{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,17]],"date-time":"2026-03-17T17:40:17Z","timestamp":1773769217475,"version":"3.50.1"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,3,25]],"date-time":"2025-03-25T00:00:00Z","timestamp":1742860800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2025,3,25]],"date-time":"2025-03-25T00:00:00Z","timestamp":1742860800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"DOI":"10.1186\/s13018-025-05686-3","type":"journal-article","created":{"date-parts":[[2025,3,25]],"date-time":"2025-03-25T03:22:45Z","timestamp":1742872965000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["The effect of screw hole inserts for the unused screw holes on the strength of a plate"],"prefix":"10.1186","volume":"20","author":[{"given":"Onur","family":"Basci","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4201-8239","authenticated-orcid":false,"given":"Selahaddin","family":"Aydemir","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ahmet Emrah","family":"Acan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Onur","family":"Gursan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bora","family":"Uzun","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mehmet","family":"Erduran","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,3,25]]},"reference":[{"issue":"10","key":"5686_CR1","doi-asserted-by":"publisher","first-page":"1049","DOI":"10.1016\/j.clinbiomech.2007.08.004","volume":"22","author":"DL Miller","year":"2007","unstructured":"Miller DL, Goswami T. A review of locking compression plate biomechanics and their advantages as internal fixators in fracture healing. Clin Biomech (Bristol, Avon). 2007;22(10):1049\u201362. https:\/\/doi.org\/10.1016\/j.clinbiomech.2007.08.004.","journal-title":"Clin Biomech (Bristol, Avon)"},{"issue":"Suppl 1","key":"5686_CR2","doi-asserted-by":"publisher","first-page":"S2","DOI":"10.1016\/S0020-1383(18)30294-8","volume":"49","author":"P Augat","year":"2018","unstructured":"Augat P, von R\u00fcden C. Evolution of fracture treatment with bone plates. Injury. 2018;49(Suppl 1):S2\u20137. https:\/\/doi.org\/10.1016\/S0020-1383(18)30294-8.","journal-title":"Injury"},{"issue":"2","key":"5686_CR3","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1097\/BOT.0b013e3181dc56b1","volume":"25","author":"J Bellapianta","year":"2011","unstructured":"Bellapianta J, Dow K, Pallotta NA, Hospodar PP, Uhl RL, Ledet EH. Threaded screw head inserts improve locking plate biomechanical properties. J Orthop Trauma. 2011;25(2):65\u201371. https:\/\/doi.org\/10.1097\/BOT.0b013e3181dc56b1.","journal-title":"J Orthop Trauma"},{"issue":"7","key":"5686_CR4","doi-asserted-by":"publisher","first-page":"479","DOI":"10.1097\/BOT.0b013e31817996d6","volume":"22","author":"EJ Strauss","year":"2008","unstructured":"Strauss EJ, Schwarzkopf R, Kummer F, Egol KA. The current status of locked plating: the good, the bad, and the ugly. J Orthop Trauma. 2008;22(7):479\u201386. https:\/\/doi.org\/10.1097\/BOT.0b013e31817996d6.","journal-title":"J Orthop Trauma"},{"issue":"Suppl 4","key":"5686_CR5","doi-asserted-by":"publisher","first-page":"189","DOI":"10.2106\/JBJS.F.00703","volume":"88","author":"EN Kubiak","year":"2006","unstructured":"Kubiak EN, Fulkerson E, Strauss E, Egol KA. The evolution of locked plates. J Bone Jt Surg. 2006;88(Suppl 4):189\u2013200. https:\/\/doi.org\/10.2106\/JBJS.F.00703.","journal-title":"J Bone Jt Surg"},{"issue":"1","key":"5686_CR6","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1177\/1460408615591625","volume":"18","author":"R Nandra","year":"2016","unstructured":"Nandra R, Grover L, Porter K. Fracture non-union epidemiology and treatment. Trauma. 2016;18(1):3\u201311. https:\/\/doi.org\/10.1177\/1460408615591625.","journal-title":"Trauma"},{"issue":"4","key":"5686_CR7","doi-asserted-by":"publisher","first-page":"258","DOI":"10.1016\/j.cuor.2007.06.004","volume":"21","author":"V Perumal","year":"2007","unstructured":"Perumal V, Roberts CS. (ii) Factors contributing to non-union of fractures. Curr Orthop. 2007;21(4):258\u201361.","journal-title":"Curr Orthop"},{"issue":"4","key":"5686_CR8","doi-asserted-by":"publisher","first-page":"830","DOI":"10.1097\/01.ta.0000195462.53525.0c","volume":"60","author":"E Fulkerson","year":"2006","unstructured":"Fulkerson E, Egol KA, Kubiak EN, Liporace F, Kummer FJ, Koval KJ. Fixation of diaphyseal fractures with a segmental defect: a biomechanical comparison of locked and conventional plating techniques. J Trauma. 2006;60(4):830\u20135. https:\/\/doi.org\/10.1097\/01.ta.0000195462.53525.0c.","journal-title":"J Trauma"},{"issue":"9","key":"5686_CR9","doi-asserted-by":"publisher","first-page":"597","DOI":"10.1097\/01.bot.0000174033.30054.5f","volume":"19","author":"MJ Gardner","year":"2005","unstructured":"Gardner MJ, Brophy RH, Campbell D, Mahajan A, Wright TM, Helfet DL, Lorich DG. The mechanical behavior of locking compression plates compared with dynamic compression plates in a cadaver radius model. J Orthop Trauma. 2005;19(9):597\u2013603. https:\/\/doi.org\/10.1097\/01.bot.0000174033.30054.5f.","journal-title":"J Orthop Trauma"},{"issue":"2","key":"5686_CR10","doi-asserted-by":"publisher","first-page":"241","DOI":"10.1302\/0301-620X.94B2.27440","volume":"94","author":"R Firoozabadi","year":"2012","unstructured":"Firoozabadi R, McDonald E, Nguyen TQ, Buckley JM, Kandemir U. Does plugging unused combination screw holes improve the fatigue life of fixation with locking plates in comminuted supracondylar fractures of the femur? J Bone Jt Surg Br. 2012;94(2):241\u20138.","journal-title":"J Bone Jt Surg Br"},{"key":"5686_CR11","first-page":"293","volume":"32","author":"L Grau","year":"2018","unstructured":"Grau L, Collon K, Alhandi A, Kaimrajh D, Varon M, Latta L, Vilella F. Filling open screw holes in the area of metaphyseal comminution does not affect fatigue life of the synthes variable angle distal femoral locking plate in the AO\/OTA 33\u2013A3 fracture model. Surg Technol Int. 2018;32:293\u20137.","journal-title":"Surg Technol Int"},{"issue":"8","key":"5686_CR12","doi-asserted-by":"publisher","first-page":"488","DOI":"10.1097\/00005131-200409000-00003","volume":"18","author":"KA Egol","year":"2004","unstructured":"Egol KA, Kubiak EN, Fulkerson E, Kummer FJ, Koval KJ. Biomechanics of locked plates and screws. J Orthop Trauma. 2004;18(8):488\u201393. https:\/\/doi.org\/10.1097\/00005131-200409000-00003.","journal-title":"J Orthop Trauma"},{"issue":"Suppl 2","key":"5686_CR13","doi-asserted-by":"publisher","first-page":"B31","DOI":"10.1016\/j.injury.2003.09.023","volume":"34","author":"M Wagner","year":"2003","unstructured":"Wagner M. General principles for the clinical use of the LCP. Injury. 2003;34(Suppl 2):B31\u201342. https:\/\/doi.org\/10.1016\/j.injury.2003.09.023.","journal-title":"Injury"},{"issue":"8","key":"5686_CR14","doi-asserted-by":"publisher","first-page":"571","DOI":"10.1097\/00005131-200409000-00016","volume":"18","author":"C Sommer","year":"2004","unstructured":"Sommer C, Babst R, M\u00fcller M, Hanson B. Locking compression plate loosening and plate breakage: a report of four cases. J Orthop Trauma. 2004;18(8):571\u20137. https:\/\/doi.org\/10.1097\/00005131-200409000-00016.","journal-title":"J Orthop Trauma"},{"issue":"5","key":"5686_CR15","doi-asserted-by":"publisher","first-page":"907","DOI":"10.1016\/j.jhsa.2009.01.004","volume":"34","author":"K Yukata","year":"2009","unstructured":"Yukata K, Doi K, Hattori Y, Sakamoto S. Early breakage of a titanium volar locking plate for fixation of a distal radius fracture: case report. J Hand Surg. 2009;34(5):907\u20139. https:\/\/doi.org\/10.1016\/j.jhsa.2009.01.004.","journal-title":"J Hand Surg"},{"issue":"3","key":"5686_CR16","doi-asserted-by":"publisher","first-page":"1039","DOI":"10.1007\/s11999-012-2664-1","volume":"471","author":"M Tompkins","year":"2013","unstructured":"Tompkins M, Paller DJ, Moore DC, Crisco JJ, Terek RM. Locking buttons increase fatigue life of locking plates in a segmental bone defect model. Clin Orthop Relat Res. 2013;471(3):1039\u201344. https:\/\/doi.org\/10.1007\/s11999-012-2664-1.","journal-title":"Clin Orthop Relat Res"},{"issue":"1","key":"5686_CR17","doi-asserted-by":"publisher","first-page":"104","DOI":"10.1186\/s12917-023-03660-x","volume":"19","author":"J Viitanen","year":"2023","unstructured":"Viitanen J, Quinn R, Allen M, Broeckx BJG, Bartkowiak T, Haimel G. Do locking plugs improve implant strength? Biomechanical comparison of polyaxial locking constructs with and without locking plugs in a fracture gap model. BMC Vet Res. 2023;19(1):104. https:\/\/doi.org\/10.1186\/s12917-023-03660-x.","journal-title":"BMC Vet Res"},{"key":"5686_CR18","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1097\/00003086-199111000-00010","volume":"272","author":"W Ramotowski","year":"1991","unstructured":"Ramotowski W, Granowski R. Zespol. An original method of stable osteosynthesis. Clin Orthop Relat Res. 1991;272:67\u201375.","journal-title":"Clin Orthop Relat Res"},{"issue":"1","key":"5686_CR19","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1016\/j.jor.2013.01.001.PMID:24403745;PMCID:PMC3768240","volume":"10","author":"M Nassiri","year":"2013","unstructured":"Nassiri M, Macdonald B, O\u2019Byrne JM. Computational modelling of long bone fractures fixed with locking plates: How can the risk of implant failure be reduced? J Orthop. 2013;10(1):29\u201337. https:\/\/doi.org\/10.1016\/j.jor.2013.01.001.PMID:24403745;PMCID:PMC3768240.","journal-title":"J Orthop"},{"issue":"Suppl 2","key":"5686_CR20","doi-asserted-by":"publisher","first-page":"B11","DOI":"10.1016\/j.injury.2003.09.021","volume":"34","author":"K Stoffel","year":"2003","unstructured":"Stoffel K, Dieter U, Stachowiak G, G\u00e4chter A, Kuster MS. Biomechanical testing of the LCP: How can stability in locked internal fixators be controlled? Injury. 2003;34(Suppl 2):B11\u20139.","journal-title":"Injury"},{"issue":"1","key":"5686_CR21","doi-asserted-by":"publisher","first-page":"19","DOI":"10.3928\/01477447-20101123-13","volume":"34","author":"JK Eichinger","year":"2011","unstructured":"Eichinger JK, Herzog JP, Arrington ED. Analysis of the mechanical properties of locking plates with and without screw hole inserts. Orthopedics. 2011;34(1):19.","journal-title":"Orthopedics"},{"key":"5686_CR22","doi-asserted-by":"publisher","first-page":"105645","DOI":"10.1016\/j.jmbbm.2022.105645","volume":"138","author":"NZ Zhang","year":"2023","unstructured":"Zhang NZ, Liu BL, Luan YC, Zhang M, Cheng CK. Failure analysis of a locking compression plate with asymmetric holes and polyaxial screws. J Mech Behav Biomed Mater. 2023;138:105645. https:\/\/doi.org\/10.1016\/j.jmbbm.2022.105645.","journal-title":"J Mech Behav Biomed Mater"},{"issue":"10","key":"5686_CR23","doi-asserted-by":"publisher","first-page":"1358","DOI":"10.1016\/j.injury.2013.06.013","volume":"44","author":"J Hebert-Davies","year":"2013","unstructured":"Hebert-Davies J, Laflamme GY, Rouleau D, Canet F, Sandman E, Li A, Petit Y. A biomechanical study comparing polyaxial locking screw mechanisms. Injury. 2013;44(10):1358\u201362. https:\/\/doi.org\/10.1016\/j.injury.2013.06.013.","journal-title":"Injury"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-025-05686-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13018-025-05686-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-025-05686-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,26]],"date-time":"2025-03-26T02:29:48Z","timestamp":1742956188000},"score":1,"resource":{"primary":{"URL":"https:\/\/josr-online.biomedcentral.com\/articles\/10.1186\/s13018-025-05686-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,25]]},"references-count":23,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["5686"],"URL":"https:\/\/doi.org\/10.1186\/s13018-025-05686-3","relation":{},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3,25]]},"assertion":[{"value":"20 January 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 March 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 March 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"No human or animal subjects were involved in this biomechanical study. Therefore, ethical approval was not required.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"312"}}