{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T13:50:57Z","timestamp":1790776257125,"version":"4.1.0"},"reference-count":41,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,4,4]],"date-time":"2025-04-04T00:00:00Z","timestamp":1743724800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2025,4,4]],"date-time":"2025-04-04T00:00:00Z","timestamp":1743724800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"DOI":"10.13039\/100008375","name":"University of Basel","doi-asserted-by":"crossref","id":[{"id":"10.13039\/100008375","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"DOI":"10.1186\/s13018-025-05753-9","type":"journal-article","created":{"date-parts":[[2025,4,5]],"date-time":"2025-04-05T01:55:13Z","timestamp":1743818113000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Reducing femoral peri-implant fracture risk through optimized plate length and screw configuration \u2013 a biomechanical study"],"prefix":"10.1186","volume":"20","author":[{"given":"Luise","family":"Puls","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lionel","family":"Llano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ivan","family":"Zderic","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Boyko","family":"Gueorguiev","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karl","family":"Stoffel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,4,4]]},"reference":[{"issue":"8","key":"5753_CR1","doi-asserted-by":"crossref","first-page":"1201","DOI":"10.1016\/j.otsr.2017.08.008","volume":"103","author":"KC Park","year":"2017","unstructured":"Park KC, Lim SJ, Song YS, Hwang KT. Factors affecting peri-implant fracture following locking plate for osteoporotic distal femur fractures. Orthop Traumatol Surg Res. 2017;103(8):1201\u20134.","journal-title":"Orthop Traumatol Surg Res"},{"issue":"5","key":"5753_CR2","doi-asserted-by":"crossref","first-page":"2081","DOI":"10.1007\/s00590-022-03398-6","volume":"33","author":"AP Meyer","year":"2023","unstructured":"Meyer AP, Large TM. Early peri-implant fractures after distal femur fracture locked plating? Eur J Orthop Surg Traumatol. 2023;33(5):2081\u20139.","journal-title":"Eur J Orthop Surg Traumatol"},{"issue":"11","key":"5753_CR3","doi-asserted-by":"crossref","first-page":"2859","DOI":"10.1007\/s00264-023-05939-y","volume":"47","author":"M Poroh","year":"2023","unstructured":"Poroh M, Puha B, Gheorghevici TS, Jemna C, Forna N, Sirbu P, et al. A retrospective analysis of peri-implant fractures: insights from a large volume clinical study. Int Orthop. 2023;47(11):2859\u201368.","journal-title":"Int Orthop"},{"issue":"1","key":"5753_CR4","first-page":"e322","volume":"7","author":"JK Shah","year":"2024","unstructured":"Shah JK, Abwini LZ, Tang A, Yang JI, Keller DM, Menken LG, et al. Comparative outcomes after treatment of peri-implant, periprosthetic, and interprosthetic femur fractures: which factors increase mortality risk? OTA Int. 2024;7(1):e322.","journal-title":"OTA Int"},{"key":"5753_CR5","doi-asserted-by":"crossref","unstructured":"Wulbrand C, Muller F, Fuchtmeier B, Hanke A. Therapy aspects of peri-implant femoral fractures-a retrospective analysis of 64 patients. Eur J Trauma Emerg Surg. 2024.","DOI":"10.1007\/s00068-024-02508-9"},{"issue":"3","key":"5753_CR6","doi-asserted-by":"crossref","first-page":"620","DOI":"10.2106\/JBJS.H.00408","volume":"91","author":"M Bottlang","year":"2009","unstructured":"Bottlang M, Doornink J, Byrd GD, Fitzpatrick DC, Madey SM. A nonlocking end screw can decrease fracture risk caused by locked plating in the osteoporotic diaphysis. J Bone Joint Surg Am. 2009;91(3):620\u20137.","journal-title":"J Bone Joint Surg Am"},{"key":"5753_CR7","doi-asserted-by":"crossref","unstructured":"Bartl. The osteoporosis manual. Springer International Publishing; 2019.","DOI":"10.1007\/978-3-030-00731-7"},{"issue":"2","key":"5753_CR8","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1016\/j.clinbiomech.2008.11.002","volume":"24","author":"DC Fitzpatrick","year":"2009","unstructured":"Fitzpatrick DC, Doornink J, Madey SM, Bottlang M. Relative stability of conventional and locked plating fixation in a model of the osteoporotic femoral diaphysis. Clin Biomech (Bristol Avon). 2009;24(2):203\u20139.","journal-title":"Clin Biomech (Bristol Avon)"},{"issue":"20","key":"5753_CR9","doi-asserted-by":"crossref","first-page":"1765","DOI":"10.2106\/JBJS.18.00024","volume":"100","author":"JD Namm","year":"2018","unstructured":"Namm JD, Morris RP, Speck FL 3rd, Lindsey RW. The impact of eccentric diaphyseal plate and screw placement on the risk of Peri-Implant fracture. J Bone Joint Surg Am. 2018;100(20):1765\u201370.","journal-title":"J Bone Joint Surg Am"},{"issue":"11","key":"5753_CR10","doi-asserted-by":"crossref","first-page":"e431","DOI":"10.1097\/BOT.0000000000000384","volume":"29","author":"JB Peck","year":"2015","unstructured":"Peck JB, Charpentier PM, Flanagan BP, Srivastava AK, Atkinson PJ. Reducing fracture risk adjacent to a plate with an angulated locked end screw. J Orthop Trauma. 2015;29(11):e431\u20136.","journal-title":"J Orthop Trauma"},{"issue":"2","key":"5753_CR11","first-page":"411","volume":"69","author":"J Doornink","year":"2010","unstructured":"Doornink J, Fitzpatrick DC, Boldhaus S, Madey SM, Bottlang M. Effects of hybrid plating with locked and nonlocked screws on the strength of locked plating constructs in the osteoporotic diaphysis. J Trauma. 2010;69(2):411\u20137.","journal-title":"J Trauma"},{"key":"5753_CR12","first-page":"11","volume":"37","author":"A Wynkoop","year":"2017","unstructured":"Wynkoop A, Ndubaku O, Charpentier PM, Peck JB, Walter NE, Atkinson P. Optimizing hybrid plate fixation with a locked, oblique end screw in osteoporotic fractures. Iowa Orthop J. 2017;37:11\u20137.","journal-title":"Iowa Orthop J"},{"issue":"5","key":"5753_CR13","first-page":"E84","volume":"70","author":"E Karadeniz","year":"2011","unstructured":"Karadeniz E, Balcik BC, Demirors H, Tuncay IC. Biomechanical comparison of conventional technique versus oblique screw placement in plate fixation. J Trauma. 2011;70(5):E84\u20137.","journal-title":"J Trauma"},{"issue":"10","key":"5753_CR14","doi-asserted-by":"crossref","first-page":"709","DOI":"10.1097\/BOT.0b013e31818df8cb","volume":"22","author":"RV O\u2019Toole","year":"2008","unstructured":"O\u2019Toole RV, Andersen RC, Vesnovsky O, Alexander M, Topoleski LD, Nascone JW, et al. Are locking screws advantageous with plate fixation of humeral shaft fractures? A Biomechanical analysis of synthetic and cadaveric bone. J Orthop Trauma. 2008;22(10):709\u201315.","journal-title":"J Orthop Trauma"},{"issue":"7","key":"5753_CR15","doi-asserted-by":"crossref","first-page":"589","DOI":"10.1016\/j.clinbiomech.2009.04.008","volume":"24","author":"S Zehnder","year":"2009","unstructured":"Zehnder S, Bledsoe JG, Puryear A. The effects of screw orientation in severely osteoporotic bone: a comparison with locked plating. Clin Biomech (Bristol Avon). 2009;24(7):589\u201394.","journal-title":"Clin Biomech (Bristol Avon)"},{"issue":"6","key":"5753_CR16","doi-asserted-by":"crossref","first-page":"1139","DOI":"10.1097\/01.TA.0000031103.15337.CA","volume":"55","author":"KQ Robert","year":"2003","unstructured":"Robert KQ 3rd, Chandler R, Baratta RV, Thomas KA, Harris MB. The effect of divergent screw placement on the initial strength of plate-to-bone fixation. J Trauma. 2003;55(6):1139\u201344.","journal-title":"J Trauma"},{"issue":"9","key":"5753_CR17","first-page":"1962","volume":"88","author":"MJ Gardner","year":"2006","unstructured":"Gardner MJ, Griffith MH, Demetrakopoulos D, Brophy RH, Grose A, Helfet DL, et al. Hybrid locked plating of osteoporotic fractures of the humerus. J Bone Joint Surg Am. 2006;88(9):1962\u20137.","journal-title":"J Bone Joint Surg Am"},{"issue":"4","key":"5753_CR18","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1097\/BOT.0b013e318220edae","volume":"26","author":"C Davis","year":"2012","unstructured":"Davis C, Stall A, Knutsen E, Whitney A, Becker E, Hsieh AH, et al. Locking plates in osteoporosis: a Biomechanical cadaveric study of diaphyseal humerus fractures. J Orthop Trauma. 2012;26(4):216\u201321.","journal-title":"J Orthop Trauma"},{"issue":"10","key":"5753_CR19","first-page":"e1262","volume":"36","author":"EY Lo","year":"2013","unstructured":"Lo EY, Tseng SS, Christiansen BA, Lee MA, Yoo BJ. Locking versus nonlocking construct in an osteoporotic, segmental fibula defect model. Orthopedics. 2013;36(10):e1262\u20138.","journal-title":"Orthopedics"},{"issue":"8","key":"5753_CR20","doi-asserted-by":"crossref","first-page":"493","DOI":"10.1302\/2046-3758.98.BJR-2019-0318.R1","volume":"9","author":"JWA Fletcher","year":"2020","unstructured":"Fletcher JWA, Zderic I, Gueorguiev B, Richards RG, Gill HS, Whitehouse MR, et al. Stripping torques in human bone can be reliably predicted prior to screw insertion with optimum tightness being found between 70% and 80% of the maximum. Bone Joint Res. 2020;9(8):493\u2013500.","journal-title":"Bone Joint Res"},{"issue":"5","key":"5753_CR21","doi-asserted-by":"crossref","first-page":"e0155612","DOI":"10.1371\/journal.pone.0155612","volume":"11","author":"G Bergmann","year":"2016","unstructured":"Bergmann G, Bender A, Dymke J, Duda G, Damm P. Standardized loads acting in hip implants. PLoS ONE. 2016;11(5):e0155612.","journal-title":"PLoS ONE"},{"key":"5753_CR22","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1016\/j.jot.2020.06.002","volume":"24","author":"C Schopper","year":"2020","unstructured":"Schopper C, Zderic I, Menze J, Muller D, Rocci M, Knobe M, et al. Higher stability and more predictive fixation with the femoral neck system versus Hansson pins in femoral neck fractures Pauwels II. J Orthop Translat. 2020;24:88\u201395.","journal-title":"J Orthop Translat"},{"issue":"7","key":"5753_CR23","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1016\/S0021-9290(01)00040-9","volume":"34","author":"G Bergmann","year":"2001","unstructured":"Bergmann G, Deuretzbacher G, Heller M, Graichen F, Rohlmann A, Strauss J, et al. Hip contact forces and gait patterns from routine activities. J Biomech. 2001;34(7):859\u201371.","journal-title":"J Biomech"},{"issue":"2","key":"5753_CR24","doi-asserted-by":"crossref","first-page":"140","DOI":"10.55095\/achot2015\/020","volume":"82","author":"Y Imren","year":"2015","unstructured":"Imren Y, Gurkan V, Bilsel K, Desteli EE, Tuna M, Gurcan C, et al. Biomechanical comparison of dynamic hip screw, proximal femoral nail, cannulated screw, and monoaxial external fixation in the treatment of basicervical femoral neck fractures. Acta Chir Orthop Traumatol Cech. 2015;82(2):140\u20134.","journal-title":"Acta Chir Orthop Traumatol Cech"},{"key":"5753_CR25","first-page":"7618079","volume":"2018","author":"DK Kwak","year":"2018","unstructured":"Kwak DK, Kim WH, Lee SJ, Rhyu SH, Jang CY, Yoo JH. Biomechanical comparison of three different intramedullary nails for fixation of unstable basicervical intertrochanteric fractures of the proximal femur: experimental studies. Biomed Res Int. 2018;2018:7618079.","journal-title":"Biomed Res Int"},{"issue":"3","key":"5753_CR26","doi-asserted-by":"crossref","first-page":"467","DOI":"10.1007\/s00590-021-03005-0","volume":"32","author":"CR Perskin","year":"2022","unstructured":"Perskin CR, Seetharam A, Mullis BH, Marcantonio AJ, Garfi J, Ment AJ, et al. Peri-implant fractures of the upper and lower extremities: a case series of 61 fractures. Eur J Orthop Surg Traumatol. 2022;32(3):467\u201374.","journal-title":"Eur J Orthop Surg Traumatol"},{"issue":"2","key":"5753_CR27","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1097\/00005131-199004020-00012","volume":"4","author":"TA DeCoster","year":"1990","unstructured":"DeCoster TA, Heetderks DB, Downey DJ, Ferries JS, Jones W. Optimizing bone screw pullout force. J Orthop Trauma. 1990;4(2):169\u201374.","journal-title":"J Orthop Trauma"},{"issue":"7","key":"5753_CR28","doi-asserted-by":"crossref","first-page":"462","DOI":"10.1097\/00005131-199610000-00003","volume":"10","author":"SE Asnis","year":"1996","unstructured":"Asnis SE, Ernberg JJ, Bostrom MP, Wright TM, Harrington RM, Tencer A, et al. Cancellous bone screw thread design and holding power. J Orthop Trauma. 1996;10(7):462\u20139.","journal-title":"J Orthop Trauma"},{"issue":"Suppl 4","key":"5753_CR29","doi-asserted-by":"crossref","first-page":"SD1","DOI":"10.1016\/S0020-1383(01)00168-1","volume":"32","author":"T Gausepohl","year":"2001","unstructured":"Gausepohl T, Mohring R, Pennig D, Koebke J. Fine thread versus coarse thread. A comparison of the maximum holding power. Injury. 2001;32(Suppl 4):SD1\u20137.","journal-title":"Injury"},{"issue":"Suppl 2","key":"5753_CR30","doi-asserted-by":"crossref","first-page":"S107","DOI":"10.1007\/s00198-004-1777-0","volume":"16","author":"J Seebeck","year":"2005","unstructured":"Seebeck J, Goldhahn J, Morlock MM, Schneider E. Mechanical behavior of screws in normal and osteoporotic bone. Osteoporos Int. 2005;16(Suppl 2):S107\u201311.","journal-title":"Osteoporos Int"},{"issue":"10","key":"5753_CR31","doi-asserted-by":"crossref","first-page":"656","DOI":"10.1016\/0020-1383(93)90314-V","volume":"24","author":"K Stromsoe","year":"1993","unstructured":"Stromsoe K, Kok WL, Hoiseth A, Alho A. Holding power of the 4.5\u00a0mm AO\/ASIF cortex screw in cortical bone in relation to bone mineral. Injury. 1993;24(10):656\u20139.","journal-title":"Injury"},{"issue":"9","key":"5753_CR32","doi-asserted-by":"crossref","first-page":"1259","DOI":"10.1302\/0301-620X.93B9.26721","volume":"93","author":"D Wahnert","year":"2011","unstructured":"Wahnert D, Windolf M, Brianza S, Rothstock S, Radtke R, Brighenti V, et al. A comparison of parallel and diverging screw angles in the stability of locked plate constructs. J Bone Joint Surg Br. 2011;93(9):1259\u201364.","journal-title":"J Bone Joint Surg Br"},{"issue":"8","key":"5753_CR33","doi-asserted-by":"crossref","first-page":"1624","DOI":"10.1016\/j.injury.2016.06.001","volume":"47","author":"JE Tidwell","year":"2016","unstructured":"Tidwell JE, Roush EP, Ondeck CL, Kunselman AR, Reid JS, Lewis GS. The Biomechanical cost of variable angle locking screws. Injury. 2016;47(8):1624\u201330.","journal-title":"Injury"},{"issue":"10","key":"5753_CR34","doi-asserted-by":"crossref","first-page":"1358","DOI":"10.1016\/j.injury.2013.06.013","volume":"44","author":"J Hebert-Davies","year":"2013","unstructured":"Hebert-Davies J, Laflamme GY, Rouleau D, Canet F, Sandman E, Li A, et al. A Biomechanical study comparing polyaxial locking screw mechanisms. Injury. 2013;44(10):1358\u201362.","journal-title":"Injury"},{"issue":"Suppl 1","key":"5753_CR35","doi-asserted-by":"crossref","first-page":"S2","DOI":"10.1097\/BOT.0000000000000066","volume":"28","author":"JL Cartner","year":"2014","unstructured":"Cartner JL, Petteys T, Tornetta P 3. Mechanical effects of off-axis insertion of locking screws: should we do it? J Orthop Trauma. 2014;28(Suppl 1):S2\u20135.","journal-title":"J Orthop Trauma"},{"issue":"7","key":"5753_CR36","doi-asserted-by":"crossref","first-page":"988","DOI":"10.1002\/jor.22851","volume":"33","author":"M Lenz","year":"2015","unstructured":"Lenz M, Wahl D, Gueorguiev B, Jupiter JB, Perren SM. Concept of variable angle locking\u2013evolution and mechanical evaluation of a recent technology. J Orthop Res. 2015;33(7):988\u201392.","journal-title":"J Orthop Res"},{"issue":"1","key":"5753_CR37","doi-asserted-by":"crossref","first-page":"21740","DOI":"10.1038\/s41598-023-48791-1","volume":"13","author":"J Glowacki","year":"2023","unstructured":"Glowacki J, Bartkowiak T, Paczos P, Gapinski B, Mietlinski P, Zawadzki P, et al. Effect of screw angulation on the bending performance of polyaxial locking interfaces: a micro-CT evaluation. Sci Rep. 2023;13(1):21740.","journal-title":"Sci Rep"},{"issue":"9","key":"5753_CR38","doi-asserted-by":"crossref","first-page":"1245","DOI":"10.1007\/s00402-019-03185-9","volume":"139","author":"CH Ma","year":"2019","unstructured":"Ma CH, Chiu YC, Wu CH, Tsai KL, Wen TK, Jou IM, et al. Plate-on-plate technique for treating peri-implant fractures of distal femoral locking plate: a retrospective study of 11 patients. Arch Orthop Trauma Surg. 2019;139(9):1245\u201351.","journal-title":"Arch Orthop Trauma Surg"},{"key":"5753_CR39","doi-asserted-by":"crossref","unstructured":"Zdero R, Djuricic A, Schemitsch EH. Mechanical properties of synthetic bones made by Synbone: A review. J Biomech Eng. 2023;145(12).","DOI":"10.1115\/1.4063123"},{"issue":"3","key":"5753_CR40","doi-asserted-by":"crossref","first-page":"613","DOI":"10.1007\/s10439-009-9887-7","volume":"38","author":"MP Gardner","year":"2010","unstructured":"Gardner MP, Chong AC, Pollock AG, Wooley PH. Mechanical evaluation of large-size fourth-generation composite femur and tibia models. Ann Biomed Eng. 2010;38(3):613\u201320.","journal-title":"Ann Biomed Eng"},{"issue":"2","key":"5753_CR41","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1115\/1.2540926","volume":"129","author":"R Zdero","year":"2007","unstructured":"Zdero R, Rose S, Schemitsch EH, Papini M. Cortical screw pullout strength and effective shear stress in synthetic third generation composite femurs. J Biomech Eng. 2007;129(2):289\u201393.","journal-title":"J Biomech Eng"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-025-05753-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13018-025-05753-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-025-05753-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,5]],"date-time":"2025-04-05T02:31:50Z","timestamp":1743820310000},"score":1,"resource":{"primary":{"URL":"https:\/\/josr-online.biomedcentral.com\/articles\/10.1186\/s13018-025-05753-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,4]]},"references-count":41,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["5753"],"URL":"https:\/\/doi.org\/10.1186\/s13018-025-05753-9","relation":{},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4,4]]},"assertion":[{"value":"26 January 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 March 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 April 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable, this study does not report on or involve the use of any animal or human data or tissue.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable, this manuscript does not contain data from any individual person.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"340"}}