{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,29]],"date-time":"2026-07-29T07:08:04Z","timestamp":1785308884807,"version":"3.55.0"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,12,19]],"date-time":"2024-12-19T00:00:00Z","timestamp":1734566400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2024,12,19]],"date-time":"2024-12-19T00:00:00Z","timestamp":1734566400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"DOI":"10.1186\/s13018-024-05316-4","type":"journal-article","created":{"date-parts":[[2024,12,19]],"date-time":"2024-12-19T03:29:01Z","timestamp":1734578941000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Kinematic status of Bryan and Mobi-C artificial cervical discs post cervical hybrid surgery: a retrospective study"],"prefix":"10.1186","volume":"19","author":[{"given":"Yukun","family":"Ma","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yang","family":"Xiong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ting","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xing","family":"Yu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chuanhong","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Letian","family":"Meng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"He","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yongdong","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dingyan","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fengxian","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yi","family":"Qu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,12,19]]},"reference":[{"issue":"2","key":"5316_CR1","doi-asserted-by":"publisher","first-page":"546","DOI":"10.1007\/s00586-016-4791-y","volume":"26","author":"VM Lu","year":"2017","unstructured":"Lu VM, Zhang L, Scherman DB, Rao PJ, Mobbs RJ, Phan K. Treating multi-level cervical disc disease with hybrid surgery compared to anterior cervical discectomy and fusion: a systematic review and meta-analysis. Eur Spine J. 2017;26(2):546\u201357. https:\/\/doi.org\/10.1007\/s00586-016-4791-y.","journal-title":"Eur Spine J"},{"issue":"8","key":"5316_CR2","doi-asserted-by":"publisher","first-page":"1619","DOI":"10.1007\/s00586-014-3389-5","volume":"23","author":"Z Jia","year":"2014","unstructured":"Jia Z, Mo Z, Ding F, He Q, Fan Y, Ruan D. Hybrid surgery for multilevel cervical degenerative disc diseases: a systematic review of biomechanical and clinical evidence. Eur Spine J. 2014;23(8):1619\u201332. https:\/\/doi.org\/10.1007\/s00586-014-3389-5.","journal-title":"Eur Spine J"},{"issue":"34","key":"5316_CR3","doi-asserted-by":"publisher","first-page":"e11973","DOI":"10.1097\/MD.0000000000011973","volume":"97","author":"CM Zhao","year":"2018","unstructured":"Zhao CM, Chen Q, Zhang Y, Huang AB, Ding WY, Zhang W. Anterior cervical discectomy and fusion versus hybrid surgery in multilevel cervical spondylotic myelopathy: a meta-analysis. Med (Baltim). 2018;97(34):e11973. https:\/\/doi.org\/10.1097\/MD.0000000000011973.","journal-title":"Med (Baltim)"},{"key":"5316_CR4","doi-asserted-by":"publisher","first-page":"13454","DOI":"10.1038\/srep13454","volume":"5","author":"P Tian","year":"2015","unstructured":"Tian P, Fu X, Li ZJ, Sun XL, Ma XL. Hybrid surgery versus anterior cervical discectomy and fusion for multilevel cervical degenerative disc diseases: a meta-analysis. Sci Rep. 2015;5:13454. https:\/\/doi.org\/10.1038\/srep13454.","journal-title":"Sci Rep"},{"issue":"20","key":"5316_CR5","doi-asserted-by":"publisher","first-page":"1418","DOI":"10.1097\/BRS.0000000000002639","volume":"43","author":"Y Xiong","year":"2018","unstructured":"Xiong Y, Xu L, Yu X, Yang Y, Zhao D, Hu Z, et al. Comparison of 6-year follow-up result of hybrid surgery and Anterior Cervical Discectomy and Fusion for the treatment of Contiguous two-segment cervical degenerative disc diseases. Spine (Phila Pa 1976). 2018;43(20):1418\u201325. https:\/\/doi.org\/10.1097\/BRS.0000000000002639.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"6","key":"5316_CR6","doi-asserted-by":"publisher","first-page":"218","DOI":"10.1097\/BSD.0b013e31826994bb","volume":"29","author":"X Ren","year":"2016","unstructured":"Ren X, Chu T, Jiang T, Wang W, Wang J, Li C, et al. Cervical disk replacement combined with Cage Fusion for the treatment of Multilevel Cervical Disk Herniation. Clin Spine Surg. 2016;29(6):218\u201325. https:\/\/doi.org\/10.1097\/BSD.0b013e31826994bb.","journal-title":"Clin Spine Surg"},{"key":"5316_CR7","doi-asserted-by":"publisher","first-page":"1031","DOI":"10.12659\/MSM.892712","volume":"21","author":"B Liu","year":"2015","unstructured":"Liu B, Zeng Z, Hoof TV, Kalala JP, Liu Z, Wu B. Comparison of hybrid constructs with 2-level artificial disc replacement and 2-level anterior cervical discectomy and fusion for surgical reconstruction of the cervical spine: a kinematic study in whole cadavers. Med Sci Monit. 2015;21:1031\u20137. https:\/\/doi.org\/10.12659\/MSM.892712.","journal-title":"Med Sci Monit"},{"issue":"3","key":"5316_CR8","doi-asserted-by":"publisher","first-page":"497","DOI":"10.1093\/neuros\/nyaa459","volume":"88","author":"K Kim","year":"2021","unstructured":"Kim K, Hoffman G, Bae H, Redmond A, Hisey M, Nunley P, et al. Ten-year outcomes of 1- and 2-Level cervical disc Arthroplasty from the Mobi-C investigational device exemption clinical trial. Neurosurgery. 2021;88(3):497\u2013505. https:\/\/doi.org\/10.1093\/neuros\/nyaa459.","journal-title":"Neurosurgery"},{"issue":"11","key":"5316_CR9","doi-asserted-by":"publisher","first-page":"2823","DOI":"10.1007\/s00586-020-06486-5","volume":"29","author":"M Genitiempo","year":"2020","unstructured":"Genitiempo M, Perna A, Santagada DA, Meluzio MC, Proietti L, Bocchi MB, et al. Single-level Bryan cervical disc arthroplasty: evaluation of radiological and clinical outcomes after 18 years of follow-up. Eur Spine J. 2020;29(11):2823\u201330. https:\/\/doi.org\/10.1007\/s00586-020-06486-5.","journal-title":"Eur Spine J"},{"key":"5316_CR10","doi-asserted-by":"publisher","first-page":"e702","DOI":"10.1016\/j.wneu.2019.12.111","volume":"135","author":"H Sang","year":"2020","unstructured":"Sang H, Cui W, Sang D, Guo Z, Liu B. How Center of Rotation Changes and what affects these after cervical arthroplasty: a systematic review and Meta-analysis. World Neurosurg. 2020;135:e702\u20139. https:\/\/doi.org\/10.1016\/j.wneu.2019.12.111.","journal-title":"World Neurosurg"},{"issue":"1","key":"5316_CR11","doi-asserted-by":"publisher","first-page":"149","DOI":"10.1186\/s13018-022-03051-2","volume":"17","author":"C Li","year":"2022","unstructured":"Li C, Yu X, Xiong Y, Yang Y, Wang F, Zhao H. Mid-long-term follow-up of operated level kinematics after single-level artificial cervical disc replacement with Bryan disc. J Orthop Surg Res. 2022;17(1):149. https:\/\/doi.org\/10.1186\/s13018-022-03051-2.","journal-title":"J Orthop Surg Res"},{"issue":"s2","key":"5316_CR12","doi-asserted-by":"publisher","first-page":"S29","DOI":"10.14444\/7088","volume":"14","author":"P Nunley","year":"2020","unstructured":"Nunley P, Frank K, Stone M. Patient selection in cervical disc arthroplasty. Int J Spine Surg. 2020;14(s2):S29\u201335. https:\/\/doi.org\/10.14444\/7088.","journal-title":"Int J Spine Surg"},{"issue":"7","key":"5316_CR13","doi-asserted-by":"publisher","first-page":"748","DOI":"10.1097\/00007632-199207000-00004","volume":"17","author":"B Amevo","year":"1992","unstructured":"Amevo B, Aprill C, Bogduk N. Abnormal instantaneous axes of rotation in patients with neck pain. Spine (Phila Pa 1976). 1992;17(7):748\u201356. https:\/\/doi.org\/10.1097\/00007632-199207000-00004.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"1","key":"5316_CR14","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1016\/0268-0033(91)90039-S","volume":"6","author":"B Amevo","year":"1991","unstructured":"Amevo B, Macintosh JE, Worth D, Bogduk N. Instantaneous axes of rotation of the typical cervical motion segments: I. an empirical study of technical errors. Clin Biomech (Bristol Avon). 1991;6(1):31\u20137. https:\/\/doi.org\/10.1016\/0268-0033(91)90039-S.","journal-title":"Clin Biomech (Bristol Avon)"},{"issue":"11","key":"5316_CR15","doi-asserted-by":"publisher","first-page":"2307","DOI":"10.1007\/s00586-014-3431-7","volume":"23","author":"B Liu","year":"2014","unstructured":"Liu B, Liu Z, VanHoof T, Kalala J, Zeng Z, Lin X. Kinematic study of the relation between the instantaneous center of rotation and degenerative changes in the cervical intervertebral disc. Eur Spine J. 2014;23(11):2307\u201313. https:\/\/doi.org\/10.1007\/s00586-014-3431-7.","journal-title":"Eur Spine J"},{"issue":"3","key":"5316_CR16","doi-asserted-by":"publisher","first-page":"358","DOI":"10.1007\/s00586-008-0820-9","volume":"18","author":"J Walraevens","year":"2009","unstructured":"Walraevens J, Liu B, Meersschaert J, Demaerel P, Delye H, Depreitere B, et al. Qualitative and quantitative assessment of degeneration of cervical intervertebral discs and facet joints. Eur Spine J. 2009;18(3):358\u201369. https:\/\/doi.org\/10.1007\/s00586-008-0820-9.","journal-title":"Eur Spine J"},{"key":"5316_CR17","doi-asserted-by":"publisher","first-page":"e678","DOI":"10.1016\/j.wneu.2019.01.152","volume":"125","author":"Y Xiong","year":"2019","unstructured":"Xiong Y, Xu L, Bi LY, Yang JZ, Wang FX, Qu Y, et al. Dynamic Fusion process in the Anterior Cervical Discectomy and Fusion with Self-Locking stand-alone cages. World Neurosurg. 2019;125:e678\u201387. https:\/\/doi.org\/10.1016\/j.wneu.2019.01.152.","journal-title":"World Neurosurg"},{"issue":"7","key":"5316_CR18","doi-asserted-by":"publisher","first-page":"1369","DOI":"10.1016\/j.jbiomech.2013.01.018","volume":"46","author":"BP Kelly","year":"2013","unstructured":"Kelly BP, Zufelt NA, Sander EJ, DiAngelo DJ. The influence of fixed sagittal plane centers of rotation on motion segment mechanics and range of motion in the cervical spine. J Biomech. 2013;46(7):1369\u201375. https:\/\/doi.org\/10.1016\/j.jbiomech.2013.01.018.","journal-title":"J Biomech"},{"issue":"4","key":"5316_CR19","doi-asserted-by":"publisher","first-page":"670","DOI":"10.1016\/j.jbiomech.2012.11.055","volume":"46","author":"E Baillargeon","year":"2013","unstructured":"Baillargeon E, Anderst WJ. Sensitivity, reliability and accuracy of the instant center of rotation calculation in the cervical spine during in vivo dynamic flexion-extension. J Biomech. 2013;46(4):670\u20136. https:\/\/doi.org\/10.1016\/j.jbiomech.2012.11.055.","journal-title":"J Biomech"},{"issue":"9","key":"5316_CR20","doi-asserted-by":"publisher","first-page":"633","DOI":"10.1016\/s0268-0033(00)00034-6","volume":"15","author":"N Bogduk","year":"2000","unstructured":"Bogduk N, Mercer S. Biomechanics of the cervical spine. I: normal kinematics. Clin Biomech (Bristol Avon). 2000;15(9):633\u201348. https:\/\/doi.org\/10.1016\/s0268-0033(00)00034-6.","journal-title":"Clin Biomech (Bristol Avon)"},{"issue":"4","key":"5316_CR21","doi-asserted-by":"publisher","first-page":"851","DOI":"10.1007\/s00264-017-3745-2","volume":"42","author":"V Pointillart","year":"2018","unstructured":"Pointillart V, Castelain JE, Coudert P, Cawley DT, Gille O, Vital JM. Outcomes of the Bryan cervical disc replacement: fifteen year follow-up. Int Orthop. 2018;42(4):851\u20137. https:\/\/doi.org\/10.1007\/s00264-017-3745-2.","journal-title":"Int Orthop"},{"issue":"2","key":"5316_CR22","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1097\/BSD.0b013e3181991413","volume":"23","author":"JW Powell","year":"2010","unstructured":"Powell JW, Sasso RC, Metcalf NH, Anderson PA, Hipp JA. Quality of spinal motion with cervical disk arthroplasty: computer-aided radiographic analysis. J Spinal Disord Tech. 2010;23(2):89\u201395. https:\/\/doi.org\/10.1097\/BSD.0b013e3181991413.","journal-title":"J Spinal Disord Tech"},{"issue":"6","key":"5316_CR23","doi-asserted-by":"publisher","first-page":"E6","DOI":"10.3171\/2010.3.FOCUS1058","volume":"28","author":"BC Lazaro","year":"2010","unstructured":"Lazaro BC, Yucesoy K, Yuksel KZ, Kowalczyk I, Rabin D, Fink M, et al. Effect of arthroplasty design on cervical spine kinematics: analysis of the Bryan Disc, ProDisc-C, and synergy disc. Neurosurg Focus. 2010;28(6):E6. https:\/\/doi.org\/10.3171\/2010.3.FOCUS1058.","journal-title":"Neurosurg Focus"},{"issue":"6","key":"5316_CR24","doi-asserted-by":"publisher","first-page":"628","DOI":"10.1016\/j.spinee.2013.02.046","volume":"13","author":"WH Ryu","year":"2013","unstructured":"Ryu WH, Kowalczyk I, Duggal N. Long-term kinematic analysis of cervical spine after single-level implantation of Bryan cervical disc prosthesis. Spine J. 2013;13(6):628\u201334. https:\/\/doi.org\/10.1016\/j.spinee.2013.02.046.","journal-title":"Spine J"},{"issue":"4","key":"5316_CR25","doi-asserted-by":"publisher","first-page":"747","DOI":"10.1007\/s00586-012-2583-6","volume":"22","author":"H Koller","year":"2013","unstructured":"Koller H, Meier O, Zenner J, Mayer M, Hitzl W. In vivo analysis of cervical kinematics after implantation of a minimally constrained cervical artificial disc replacement. Eur Spine J. 2013;22(4):747\u201358. https:\/\/doi.org\/10.1007\/s00586-012-2583-6.","journal-title":"Eur Spine J"},{"issue":"11","key":"5316_CR26","doi-asserted-by":"publisher","first-page":"e956","DOI":"10.3928\/01477447-20141023-50","volume":"37","author":"HX Zhang","year":"2014","unstructured":"Zhang HX, Chen Y, Gao P, Shao YD, Hou Y, Cheng L, et al. Clinical and radiographic evaluation of cervical disk replacement: a retrospective study. Orthopedics. 2014;37(11):e956\u201361. https:\/\/doi.org\/10.3928\/01477447-20141023-50.","journal-title":"Orthopedics"},{"issue":"16","key":"5316_CR27","doi-asserted-by":"publisher","first-page":"1556","DOI":"10.1097\/BRS.0b013e3181c6526b","volume":"35","author":"S Yi","year":"2010","unstructured":"Yi S, Kim KN, Yang MS, Yang JW, Kim H, Ha Y, et al. Difference in occurrence of heterotopic ossification according to prosthesis type in the cervical artificial disc replacement. Spine (Phila Pa 1976). 2010;35(16):1556\u201361. https:\/\/doi.org\/10.1097\/BRS.0b013e3181c6526b.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"2","key":"5316_CR28","doi-asserted-by":"publisher","first-page":"123","DOI":"10.3171\/2018.1.SPINE171018","volume":"29","author":"DC Kieser","year":"2018","unstructured":"Kieser DC, Cawley DT, Fujishiro T, Mazas S, Boissi\u00e8re L, Obeid I, et al. Risk factors for anterior bone loss in cervical disc arthroplasty. J Neurosurg Spine. 2018;29(2):123\u20139. https:\/\/doi.org\/10.3171\/2018.1.SPINE171018.","journal-title":"J Neurosurg Spine"},{"issue":"3","key":"5316_CR29","doi-asserted-by":"publisher","first-page":"1265","DOI":"10.1007\/s00586-023-08047-y","volume":"33","author":"Y Ma","year":"2024","unstructured":"Ma Y, Yu X, Li C, Xiong Y, Zhao H, Yang Y, et al. Changes in the centre of rotation and the anterior bone loss of the vertebral body in Mobi-C artificial disc replacement segments after cervical hybrid surgery: a retrospective study. Eur Spine J. 2024;33(3):1265\u201374. https:\/\/doi.org\/10.1007\/s00586-023-08047-y.","journal-title":"Eur Spine J"},{"issue":"4","key":"5316_CR30","doi-asserted-by":"publisher","first-page":"314","DOI":"10.1097\/00024720-200308000-00002","volume":"16","author":"DJ DiAngelo","year":"2003","unstructured":"DiAngelo DJ, Roberston JT, Metcalf NH, McVay BJ, Davis RC. Biomechanical testing of an artificial cervical joint and an anterior cervical plate. J Spinal Disord Tech. 2003;16(4):314\u201323. https:\/\/doi.org\/10.1097\/00024720-200308000-00002.","journal-title":"J Spinal Disord Tech"},{"issue":"6","key":"5316_CR31","doi-asserted-by":"publisher","first-page":"630","DOI":"10.3171\/2011.8.SPINE11273","volume":"15","author":"I Kowalczyk","year":"2011","unstructured":"Kowalczyk I, Lazaro BC, Fink M, Rabin D, Duggal N. Analysis of in vivo kinematics of 3 different cervical devices: Bryan disc, ProDisc-C, and Prestige LP disc. J Neurosurg Spine. 2011;15(6):630\u20135. https:\/\/doi.org\/10.3171\/2011.8.SPINE11273.","journal-title":"J Neurosurg Spine"},{"key":"5316_CR32","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0000000000000634","author":"X Rong","year":"2014","unstructured":"Rong X, Gong Q, Liu H, Hong Y, Lou J, Wu W, et al. The effect of deviated center of rotation on flexion-extension range of motion after single-level cervical arthroplasty: an in vivo study. Spine (Phila Pa 1976). 2014. https:\/\/doi.org\/10.1097\/BRS.0000000000000634. 39(26 Spec No.):B12-8.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"1","key":"5316_CR33","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1016\/0268-0033(88)90124-6","volume":"3","author":"L Penning","year":"1988","unstructured":"Penning L. Differences in anatomy, motion, development and aging of the upper and lower cervical disk segments. Clin Biomech (Bristol Avon). 1988;3(1):37\u201347. https:\/\/doi.org\/10.1016\/0268-0033(88)90124-6.","journal-title":"Clin Biomech (Bristol Avon)"},{"key":"5316_CR34","doi-asserted-by":"publisher","unstructured":"Lee SW, Draper ER, Hughes SP. Instantaneous center of rotation and instability of the cervical spine. A clinical study. Spine (Phila Pa 1976). 1997; 22(6):641-7; discussion 647-8. https:\/\/doi.org\/10.1097\/00007632-199703150-00013","DOI":"10.1097\/00007632-199703150-00013"},{"key":"5316_CR35","doi-asserted-by":"publisher","unstructured":"Ma Y, Yu X, Xu L et al. Changes in the Centers of Rotation in Different Prosthetic Segments Following Continuous Two-Level Cervical Disc Replacement: A Retrospective Study. World Neurosurg. 2024; 15:S1878-8750(24)01658-9. https:\/\/doi.org\/10.1016\/j.wneu.2024.09.110","DOI":"10.1016\/j.wneu.2024.09.110"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-024-05316-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13018-024-05316-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-024-05316-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,12,19]],"date-time":"2024-12-19T04:08:54Z","timestamp":1734581334000},"score":1,"resource":{"primary":{"URL":"https:\/\/josr-online.biomedcentral.com\/articles\/10.1186\/s13018-024-05316-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,19]]},"references-count":35,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["5316"],"URL":"https:\/\/doi.org\/10.1186\/s13018-024-05316-4","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-5077353\/v1","asserted-by":"object"}]},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,12,19]]},"assertion":[{"value":"12 September 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 November 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 December 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"857"}}