{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,20]],"date-time":"2026-01-20T01:12:06Z","timestamp":1768871526836,"version":"3.49.0"},"reference-count":38,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,11,28]],"date-time":"2024-11-28T00:00:00Z","timestamp":1732752000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,11,28]],"date-time":"2024-11-28T00:00:00Z","timestamp":1732752000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Universit\u00e4tsklinikum RWTH Aachen"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Titanium plantar plates have proven successful in the fixation of the first tarsometatarsal arthrodesis (TMT). However, a second surgery is typically needed for implant removal, and potential adverse effects, carried by the conventional implantations, are not uncommon. The purpose of this study was to determine whether a novel magnesium-based plantar plate system provides similar fusion stability to a titanium-based plantar plate system under various loading conditions.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Six matched-pair human cadaveric specimens underwent TMT fusions using either a magnesium plantar plate system prototype or a titanium plantar plate system. Specimens were cyclically loaded with a force ranging from 5\u00a0N to 50\u00a0N for 5,000 cycles, and displacement was recorded. Axial stiffness (N\/mm) was calculated from load-displacement curves. Each specimen was loaded to failure at a rate of 5\u00a0mm\/min, and the ultimate load was recorded.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>No significant difference was found in the vertical displacement between Ti group and Mg group after 100 cycles (2.4\u2009\u00b1\u20091.0\u00a0mm vs. 1.3\u2009\u00b1\u20091.4\u00a0mm, <jats:italic>p<\/jats:italic>\u2009=\u20090.196), 500 cycles (3.3\u2009\u00b1\u20091.3\u00a0mm vs. 1.7\u2009\u00b1\u20091.7\u00a0mm, <jats:italic>p<\/jats:italic>\u2009=\u20090.142), 1,000 cycles (3.7\u2009\u00b1\u20091.5\u00a0mm vs. 1.9\u2009\u00b1\u20091.9\u00a0mm, <jats:italic>p<\/jats:italic>\u2009=\u20090.128), 2,500 cycles (4.2\u2009\u00b1\u20091.7\u00a0mm vs. 2.3\u2009\u00b1\u20092.2\u00a0mm, <jats:italic>p<\/jats:italic>\u2009=\u20090.172) and 5,000 cycles (4.5\u2009\u00b1\u20091.8\u00a0mm vs. 2.3\u2009\u00b1\u20093.3\u00a0mm, <jats:italic>p<\/jats:italic>\u2009=\u20090.125), Additionally, no significant differences were observed in initial stiffness (53.1\u2009\u00b1\u200919.2\u00a0N\/mm vs. 82.2\u2009\u00b1\u200953.9\u00a0N\/mm, <jats:italic>p<\/jats:italic>\u2009=\u20090.257), final stiffness (90.6\u2009\u00b1\u200948.9\u00a0N\/mm vs. 120.0\u2009\u00b1\u200948.3\u00a0N\/mm, <jats:italic>p<\/jats:italic>\u2009=\u20090.319), or maximum load-to-failure (259.8\u2009\u00b1\u200998.2\u00a0N vs. 323.9\u2009\u00b1\u2009134.9\u00a0N, <jats:italic>p<\/jats:italic>\u2009=\u20090.369).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Based on the performed biomechanical testing, the magnesium plantar plate system provides mechanical stability equivalent to the titanium plantar plate system in fixation for the first TMT joint fusion.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s13018-024-05208-7","type":"journal-article","created":{"date-parts":[[2024,11,28]],"date-time":"2024-11-28T07:26:17Z","timestamp":1732778777000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Biomechanical analysis of a magnesium plantar plate prototype system for the first tarsometatarsal joint fusion: a cadaveric study"],"prefix":"10.1186","volume":"19","author":[{"given":"Peng","family":"Zhou","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marx","family":"Ribeiro","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Johannes","family":"Greven","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maximilian","family":"Praster","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jan-Marten","family":"Seitz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Simon","family":"Habicht","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Frank","family":"Hildebrand","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Elizabeth R.","family":"Balmayor","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Philipp","family":"Lichte","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2024,11,28]]},"reference":[{"key":"5208_CR1","first-page":"14","volume":"10","author":"GH Albrecht","year":"2023","unstructured":"Albrecht GH. The pathology and treatment of hallux valgus. Russk Vrach. 2023;10:14\u20139.","journal-title":"Russk Vrach"},{"key":"5208_CR2","first-page":"98","volume":"7","author":"W Truslow","year":"1925","unstructured":"Truslow W. Metatarsus primus varus or hallux valgus? J Bone Joint Surg. 1925;7:98\u2013108.","journal-title":"J Bone Joint Surg"},{"issue":"2","key":"5208_CR3","first-page":"404","volume":"17","author":"PW Lapidus","year":"1956","unstructured":"Lapidus PW. A quarter of a century of experience with the operative correction of the metatarsus varus primus in hallux valgus. Bull Hosp Joint Dis. 1956;17(2):404\u201321.","journal-title":"Bull Hosp Joint Dis"},{"key":"5208_CR4","doi-asserted-by":"crossref","unstructured":"Bednarz PA, Manoli A 2. Modified lapidus procedure for the treatment of hypermobile hallux valgus. Foot Ankle Int. 2000;21(10):816\u201321.","DOI":"10.1177\/107110070002101004"},{"issue":"2","key":"5208_CR5","doi-asserted-by":"publisher","first-page":"195","DOI":"10.1007\/s00064-005-1129-z","volume":"17","author":"RA Fuhrmann","year":"2005","unstructured":"Fuhrmann RA. Arthrodesis of the first tarsometatarsal joint for correction of the advanced splayfoot accompanied by a hallux valgus. Operative Orthopadie Und Traumatologie. 2005;17(2):195\u2013210.","journal-title":"Operative Orthopadie Und Traumatologie"},{"issue":"1","key":"5208_CR6","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1055\/s-0029-1202591","volume":"2","author":"MS Gilardino","year":"2009","unstructured":"Gilardino MS, Chen E, Bartlett SP. Choice of internal rigid fixation materials in the treatment of facial fractures. Craniomaxillofacial Trauma Reconstruction. 2009;2(1):49\u201360.","journal-title":"Craniomaxillofacial Trauma Reconstruction"},{"key":"5208_CR7","doi-asserted-by":"crossref","unstructured":"Waehner M, Klos K, Polzer H, Ray R, Lorchan Lewis T, Waizy H. Lapidus Arthrodesis for correction of Hallux Valgus deformity: a systematic review and Meta-analysis. Foot Ankle Spec. 2024;19386400241233832.","DOI":"10.1177\/19386400241233832"},{"issue":"5","key":"5208_CR8","doi-asserted-by":"publisher","first-page":"1338","DOI":"10.1097\/SCS.0000000000006352","volume":"31","author":"S Sukegawa","year":"2020","unstructured":"Sukegawa S, Masui M, Sukegawa-Takahashi Y, Nakano K, Takabatake K, Kawai H, Nagatsuka H, Furuki Y. Maxillofacial trauma surgery patients with Titanium Osteosynthesis miniplates: remove or not? J Craniofac Surg. 2020;31(5):1338\u201342.","journal-title":"J Craniofac Surg"},{"issue":"1","key":"5208_CR9","doi-asserted-by":"publisher","first-page":"171","DOI":"10.1023\/B:ABME.0000007802.59936.fc","volume":"32","author":"CG Ambrose","year":"2004","unstructured":"Ambrose CG, Clanton TO. Bioabsorbable implants: review of clinical experience in orthopedic surgery. Ann Biomed Eng. 2004;32(1):171\u20137.","journal-title":"Ann Biomed Eng"},{"issue":"2","key":"5208_CR10","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1002\/mco2.59","volume":"2","author":"S Amukarimi","year":"2021","unstructured":"Amukarimi S, Mozafari M. Biodegradable magnesium-based biomaterials: an overview of challenges and opportunities. MedComm. 2021;2(2):123\u201344.","journal-title":"MedComm"},{"issue":"1","key":"5208_CR11","doi-asserted-by":"publisher","first-page":"329","DOI":"10.1002\/jbm.a.35893","volume":"105","author":"E Willbold","year":"2017","unstructured":"Willbold E, Weizbauer A, Loos A, Seitz JM, Angrisani N, Windhagen H, Reifenrath J. Magnesium alloys: a stony pathway from intensive research to clinical reality. Different test methods and approval-related considerations. J Biomed Mater Res A. 2017;105(1):329\u201347.","journal-title":"J Biomed Mater Res A"},{"key":"5208_CR12","doi-asserted-by":"crossref","unstructured":"Hussain M, Khan SM, Shafiq M, Abbas N, Sajjad U, Hamid K. Advances in biodegradable materials: degradation mechanisms, mechanical properties, and biocompatibility for orthopedic applications. Heliyon. 2024;10(12):e32713.","DOI":"10.1016\/j.heliyon.2024.e32713"},{"issue":"8","key":"5208_CR13","first-page":"1902443","volume":"7","author":"JL Wang","year":"2020","unstructured":"Wang JL, Xu JK, Hopkins C, Chow DH, Qin L. Biodegradable magnesium-based implants in Orthopedics-A General Review and perspectives. Adv Sci (Weinheim Baden-Wurttemberg Germany). 2020;7(8):1902443.","journal-title":"Adv Sci (Weinheim Baden-Wurttemberg Germany)"},{"issue":"10","key":"5208_CR14","doi-asserted-by":"publisher","first-page":"1160","DOI":"10.1038\/nm.4162","volume":"22","author":"Y Zhang","year":"2016","unstructured":"Zhang Y, Xu J, Ruan YC, Yu MK, O\u2019Laughlin M, Wise H, Chen D, Tian L, Shi D, Wang J, Chen S, Feng JQ, Chow DH, Xie X, Zheng L, Huang L, Huang S, Leung K, Lu N, Zhao L, Li H, Zhao D, Guo X, Chan K, Witte F, Chan HC, Zheng Y, Qin L. Implant-derived magnesium induces local neuronal production of CGRP to improve bone-fracture healing in rats. Nat Med. 2016;22(10):1160\u20139.","journal-title":"Nat Med"},{"key":"5208_CR15","doi-asserted-by":"publisher","first-page":"393","DOI":"10.1016\/j.actbio.2017.09.018","volume":"63","author":"J Wang","year":"2017","unstructured":"Wang J, Xu J, Song B, Chow DH, Shu-Hang Yung P, Qin L. Magnesium (mg) based interference screws developed for promoting tendon graft incorporation in bone tunnel in rabbits. Acta Biomater. 2017;63:393\u2013410.","journal-title":"Acta Biomater"},{"issue":"11","key":"5208_CR16","doi-asserted-by":"publisher","first-page":"1057","DOI":"10.2106\/JBJS.J.00160","volume":"93","author":"JJ Schreiber","year":"2011","unstructured":"Schreiber JJ, Anderson PA, Rosas HG, Buchholz AL, Au AG. Hounsfield units for assessing bone mineral density and strength: a tool for osteoporosis management. J Bone Joint Surg Am Vol. 2011;93(11):1057\u201363.","journal-title":"J Bone Joint Surg Am Vol"},{"issue":"1","key":"5208_CR17","doi-asserted-by":"publisher","first-page":"176","DOI":"10.1186\/s13018-018-0876-0","volume":"13","author":"R Burchard","year":"2018","unstructured":"Burchard R, Massa R, Soost C, Richter W, Dietrich G, Ohrndorf A, Christ HJ, Fritzen CP, Graw JA, Schmitt J. Biomechanics of common fixation devices for first tarsometatarsal joint fusion-a comparative study with synthetic bones. J Orthop Surg Res. 2018;13(1):176.","journal-title":"J Orthop Surg Res"},{"key":"5208_CR18","doi-asserted-by":"publisher","first-page":"17","DOI":"10.3352\/jeehp.2021.18.17","volume":"18","author":"H Kang","year":"2021","unstructured":"Kang H. Sample size determination and power analysis using the G*Power software. J Educational Evaluation Health Professions. 2021;18:17.","journal-title":"J Educational Evaluation Health Professions"},{"issue":"1","key":"5208_CR19","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1186\/s13018-016-0435-5","volume":"11","author":"PJ Switaj","year":"2016","unstructured":"Switaj PJ, Fuchs D, Alshouli M, Patwardhan AG, Voronov LI, Muriuki M, Havey RM, Kadakia AR. A biomechanical comparison study of a modern fibular nail and distal fibular locking plate in AO\/OTA 44C2 ankle fractures. J Orthop Surg Res. 2016;11(1):100.","journal-title":"J Orthop Surg Res"},{"issue":"1","key":"5208_CR20","doi-asserted-by":"publisher","first-page":"80","DOI":"10.1053\/j.jfas.2022.05.002","volume":"62","author":"JM Stowers","year":"2023","unstructured":"Stowers JM, Black AT, Kavanagh AM, Mata K, Eshetu T. Bone density by specific anatomic location using Hounsfield samples of the Lower extremity: a multi-center retrospective analysis. J foot Ankle Surgery: Official Publication Am Coll Foot Ankle Surg. 2023;62(1):80\u20134.","journal-title":"J foot Ankle Surgery: Official Publication Am Coll Foot Ankle Surg"},{"issue":"3","key":"5208_CR21","doi-asserted-by":"publisher","first-page":"466","DOI":"10.1053\/j.jfas.2017.10.025","volume":"57","author":"D Drummond","year":"2018","unstructured":"Drummond D, Motley T, Kosmopoulos V, Ernst J. Stability of Locking Plate and Compression Screws for Lapidus Arthrodesis: a Biomechanical comparison of plate position. J foot Ankle Surgery: Official Publication Am Coll Foot Ankle Surg. 2018;57(3):466\u201370.","journal-title":"J foot Ankle Surgery: Official Publication Am Coll Foot Ankle Surg"},{"key":"5208_CR22","doi-asserted-by":"crossref","unstructured":"Klos K, Simons P, Schopp P, Schenk P, Kohler FC, Uddin A, Roth EK, Biedermann U, Hofmann GO, Lenz M. Biomechanical comparison of medio-plantar and plantar plate fixation for first tarsometatarsal joint arthrodesis. J Clin Med. 2023;12(12).","DOI":"10.3390\/jcm12123896"},{"issue":"4","key":"5208_CR23","doi-asserted-by":"publisher","first-page":"322","DOI":"10.1177\/1938640016679698","volume":"10","author":"AR Knutsen","year":"2017","unstructured":"Knutsen AR, Fleming JF, Ebramzadeh E, Ho NC, Warganich T, Harris TG, Sangiorgio SN. Biomechanical comparison of fixation devices for first metatarsocuneiform joint arthrodesis. Foot Ankle Spec. 2017;10(4):322\u20138.","journal-title":"Foot Ankle Spec"},{"issue":"11","key":"5208_CR24","doi-asserted-by":"publisher","first-page":"1081","DOI":"10.3113\/FAI.2011.1081","volume":"32","author":"K Klos","year":"2011","unstructured":"Klos K, Simons P, Hajduk AS, Hoffmeier KL, Gras F, Fr\u00f6ber R, Hofmann GO, M\u00fcckley T. Plantar versus dorsomedial locked plating for Lapidus arthrodesis: a biomechanical comparison. Foot Ankle Int. 2011;32(11):1081\u20135.","journal-title":"Foot Ankle Int"},{"issue":"5","key":"5208_CR25","doi-asserted-by":"publisher","first-page":"1680","DOI":"10.1016\/j.actbio.2010.02.028","volume":"6","author":"F Witte","year":"2010","unstructured":"Witte F. The history of biodegradable magnesium implants: a review. Acta Biomater. 2010;6(5):1680\u201392.","journal-title":"Acta Biomater"},{"issue":"9","key":"5208_CR26","doi-asserted-by":"publisher","first-page":"1728","DOI":"10.1016\/j.biomaterials.2005.10.003","volume":"27","author":"MP Staiger","year":"2006","unstructured":"Staiger MP, Pietak AM, Huadmai J, Dias G. Magnesium and its alloys as orthopedic biomaterials: a review. Biomaterials. 2006;27(9):1728\u201334.","journal-title":"Biomaterials"},{"issue":"1","key":"5208_CR27","doi-asserted-by":"publisher","first-page":"432","DOI":"10.1016\/j.actbio.2010.08.020","volume":"7","author":"C Castellani","year":"2011","unstructured":"Castellani C, Lindtner RA, Hausbrandt P, Tschegg E, Stanzl-Tschegg SE, Zanoni G, Beck S, Weinberg AM. Bone-implant interface strength and osseointegration: biodegradable magnesium alloy versus standard titanium control. Acta Biomater. 2011;7(1):432\u201340.","journal-title":"Acta Biomater"},{"key":"5208_CR28","doi-asserted-by":"crossref","unstructured":"Fischer H, Schmidt-Bleek O, Orassi V, Wulsten D, Schmidt-Bleek K, Heiland M, Steffen C, Rendenbach C. Biomechanical comparison of WE43-based magnesium vs. titanium miniplates in a mandible fracture model in sheep. Materials (Basel, Switzerland). 2022;16(1).","DOI":"10.3390\/ma16010102"},{"key":"5208_CR29","doi-asserted-by":"publisher","first-page":"803103","DOI":"10.3389\/fbioe.2021.803103","volume":"9","author":"V Orassi","year":"2021","unstructured":"Orassi V, Fischer H, Duda GN, Heiland M, Checa S, Rendenbach C. In Silico Biomechanical evaluation of WE43 magnesium plates for mandibular fracture fixation. Front Bioeng Biotechnol. 2021;9:803103.","journal-title":"Front Bioeng Biotechnol"},{"key":"5208_CR30","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1016\/j.actbio.2017.11.031","volume":"66","author":"T Kraus","year":"2018","unstructured":"Kraus T, Fischerauer S, Treichler S, Martinelli E, Eichler J, Myrissa A, Z\u00f6tsch S, Uggowitzer PJ, L\u00f6ffler JF, Weinberg AM. The influence of biodegradable magnesium implants on the growth plate. Acta Biomater. 2018;66:109\u201317.","journal-title":"Acta Biomater"},{"issue":"1","key":"5208_CR31","doi-asserted-by":"publisher","first-page":"334","DOI":"10.1186\/s12891-019-2717-7","volume":"20","author":"HD Atkinson","year":"2019","unstructured":"Atkinson HD, Khan S, Lashgari Y, Ziegler A. Hallux valgus correction utilising a modified short scarf osteotomy with a magnesium biodegradable or titanium compression screws - a comparative study of clinical outcomes. BMC Musculoskelet Disord. 2019;20(1):334.","journal-title":"BMC Musculoskelet Disord"},{"key":"5208_CR32","doi-asserted-by":"publisher","first-page":"62","DOI":"10.1186\/1475-925X-12-62","volume":"12","author":"H Windhagen","year":"2013","unstructured":"Windhagen H, Radtke K, Weizbauer A, Diekmann J, Noll Y, Kreimeyer U, Schavan R, Stukenborg-Colsman C, Waizy H. Biodegradable magnesium-based screw clinically equivalent to titanium screw in hallux valgus surgery: short term results of the first prospective, randomized, controlled clinical pilot study. Biomed Eng Online. 2013;12:62.","journal-title":"Biomed Eng Online"},{"issue":"2","key":"5208_CR33","doi-asserted-by":"publisher","first-page":"321","DOI":"10.1016\/j.jos.2017.11.005","volume":"23","author":"C Plaass","year":"2018","unstructured":"Plaass C, von Falck C, Ettinger S, Sonnow L, Calderone F, Weizbauer A, Reifenrath J, Claassen L, Waizy H, Daniilidis K, Stukenborg-Colsman C, Windhagen H. Bioabsorbable magnesium versus standard titanium compression screws for fixation of distal metatarsal osteotomies \u2013\u20093 year results of a randomized clinical trial. J Orthop Science: Official J Japanese Orthop Association. 2018;23(2):321\u20137.","journal-title":"J Orthop Science: Official J Japanese Orthop Association"},{"key":"5208_CR34","doi-asserted-by":"publisher","first-page":"329","DOI":"10.1186\/s12891-015-0790-0","volume":"16","author":"X Yu","year":"2015","unstructured":"Yu X, Zhao D, Huang S, Wang B, Zhang X, Wang W, Wei X. Biodegradable magnesium screws and vascularized iliac grafting for displaced femoral neck fracture in young adults. BMC Musculoskelet Disord. 2015;16:329.","journal-title":"BMC Musculoskelet Disord"},{"key":"5208_CR35","doi-asserted-by":"publisher","first-page":"rbad095","DOI":"10.1093\/rb\/rbad095","volume":"10","author":"I Antoniac","year":"2023","unstructured":"Antoniac I, Manescu Paltanea V, Antoniac A, Paltanea G. Magnesium-based alloys with adapted interfaces for bone implants and tissue engineering. Regenerative Biomaterials. 2023;10:rbad095.","journal-title":"Regenerative Biomaterials"},{"issue":"2","key":"5208_CR36","doi-asserted-by":"publisher","first-page":"289","DOI":"10.52312\/jdrs.2023.1026","volume":"34","author":"X Fu","year":"2023","unstructured":"Fu X, Wang GX, Wang CG, Li ZJ. Comparison between bioabsorbable magnesium and titanium compression screws for hallux valgus treated with distal metatarsal osteotomies: a meta-analysis. Joint Dis Relat Surg. 2023;34(2):289\u201397.","journal-title":"Joint Dis Relat Surg"},{"issue":"5","key":"5208_CR37","doi-asserted-by":"publisher","first-page":"1824","DOI":"10.1016\/j.actbio.2009.10.008","volume":"6","author":"AC H\u00e4nzi","year":"2010","unstructured":"H\u00e4nzi AC, Gerber I, Schinhammer M, L\u00f6ffler JF, Uggowitzer PJ. On the in vitro and in vivo degradation performance and biological response of new biodegradable Mg-Y-Zn alloys. Acta Biomater. 2010;6(5):1824\u201333.","journal-title":"Acta Biomater"},{"key":"5208_CR38","doi-asserted-by":"crossref","unstructured":"Chakraborty Banerjee P, Al-Saadi S, Choudhary L, Harandi SE, Singh R. Magnesium implants: prospects and challenges. Materials (Basel, Switzerland). 2019;12(1).","DOI":"10.3390\/ma12010136"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-024-05208-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13018-024-05208-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-024-05208-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,28]],"date-time":"2024-11-28T09:16:55Z","timestamp":1732785415000},"score":1,"resource":{"primary":{"URL":"https:\/\/josr-online.biomedcentral.com\/articles\/10.1186\/s13018-024-05208-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,11,28]]},"references-count":38,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["5208"],"URL":"https:\/\/doi.org\/10.1186\/s13018-024-05208-7","relation":{},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,11,28]]},"assertion":[{"value":"25 July 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 October 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 November 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This research was reviewed and approved by the Institutional Review Board at University Hospital RWTH Aachen (EK 048\u2009\u2212\u200921).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"Jan-Marten Seitz and Simon Habicht are paid employees from Medical Magnesium GmbH. The other authors declared no potential conflicts of interest with respect to the research, authorship, and\/or publication of this article.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"802"}}