{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,12]],"date-time":"2026-02-12T07:41:47Z","timestamp":1770882107641,"version":"3.50.1"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,6,19]],"date-time":"2025-06-19T00:00:00Z","timestamp":1750291200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,6,19]],"date-time":"2025-06-19T00:00:00Z","timestamp":1750291200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>Locking plates and screws are essential in orthopedic surgeries, including opening-wedge high tibial osteotomy (OWHTO), owing to their ability to provide angular stability and support under mechanical stress. However, screw breakage at the head and neck junction remains a significant issue, compromising fixation and requiring revision surgery. This study aimed to determine whether increasing the diameter of the locking screws at the head and neck junctions enhances biomechanical stability.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>Sixty screws, divided into two groups (<jats:italic>n<\/jats:italic>\u2009=\u200930 per group) \u2014a non-reinforced group with a standard design and a reinforced group with an increased head and neck diameter\u2014 were tested. Both groups consisted of 5.0\u00a0mm locking screws, each with a length of 80\u00a0mm. Biomechanical testing, which included compression, fatigue, and torsional strength tests, was conducted to reflect clinically relevant conditions.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>The reinforced screws demonstrated significantly superior biomechanical performance. In the compression test, they exhibited a higher load to failure (909.0\u2009\u00b1\u200930.4\u00a0N vs. 757.5\u2009\u00b1\u200946.2\u00a0N, <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001). In the fatigue test, the reinforced screws endured more cycles before failure (70788.6\u2009\u00b1\u20096310.6 cycles vs. 23016.2\u2009\u00b1\u20095,157.9 cycles, <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001) and had a greater displacement distance (3.0\u2009\u00b1\u20090.4\u00a0mm vs. 2.3\u2009\u00b1\u20090.3\u00a0mm, <jats:italic>p<\/jats:italic>\u2009=\u20090.001). The torsional test showed higher torque at failure for the reinforced screws (17.3\u2009\u00b1\u20090.3 Nm vs. 16.5\u2009\u00b1\u20090.4 Nm, <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001), although the angular displacement differences were not statistically significant (202.0\u00b0 \u00b1 63.9\u00b0 vs. 247.2\u00b0 \u00b1 64.9\u00b0, <jats:italic>p<\/jats:italic>\u2009=\u20090.105).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>Reinforcing the head and neck junction of locking screws significantly improves their biomechanical performance. These findings suggest that structural modifications can reduce hardware failure risks in high-stress procedures such as OWHTO, enhancing implant durability and clinical outcomes.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1186\/s13018-025-06015-4","type":"journal-article","created":{"date-parts":[[2025,6,19]],"date-time":"2025-06-19T04:35:49Z","timestamp":1750307749000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Reinforced locking screws with enhanced head and neck junction: improving biomechanical stability in opening-wedge high tibial osteotomy applications"],"prefix":"10.1186","volume":"20","author":[{"given":"Kyung-Wook","family":"Nha","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hyungsuh","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kyoung-Tak","family":"Kang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jae Gyoon","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hyung Jun","family":"Park","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,6,19]]},"reference":[{"key":"6015_CR1","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1007\/s00402-008-0769-5","volume":"129","author":"JH Bae","year":"2009","unstructured":"Bae JH, Oh JK, Oh CW, Hur CR. Technical difficulties of removal of locking screw after locking compression plating. Arch Orthop Trauma Surg. 2009;129:91\u20135.","journal-title":"Arch Orthop Trauma Surg"},{"issue":"Suppl 2","key":"6015_CR2","doi-asserted-by":"publisher","first-page":"B6","DOI":"10.1016\/j.injury.2003.09.020","volume":"34","author":"R Frigg","year":"2003","unstructured":"Frigg R. Development of the locking compression plate. Injury. 2003;34(Suppl 2):B6\u201310.","journal-title":"Injury"},{"key":"6015_CR3","doi-asserted-by":"publisher","first-page":"2298","DOI":"10.2106\/00004623-200710000-00028","volume":"89","author":"WR Smith","year":"2007","unstructured":"Smith WR, Ziran BH, Anglen JO, Stahel PF. Locking plates: tips and tricks. J Bone Joint Surg Am. 2007;89:2298\u2013307.","journal-title":"J Bone Joint Surg Am"},{"key":"6015_CR4","doi-asserted-by":"publisher","first-page":"808","DOI":"10.1007\/s00167-015-3850-y","volume":"25","author":"JH Han","year":"2017","unstructured":"Han JH, Kim HJ, Song JG, Yang JH, Nakamura R, Shah D, et al. Locking plate versus non-locking plate in open-wedge high tibial osteotomy: a meta-analysis. Knee Surg Sports Traumatol Arthrosc. 2017;25:808\u201316.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"6015_CR5","doi-asserted-by":"publisher","first-page":"3015","DOI":"10.1007\/s00167-022-07229-3","volume":"31","author":"MH van Haeringen","year":"2023","unstructured":"van Haeringen MH, Kuijer P, Daams JG, van Geenen RCI, Brinkman JM, Kerkhoffs G, et al. Opening- and closing-wedge high tibial osteotomy are comparable and early full weight bearing is safe with angular stable plate fixation: a meta-analysis. Knee Surg Sports Traumatol Arthrosc. 2023;31:3015\u201326.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"6015_CR6","doi-asserted-by":"publisher","first-page":"571","DOI":"10.1097\/00005131-200409000-00016","volume":"18","author":"C Sommer","year":"2004","unstructured":"Sommer C, Babst R, Muller M, Hanson B. Locking compression plate loosening and plate breakage: a report of four cases. J Orthop Trauma. 2004;18:571\u20137.","journal-title":"J Orthop Trauma"},{"key":"6015_CR7","doi-asserted-by":"publisher","first-page":"439","DOI":"10.1016\/j.arth.2018.11.009","volume":"34","author":"SB Han","year":"2019","unstructured":"Han SB, In Y, Oh KJ, Song KY, Yun ST, Jang KM. Complications associated with medial Opening-Wedge high tibial osteotomy using a locking plate: A multicenter study. J Arthroplasty. 2019;34:439\u201345.","journal-title":"J Arthroplasty"},{"key":"6015_CR8","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1097\/BOT.0b013e3181e31ccc","volume":"25","author":"PJ Glassner","year":"2011","unstructured":"Glassner PJ, Tejwani NC. Failure of proximal femoral locking compression plate: a case series. J Orthop Trauma. 2011;25:76\u201383.","journal-title":"J Orthop Trauma"},{"key":"6015_CR9","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1007\/s00264-009-0723-3","volume":"34","author":"EM Nelissen","year":"2010","unstructured":"Nelissen EM, van Langelaan EJ, Nelissen RG. Stability of medial opening wedge high tibial osteotomy: a failure analysis. Int Orthop. 2010;34:217\u201323.","journal-title":"Int Orthop"},{"key":"6015_CR10","doi-asserted-by":"publisher","first-page":"230","DOI":"10.1016\/j.knee.2024.11.012","volume":"52","author":"KW Nha","year":"2025","unstructured":"Nha KW, Kim HS, Kim JM, Tawonsawatruk T, Kim SG. Clinical outcome and complications after simultaneous bilateral medial opening-wedge high tibial osteotomy. Knee. 2025;52:230\u20137.","journal-title":"Knee"},{"key":"6015_CR11","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1186\/s13256-019-2046-3","volume":"13","author":"R Batash","year":"2019","unstructured":"Batash R, Debi R, Grinberg D, Shema M, Elbaz A, Benedict Y. Mechanical failure of plate breakage after open reduction and plate fixation of displaced midshaft clavicle fracture - a possible new risk factor: a case report. J Med Case Rep. 2019;13:127.","journal-title":"J Med Case Rep"},{"key":"6015_CR12","doi-asserted-by":"publisher","first-page":"6345","DOI":"10.3390\/jcm12196345","volume":"12","author":"J Yoo","year":"2023","unstructured":"Yoo J, Kwak D, Kim J, Kwon S, Kwon J, Hwang J. Risk factors of proximal screw breakage of locking plate (ZPLP((R))) after MIPO for distal femur fractures -Analysis of patients with plate removal after bony union. J Clin Med. 2023;12:6345.","journal-title":"J Clin Med"},{"key":"6015_CR13","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1186\/s13018-019-1062-8","volume":"14","author":"YN Chen","year":"2019","unstructured":"Chen YN, Chang CW, Li CT, Chen CH, Chung CR, Chang CH, et al. Biomechanical investigation of the type and configuration of screws used in high tibial osteotomy with titanium locking plate and screw fixation. J Orthop Surg Res. 2019;14:35.","journal-title":"J Orthop Surg Res"},{"issue":"Suppl 4","key":"6015_CR14","doi-asserted-by":"publisher","first-page":"S24","DOI":"10.1016\/S0020-1383(15)30015-2","volume":"46","author":"M Heyland","year":"2015","unstructured":"Heyland M, Duda GN, Haas NP, Trepczynski A, Dobele S, Hontzsch D, et al. Semi-rigid screws provide an auxiliary option to plate working length to control interfragmentary movement in locking plate fixation at the distal femur. Injury. 2015;46(Suppl 4):S24\u201332.","journal-title":"Injury"},{"key":"6015_CR15","doi-asserted-by":"publisher","first-page":"1648","DOI":"10.1016\/j.injury.2014.04.018","volume":"45","author":"G Roderer","year":"2014","unstructured":"Roderer G, Gebhard F, Duerselen L, Ignatius A, Claes L. Delayed bone healing following high tibial osteotomy related to increased implant stiffness in locked plating. Injury. 2014;45:1648\u201352.","journal-title":"Injury"},{"key":"6015_CR16","doi-asserted-by":"publisher","first-page":"427","DOI":"10.1097\/BOT.0000000000000042","volume":"28","author":"B Gallagher","year":"2014","unstructured":"Gallagher B, Silva MJ, Ricci WM. Effect of off-axis screw insertion, insertion torque, and plate contouring on locked screw strength. J Orthop Trauma. 2014;28:427\u201332.","journal-title":"J Orthop Trauma"},{"key":"6015_CR17","doi-asserted-by":"publisher","first-page":"1669","DOI":"10.1002\/jor.24881","volume":"39","author":"D Jiang","year":"2021","unstructured":"Jiang D, Zhan S, Wang L, Shi LL, Ling M, Hu H, et al. Biomechanical comparison of five cannulated screw fixation strategies for young vertical femoral neck fractures. J Orthop Res. 2021;39:1669\u201380.","journal-title":"J Orthop Res"},{"key":"6015_CR18","doi-asserted-by":"publisher","first-page":"488","DOI":"10.1097\/00005131-200409000-00003","volume":"18","author":"KA Egol","year":"2004","unstructured":"Egol KA, Kubiak EN, Fulkerson E, Kummer FJ, Koval KJ. Biomechanics of locked plates and screws. J Orthop Trauma. 2004;18:488\u201393.","journal-title":"J Orthop Trauma"},{"key":"6015_CR19","doi-asserted-by":"publisher","first-page":"1624","DOI":"10.1016\/j.injury.2016.06.001","volume":"47","author":"JE Tidwell","year":"2016","unstructured":"Tidwell JE, Roush EP, Ondeck CL, Kunselman AR, Reid JS, Lewis GS. The Biomechanical cost of variable angle locking screws. Injury. 2016;47:1624\u201330.","journal-title":"Injury"},{"key":"6015_CR20","doi-asserted-by":"publisher","first-page":"155","DOI":"10.5792\/ksrr.2014.26.3.155","volume":"26","author":"SB Han","year":"2014","unstructured":"Han SB, Bae JH, Lee SJ, Jung TG, Kim KH, Kwon JH, et al. Biomechanical properties of a new anatomical locking metal block plate for opening wedge high tibial osteotomy: uniplane osteotomy. Knee Surg Relat Res. 2014;26:155\u201361.","journal-title":"Knee Surg Relat Res"},{"key":"6015_CR21","doi-asserted-by":"publisher","first-page":"379","DOI":"10.1097\/00005373-199908000-00030","volume":"47","author":"C Gaebler","year":"1999","unstructured":"Gaebler C, Stanzl-Tschegg S, Heinze G, Holper B, Milne T, Berger G, et al. Fatigue strength of locking screws and prototypes used in small-diameter tibial nails: a Biomechanical study. J Trauma. 1999;47:379\u201384.","journal-title":"J Trauma"},{"key":"6015_CR22","doi-asserted-by":"publisher","first-page":"258","DOI":"10.21037\/atm-22-4886","volume":"11","author":"DW Koch","year":"2023","unstructured":"Koch DW, Johnson JW, Smith QE, Brekhus C, Gadomski BC, Palmer RH, et al. Biomechanical evaluation of interlocking nail and locking compression plating for stabilization of ovine critical-sized segmental tibia defects. Ann Transl Med. 2023;11:258.","journal-title":"Ann Transl Med"},{"key":"6015_CR23","doi-asserted-by":"publisher","first-page":"579","DOI":"10.2478\/abm-2010-0073","volume":"4","author":"P Tienboon","year":"2010","unstructured":"Tienboon P, Jaruwangsanti N. Rod stiffness effect on adjacent segmental degeneration: a comparative long-term study. Asian Biomed. 2010;4:579\u201384.","journal-title":"Asian Biomed"},{"key":"6015_CR24","doi-asserted-by":"publisher","first-page":"e278","DOI":"10.1097\/OI9.0000000000000278","volume":"6","author":"JM Wahbeh","year":"2023","unstructured":"Wahbeh JM, Kelley BV, Shokoohi C, Park SH, Devana SK, Ebramzadeh E, et al. Comparison of a 2.7-mm and 3.5-mm locking compression plate for ulnar fractures: a Biomechanical evaluation. OTA Int. 2023;6:e278.","journal-title":"OTA Int"},{"key":"6015_CR25","doi-asserted-by":"publisher","first-page":"218","DOI":"10.1055\/s-0030-1247752","volume":"22","author":"KP Valkering","year":"2009","unstructured":"Valkering KP, van den Bekerom MP, Kappelhoff FM, Albers GH. Complications after Tomofix medial opening wedge high tibial osteotomy. J Knee Surg. 2009;22:218\u201325.","journal-title":"J Knee Surg"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-025-06015-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13018-025-06015-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-025-06015-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,19]],"date-time":"2025-06-19T04:35:49Z","timestamp":1750307749000},"score":1,"resource":{"primary":{"URL":"https:\/\/josr-online.biomedcentral.com\/articles\/10.1186\/s13018-025-06015-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,19]]},"references-count":25,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["6015"],"URL":"https:\/\/doi.org\/10.1186\/s13018-025-06015-4","relation":{},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,19]]},"assertion":[{"value":"17 February 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 June 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 June 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study did not involve human participants or animal subjects; therefore, approval from the Institutional Review Board was not required.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"There is nothing to declare.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"603"}}