{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,18]],"date-time":"2026-11-18T02:10:14Z","timestamp":1794967814801,"version":"4.9.1"},"reference-count":42,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,11,14]],"date-time":"2025-11-14T00:00:00Z","timestamp":1763078400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2025,11,14]],"date-time":"2025-11-14T00:00:00Z","timestamp":1763078400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"name":"Australian Reserach Council","award":["IC180100024"],"award-info":[{"award-number":["IC180100024"]}]},{"name":"Australian Reserach Council","award":["IC180100024"],"award-info":[{"award-number":["IC180100024"]}]},{"name":"Australian Reserach Council","award":["IC180100024"],"award-info":[{"award-number":["IC180100024"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"DOI":"10.1186\/s13018-025-06389-5","type":"journal-article","created":{"date-parts":[[2025,11,14]],"date-time":"2025-11-14T16:42:46Z","timestamp":1763138566000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Design and optimisation of patient-specific porous femoral stems"],"prefix":"10.1186","volume":"20","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2589-5694","authenticated-orcid":false,"given":"Sarah","family":"Safavi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2587-8747","authenticated-orcid":false,"given":"Hans A.","family":"Gray","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3666-4872","authenticated-orcid":false,"given":"Peter V. S.","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,11,14]]},"reference":[{"key":"6389_CR1","unstructured":"World Health Organization. Osteoarthritis. https:\/\/www.who.int\/news-room\/fact-sheets\/detail\/osteoarthritis."},{"key":"6389_CR2","unstructured":"Hip, Knee & Shoulder Arthroplasty. In: Hip, knee & shoulder arthroplasty. Australian Orthopaedic Association National Joint Replacement Registry; 2024."},{"key":"6389_CR3","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.94B5.27073","author":"IS Vanhegan","year":"2012","unstructured":"Vanhegan IS, Malik AK, Jayakumar P, Islam SU, Haddad FS. A financial analysis of revision hip arthroplasty: the economic burden in relation to the national tariff. J Bone Joint Surg Br. 2012. https:\/\/doi.org\/10.1302\/0301-620X.94B5.27073.","journal-title":"J Bone Joint Surg Br"},{"key":"6389_CR4","doi-asserted-by":"publisher","DOI":"10.3390\/ma13214794","author":"D Martinez-Marquez","year":"2020","unstructured":"Martinez-Marquez D, Delmar Y, Sun S, Stewart RA. Exploring macroporosity of additively manufactured titanium metamaterials for bone regeneration with quality by design: a systematic literature review. Materials. 2020. https:\/\/doi.org\/10.3390\/ma13214794.","journal-title":"Materials"},{"key":"6389_CR5","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199201000-00010","author":"JD Bobyn","year":"1992","unstructured":"Bobyn JD, Mortimer ES, Glassman AH, Engh CA, Miller JE, Brooks CE. Producing and avoiding stress shielding. Laboratory and clinical observations of noncemented total hip arthroplasty. Clin Orthop Relat Res. 1992. https:\/\/doi.org\/10.1097\/00003086-199201000-00010.","journal-title":"Clin Orthop Relat Res"},{"key":"6389_CR6","doi-asserted-by":"publisher","DOI":"10.1097\/01.blo.0000246541.41951.20","author":"AH Glassman","year":"2006","unstructured":"Glassman AH, Bobyn JD, Tanzer M. New femoral designs: Do they influence stress shielding? Clin Orthop Relat Res. 2006. https:\/\/doi.org\/10.1097\/01.blo.0000246541.41951.20.","journal-title":"Clin Orthop Relat Res"},{"key":"6389_CR7","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199201000-00014","author":"R Huiskes","year":"1992","unstructured":"Huiskes R, Weinans H, Rietbergen BV. The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials. Clin Orthop Relat Res. 1992. https:\/\/doi.org\/10.1097\/00003086-199201000-00014.","journal-title":"Clin Orthop Relat Res"},{"key":"6389_CR8","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmst.2018.09.003","author":"LE Murr","year":"2019","unstructured":"Murr LE. Strategies for creating living, additively manufactured, open-cellular metal and alloy implants by promoting osseointegration, osteoinduction and vascularization: an overview. J Mater Sci Technol. 2019. https:\/\/doi.org\/10.1016\/j.jmst.2018.09.003.","journal-title":"J Mater Sci Technol"},{"key":"6389_CR9","doi-asserted-by":"publisher","DOI":"10.1186\/s13018-022-03492-9","author":"S Safavi","year":"2023","unstructured":"Safavi S, Yu Y, Robinson DL, Gray HA, Ackland DC, Lee PVS. Additively manufactured controlled porous orthopedic joint replacement designs to reduce bone stress shielding: a systematic review. J Orthop Surg Res. 2023. https:\/\/doi.org\/10.1186\/s13018-022-03492-9.","journal-title":"J Orthop Surg Res"},{"key":"6389_CR10","doi-asserted-by":"publisher","DOI":"10.1016\/j.mtcomm.2017.05.002","author":"S Limmahakhun","year":"2017","unstructured":"Limmahakhun S, Oloyede A, Chantarapanich N, Jiamwatthanachai P, Sitthiseripratip K, Xiao Y, et al. Alternative designs of load\u2212sharing cobalt chromium graded femoral stems. Mater Today Commun. 2017. https:\/\/doi.org\/10.1016\/j.mtcomm.2017.05.002.","journal-title":"Mater Today Commun"},{"key":"6389_CR11","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2020.05.003","author":"S Wang","year":"2020","unstructured":"Wang S, Zhou X, Liu L, Shi Z, Hao Y. On the design and properties of porous femoral stems with adjustable stiffness gradient. Med Eng Phys. 2020. https:\/\/doi.org\/10.1016\/j.medengphy.2020.05.003.","journal-title":"Med Eng Phys"},{"key":"6389_CR12","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2016.08.008","author":"M Piccinini","year":"2016","unstructured":"Piccinini M, Cugnoni J, Botsis J, Ammann P, Wiskott A. Numerical prediction of peri-implant bone adaptation: comparison of mechanical stimuli and sensitivity to modeling parameters. Med Eng Phys. 2016. https:\/\/doi.org\/10.1016\/j.medengphy.2016.08.008.","journal-title":"Med Eng Phys"},{"key":"6389_CR13","doi-asserted-by":"publisher","DOI":"10.1115\/1.4006115","author":"S Arabnejad Khanoki","year":"2012","unstructured":"Arabnejad Khanoki S, Pasini D. Multiscale design and multiobjective optimization of orthopedic hip implants with functionally graded cellular material. J Biomech Eng. 2012. https:\/\/doi.org\/10.1115\/1.4006115.","journal-title":"J Biomech Eng"},{"key":"6389_CR14","doi-asserted-by":"publisher","DOI":"10.1016\/j.matdes.2017.02.021","author":"M Dumas","year":"2017","unstructured":"Dumas M, Terriault P, Brailovski V. Modelling and characterization of a porosity graded lattice structure for additively manufactured biomaterials. Mater Des. 2017. https:\/\/doi.org\/10.1016\/j.matdes.2017.02.021.","journal-title":"Mater Des"},{"key":"6389_CR15","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2017.08.034","author":"B Jette","year":"2018","unstructured":"Jette B, Brailovski V, Dumas M, Simoneau C, Terriault P. Femoral stem incorporating a diamond cubic lattice structure: design, manufacture and testing. J Mech Behav Biomed Mater. 2018. https:\/\/doi.org\/10.1016\/j.jmbbm.2017.08.034.","journal-title":"J Mech Behav Biomed Mater"},{"key":"6389_CR16","unstructured":"CFR - Code of Federal Regulations Title 21. 2023. https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfcfr\/cfrsearch.cfm?fr=888.3358. 22 June 2023."},{"key":"6389_CR17","unstructured":"International Organization for Standardization. Mechanical testing of metals\u2014Ductility testing\u2014Compression test for porous and cellular metals-(ISO 13314) (2011)."},{"key":"6389_CR18","unstructured":"Bergmann, G. Orthoload. https:\/\/orthoload.com\/. 22 May 2023."},{"key":"6389_CR19","doi-asserted-by":"publisher","DOI":"10.3389\/fbioe.2024.1446829","author":"C Falcinelli","year":"2024","unstructured":"Falcinelli C, Cheong VS, Ellingsen LM, Helgason B. Segmentation methods for quantifying X-ray computed tomography based biomarkers to assess hip fracture risk: a systematic literature review. Front Bioeng Biotechnol. 2024. https:\/\/doi.org\/10.3389\/fbioe.2024.1446829.","journal-title":"Front Bioeng Biotechnol"},{"key":"6389_CR20","doi-asserted-by":"publisher","DOI":"10.3109\/17453678909149321","author":"JC Goh","year":"1989","unstructured":"Goh JC, Ang EJ, Bose K. Effect of preservation medium on the mechanical properties of cat bones. Acta Orthop Scand. 1989. https:\/\/doi.org\/10.3109\/17453678909149321.","journal-title":"Acta Orthop Scand"},{"key":"6389_CR21","doi-asserted-by":"publisher","DOI":"10.1080\/17453670810016759","author":"EH van Haaren","year":"2008","unstructured":"van Haaren EH, van der Zwaard BC, van der Veen AJ, Heyligers IC, Wuisman PI, Smit TH. Effect of long-term preservation on the mechanical properties of cortical bone in goats. Acta Orthop. 2008. https:\/\/doi.org\/10.1080\/17453670810016759.","journal-title":"Acta Orthop"},{"key":"6389_CR22","doi-asserted-by":"publisher","DOI":"10.1016\/s0021-9290(03)00071-x","author":"EF Morgan","year":"2003","unstructured":"Morgan EF, Bayraktar HH, Keaveny TM. Trabecular bone modulus\u2013density relationships depend on anatomic site. J Biomech. 2003. https:\/\/doi.org\/10.1016\/s0021-9290(03)00071-x.","journal-title":"J Biomech"},{"key":"6389_CR23","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0155612","author":"G Bergmann","year":"2016","unstructured":"Bergmann G, Bender A, Dymke J, Duda G, Damm P. Standardized loads acting in hip implants. PLoS ONE. 2016. https:\/\/doi.org\/10.1371\/journal.pone.0155612.","journal-title":"PLoS ONE"},{"key":"6389_CR24","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2004.05.022","author":"MO Heller","year":"2005","unstructured":"Heller MO, Bergmann G, Kassi JP, Claes L, Haas NP, Duda GN. Determination of muscle loading at the hip joint for use in pre-clinical testing. J Biomech. 2005. https:\/\/doi.org\/10.1016\/j.jbiomech.2004.05.022.","journal-title":"J Biomech"},{"key":"6389_CR25","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2006.10.038","author":"AD Speirs","year":"2007","unstructured":"Speirs AD, Heller MO, Duda GN, Taylor WR. Physiologically based boundary conditions in finite element modelling. J Biomech. 2007. https:\/\/doi.org\/10.1016\/j.jbiomech.2006.10.038.","journal-title":"J Biomech"},{"key":"6389_CR26","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2014.12.015","author":"S Amin Yavari","year":"2015","unstructured":"Amin Yavari S, Ahmadi SM, Wauthle R, Pouran B, Schrooten J, Weinans H, et al. Relationship between unit cell type and porosity and the fatigue behavior of selective laser melted meta-biomaterials. J Mech Behav Biomed Mater. 2015. https:\/\/doi.org\/10.1016\/j.jmbbm.2014.12.015.","journal-title":"J Mech Behav Biomed Mater"},{"key":"6389_CR27","doi-asserted-by":"crossref","unstructured":"Gruen TA, Mcneice GM, Amstutz HC. Modes of failure of cemented stem-type femoral components\u2014radiographic analysis of loosening. Clin Orthop Relat Res. 1979.","DOI":"10.1097\/00003086-197906000-00002"},{"key":"6389_CR28","doi-asserted-by":"publisher","DOI":"10.1115\/1.4039824","author":"RMA Al-Dirini","year":"2018","unstructured":"Al-Dirini RMA, O\u2019Rourke D, Huff D, Martelli S, Taylor M. Biomechanical robustness of a contemporary cementless stem to surgical variation in stem size and position. J Biomech Eng. 2018. https:\/\/doi.org\/10.1115\/1.4039824.","journal-title":"J Biomech Eng"},{"key":"6389_CR29","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2018.04.016","author":"B Eidel","year":"2018","unstructured":"Eidel B, Gote A, Ohrndorf A, Christ HJ. How can a short stem hip implant preserve the natural, pre-surgery force flow? A finite element analysis on a collar cortex compression concept (CO(4)). Med Eng Phys. 2018. https:\/\/doi.org\/10.1016\/j.medengphy.2018.04.016.","journal-title":"Med Eng Phys"},{"key":"6389_CR30","doi-asserted-by":"publisher","DOI":"10.3389\/fbioe.2023.1092361","author":"SA Naghavi","year":"2023","unstructured":"Naghavi SA, Tamaddon M, Garcia-Souto P, Moazen M, Taylor S, Hua J, et al. A novel hybrid design and modelling of a customised graded Ti-6Al-4V porous hip implant to reduce stress-shielding: an experimental and numerical analysis. Front Bioeng Biotechnol. 2023. https:\/\/doi.org\/10.3389\/fbioe.2023.1092361.","journal-title":"Front Bioeng Biotechnol"},{"key":"6389_CR31","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-198607000-00023","author":"RM Pilliar","year":"1986","unstructured":"Pilliar RM, Lee JM, Maniatopoulos C. Observations on the effect of movement on bone ingrowth into porous-surfaced implants. Clin Orthop Relat Res. 1986. https:\/\/doi.org\/10.1097\/00003086-198607000-00023.","journal-title":"Clin Orthop Relat Res"},{"key":"6389_CR32","doi-asserted-by":"publisher","DOI":"10.1002\/jor.23445","author":"S Arabnejad","year":"2017","unstructured":"Arabnejad S, Johnston B, Tanzer M, Pasini D. Fully porous 3D printed titanium femoral stem to reduce stress-shielding following total hip arthroplasty. J Orthop Res. 2017. https:\/\/doi.org\/10.1002\/jor.23445.","journal-title":"J Orthop Res"},{"key":"6389_CR33","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2014.12.019","author":"M Taylor","year":"2015","unstructured":"Taylor M, Prendergast PJ. Four decades of finite element analysis of orthopaedic devices: where are we now and what are the opportunities? J Biomech. 2015. https:\/\/doi.org\/10.1016\/j.jbiomech.2014.12.019.","journal-title":"J Biomech"},{"key":"6389_CR34","doi-asserted-by":"publisher","DOI":"10.1007\/s42235-018-0057-1","author":"C Sun","year":"2018","unstructured":"Sun C, Wang L, Kang J, Li D, Jin Z. Biomechanical optimization of elastic modulus distribution in porous femoral stem for artificial hip joints. J Bionic Eng. 2018. https:\/\/doi.org\/10.1007\/s42235-018-0057-1.","journal-title":"J Bionic Eng"},{"key":"6389_CR35","doi-asserted-by":"publisher","DOI":"10.1115\/1.4041208","author":"Y Wang","year":"2018","unstructured":"Wang Y, Arabnejad S, Tanzer M, Pasini D. Hip implant design with three-dimensional porous architecture of optimized graded density. J Mech Des. 2018. https:\/\/doi.org\/10.1115\/1.4041208.","journal-title":"J Mech Des"},{"key":"6389_CR36","doi-asserted-by":"publisher","DOI":"10.1177\/09544119221075140","author":"J Nomura","year":"2022","unstructured":"Nomura J, Takezawa A, Zhang H, Kitamura M. Design optimization of functionally graded lattice infill total hip arthroplasty stem for stress shielding reduction. Proc Inst Mech Eng H. 2022. https:\/\/doi.org\/10.1177\/09544119221075140.","journal-title":"Proc Inst Mech Eng H"},{"key":"6389_CR37","doi-asserted-by":"publisher","DOI":"10.1016\/j.cma.2022.115102","author":"E Garner","year":"2022","unstructured":"Garner E, Wu J, Zadpoor AA. Multi-objective design optimization of 3D micro-architected implants. Comput Methods Appl Mech Eng. 2022. https:\/\/doi.org\/10.1016\/j.cma.2022.115102.","journal-title":"Comput Methods Appl Mech Eng"},{"key":"6389_CR38","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-023-05825-7","author":"R Burchard","year":"2023","unstructured":"Burchard R, Graw JA, Soost C, Schmitt J. Stress shielding effect after total hip arthroplasty varies between combinations of stem design and stiffness-a comparing biomechanical finite element analysis. Int Orthop. 2023. https:\/\/doi.org\/10.1007\/s00264-023-05825-7.","journal-title":"Int Orthop"},{"key":"6389_CR39","doi-asserted-by":"publisher","DOI":"10.3233\/BME-2010-0616","author":"G Bergmann","year":"2010","unstructured":"Bergmann G, Graichen F, Rohlmann A, Bender A, Heinlein B, Duda GN, et al. Realistic loads for testing hip implants. Biomed Mater Eng. 2010. https:\/\/doi.org\/10.3233\/BME-2010-0616.","journal-title":"Biomed Mater Eng"},{"key":"6389_CR40","doi-asserted-by":"publisher","DOI":"10.1007\/s10856-020-06420-7","author":"H Mehboob","year":"2020","unstructured":"Mehboob H, Tarlochan F, Mehboob A, Chang SH, Ramesh S, Harun WSW, et al. A novel design, analysis and 3D printing of Ti-6Al-4V alloy bio-inspired porous femoral stem. J Mater Sci Mater Med. 2020. https:\/\/doi.org\/10.1007\/s10856-020-06420-7.","journal-title":"J Mater Sci Mater Med"},{"key":"6389_CR41","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2017.10.019","author":"B Jette","year":"2018","unstructured":"Jette B, Brailovski V, Simoneau C, Dumas M, Terriault P. Development and in vitro validation of a simplified numerical model for the design of a biomimetic femoral stem. J Mech Behav Biomed Mater. 2018. https:\/\/doi.org\/10.1016\/j.jmbbm.2017.10.019.","journal-title":"J Mech Behav Biomed Mater"},{"key":"6389_CR42","doi-asserted-by":"publisher","DOI":"10.3390\/biomedicines11020427","author":"AT Prakoso","year":"2023","unstructured":"Prakoso AT, Basri H, Adanta D, Yani I, Ammarullah MI, Akbar I, et al. The effect of tortuosity on permeability of porous scaffold. Biomedicines. 2023. https:\/\/doi.org\/10.3390\/biomedicines11020427.","journal-title":"Biomedicines"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-025-06389-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13018-025-06389-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-025-06389-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,14]],"date-time":"2025-11-14T16:42:49Z","timestamp":1763138569000},"score":1,"resource":{"primary":{"URL":"https:\/\/josr-online.biomedcentral.com\/articles\/10.1186\/s13018-025-06389-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,14]]},"references-count":42,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["6389"],"URL":"https:\/\/doi.org\/10.1186\/s13018-025-06389-5","relation":{},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11,14]]},"assertion":[{"value":"9 July 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 October 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 November 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Femur CT scan usage approved by the University of Melbourne Human Ethics Advisory Group (22159).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"1002"}}