrospective cohort of 72 patients. Int Orthop. 2010;34(4):485\u20139.","journal-title":"Int Orthop"},{"key":"5011_CR5","doi-asserted-by":"publisher","first-page":"80","DOI":"10.1097\/00003086-200403000-00012","volume":"420","author":"BA Masri","year":"2004","unstructured":"Masri BA, Meek RMD, Duncan CP. Periprosthetic fractures evaluation and treatment. Clin Orthop Relat Research\u00ae. 2004;420:80\u201395.","journal-title":"Clin Orthop Relat Research\u00ae"},{"key":"5011_CR6","first-page":"293","volume":"44","author":"C Duncan","year":"1995","unstructured":"Duncan C. Fractures of the femur after hip replacement. Instr Course Lect. 1995;44:293\u2013304.","journal-title":"Instr Course Lect"},{"issue":"7","key":"5011_CR7","doi-asserted-by":"publisher","first-page":"857","DOI":"10.1016\/j.arth.2005.02.001","volume":"20","author":"H Lindahl","year":"2005","unstructured":"Lindahl H, Malchau H, Herberts P, Garellick G. Periprosthetic femoral fractures: classification and demographics of 1049 periprosthetic femoral fractures from the Swedish National Hip Arthroplasty Register. J Arthroplast. 2005;20(7):857\u201365.","journal-title":"J Arthroplast"},{"issue":"1","key":"5011_CR8","doi-asserted-by":"publisher","first-page":"126","DOI":"10.1177\/11207000211017115","volume":"33","author":"M Thaler","year":"2023","unstructured":"Thaler M, Weiss C, Lechner R, Epinette JA, Karachalios TS, Zagra L. Treatment of periprosthetic femoral fractures following total hip arthroplasty: results of an online survey of the European Hip Society. Hip Int. 2023;33(1):126\u201332.","journal-title":"Hip Int"},{"issue":"3","key":"5011_CR9","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1177\/2151458512462870","volume":"3","author":"D Marsland","year":"2012","unstructured":"Marsland D, Mears SC. A review of periprosthetic femoral fractures associated with total hip arthroplasty. Geriatric Orthop Surg Rehabilitation. 2012;3(3):107\u201320.","journal-title":"Geriatric Orthop Surg Rehabilitation"},{"issue":"12","key":"5011_CR10","doi-asserted-by":"publisher","first-page":"721","DOI":"10.1097\/BOT.0000000000000126","volume":"28","author":"N Dehghan","year":"2014","unstructured":"Dehghan N, McKee MD, Nauth A, Ristevski B, Schemitsch EH. Surgical fixation of Vancouver type B1 periprosthetic femur fractures: a systematic review. J Orthop Trauma. 2014;28(12):721\u20137.","journal-title":"J Orthop Trauma"},{"issue":"2","key":"5011_CR11","doi-asserted-by":"publisher","first-page":"79","DOI":"10.5763\/kjsm.2014.32.2.79","volume":"32","author":"YS Lee","year":"2014","unstructured":"Lee YS, Lee JY, Park SS, Lim CW, Kwon EJ. A comparison of Bicortical and Intramedullary Screw fixations in Jones\u2019 fractures using finite element analysis-preliminary Report. Korean J Sports Med. 2014;32(2):79\u201384.","journal-title":"Korean J Sports Med"},{"issue":"11","key":"5011_CR12","doi-asserted-by":"publisher","first-page":"1447","DOI":"10.1302\/0301-620X.101B11.BJJ-2019-0480.R2","volume":"101","author":"G Chatziagorou","year":"2019","unstructured":"Chatziagorou G, Lindahl H, K\u00e4rrholm J. Surgical treatment of Vancouver type B periprosthetic femoral fractures: patient characteristics and outcomes of 1381 fractures treated in Sweden between 2001 and 2011. Bone Joint J. 2019;101(11):1447\u201358.","journal-title":"Bone Joint J"},{"issue":"10","key":"5011_CR13","doi-asserted-by":"publisher","first-page":"e364","DOI":"10.1097\/BOT.0000000000000365","volume":"29","author":"GS Lewis","year":"2015","unstructured":"Lewis GS, Caroom CT, Wee H, Jurgensmeier D, Rothermel SD, Bramer MA, et al. Tangential bicortical locked fixation improves stability in Vancouver B1 periprosthetic femur fractures: a biomechanical study. J Orthop Trauma. 2015;29(10):e364.","journal-title":"J Orthop Trauma"},{"issue":"3","key":"5011_CR14","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1111\/os.12052","volume":"5","author":"NA Ebraheim","year":"2013","unstructured":"Ebraheim NA, Sochacki KR, Liu X, Hirschfeld AG, Liu J. Locking plate fixation of periprosthetic femur fractures with and without cerclage wires. Orthop Surg. 2013;5(3):183\u20137.","journal-title":"Orthop Surg"},{"issue":"3","key":"5011_CR15","doi-asserted-by":"publisher","first-page":"521","DOI":"10.1097\/00005373-199709000-00023","volume":"43","author":"M Van Steijn","year":"1997","unstructured":"Van Steijn M, Verhaar J. Osteonecrosis caused by percutaneous cerclage wiring of a tibial fracture: case report. J Trauma Acute Care Surg. 1997;43(3):521\u20132.","journal-title":"J Trauma Acute Care Surg"},{"key":"5011_CR16","doi-asserted-by":"publisher","first-page":"164","DOI":"10.1097\/00003086-199106000-00025","volume":"267","author":"H Habernek","year":"1991","unstructured":"Habernek H. Percutaneous cerclage wiring and interlocking nailing for treatment of torsional fractures of the tibia. Clin Orthop Relat Res. 1991;267:164\u20138.","journal-title":"Clin Orthop Relat Res"},{"issue":"5","key":"5011_CR17","doi-asserted-by":"publisher","first-page":"454","DOI":"10.4103\/0019-5413.118200","volume":"47","author":"BF El-Zayat","year":"2013","unstructured":"El-Zayat BF, Ruchholtz S, Efe T, Paletta J, Kreslo D, Zettl R. Results of titanium locking plate and stainless steel cerclage wire combination in femoral fractures. Indian J Orthop. 2013;47(5):454\u20138.","journal-title":"Indian J Orthop"},{"key":"5011_CR18","doi-asserted-by":"publisher","first-page":"105709","DOI":"10.1016\/j.clinbiomech.2022.105709","volume":"97","author":"R Gupta","year":"2022","unstructured":"Gupta R, Schmidt EC, Namdari S, Stone MA, Hast MW. The addition of cerclage wiring does not improve proximal bicortical fixation of locking plates for type C periprosthetic fractures in synthetic humeri. Clin Biomech Elsevier Ltd. 2022;97:105709.","journal-title":"Clin Biomech Elsevier Ltd"},{"key":"5011_CR19","unstructured":"Yahia L. Shape memory implants. Springer Science & Business Media; 2012."},{"issue":"1","key":"5011_CR20","first-page":"69","volume":"12","author":"SA Shabalovskaya","year":"2002","unstructured":"Shabalovskaya SA. Surface, corrosion and biocompatibility aspects of Nitinol as an implant material. Biomed Mater Eng. 2002;12(1):69\u2013109.","journal-title":"Biomed Mater Eng"},{"key":"5011_CR21","doi-asserted-by":"crossref","unstructured":"Oh SH, Suh YS, Eghan-Acquah E, Yurevich KM, Won SH, Baek MJ et al. Unstable Vancouver B1 periprosthetic femoral fracture fixation: a Biomechanical comparison between Cerclage Wiring and C-Shaped shape memory Alloy Implant. 2020.","DOI":"10.21203\/rs.3.rs-113117\/v1"},{"issue":"5","key":"5011_CR22","doi-asserted-by":"publisher","first-page":"1475","DOI":"10.1063\/1.1729603","volume":"34","author":"WJ Buehler","year":"1963","unstructured":"Buehler WJ, Gilfrich JV, Wiley R. Effect of low-temperature phase changes on the mechanical properties of alloys near composition TiNi. J Appl Phys. 1963;34(5):1475\u20137.","journal-title":"J Appl Phys"},{"key":"5011_CR23","doi-asserted-by":"crossref","unstructured":"Edamura K, King JN, Seewald W, Sakakibara N, Okumura M. Comparison of oral robenacoxib and carprofen for the treatment of osteoarthritis in dogs: a randomized clinical trial. J Vet Med Sci, 2012;11\u20130529.","DOI":"10.1292\/jvms.11-0529"},{"issue":"6","key":"5011_CR24","doi-asserted-by":"publisher","first-page":"1357","DOI":"10.1016\/j.bone.2012.03.008","volume":"50","author":"KR O\u2019Neill","year":"2012","unstructured":"O\u2019Neill KR, Stutz CM, Mignemi NA, Burns MC, Murry MR, Nyman JS, et al. Micro-computed tomography assessment of the progression of fracture healing in mice. Bone. 2012;50(6):1357\u201367.","journal-title":"Bone"},{"issue":"1","key":"5011_CR25","doi-asserted-by":"publisher","first-page":"136","DOI":"10.1016\/j.bone.2005.07.028","volume":"38","author":"CM Bagi","year":"2006","unstructured":"Bagi CM, Hanson N, Andresen C, Pero R, Lariviere R, Turner CH, et al. The use of micro-CT to evaluate cortical bone geometry and strength in nude rats: correlation with mechanical testing, pQCT and DXA. Bone. 2006;38(1):136\u201344.","journal-title":"Bone"},{"issue":"2","key":"5011_CR26","doi-asserted-by":"publisher","first-page":"335","DOI":"10.1016\/j.bone.2008.10.039","volume":"44","author":"EF Morgan","year":"2009","unstructured":"Morgan EF, Mason ZD, Chien KB, Pfeiffer AJ, Barnes GL, Einhorn TA, et al. Micro-computed tomography assessment of fracture healing: relationships among callus structure, composition, and mechanical function. Bone. 2009;44(2):335\u201344.","journal-title":"Bone"},{"issue":"2","key":"5011_CR27","doi-asserted-by":"publisher","first-page":"153","DOI":"10.5624\/isd.2020.50.2.153","volume":"50","author":"H Ga\u00eata-Araujo","year":"2020","unstructured":"Ga\u00eata-Araujo H, Nascimento EHL, Brasil DM, Madlum DV, Haiter-Neto F, Oliveira-Santos C. Influence of reconstruction parameters of micro-computed tomography on the analysis of bone mineral density. Imaging Sci Dentistry. 2020;50(2):153.","journal-title":"Imaging Sci Dentistry"},{"issue":"12","key":"5011_CR28","first-page":"1970","volume":"38","author":"C Schiepers","year":"1997","unstructured":"Schiepers C, Nuyts J, Bormans G, Dequeker J, Bouillon R, Mortelmans L, et al. Fluoride kinetics of the axial skeleton measured in vivo with fluorine-18-fluoride PET. J Nucl Med. 1997;38(12):1970\u20136.","journal-title":"J Nucl Med"},{"issue":"4","key":"5011_CR29","doi-asserted-by":"publisher","first-page":"517","DOI":"10.2967\/jnumed.107.048504","volume":"49","author":"NA Mullani","year":"2008","unstructured":"Mullani NA, Herbst RS, O\u2019Neil RG, Gould KL, Barron BJ, Abbruzzese JL. Tumor blood flow measured by PET dynamic imaging of first-pass 18F-FDG uptake: a comparison with 15O-labeled water-measured blood flow. J Nucl Med. 2008;49(4):517\u201323.","journal-title":"J Nucl Med"},{"key":"5011_CR30","doi-asserted-by":"publisher","DOI":"10.1520\/STP26188S","volume-title":"Electrochemical theory of galvanic corrosion","author":"JW Oldfield","year":"1988","unstructured":"Oldfield JW. Electrochemical theory of galvanic corrosion. PA: ASTM International West Conshohocken; 1988."},{"issue":"3","key":"5011_CR31","doi-asserted-by":"publisher","first-page":"619","DOI":"10.1007\/s00264-011-1325-4","volume":"36","author":"X Zhao","year":"2012","unstructured":"Zhao X, Zhu ZA, Sun YH, Wang Y, Zhao J, Zhang YJ, et al. Nickel-titanium shape-memory sawtooth-arm embracing fixator for periprosthetic femoral fractures. Int Orthop. 2012;36(3):619\u201326.","journal-title":"Int Orthop"},{"key":"5011_CR32","unstructured":"Handbook VVD. Principles and Application of Cerclage Wire Full and Hemicerclage Wiring World Small Animal Veterinary Association World Congress Proceedings, 2003."},{"issue":"1","key":"5011_CR33","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/1746-6148-9-125","volume":"9","author":"P Chao","year":"2013","unstructured":"Chao P, Conrad BP, Lewis DD, Horodyski M, Pozzi A. Effect of plate working length on plate stiffness and cyclic fatigue life in a cadaveric femoral fracture gap model stabilized with a 12-hole 2.4\u00a0mm locking compression plate. BMC Vet Res. 2013;9(1):1\u20137.","journal-title":"BMC Vet Res"},{"key":"5011_CR34","doi-asserted-by":"crossref","unstructured":"Halvachizadeh S, Pape HC. Perren\u2019s strain theory and fracture healing. Essent Biomech Orthop Trauma. 2020;17\u201325.","DOI":"10.1007\/978-3-030-36990-3_2"},{"key":"5011_CR35","doi-asserted-by":"crossref","unstructured":"Timon C, Keady C. Thermal osteonecrosis caused by bone drilling in orthopedic surgery: a literature review. Cureus, 2019;11(7).","DOI":"10.7759\/cureus.5226"},{"key":"5011_CR36","doi-asserted-by":"crossref","unstructured":"Morshed S. Current options for determining fracture union. Advances in medicine, 2014; 2014.","DOI":"10.1155\/2014\/708574"},{"issue":"1","key":"5011_CR37","doi-asserted-by":"publisher","first-page":"e1","DOI":"10.1111\/clr.12315","volume":"26","author":"A Parsa","year":"2015","unstructured":"Parsa A, Ibrahim N, Hassan B, van der Stelt P, Wismeijer D. Bone quality evaluation at dental implant site using multislice CT, micro-CT, and cone beam CT. Clin Oral Implants Res. 2015;26(1):e1\u20137.","journal-title":"Clin Oral Implants Res"},{"issue":"6","key":"5011_CR38","doi-asserted-by":"publisher","first-page":"794","DOI":"10.1016\/j.dental.2016.03.025","volume":"32","author":"M Gramanzini","year":"2016","unstructured":"Gramanzini M, Gargiulo S, Zarone F, Megna R, Apicella A, Aversa R, et al. Combined microcomputed tomography, biomechanical and histomorphometric analysis of the peri-implant bone: a pilot study in minipig model. Dent Mater. 2016;32(6):794\u2013806.","journal-title":"Dent Mater"},{"issue":"9","key":"5011_CR39","doi-asserted-by":"publisher","first-page":"e0237678","DOI":"10.1371\/journal.pone.0237678","volume":"15","author":"K Mie","year":"2020","unstructured":"Mie K, Ishimoto T, Okamoto M, Iimori Y, Ashida K, Yoshizaki K, et al. Impaired bone quality characterized by apatite orientation under stress shielding following fixing of a fracture of the radius with a 3D printed Ti-6Al-4V custom-made bone plate in dogs. PLoS ONE. 2020;15(9):e0237678.","journal-title":"PLoS ONE"},{"issue":"4","key":"5011_CR40","doi-asserted-by":"publisher","first-page":"561","DOI":"10.1002\/jor.21537","volume":"30","author":"AD Mercurio","year":"2012","unstructured":"Mercurio AD, Motta T, Green E, Noble G, Hart RT, Allen MJ. Effects of extensive circumferential periosteal stripping on the microstructure and mechanical properties of the murine femoral cortex. J Orthop Res. 2012;30(4):561\u20138.","journal-title":"J Orthop Res"},{"key":"5011_CR41","volume-title":"AO principles of fracture management","author":"TP R\u00fcedi","year":"2000","unstructured":"R\u00fcedi TP, Murphy WM, Colton CL, Fackelman GE, Harder Y. AO principles of fracture management. Stuttgart: Thieme; 2000."},{"issue":"1","key":"5011_CR42","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1007\/s002239900080","volume":"59","author":"M Kowalski","year":"1996","unstructured":"Kowalski M, Schemitsch E, Kregor P, Senft D, Swiontkowski M. Effect of periosteal stripping on cortical bone perfusion: a laser doppler study in sheep. Calcif Tissue Int. 1996;59(1):24\u20136.","journal-title":"Calcif Tissue Int"},{"key":"5011_CR43","doi-asserted-by":"publisher","first-page":"311","DOI":"10.4248\/BR201304002","volume":"1","author":"RE Tomlinson","year":"2013","unstructured":"Tomlinson RE, Silva MJ. Skeletal blood flow in bone repair and maintenance. Bone Res. 2013;1:311\u201322.","journal-title":"Bone Res"},{"issue":"4","key":"5011_CR44","doi-asserted-by":"publisher","first-page":"523","DOI":"10.1054\/arth.2000.4339","volume":"15","author":"MG Dennis","year":"2000","unstructured":"Dennis MG, Simon JA, Kummer FJ, Koval KJ, DiCesare PE. Fixation of periprosthetic femoral shaft fractures occurring at the tip of the stem: a biomechanical study of 5 techniques. J Arthroplast. 2000;15(4):523\u20138.","journal-title":"J Arthroplast"},{"issue":"5","key":"5011_CR45","doi-asserted-by":"publisher","first-page":"673","DOI":"10.1302\/0301-620X.74B5.1527111","volume":"74","author":"GP Ashcroft","year":"1992","unstructured":"Ashcroft GP, Evans NT, Roeda D, Dodd M, Mallard JR, Porter RW, et al. Measurement of blood flow in tibial fracture patients using positron emission tomography. J Bone Joint Surg Br. 1992;74(5):673\u20137.","journal-title":"J Bone Joint Surg Br"},{"issue":"5","key":"5011_CR46","doi-asserted-by":"publisher","first-page":"381","DOI":"10.1097\/00005131-199505000-00004","volume":"9","author":"SS Stevens","year":"1995","unstructured":"Stevens SS, Irish AJ, Vachtsevanos JG, Csongradi J, Beaupr\u00e9 GS. A biomechanical study of three wiring techniques for cerclage-plating. J Orthop Trauma. 1995;9(5):381\u20137.","journal-title":"J Orthop Trauma"},{"issue":"4","key":"5011_CR47","doi-asserted-by":"publisher","first-page":"1119","DOI":"10.1007\/s00264-008-0603-2","volume":"33","author":"T Apivatthakakul","year":"2009","unstructured":"Apivatthakakul T, Chiewcharntanakit S. Minimally invasive plate osteosynthesis (MIPO) in the treatment of the femoral shaft fracture where intramedullary nailing is not indicated. Int Orthop. 2009;33(4):1119\u201326.","journal-title":"Int Orthop"},{"issue":"6","key":"5011_CR48","doi-asserted-by":"publisher","first-page":"401","DOI":"10.1097\/00005131-199908000-00002","volume":"13","author":"O Farouk","year":"1999","unstructured":"Farouk O, Krettek C, Miclau T, Schandelmaier P, Guy P, Tscherne H. Minimally invasive plate osteosynthesis: does percutaneous plating disrupt femoral blood supply less than the traditional technique? J Orthop Trauma. 1999;13(6):401\u20136.","journal-title":"J Orthop Trauma"},{"issue":"1\u20132","key":"5011_CR49","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1016\/S0928-4931(01)00331-9","volume":"17","author":"K Hattori","year":"2001","unstructured":"Hattori K, Tomita N, Yoshikawa T, Takakura Y. Prospects for bone fixation\u2014development of new cerclage fixation techniques. Mater Sci Engineering: C. 2001;17(1\u20132):27\u201332.","journal-title":"Mater Sci Engineering: C"},{"issue":"4","key":"5011_CR50","first-page":"336","volume":"61","author":"GL Colborn","year":"1995","unstructured":"Colborn GL, Mattar SG, Taylor B, Skandalakis JE, Lumsden AB. The surgical anatomy of the deep femoral artery. Am Surg. 1995;61(4):336\u201346.","journal-title":"Am Surg"},{"issue":"5","key":"5011_CR51","doi-asserted-by":"publisher","first-page":"695","DOI":"10.1002\/jbm.820100505","volume":"10","author":"L Castleman","year":"1976","unstructured":"Castleman L, Motzkin S, Alicandri F, Bonawit V, Johnson A. Biocompatibility of nitinol alloy as an implant material. J Biomed Mater Res. 1976;10(5):695\u2013731.","journal-title":"J Biomed Mater Res"},{"key":"5011_CR52","unstructured":"Kato Y, Ito A, Hattori T, Akahori T, Kimata N. Animal experiment on in vivo galvanic corrosion of SUS 316L and Ti-6Al-4V. Journal of Material Science & Engineering; 2015."},{"key":"5011_CR53","unstructured":"Joseph A. Corrosion of orthodontic devices. In seminars in orthodontics. Elsevier; 1997."},{"issue":"1","key":"5011_CR54","doi-asserted-by":"publisher","first-page":"171","DOI":"10.3390\/ma11010171","volume":"11","author":"A Mellado-Valero","year":"2018","unstructured":"Mellado-Valero A, Igual Mu\u00f1oz A, Gui\u00f1\u00f3n Pina V, Sola-Ruiz MF. Electrochemical behaviour and galvanic effects of titanium implants coupled to metallic suprastructures in artificial saliva. Materials. 2018;11(1):171.","journal-title":"Materials"},{"issue":"3","key":"5011_CR55","doi-asserted-by":"publisher","first-page":"287","DOI":"10.1016\/j.jpurol.2017.12.012","volume":"14","author":"L Harper","year":"2018","unstructured":"Harper L, Herbst KW, Kalfa N. Ethical issues in research: human and animal experimentation. J Pediatr Urol. 2018;14(3):287\u20138.","journal-title":"J Pediatr Urol"},{"issue":"1","key":"5011_CR56","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s13018-021-02492-5","volume":"16","author":"F Ozan","year":"2021","unstructured":"Ozan F, Kahraman M, Bakt\u0131r A, Gen\u00e7er K. Catastrophic failure and metallosis of the acetabular component in total hip arthroplasty. J Orthop Surg Res. 2021;16(1):1\u20137.","journal-title":"J Orthop Surg Res"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-024-05011-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13018-024-05011-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-024-05011-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,27]],"date-time":"2024-08-27T16:04:38Z","timestamp":1724774678000},"score":1,"resource":{"primary":{"URL":"https:\/\/josr-online.biomedcentral.com\/articles\/10.1186\/s13018-024-05011-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8,27]]},"references-count":56,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["5011"],"URL":"https:\/\/doi.org\/10.1186\/s13018-024-05011-4","relation":{},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,8,27]]},"assertion":[{"value":"22 February 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 August 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 August 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was approved by the Institutional Animal Care and Use Committee (SNU-200709-4-1) and was performed in accordance with ARRIVE guidelines 2.0 and relevant regulations.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"510"}}