{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,7]],"date-time":"2026-09-07T23:22:46Z","timestamp":1788823366478,"version":"build-2803163510"},"reference-count":64,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,9,14]],"date-time":"2024-09-14T00:00:00Z","timestamp":1726272000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,9,14]],"date-time":"2024-09-14T00:00:00Z","timestamp":1726272000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100005713","name":"Technische Universit\u00e4t M\u00fcnchen","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100005713","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Background<\/jats:title><jats:p>In modern Hybrid ORs, the synergies of navigation and robotics are assumed to contribute to the optimisation of the treatment in trauma, orthopaedic and spine surgery. Despite promising evidence in the area of navigation and robotics, previous publications have not definitively proven the potential benefits. Therefore, the aim of this retrospective study was to evaluate the potential benefit and clinical outcome of patients treated in a fully equipped 3D-Navigation Hybrid OR.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Prospective data was collected (March 2022- March 2024) after implementation of a fully equipped 3D-Navigation Hybrid OR (\u201cRobotic Suite\u201d) in the authors level 1 trauma centre. The OR includes a navigation unit, a cone beam CT (CBCT), a robotic arm and mixed reality glasses. Surgeries with different indications of the spine, the pelvis (pelvic ring and acetabulum) and the extremities were performed. Spinal and non-spinal screws were inserted. The collected data was analysed retrospectively. Pedicle screw accuracy was graded according to the Gertzbein and Robbins (GR) classification.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>A total of<jats:italic>n<\/jats:italic>\u2009=\u2009210 patients (118\u00a0m:92f) were treated in our 3D-Navigation Hybrid OR, with 1171 screws inserted. Among these patients, 23 patients (11.0%) arrived at the hospital via the trauma room with an average Injury Severity Score (ISS) of 25.7. There were 1035 (88.4%) spinal screws inserted at an accuracy rate of 98.7% (CI95%: 98.1-99.4%; 911 GR-A &amp; 111 GR-B screws). The number of non-spinal screws were 136 (11.6%) with an accuracy rate of 99.3% (CI95%: 97.8-100.0%; 135 correctly placed screws). This resulted in an overall accuracy rate of 98.8% (CI95%: 98.2-99.4%). The robotic arm was used in 152 cases (72.4%), minimally invasive surgery (MIS) was performed in 139 cases (66.2%) and wound infection occurred in 4 cases (1,9%). Overall, no revisions were needed.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>By extending the scope of application, this study showed that interventions in a fully equipped 3D-Navigation Hybrid OR can be successfully performed not only on the spine, but also on the pelvis and extremities. In trauma, orthopaedics and spinal surgery, navigation and robotics can be used to perform operations with a high degree of precision, increased safety, reduced radiation exposure for the OR-team and a very low complication rate.<\/jats:p><\/jats:sec>","DOI":"10.1186\/s13018-024-05044-9","type":"journal-article","created":{"date-parts":[[2024,9,14]],"date-time":"2024-09-14T02:01:57Z","timestamp":1726279317000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":15,"title":["Hybrid-3D robotic suite in spine and trauma surgery - experiences in 210 patients"],"prefix":"10.1186","volume":"19","author":[{"given":"Dominik M.","family":"Haida","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Mohr","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sae-Yeon","family":"Won","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thorsten","family":"M\u00f6hlig","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mike","family":"Holl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thorsten","family":"Enk","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marc","family":"Hanschen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefan","family":"Huber-Wagner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,9,14]]},"reference":[{"issue":"12","key":"5044_CR1","doi-asserted-by":"publisher","first-page":"1020","DOI":"10.1007\/s00104-013-2553-5","volume":"84","author":"U Settmacher","year":"2013","unstructured":"Settmacher U. [Hybrid operation theatre]. Chirurg. 2013;84(12):1020\u20131.","journal-title":"Chirurg"},{"key":"5044_CR2","doi-asserted-by":"crossref","unstructured":"Richter PH, Gebhard F. [The interdisciplinary hybrid operation theatre. Current experience and future]. Chirurg, 2013. 84(12): pp. 1036-40.","DOI":"10.1007\/s00104-013-2558-0"},{"issue":"13","key":"5044_CR3","doi-asserted-by":"publisher","first-page":"1381","DOI":"10.1097\/00007632-199907010-00018","volume":"24","author":"SG Marketos","year":"1999","unstructured":"Marketos SG, Skiadas P. Hippocrates. The father of spine surgery. Spine (Phila Pa 1976). 1999;24(13):1381\u20137.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"1","key":"5044_CR4","doi-asserted-by":"publisher","first-page":"134","DOI":"10.1016\/j.jor.2016.10.029","volume":"14","author":"SP Tarpada","year":"2017","unstructured":"Tarpada SP, Morris MT, Burton DA. Spinal fusion surgery: a historical perspective. J Orthop. 2017;14(1):134\u20136.","journal-title":"J Orthop"},{"issue":"4","key":"5044_CR5","first-page":"375","volume":"26","author":"JW Markham","year":"1952","unstructured":"Markham JW. The history of laminectomy prior to 1866. Bull Hist Med. 1952;26(4):375\u201384.","journal-title":"Bull Hist Med"},{"issue":"6","key":"5044_CR6","doi-asserted-by":"publisher","first-page":"775","DOI":"10.3171\/2019.9.SPINE181362","volume":"31","author":"CT Walker","year":"2019","unstructured":"Walker CT, et al. History and advances in spinal neurosurgery. J Neurosurg Spine. 2019;31(6):775\u201385.","journal-title":"J Neurosurg Spine"},{"issue":"3","key":"5044_CR7","doi-asserted-by":"publisher","first-page":"E11","DOI":"10.3171\/2009.6.FOCUS09109","volume":"27","author":"Y Enchev","year":"2009","unstructured":"Enchev Y. Neuronavigation: geneology, reality, and prospects. Neurosurg Focus. 2009;27(3):E11.","journal-title":"Neurosurg Focus"},{"key":"5044_CR8","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1016\/j.wneu.2020.08.224","volume":"145","author":"JZ Mao","year":"2021","unstructured":"Mao JZ, et al. Technologic Evolution of Navigation and Robotics in spine surgery: a historical perspective. World Neurosurg. 2021;145:159\u201367.","journal-title":"World Neurosurg"},{"issue":"12","key":"5044_CR9","doi-asserted-by":"publisher","first-page":"1799","DOI":"10.1016\/j.spinee.2023.08.010","volume":"23","author":"J Haemmerli","year":"2023","unstructured":"Haemmerli J, et al. Comparison of intraoperative CT- and cone beam CT-based spinal navigation for the treatment of atlantoaxial instability. Spine J. 2023;23(12):1799\u2013807.","journal-title":"Spine J"},{"key":"5044_CR10","doi-asserted-by":"publisher","first-page":"e20202798","DOI":"10.1590\/0100-6991e-20202798","volume":"48","author":"ALG Morrell","year":"2021","unstructured":"Morrell ALG, et al. The history of robotic surgery and its evolution: when illusion becomes reality. Rev Col Bras Cir. 2021;48:e20202798.","journal-title":"Rev Col Bras Cir"},{"issue":"Suppl 1","key":"5044_CR11","doi-asserted-by":"publisher","first-page":"S31","DOI":"10.21037\/jss.2019.04.16","volume":"5","author":"BN Staub","year":"2019","unstructured":"Staub BN, Sadrameli SS. The use of robotics in minimally invasive spine surgery. J Spine Surg. 2019;5(Suppl 1):S31\u201340.","journal-title":"J Spine Surg"},{"issue":"1","key":"5044_CR12","doi-asserted-by":"publisher","first-page":"60","DOI":"10.3340\/jkns.2023.0128","volume":"67","author":"BK Oh","year":"2024","unstructured":"Oh BK, et al. A single-center experience of robotic-assisted spine surgery in Korea: analysis of Screw Accuracy, potential risk factor of Screw Malposition and learning curve. J Korean Neurosurg Soc. 2024;67(1):60\u201372.","journal-title":"J Korean Neurosurg Soc"},{"issue":"6","key":"5044_CR13","doi-asserted-by":"publisher","first-page":"860","DOI":"10.1007\/s00586-011-1729-2","volume":"20","author":"SR Kantelhardt","year":"2011","unstructured":"Kantelhardt SR, et al. Perioperative course and accuracy of screw positioning in conventional, open robotic-guided and percutaneous robotic-guided, pedicle screw placement. Eur Spine J. 2011;20(6):860\u20138.","journal-title":"Eur Spine J"},{"issue":"2","key":"5044_CR14","doi-asserted-by":"publisher","first-page":"113","DOI":"10.3171\/2012.5.SPINE11399","volume":"17","author":"BJ Shin","year":"2012","unstructured":"Shin BJ, et al. Pedicle screw navigation: a systematic review and meta-analysis of perforation risk for computer-navigated versus freehand insertion. J Neurosurg Spine. 2012;17(2):113\u201322.","journal-title":"J Neurosurg Spine"},{"issue":"5","key":"5044_CR15","doi-asserted-by":"publisher","first-page":"E298","DOI":"10.1097\/BSD.0b013e31828af33e","volume":"28","author":"N Luther","year":"2015","unstructured":"Luther N, et al. Comparison of navigated versus non-navigated pedicle screw placement in 260 patients and 1434 screws: screw accuracy, screw size, and the complexity of surgery. J Spinal Disord Tech. 2015;28(5):E298\u2013303.","journal-title":"J Spinal Disord Tech"},{"issue":"12","key":"5044_CR16","doi-asserted-by":"publisher","first-page":"2967","DOI":"10.1007\/s00586-015-3974-2","volume":"24","author":"J Bredow","year":"2015","unstructured":"Bredow J, et al. The accuracy of 3D fluoroscopy-navigated screw insertion in the upper and subaxial cervical spine. Eur Spine J. 2015;24(12):2967\u201376.","journal-title":"Eur Spine J"},{"issue":"4","key":"5044_CR17","doi-asserted-by":"publisher","first-page":"803","DOI":"10.1007\/s00586-019-06242-4","volume":"29","author":"D Tkatschenko","year":"2020","unstructured":"Tkatschenko D, et al. Navigated percutaneous versus open pedicle screw implantation using intraoperative CT and robotic cone-beam CT imaging. Eur Spine J. 2020;29(4):803\u201312.","journal-title":"Eur Spine J"},{"key":"5044_CR18","doi-asserted-by":"crossref","unstructured":"Pojski\u0107 M et al. Initial Intraoperative Experience with Robotic-Assisted Pedicle Screw Placement with Cirq(\u00ae) Robotic Alignment: An Evaluation of the First 70 Screws. J Clin Med, 2021. 10(24).","DOI":"10.3390\/jcm10245725"},{"key":"5044_CR19","doi-asserted-by":"publisher","first-page":"e777","DOI":"10.1016\/j.wneu.2021.03.150","volume":"150","author":"K Farah","year":"2021","unstructured":"Farah K, et al. Robotic assistance for minimally invasive cervical pedicle instrumentation: report on feasibility and safety. World Neurosurg. 2021;150:e777\u201382.","journal-title":"World Neurosurg"},{"issue":"5","key":"5044_CR20","doi-asserted-by":"publisher","first-page":"543","DOI":"10.1302\/0301-620X.105B5.BJJ-2022-0810.R3","volume":"105\u2013b","author":"F Abel","year":"2023","unstructured":"Abel F, et al. Robotic-navigated assistance in spine surgery. Bone Joint J. 2023;105\u2013b(5):543\u201350.","journal-title":"Bone Joint J"},{"key":"5044_CR21","doi-asserted-by":"publisher","first-page":"101717","DOI":"10.1016\/j.bas.2023.101717","volume":"3","author":"N Gabrovsky","year":"2023","unstructured":"Gabrovsky N, Ilkov P, Laleva M. Cirq\u00ae robotic assistance for thoracolumbar pedicle screw placement - feasibility, accuracy, and safety. Brain Spine. 2023;3:101717.","journal-title":"Brain Spine"},{"key":"5044_CR22","doi-asserted-by":"crossref","unstructured":"Wang X et al. Effectiveness and safety of robot-assisted versus fluoroscopy-assisted cortical bone trajectory screw instrumentation in spinal surgery: a systematic review and meta-analysis. J Robotic Surg, 2024. 18(1).","DOI":"10.1007\/s11701-024-01866-1"},{"issue":"7","key":"5044_CR23","doi-asserted-by":"publisher","first-page":"647","DOI":"10.1016\/j.ejmp.2015.06.003","volume":"31","author":"P Alaei","year":"2015","unstructured":"Alaei P, Spezi E. Imaging dose from cone beam computed tomography in radiation therapy. Phys Med. 2015;31(7):647\u201358.","journal-title":"Phys Med"},{"issue":"1","key":"5044_CR24","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1097\/00007632-199001000-00004","volume":"15","author":"SD Gertzbein","year":"1990","unstructured":"Gertzbein SD, Robbins SE. Accuracy of pedicular screw placement in vivo. Spine (Phila Pa 1976). 1990;15(1):11\u20134.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"3","key":"5044_CR25","first-page":"e022","volume":"1","author":"I Onyekwelu","year":"2017","unstructured":"Onyekwelu I, et al. Surgical Wound classification and Surgical Site infections in the Orthopaedic Patient. J Am Acad Orthop Surg Glob Res Rev. 2017;1(3):e022.","journal-title":"J Am Acad Orthop Surg Glob Res Rev"},{"key":"5044_CR26","doi-asserted-by":"publisher","first-page":"e1220","DOI":"10.1016\/j.wneu.2023.04.102","volume":"175","author":"AJ Schupper","year":"2023","unstructured":"Schupper AJ, et al. Improving Surgeon Well-Being: Ergonomics in Neurosurgery. World Neurosurg. 2023;175:e1220\u20135.","journal-title":"World Neurosurg"},{"issue":"4","key":"5044_CR27","doi-asserted-by":"publisher","first-page":"587","DOI":"10.14444\/8474","volume":"17","author":"CL Mengis-Palleck","year":"2023","unstructured":"Mengis-Palleck CL, et al. Surgical Site infection after Polymethyl Methacrylate Pedicle Screw Augmentation in osteoporotic spinal vertebrae: a Series of 537 cases. Int J Spine Surg. 2023;17(4):587\u201397.","journal-title":"Int J Spine Surg"},{"issue":"6","key":"5044_CR28","doi-asserted-by":"publisher","first-page":"1553","DOI":"10.1007\/s00701-021-04744-z","volume":"163","author":"IK Janssen","year":"2021","unstructured":"Janssen IK, et al. Minimally invasive posterior pedicle screw fixation versus open instrumentation in patients with thoracolumbar spondylodiscitis. Acta Neurochir (Wien). 2021;163(6):1553\u201360.","journal-title":"Acta Neurochir (Wien)"},{"key":"5044_CR29","doi-asserted-by":"crossref","unstructured":"Akazawa T et al. Safety of robotic-assisted screw placement for spine surgery: experience from the initial 125 cases. J Orthop Sci, 2023.","DOI":"10.1016\/j.jos.2023.06.003"},{"issue":"2","key":"5044_CR30","first-page":"e54969","volume":"16","author":"B Jung","year":"2024","unstructured":"Jung B, et al. Robotic-assisted Versus Fluoroscopic-guided surgery on the Accuracy of Spine Pedicle Screw Placement: a systematic review and Meta-analysis. Cureus. 2024;16(2):e54969.","journal-title":"Cureus"},{"issue":"2","key":"5044_CR31","doi-asserted-by":"publisher","first-page":"447","DOI":"10.1007\/s00264-022-05508-9","volume":"47","author":"IB Lopez","year":"2023","unstructured":"Lopez IB, et al. Robotics in spine surgery: systematic review of literature. Int Orthop. 2023;47(2):447\u201356.","journal-title":"Int Orthop"},{"issue":"1","key":"5044_CR32","doi-asserted-by":"publisher","first-page":"66","DOI":"10.3171\/2022.7.SPINE22473","volume":"38","author":"RS Beyer","year":"2023","unstructured":"Beyer RS, et al. Spinal robotics in cervical spine surgery: a systematic review with key concepts and technical considerations. J Neurosurg Spine. 2023;38(1):66\u201374.","journal-title":"J Neurosurg Spine"},{"issue":"1","key":"5044_CR33","doi-asserted-by":"publisher","first-page":"118","DOI":"10.1007\/s10143-023-02027-y","volume":"46","author":"LP Zhou","year":"2023","unstructured":"Zhou LP, et al. Clinical application of spinal robot in cervical spine surgery: safety and accuracy of posterior pedicle screw placement in comparison with conventional freehand methods. Neurosurg Rev. 2023;46(1):118.","journal-title":"Neurosurg Rev"},{"issue":"1","key":"5044_CR34","doi-asserted-by":"publisher","first-page":"118","DOI":"10.1016\/j.spinee.2023.09.004","volume":"24","author":"T Asada","year":"2024","unstructured":"Asada T, et al. Robot-navigated pedicle screw insertion can reduce intraoperative blood loss and length of hospital stay: analysis of 1,633 patients utilizing propensity score matching. Spine J. 2024;24(1):118\u201324.","journal-title":"Spine J"},{"issue":"3","key":"5044_CR35","doi-asserted-by":"publisher","first-page":"343","DOI":"10.1016\/j.spinee.2015.11.020","volume":"16","author":"D Mendelsohn","year":"2016","unstructured":"Mendelsohn D, et al. Patient and surgeon radiation exposure during spinal instrumentation using intraoperative computed tomography-based navigation. Spine J. 2016;16(3):343\u201354.","journal-title":"Spine J"},{"issue":"1","key":"5044_CR36","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1016\/j.carj.2011.12.013","volume":"64","author":"IA Elbakri","year":"2013","unstructured":"Elbakri IA, Kirkpatrick ID. Dose-length product to effective dose conversion factors for common computed tomography examinations based on Canadian clinical experience. Can Assoc Radiol J. 2013;64(1):15\u20137.","journal-title":"Can Assoc Radiol J"},{"issue":"5","key":"5044_CR37","doi-asserted-by":"publisher","first-page":"2491","DOI":"10.1118\/1.3702457","volume":"39","author":"G Compagnone","year":"2012","unstructured":"Compagnone G, et al. Calculation of conversion factors for effective dose for various interventional radiology procedures. Med Phys. 2012;39(5):2491\u20138.","journal-title":"Med Phys"},{"issue":"3","key":"5044_CR38","doi-asserted-by":"publisher","first-page":"679","DOI":"10.2214\/AJR.19.22013","volume":"215","author":"DS Chen","year":"2020","unstructured":"Chen DS, et al. Dose-area product-to-effective dose Conversion coefficients for pelvic radiography using a Monte Carlo Program. AJR Am J Roentgenol. 2020;215(3):679\u201384.","journal-title":"AJR Am J Roentgenol"},{"issue":"9673","key":"5044_CR39","doi-asserted-by":"publisher","first-page":"1455","DOI":"10.1016\/S0140-6736(09)60232-4","volume":"373","author":"S Huber-Wagner","year":"2009","unstructured":"Huber-Wagner S, et al. Effect of whole-body CT during trauma resuscitation on survival: a retrospective, multicentre study. Lancet. 2009;373(9673):1455\u201361.","journal-title":"Lancet"},{"issue":"7","key":"5044_CR40","doi-asserted-by":"publisher","first-page":"2400","DOI":"10.1016\/j.injury.2022.04.009","volume":"53","author":"HC Pape","year":"2022","unstructured":"Pape HC, et al. Pathophysiology in patients with polytrauma. Injury. 2022;53(7):2400\u201312.","journal-title":"Injury"},{"issue":"9","key":"5044_CR41","doi-asserted-by":"publisher","first-page":"977","DOI":"10.1097\/00007632-199705010-00009","volume":"22","author":"EL Jones","year":"1997","unstructured":"Jones EL, et al. Cervical pedicle screws versus lateral mass screws. Anatomic feasibility and biomechanical comparison. Spine (Phila Pa 1976). 1997;22(9):977\u201382.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"1","key":"5044_CR42","doi-asserted-by":"publisher","first-page":"329","DOI":"10.14245\/ns.2244952.476","volume":"20","author":"LP Zhou","year":"2023","unstructured":"Zhou LP, et al. Robotics in cervical spine surgery: feasibility and safety of posterior screw Placement. Neurospine. 2023;20(1):329\u201339.","journal-title":"Neurospine"},{"issue":"5","key":"5044_CR43","doi-asserted-by":"publisher","first-page":"753","DOI":"10.1016\/j.jcot.2020.04.034","volume":"11","author":"B Garg","year":"2020","unstructured":"Garg B, Mehta N, Malhotra R. Robotic spine surgery: ushering in a new era. J Clin Orthop Trauma. 2020;11(5):753\u201360.","journal-title":"J Clin Orthop Trauma"},{"issue":"6","key":"5044_CR44","doi-asserted-by":"publisher","first-page":"730","DOI":"10.1093\/ons\/opaa208","volume":"19","author":"K Farah","year":"2020","unstructured":"Farah K, et al. Cirq\u00ae Robotic assistance for minimally invasive C1-C2 posterior instrumentation: report on feasibility and safety. Oper Neurosurg (Hagerstown). 2020;19(6):730\u20134.","journal-title":"Oper Neurosurg (Hagerstown)"},{"key":"5044_CR45","doi-asserted-by":"crossref","unstructured":"Wu J et al. Accuracy and clinical characteristics of robot-assisted cervical spine surgery: a systematic review and meta-analysis. Int Orthop, 2024.","DOI":"10.1007\/s00264-024-06179-4"},{"issue":"4","key":"5044_CR46","doi-asserted-by":"publisher","first-page":"893","DOI":"10.1007\/s11701-021-01313-5","volume":"16","author":"K Chesney","year":"2022","unstructured":"Chesney K, et al. Cirq robotic arm-assisted transpedicular instrumentation with intraoperative navigation: technical note and case series with 714 thoracolumbar screws. J Robot Surg. 2022;16(4):893\u20138.","journal-title":"J Robot Surg"},{"issue":"24","key":"5044_CR47","doi-asserted-by":"publisher","first-page":"2109","DOI":"10.1097\/BRS.0b013e3181d323ab","volume":"35","author":"DP Devito","year":"2010","unstructured":"Devito DP, et al. Clinical acceptance and accuracy assessment of spinal implants guided with SpineAssist surgical robot: retrospective study. Spine (Phila Pa 1976). 2010;35(24):2109\u201315.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"3","key":"5044_CR48","doi-asserted-by":"publisher","first-page":"242","DOI":"10.1227\/ons.0000000000000498","volume":"24","author":"CW Kanaly","year":"2023","unstructured":"Kanaly CW, et al. A retrospective analysis of Pedicle Screw Placement Accuracy using the ExcelsiusGPS Robotic Guidance System: Case Series. Oper Neurosurg (Hagerstown). 2023;24(3):242\u20137.","journal-title":"Oper Neurosurg (Hagerstown)"},{"issue":"3","key":"5044_CR49","doi-asserted-by":"publisher","first-page":"409","DOI":"10.1007\/s11701-019-00994-3","volume":"14","author":"AB Vardiman","year":"2020","unstructured":"Vardiman AB, et al. Pedicle screw accuracy in clinical utilization of minimally invasive navigated robot-assisted spine surgery. J Robot Surg. 2020;14(3):409\u201313.","journal-title":"J Robot Surg"},{"key":"5044_CR50","doi-asserted-by":"publisher","first-page":"664","DOI":"10.1016\/j.wneu.2019.02.217","volume":"126","author":"A Perdomo-Pantoja","year":"2019","unstructured":"Perdomo-Pantoja A, et al. Accuracy of current techniques for Placement of Pedicle screws in the spine: a comprehensive systematic review and Meta-analysis of 51,161 screws. World Neurosurg. 2019;126:664\u2013e6783.","journal-title":"World Neurosurg"},{"issue":"11","key":"5044_CR51","doi-asserted-by":"crossref","first-page":"791","DOI":"10.1097\/BRS.0000000000004604","volume":"48","author":"A Naik","year":"2023","unstructured":"Naik A, et al. Trends in Technology for Pedicle Screw Placement: a temporal Meta-analysis. Spine (Phila Pa 1976). 2023;48(11):791\u20139.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"11s","key":"5044_CR52","doi-asserted-by":"publisher","first-page":"S28","DOI":"10.1097\/BOT.0000000000002691","volume":"37","author":"S Gilani","year":"2023","unstructured":"Gilani S, et al. The Use of a robotic arm for fixation of pelvic fractures. J Orthop Trauma. 2023;37(11s):S28\u201332.","journal-title":"J Orthop Trauma"},{"issue":"12","key":"5044_CR53","doi-asserted-by":"publisher","first-page":"2464","DOI":"10.12998\/wjcc.v8.i12.2464","volume":"8","author":"T Yu","year":"2020","unstructured":"Yu T, et al. Computer navigation-assisted minimally invasive percutaneous screw placement for pelvic fractures. World J Clin Cases. 2020;8(12):2464\u201372.","journal-title":"World J Clin Cases"},{"issue":"4","key":"5044_CR54","doi-asserted-by":"publisher","first-page":"e153","DOI":"10.1097\/OI9.0000000000000153","volume":"4","author":"HJ Schuijt","year":"2021","unstructured":"Schuijt HJ, et al. Robot-assisted fracture fixation in orthopaedic trauma surgery: a systematic review. OTA Int. 2021;4(4):e153.","journal-title":"OTA Int"},{"issue":"6","key":"5044_CR55","doi-asserted-by":"publisher","first-page":"1401","DOI":"10.1007\/s11701-022-01381-1","volume":"16","author":"MA K\u00fcper","year":"2022","unstructured":"K\u00fcper MA, et al. Robotic-assisted plate osteosynthesis of the anterior pelvic ring and acetabulum: an anatomical feasibility study. J Robot Surg. 2022;16(6):1401\u20137.","journal-title":"J Robot Surg"},{"issue":"6","key":"5044_CR56","doi-asserted-by":"publisher","first-page":"e7527","DOI":"10.1002\/ccr3.7527","volume":"11","author":"AF Smith","year":"2023","unstructured":"Smith AF, Carlson JB. Robotic-assisted percutaneous pelvis fixation: a case report. Clin Case Rep. 2023;11(6):e7527.","journal-title":"Clin Case Rep"},{"issue":"3","key":"5044_CR57","doi-asserted-by":"publisher","first-page":"326","DOI":"10.21037\/jss-21-14","volume":"7","author":"NJ Lee","year":"2021","unstructured":"Lee NJ, et al. The accuracy of robot-assisted S2 alar-iliac screw placement at two different healthcare centers. J Spine Surg. 2021;7(3):326\u201334.","journal-title":"J Spine Surg"},{"issue":"2","key":"5044_CR58","doi-asserted-by":"publisher","first-page":"130","DOI":"10.1016\/j.jspd.2017.08.009","volume":"6","author":"JL Laratta","year":"2018","unstructured":"Laratta JL, et al. Accuracy of S2 Alar-Iliac Screw Placement under Robotic Guidance. Spine Deform. 2018;6(2):130\u20136.","journal-title":"Spine Deform"},{"issue":"1","key":"5044_CR59","doi-asserted-by":"publisher","first-page":"E49","DOI":"10.1097\/BSD.0b013e3182a3572b","volume":"30","author":"SS Bederman","year":"2017","unstructured":"Bederman SS, et al. Robotic Guidance for S2-Alar-iliac screws in spinal deformity correction. Clin Spine Surg. 2017;30(1):E49\u201353.","journal-title":"Clin Spine Surg"},{"issue":"2suppl","key":"5044_CR60","doi-asserted-by":"publisher","first-page":"s45","DOI":"10.1177\/21925682211036664","volume":"12","author":"A Arora","year":"2022","unstructured":"Arora A, Berven S. Challenges and complications in Freehand S2-Alar-iliac spinopelvic fixation and the potential for Robotics to Enhance Patient Safety. Global Spine J. 2022;12(2suppl):s45\u201352.","journal-title":"Global Spine J"},{"issue":"1","key":"5044_CR61","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1007\/s10143-018-0971-z","volume":"43","author":"B Fiani","year":"2020","unstructured":"Fiani B, et al. Impact of robot-assisted spine surgery on health care quality and neurosurgical economics: a systemic review. Neurosurg Rev. 2020;43(1):17\u201325.","journal-title":"Neurosurg Rev"},{"issue":"5","key":"5044_CR62","doi-asserted-by":"publisher","first-page":"850","DOI":"10.1111\/os.12534","volume":"11","author":"Q Zhang","year":"2019","unstructured":"Zhang Q, et al. Comparison of Superior-Level Facet Joint violations between Robot-assisted Percutaneous Pedicle Screw Placement and Conventional Open fluoroscopic-guided Pedicle Screw Placement. Orthop Surg. 2019;11(5):850\u20136.","journal-title":"Orthop Surg"},{"issue":"5","key":"5044_CR63","doi-asserted-by":"publisher","first-page":"179","DOI":"10.1097\/BSD.0000000000000809","volume":"33","author":"DP Ahern","year":"2020","unstructured":"Ahern DP, et al. Image-guidance, Robotics, and the future of spine surgery. Clin Spine Surg. 2020;33(5):179\u201384.","journal-title":"Clin Spine Surg"},{"issue":"5","key":"5044_CR64","doi-asserted-by":"publisher","first-page":"285","DOI":"10.1097\/BRS.0000000000003258","volume":"45","author":"M Fan","year":"2020","unstructured":"Fan M, et al. Improved accuracy of cervical spinal surgery with Robot-assisted screw insertion: a prospective, randomized, controlled study. Spine (Phila Pa 1976). 2020;45(5):285\u201391.","journal-title":"Spine (Phila Pa 1976)"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-024-05044-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13018-024-05044-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-024-05044-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,28]],"date-time":"2024-11-28T03:37:19Z","timestamp":1732765039000},"score":1,"resource":{"primary":{"URL":"https:\/\/josr-online.biomedcentral.com\/articles\/10.1186\/s13018-024-05044-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,9,14]]},"references-count":64,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["5044"],"URL":"https:\/\/doi.org\/10.1186\/s13018-024-05044-9","relation":{},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,9,14]]},"assertion":[{"value":"14 July 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 August 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 September 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"approval (Reference No. F-2024-037) from the responsible authority, the Landes\u00e4rztekammer Baden-W\u00fcrttemberg (Germany).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}},{"value":"not applicable.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"S.H.-W. received reimbursement of travel expenses for lectures given by Brainlab.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"565"}}