{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T12:15:34Z","timestamp":1788437734474,"version":"build-2803163510"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,1,18]],"date-time":"2025-01-18T00:00:00Z","timestamp":1737158400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,1,18]],"date-time":"2025-01-18T00:00:00Z","timestamp":1737158400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Universit\u00e4tsklinikum Hamburg-Eppendorf (UKE)"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>In atlantoaxial instabilities, posterior C1\/C2 fusion using lateral mass screws (LMS) or pedicle screws (PS) in a mono- or bicortical position in the atlas is a typical treatment. The bone microstructure and positioning of the screw trajectories appear to be of significant relevance for stability.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>The aim of this study was a comparative analysis of the mechanical durability of screw fixation concerning microstructural characteristics of the trajectories of LMS and PS in mono- and bicortical position.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      Human C1 from geriatric body donors (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200928; 50% female, age 80.8\u2009\u00b1\u200913.9 years) were collected and characterized based on their bone microstructure. Additionally, the mechanical stability of LMS and PS fixation in mono- and bicortical positioning was tested by mechanical loading. High-resolution quantitative computed tomography was used to analyze the bone microstructure of cylinders corresponding to the trajectories of PS and LMS in mono- and bicortical locations in each C1. After instrumentation with both screw types and types of fixation, the mechanical stability was tested by increased cyclic loading in cranio-caudal direction.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Trajectories of PS presented with more bone volume and a higher contact length to cortical bone. Simultaneously, a higher number of cycles and a higher maximum force was needed to loosen PS compared to LMS, while the loose by torque at the experiment end was still greater in PS. Differences between mono- and bicortical positioning of PS and LMS have only been observed in the initial stiffness of screws. When comparing microstructural and mechanical properties, the cortical contact length and bone volume in screw trajectories were strongest associated with a high loose and cycle count.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>This study suggests that mono- and bicortical positioning of PS is similarly efficient in creating a stable basis for screw fixation in the atlas. While PS are superior to LMS, the contact with cortical bone is of major relevance for a stable foundation.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s13018-025-05472-1","type":"journal-article","created":{"date-parts":[[2025,1,17]],"date-time":"2025-01-17T23:43:16Z","timestamp":1737157396000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Superior biomechanical stability of pedicle screws compared to lateral mass screws: recommendations for bicortical positioning and enhancing bone contact in geriatric C1 vertebrae"],"prefix":"10.1186","volume":"20","author":[{"given":"Leon-Gordian","family":"Leonhardt","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Leonie","family":"R\u00f6rup","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anna Lena","family":"Kammal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Hahn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marc","family":"Dreimann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Benjamin","family":"Ondruschka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Felix Nikolai","family":"von Brackel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tim","family":"Rolvien","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lennart","family":"Viezens","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Simon","family":"von Kroge","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,1,18]]},"reference":[{"key":"5472_CR1","doi-asserted-by":"publisher","first-page":"573","DOI":"10.2214\/ajr.178.3.1780573","volume":"178","author":"FM Lomoschitz","year":"2002","unstructured":"Lomoschitz FM, Blackmore CC, Mirza SK, Mann FA. Cervical spine injuries in patients 65 years old and older: epidemiologic analysis regarding the effects of age and injury mechanism on distribution, type, and stability of injuries. AJR Am J Roentgenol. 2002;178:573\u20137.","journal-title":"AJR Am J Roentgenol"},{"key":"5472_CR2","doi-asserted-by":"publisher","first-page":"1102","DOI":"10.1093\/ageing\/afaa088","volume":"49","author":"A Tarawneh","year":"2020","unstructured":"Tarawneh A, Taqvi S, Salem K, Sahota O. Cervical spine fragility fractures in older people: 5-year experience at a regional spine centre. Age Ageing. 2020;49:1102\u20134.","journal-title":"Age Ageing"},{"key":"5472_CR3","doi-asserted-by":"publisher","first-page":"38","DOI":"10.1016\/0020-1383(92)90123-A","volume":"23","author":"MD Ryan","year":"1992","unstructured":"Ryan MD, Henderson JJ. The epidemiology of fractures and fracture-dislocations of the cervical spine. Injury. 1992;23:38\u201340.","journal-title":"Injury"},{"key":"5472_CR4","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3171\/2009.7.SPINE08589","volume":"12","author":"AT Dailey","year":"2010","unstructured":"Dailey AT, Hart D, Finn MA, Schmidt MH, Apfelbaum RI. Anterior fixation of odontoid fractures in an elderly population. J Neurosurg Spine. 2010;12:1\u20138.","journal-title":"J Neurosurg Spine"},{"key":"5472_CR5","doi-asserted-by":"publisher","first-page":"449","DOI":"10.2106\/JBJS.O.00468","volume":"98","author":"AM Pearson","year":"2016","unstructured":"Pearson AM, Martin BI, Lindsey M, Mirza SK. C2 vertebral fractures in the Medicare Population: incidence, outcomes, and costs. J Bone Joint Surg Am. 2016;98:449\u201356.","journal-title":"J Bone Joint Surg Am"},{"key":"5472_CR6","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1016\/j.clineuro.2014.09.006","volume":"126","author":"K Vasudevan","year":"2014","unstructured":"Vasudevan K, Grossberg JA, Spader HS, Torabi R, Oyelese AA. Age increases the risk of immediate postoperative dysphagia and pneumonia after odontoid screw fixation. Clin Neurol Neurosurg. 2014;126:185\u20139.","journal-title":"Clin Neurol Neurosurg"},{"key":"5472_CR7","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1097\/00006123-199808000-00056","volume":"43","author":"CA Dickman","year":"1998","unstructured":"Dickman CA, Sonntag VK. Posterior C1-C2 transarticular screw fixation for atlantoaxial arthrodesis. Neurosurgery. 1998;43:275\u201380. discussion 280\u2009\u2013\u2009271.","journal-title":"Neurosurgery"},{"key":"5472_CR8","doi-asserted-by":"publisher","first-page":"2467","DOI":"10.1097\/00007632-200111150-00014","volume":"26","author":"J Harms","year":"2001","unstructured":"Harms J, Melcher RP. Posterior C1-C2 fusion with polyaxial screw and rod fixation. Spine (Phila Pa 1976). 2001;26:2467\u201371.","journal-title":"Spine (Phila Pa 1976)"},{"key":"5472_CR9","doi-asserted-by":"publisher","first-page":"337","DOI":"10.3171\/2009.10.SPINE08541","volume":"12","author":"JA Thomas","year":"2010","unstructured":"Thomas JA, Tredway T, Fessler RG, Sandhu FA. An alternate method for placement of C-1 screws. J Neurosurg Spine. 2010;12:337\u201341.","journal-title":"J Neurosurg Spine"},{"key":"5472_CR10","first-page":"426","volume":"50","author":"DK Resnick","year":"2002","unstructured":"Resnick DK, Benzel EC. C1-C2 pedicle screw fixation with rigid cantilever beam construct: case report and technical note. Neurosurgery. 2002;50:426\u20138.","journal-title":"Neurosurgery"},{"key":"5472_CR11","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1097\/BRS.0b013e318193a21b","volume":"34","author":"XY Ma","year":"2009","unstructured":"Ma XY, Yin QS, Wu ZH, Xia H, Liu JF, Xiang M, Zhao WD, Zhong SZ. C1 pedicle screws versus C1 lateral mass screws: comparisons of pullout strengths and biomechanical stabilities. Spine (Phila Pa 1976). 2009;34:371\u20137.","journal-title":"Spine (Phila Pa 1976)"},{"key":"5472_CR12","doi-asserted-by":"publisher","first-page":"724","DOI":"10.1007\/s00586-013-3143-4","volume":"23","author":"F Fensky","year":"2014","unstructured":"Fensky F, Kueny RA, Sellenschloh K, Puschel K, Morlock MM, Rueger JM, Lehmann W, Huber G. Hansen-Algenstaedt, Biomechanical advantage of C1 pedicle screws over C1 lateral mass screws: a cadaveric study. Eur Spine J. 2014;23:724\u201331.","journal-title":"Eur Spine J"},{"key":"5472_CR13","doi-asserted-by":"publisher","first-page":"505","DOI":"10.1097\/BSD.0b013e318031af8b","volume":"20","author":"JC Eck","year":"2007","unstructured":"Eck JC, Walker MP, Currier BL, Chen Q, Yaszemski MJ, An KN. Biomechanical comparison of unicortical versus bicortical C1 lateral mass screw fixation. J Spinal Disord Tech. 2007;20:505\u20138.","journal-title":"J Spinal Disord Tech"},{"key":"5472_CR14","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1007\/s00586-009-1181-8","volume":"19","author":"M Gebauer","year":"2010","unstructured":"Gebauer M, Barvencik F, Briem D, Kolb JP, Seitz S, Rueger JM, Puschel K, Amling M. Evaluation of anatomic landmarks and safe zones for screw placement in the atlas via the posterior arch. Eur Spine J. 2010;19:85\u201390.","journal-title":"Eur Spine J"},{"key":"5472_CR15","doi-asserted-by":"publisher","first-page":"2497","DOI":"10.1007\/s00590-022-03465-y","volume":"33","author":"A Cavalcanti Kussmaul","year":"2023","unstructured":"Cavalcanti Kussmaul A, Kuhlein T, Greiner A, Walter S, Becker CA, Kistler M, Rubenbauer B, Andress S, Bocker W, Bruder J. Improving stability of atlantoaxial fusion: a biomechanical study. Eur J Orthop Surg Traumatol. 2023;33:2497\u2013503.","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"5472_CR16","doi-asserted-by":"publisher","first-page":"844","DOI":"10.1097\/01.brs.0000259833.02179.c0","volume":"32","author":"DM Christensen","year":"2007","unstructured":"Christensen DM, Eastlack RK, Lynch JJ, Yaszemski MJ, Currier BL. C1 anatomy and dimensions relative to lateral mass screw placement. Spine (Phila Pa 1976). 2007;32:844\u20138.","journal-title":"Spine (Phila Pa 1976)"},{"key":"5472_CR17","doi-asserted-by":"publisher","first-page":"1519","DOI":"10.1097\/01.brs.0000168546.17788.49","volume":"30","author":"XY Ma","year":"2005","unstructured":"Ma XY, Yin QS, Wu ZH, Xia H, Liu JF, Zhong SZ. Anatomic considerations for the pedicle screw placement in the first cervical vertebra. Spine (Phila Pa 1976). 2005;30:1519\u201323.","journal-title":"Spine (Phila Pa 1976)"},{"key":"5472_CR18","doi-asserted-by":"publisher","first-page":"888","DOI":"10.1097\/01.BRS.0000058719.48596.CC","volume":"28","author":"MH Tan","year":"2003","unstructured":"Tan MH, Wang H, Wang Y, Zhang G, Yi P, Li Z, Wei H, Yang F. Morphometric evaluation of screw fixation in atlas via posterior arch and lateral mass. Spine (Phila Pa 1976). 2003;28:888\u201395.","journal-title":"Spine (Phila Pa 1976)"},{"key":"5472_CR19","doi-asserted-by":"publisher","first-page":"457","DOI":"10.1302\/0301-620X.86B3.14323","volume":"86","author":"B Sand\u00e9n","year":"2004","unstructured":"Sand\u00e9n B, Olerud C, Petr\u00e9n-Mallmin M, Johansson C, Larsson S. The significance of radiolucent zones surrounding pedicle screws. Definition of screw loosening in spinal instrumentation. J Bone Joint Sur Br. 2004;86:457\u201361.","journal-title":"J Bone Joint Sur Br"},{"key":"5472_CR20","doi-asserted-by":"publisher","first-page":"2891","DOI":"10.1007\/s00586-017-5091-x","volume":"26","author":"L Weiser","year":"2017","unstructured":"Weiser L, Huber G, Sellenschloh K, Viezens L, Puschel K, Morlock MM, Lehmann W. Insufficient stability of pedicle screws in osteoporotic vertebrae: biomechanical correlation of bone mineral density and pedicle screw fixation strength. Eur Spine J. 2017;26:2891\u20137.","journal-title":"Eur Spine J"},{"key":"5472_CR21","first-page":"100228","volume":"14","author":"JL Baisden","year":"2023","unstructured":"Baisden JL, Varghese V, Banerjee A, Yoganandan N. Regional variations in C1-C2 bone density on quantitated computed tomography and clinical implications. N Am Spine Soc J. 2023;14:100228.","journal-title":"N Am Spine Soc J"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-025-05472-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13018-025-05472-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-025-05472-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,1,17]],"date-time":"2025-01-17T23:43:20Z","timestamp":1737157400000},"score":1,"resource":{"primary":{"URL":"https:\/\/josr-online.biomedcentral.com\/articles\/10.1186\/s13018-025-05472-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1,18]]},"references-count":21,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["5472"],"URL":"https:\/\/doi.org\/10.1186\/s13018-025-05472-1","relation":{},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,1,18]]},"assertion":[{"value":"25 November 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 January 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 January 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was reported to the local ethics committee (2022-300148-WF) and complied with the Declaration of Helsinki.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"63"}}