{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,4,24]],"date-time":"2025-04-24T04:07:30Z","timestamp":1745467650971,"version":"3.40.4"},"reference-count":19,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,4,23]],"date-time":"2025-04-23T00:00:00Z","timestamp":1745366400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2025,4,23]],"date-time":"2025-04-23T00:00:00Z","timestamp":1745366400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"DOI":"10.1186\/s13018-025-05823-y","type":"journal-article","created":{"date-parts":[[2025,4,23]],"date-time":"2025-04-23T06:18:00Z","timestamp":1745389080000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["A safe technical modification and mid-term results in the removal of locking screws with damaged heads"],"prefix":"10.1186","volume":"20","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6051-9117","authenticated-orcid":false,"given":"Abdurrahman","family":"Ozcelik","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0280-2088","authenticated-orcid":false,"given":"Mustafa","family":"Kavak","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,4,23]]},"reference":[{"key":"5823_CR1","doi-asserted-by":"publisher","unstructured":"Suzuki T, Smith WR, Stahel PF, Morgan SJ, Baron AJ, Hak DJ. Technical problems and complications in the removal of the less invasive stabilization system. J Orthop Trauma. 2010;24(6):369\u2013\u200973. https:\/\/doi.org\/10.1097\/BOT.0b013e3181c29bf5. PMID: 20502220.","DOI":"10.1097\/BOT.0b013e3181c29bf5"},{"issue":"2","key":"5823_CR2","doi-asserted-by":"publisher","first-page":"613","DOI":"10.1007\/s11999-010-1508-0","volume":"469","author":"G Kumar","year":"2011","unstructured":"Kumar G, Dunlop C. Case report: A technique to remove a jammed locking screw from a locking plate. Clin Orthop Relat Res. 2011;469(2):613\u20136. https:\/\/doi.org\/10.1007\/s11999-010-1508-0. Epub 2010 Aug 11. PMID: 20700670; PMCID: PMC3018209.","journal-title":"Clin Orthop Relat Res"},{"key":"5823_CR3","doi-asserted-by":"publisher","unstructured":"Bae JH, Oh JK, Oh CW, Hur CR. Technical difficulties of removal of locking screw after locking compression plating. Arch Orthop Trauma Surg. 2009;129(1):91\u2013\u20095. https:\/\/doi.org\/10.1007\/s00402-008-0769-5. Epub 2008 Oct 18. PMID: 18931851.","DOI":"10.1007\/s00402-008-0769-5"},{"key":"5823_CR4","doi-asserted-by":"publisher","unstructured":"Ehlinger M, Adam P, Simon P, Bonnomet F. Technical difficulties in hardware removal in titanium compression plates with locking screws. Orthop Traumatol Surg Res. 2009;95(5):373-6. https:\/\/doi.org\/10.1016\/j.otsr.2009.03.020. Epub 2009 Aug 3. PMID: 19648072.","DOI":"10.1016\/j.otsr.2009.03.020"},{"issue":"7","key":"5823_CR5","doi-asserted-by":"publisher","first-page":"502","DOI":"10.1308\/003588412X13373405386411","volume":"94","author":"S Raja","year":"2012","unstructured":"Raja S, Imbuldeniya AM, Garg S, Groom G. Difficulties encountered removing locked plates. Ann R Coll Surg Engl. 2012;94(7):502\u20135. https:\/\/doi.org\/10.1308\/003588412X13373405386411. PMID: 23031770; PMCID: PMC3954247.","journal-title":"Ann R Coll Surg Engl"},{"key":"5823_CR6","doi-asserted-by":"publisher","unstructured":"Georgiadis GM, Gove NK, Smith AD, Rodway IP. Removal of the less invasive stabilization system. J Orthop Trauma. 2004;18(8):562-4. https:\/\/doi.org\/10.1097\/00005131-200409000-00014. PMID: 15475854.","DOI":"10.1097\/00005131-200409000-00014"},{"key":"5823_CR7","doi-asserted-by":"publisher","unstructured":"Hak DJ, McElvany M. Removal of broken hardware. J Am Acad Orthop Surg. 2008;16(2):113\u2013\u200920. https:\/\/doi.org\/10.5435\/00124635-200802000-00009. PMID: 18252842.","DOI":"10.5435\/00124635-200802000-00009"},{"key":"5823_CR8","doi-asserted-by":"publisher","unstructured":"Hamilton P, Doig S, Williamson O. Technical difficulty of metal removal after LISS plating. Injury. 2004;35(6):626-8. https:\/\/doi.org\/10.1016\/S0020-1383(03)00097-4. PMID: 15135284.","DOI":"10.1016\/S0020-1383(03)00097-4"},{"key":"5823_CR9","doi-asserted-by":"publisher","unstructured":"Chen YC, Hsiao CK, Tu YK, Tsai YJ, Hsiao AC, Lu CW, Yang CY. Assessment of heat generation and risk of thermal necrosis during bone burring by means of three-dimensional dynamic elastoplastic finite element modelling. Med Eng Phys. 2020;81:1\u201312. https:\/\/doi.org\/10.1016\/j.medengphy.2020.04.008. Epub 2020 May 11. PMID: 32475768.","DOI":"10.1016\/j.medengphy.2020.04.008"},{"key":"5823_CR10","doi-asserted-by":"crossref","unstructured":"Bhutta MA, Dunkow PD, Lovell ME. A simple technique for removal of screws with damaged heads. Ann R Coll Surg Engl. 2003;85(3):207. doi: 10.1308\/003588403321661442. Erratum in: Ann R Coll Surg Engl. 2003 Jul;85(4):285. PMID: 12836655; PMCID: PMC1964382.","DOI":"10.1308\/003588403321661442"},{"key":"5823_CR11","doi-asserted-by":"publisher","unstructured":"Pattison G, Reynolds J, Hardy J. Salvaging a stripped drive connection when removing screws. Injury. 1999;30(1):74\u2013\u20095. https:\/\/doi.org\/10.1016\/s0020-1383(98)00207-1. PMID: 10396464.","DOI":"10.1016\/s0020-1383(98)00207-1"},{"key":"5823_CR12","doi-asserted-by":"publisher","unstructured":"Hammarstedt JE, Gershkovich GE, Mass DP. Use of high-speed burr and water-based lubricant in the partial removal of surgical plates: A technique guide. J Clin Orthop Trauma. 2019 Mar-Apr;10(2):422\u20136. https:\/\/doi.org\/10.1016\/j.jcot.2018.05.015. Epub 2018 May 24.","DOI":"10.1016\/j.jcot.2018.05.015"},{"key":"5823_CR13","doi-asserted-by":"publisher","unstructured":"Gopinathan NR, Dhillon MS, Kumar R. Surgical technique: Simple technique for removing a locking recon plate with damaged screw heads. Clin Orthop Relat Res. 2013;471(5):1572-5. https:\/\/doi.org\/10.1007\/s11999-012-2733-5. Epub 2012 Dec 11. PMID: 23229429; PMCID: PMC3613543.","DOI":"10.1007\/s11999-012-2733-5"},{"key":"5823_CR14","doi-asserted-by":"publisher","unstructured":"13.Bae JH, Oh JK, Oh CW, Hur CR. Technical difficulties of removal of locking compression plating. Arch Orthop Trauma Surg. 2009;123(1):91\u2013\u20095. https:\/\/doi.org\/10.1007\/s00402-008-0769-5. Epub 2008 Oct 18.PMID: 18931851.","DOI":"10.1007\/s00402-008-0769-5"},{"key":"5823_CR15","doi-asserted-by":"publisher","unstructured":"14.Kim SJ, Kim MU. A simple technique for removing a locking compression plate with a stripped locking screw. J Orthop Trauma. 2012;26(6):e51-3. https:\/\/doi.org\/10.1097\/BOT.0b013e318220ac51.PMID: 22048181.","DOI":"10.1097\/BOT.0b013e318220ac51"},{"key":"5823_CR16","doi-asserted-by":"publisher","first-page":"134","DOI":"10.1016\/j.ijscr.2019.03.046","volume":"57","author":"WR Park","year":"2019","unstructured":"Park WR, Jang JH. An inexpensive and rapid method for removal of multiple stripped locking screws following locking plating: A case report. Int J Surg Case Rep. 2019;57:134\u20137. https:\/\/doi.org\/10.1016\/j.ijscr.2019.03.046. Epub 2019 Mar 30. PMID: 30959360; PMCID: PMC6453824.","journal-title":"Int J Surg Case Rep"},{"issue":"6","key":"5823_CR17","doi-asserted-by":"publisher","first-page":"1119","DOI":"10.1007\/s00590-020-02667-6","volume":"30","author":"A Kumar","year":"2020","unstructured":"Kumar A, Saini M, Jameel J, Khan R. Turn the tail, not the head: a simple, quick and inexpensive technique for the safe removal of jammed\/stripped locking screws. Eur J Orthop Surg Traumatol. 2020;30(6):1119\u201323. https:\/\/doi.org\/10.1007\/s00590-020-02667-6. Epub 2020 Apr 10. PMID: 32277294.","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"5823_CR18","doi-asserted-by":"publisher","unstructured":"Schwarz N, Euler S, Schlittler M, Ulbing T, Wilhelm P, Fronh\u00f6fer G, Irnstorfer M. Technical complications during removal of locking screws from locking compression plates: a prospective multicenter study. Eur J Trauma Emerg Surg. 2013;39(4):339\u2013\u200944. https:\/\/doi.org\/10.1007\/s00068-013-0301-7. Epub 2013 Jun 4. PMID: 26815393.","DOI":"10.1007\/s00068-013-0301-7"},{"key":"5823_CR19","doi-asserted-by":"publisher","unstructured":"Fujita K, Yasutake H, Horii T, Hashimoto N, Kabata T, Tsuchiya H. Difficulty in locking head screw removal. J Orthop Sci. 2014;19(2):304\u2013307. https:\/\/doi.org\/10.1007\/s00776-013-0503-1. Epub 2013 Dec 3. PMID: 24297627.","DOI":"10.1007\/s00776-013-0503-1"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-025-05823-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13018-025-05823-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-025-05823-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,23]],"date-time":"2025-04-23T06:18:06Z","timestamp":1745389086000},"score":1,"resource":{"primary":{"URL":"https:\/\/josr-online.biomedcentral.com\/articles\/10.1186\/s13018-025-05823-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,23]]},"references-count":19,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["5823"],"URL":"https:\/\/doi.org\/10.1186\/s13018-025-05823-y","relation":{},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4,23]]},"assertion":[{"value":"18 February 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 April 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 April 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"None of the authors have financial disclosures.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}],"article-number":"406"}}