{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,12]],"date-time":"2026-06-12T10:38:39Z","timestamp":1781260719767,"version":"3.54.1"},"reference-count":31,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,11,28]],"date-time":"2025-11-28T00:00:00Z","timestamp":1764288000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,11,28]],"date-time":"2025-11-28T00:00:00Z","timestamp":1764288000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100032363","name":"Medacta International","doi-asserted-by":"crossref","id":[{"id":"10.13039\/100032363","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Conventional radiostereometric analysis (RSA) has been used for several decades to assess implant migration in total knee arthroplasty (TKA). More recently, computed tomography\u2013based radiostereometric analysis (CT-RSA) has been introduced as an alternative. Experimental studies have demonstrated acceptable precision for CT-RSA; however, this has not yet been validated in a clinical setting. With the emergence of new alignment philosophies in TKA, migration analysis of femoral components has become increasingly important. A key criticism of CT-RSA has been the higher radiation doses compared with conventional RSA, particularly in longitudinal studies involving repeated CT scans. In this study, we evaluated the precision of CT-RSA for assessing femoral component migration in two TKA designs at two different radiation dose levels. We hypothesized that there would be no clinically relevant difference in precision between the two radiation dose levels.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>We performed a randomized controlled trial of 50 patients using Tritanium and GMK Sphere 3D Metal implants and analysed the precision of the method through double examinations expressed as means with 95% confidence intervals at standard and low-dose levels. The main outcome variable was the difference in mean maximum total point motion. We set the clinical meaningful difference to be more than 0.1\u00a0mm based on existing literature. Secondary outcome variables were the means and standard deviations of the translation and rotation of the implants.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Findings<\/jats:title>\n                    <jats:p>\n                      We found a precision of (mean, standard deviation) 0.20 (0.08) and 0.17\u00a0mm (0.06) for standard and low dose respectively, giving a difference (95% confidence interval) of \u2212\u00a00.03\u00a0mm (\u2212\u00a00.06\u20130.00).\n                      <jats:italic>P<\/jats:italic>\n                      -value was 0.031. Variability ratios were 0.009 for the standard deviation test.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Interpretation<\/jats:title>\n                    <jats:p>In this first clinical study to assess the precision of computed tomography\u2013based radiostereometric analysis for femoral implants in total knee arthroplasty, we found no clinically relevant difference in precision. Our findings confirm that CT-RSA provides sufficient precision in a clinical setting to enable migration analysis of femoral implants in total knee arthroplasty, even when using very low radiation doses.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s13018-025-06517-1","type":"journal-article","created":{"date-parts":[[2025,11,28]],"date-time":"2025-11-28T07:11:14Z","timestamp":1764313874000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Computed tomography-based radiostereometric analysis achieves sufficient precision for femoral implants in total knee arthroplasty: a randomized controlled trial"],"prefix":"10.1186","volume":"20","author":[{"given":"Frank-David","family":"\u00d8hrn","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lars H. W.","family":"Engseth","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Are H.","family":"Pripp","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tommy","family":"Fr\u00f8seth Aae","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anselm","family":"Schulz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Otto","family":"Schnell Husby","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephan M.","family":"R\u00f6hrl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,11,28]]},"reference":[{"issue":"3","key":"6517_CR1","doi-asserted-by":"publisher","first-page":"377","DOI":"10.1302\/0301-620X.77B3.7744919","volume":"77","author":"L Ryd","year":"1995","unstructured":"Ryd L, Albrektsson BE, Carlsson L, Dansgard F, Herberts P, Lindstrand A, et al. Roentgen stereophotogrammetric analysis as a predictor of mechanical loosening of knee prostheses. J Bone Joint Surg British Vol. 1995;77(3):377\u201383.","journal-title":"J Bone Joint Surg British Vol"},{"key":"6517_CR2","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3109\/17453678909154184","volume":"232","author":"G Selvik","year":"1989","unstructured":"Selvik G. Roentgen stereophotogrammetry: a method for the study of the kinematics of the skeletal system. Acta Orthop Scand Suppl. 1989;232:1\u201351.","journal-title":"Acta Orthop Scand Suppl"},{"issue":"4","key":"6517_CR3","doi-asserted-by":"publisher","first-page":"443","DOI":"10.3109\/17453678909149315","volume":"60","author":"LA Brostrom","year":"1989","unstructured":"Brostrom LA, Goldie I, Selvik G. Micromotion of the total knee. Acta Orthop Scand. 1989;60(4):443\u20135.","journal-title":"Acta Orthop Scand"},{"key":"6517_CR4","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1097\/00003086-199203000-00009","volume":"276","author":"L Ryd","year":"1992","unstructured":"Ryd L. Roentgen stereophotogrammetric analysis of prosthetic fixation in the hip and knee joint. Clin Orthop Relat Res. 1992;276:56\u201365.","journal-title":"Clin Orthop Relat Res"},{"issue":"11","key":"6517_CR5","doi-asserted-by":"publisher","first-page":"2330","DOI":"10.1016\/j.jbiomech.2004.09.018","volume":"38","author":"BL Kaptein","year":"2005","unstructured":"Kaptein BL, Valstar ER, Stoel BC, Rozing PM, Reiber JH. A new type of model-based Roentgen stereophotogrammetric analysis for solving the occluded marker problem. J Biomech. 2005;38(11):2330\u20134.","journal-title":"J Biomech"},{"issue":"12","key":"6517_CR6","doi-asserted-by":"publisher","first-page":"3299","DOI":"10.1002\/jor.24111","volume":"36","author":"AN Fraser","year":"2018","unstructured":"Fraser AN, Tsukanaka M, Fjalestad T, Madsen JE, R\u00f6hrl SM. Model-based RSA is suitable for clinical trials on the glenoid component of reverse total shoulder arthroplasty. J Orthop Res. 2018;36(12):3299\u2013307.","journal-title":"J Orthop Res"},{"key":"6517_CR7","doi-asserted-by":"publisher","DOI":"10.1155\/2016\/5909741","volume":"2016","author":"C Brod\u00e9n","year":"2016","unstructured":"Brod\u00e9n C, Olivecrona H, Maguire GQ Jr., Noz ME, Zeleznik MP, Sk\u00f6ldenberg O. Accuracy and precision of three-dimensional low dose CT compared to standard RSA in acetabular cups: an experimental study. BioMed Res Int. 2016;2016:5909741.","journal-title":"BioMed Res Int"},{"issue":"4","key":"6517_CR8","doi-asserted-by":"publisher","first-page":"419","DOI":"10.1080\/17453674.2021.1906082","volume":"92","author":"C Brod\u00e9n","year":"2021","unstructured":"Brod\u00e9n C, Sandberg O, Olivecrona H, Emery R, Sk\u00f6ldenberg O. Precision of CT-based micromotion analysis is comparable to radiostereometry for early migration measurements in cemented acetabular cups. Acta Orthop. 2021;92(4):419\u201323.","journal-title":"Acta Orthop"},{"issue":"6","key":"6517_CR9","doi-asserted-by":"publisher","first-page":"776","DOI":"10.1177\/0284185119882659","volume":"61","author":"C Brod\u00e9n","year":"2020","unstructured":"Brod\u00e9n C, Giles JW, Popat R, Fetherston S, Olivecrona H, Sandberg O, et al. Accuracy and precision of a CT method for assessing migration in shoulder arthroplasty: an experimental study. Acta Radiol. 2020;61(6):776\u201382.","journal-title":"Acta Radiol"},{"key":"6517_CR10","doi-asserted-by":"publisher","first-page":"207","DOI":"10.2340\/17453674.2023.12306","volume":"94","author":"LHW Engseth","year":"2023","unstructured":"Engseth LHW, Schulz A, Pripp AH, R\u00f6hrl SMH, \u00d8hrn FD. CT-based migration analysis is more precise than radiostereometric analysis for tibial implants: a phantom study on a porcine cadaver. Acta Orthop. 2023;94:207\u201314.","journal-title":"Acta Orthop"},{"key":"6517_CR11","doi-asserted-by":"publisher","first-page":"550","DOI":"10.2340\/17453674.2023.24022","volume":"94","author":"FD \u00d8hrn","year":"2023","unstructured":"\u00d8hrn FD, Engseth LHW, Pripp AH, R\u00f6hrl SMH, Schulz A. Dose reduction does not impact the precision of CT-based RSA in tibial implants: a diagnostic accuracy study on precision in a porcine cadaver. Acta Orthop. 2023;94:550\u2013644.","journal-title":"Acta Orthop"},{"key":"6517_CR12","doi-asserted-by":"publisher","first-page":"173","DOI":"10.1302\/0301-620X.107B2.BJJ-2024-0356.R2","volume":"107","author":"LHW Engseth","year":"2025","unstructured":"Engseth LHW, \u00d8hrn FD, Schulz A, R\u00f6hrl SM. CT-based migration analysis in a tibial implant compared to Radiostereometric analysis\u20141-year results of a single-group implant safety study In press. Bone Joint J. 2025;107:173.","journal-title":"Bone Joint J"},{"key":"6517_CR13","doi-asserted-by":"publisher","first-page":"373","DOI":"10.2340\/17453674.2023.15337","volume":"94","author":"OH Sandberg","year":"2023","unstructured":"Sandberg OH, K\u00e4rrholm J, Olivecrona H, R\u00f6hrl SM, Sk\u00f6ldenberg OG, Brod\u00e9n C. Computed tomography-based radiostereometric analysis in orthopedic research: practical guidelines. Acta Orthop. 2023;94:373\u20138.","journal-title":"Acta Orthop"},{"key":"6517_CR14","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiomech.2025.106456","volume":"123","author":"FD \u00d8hrn","year":"2025","unstructured":"\u00d8hrn FD, Engseth LHW, Pripp AH, Schulz A, R\u00f6hrl SMH. Precision of computer tomography based RSA on femoral implants in total knee arthroplasty: a porcine cadaver study. Clin Biomech (Bristol). 2025;123:106456.","journal-title":"Clin Biomech (Bristol)"},{"issue":"1","key":"6517_CR15","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1148\/radiol.14132903","volume":"273","author":"N Saltybaeva","year":"2014","unstructured":"Saltybaeva N, Jafari ME, Hupfer M, Kalender WA. Estimates of effective dose for CT scans of the lower extremities. Radiology. 2014;273(1):153\u20139.","journal-title":"Radiology"},{"key":"6517_CR16","doi-asserted-by":"publisher","first-page":"256","DOI":"10.2340\/17453674.2024.40709","volume":"95","author":"BL Kaptein","year":"2024","unstructured":"Kaptein BL, Pijls B, Koster L, K\u00e4rrholm J, Hull M, Niesen A, et al. Guideline for RSA and CT-RSA implant migration measurements: an update of standardizations and recommendations. Acta Orthop. 2024;95:256\u201367.","journal-title":"Acta Orthop"},{"key":"6517_CR17","first-page":"68","volume":"93","author":"A Christensson","year":"2022","unstructured":"Christensson A, Tveit M, Kesteris U, Flivik G. Similar migration for medial congruent and cruciate-retaining tibial components in an anatomic TKA system: a randomized controlled trial of 60 patients followed with RSA for 2 years. Acta Orthop. 2022;93:68\u201374.","journal-title":"Acta Orthop"},{"issue":"b5","key":"6517_CR18","doi-asserted-by":"publisher","first-page":"855","DOI":"10.1302\/0301-620X.103B5.BJJ-2020-1575.R2","volume":"103","author":"LA Koster","year":"2021","unstructured":"Koster LA, Meinardi JE, Kaptein BL, der Linden-Van V, der Zwaag E, Nelissen R. Two-year RSA migration results of symmetrical and asymmetrical tibial components in total knee arthroplasty: a randomized controlled trial. Bone Joint J. 2021;103(b5):855\u201363.","journal-title":"Bone Joint J"},{"issue":"2","key":"6517_CR19","doi-asserted-by":"publisher","first-page":"148","DOI":"10.1302\/0301-620X.105B2.BJJ-2022-0414.R1","volume":"105-b","author":"LA Koster","year":"2023","unstructured":"Koster LA, Rassir R, Kaptein BL, Sierevelt IN, Schager M, Nelissen R, et al. A randomized controlled trial comparing two-year postoperative femoral and tibial migration of a new and an established cementless rotating platform total knee arthroplasty. Bone Joint J. 2023;105-b(2):148\u201357.","journal-title":"Bone Joint J"},{"issue":"b11","key":"6517_CR20","doi-asserted-by":"publisher","first-page":"1168","DOI":"10.1302\/0301-620X.105B11.BJJ-2022-0839.R4","volume":"105","author":"Y Y\u00fcksel","year":"2023","unstructured":"Y\u00fcksel Y, Koster LA, Kaptein BL, Nelissen R, den Hollander P. No difference in component migration at five years between the cemented cruciate-retaining ATTUNE and PFC-Sigma knee prosthesis: an update of a randomized clinical radiostereometry trial. Bone Joint J. 2023;105(b11):1168\u201376.","journal-title":"Bone Joint J"},{"issue":"3","key":"6517_CR21","doi-asserted-by":"publisher","first-page":"693","DOI":"10.1002\/ksa.12089","volume":"32","author":"AE Niesen","year":"2024","unstructured":"Niesen AE, Tirumalai PA, Howell SM, Hull ML. Risk of tibial baseplate loosening is low in patients following unrestricted kinematic alignment total knee arthroplasty using a cruciate-retaining medial conforming insert: a study using radiostereometric analysis at 2 years. Knee Surg Sports Traumatol Arthrosc. 2024;32(3):693\u2013703.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"8","key":"6517_CR22","doi-asserted-by":"publisher","first-page":"929","DOI":"10.1302\/0301-620X.101B8.BJJ-2018-0755.R3","volume":"101-b","author":"EK Laende","year":"2019","unstructured":"Laende EK, Richardson CG, Dunbar MJ. A randomized controlled trial of tibial component migration with kinematic alignment using patient-specific instrumentation versus mechanical alignment using computer-assisted surgery in total knee arthroplasty. Bone Joint J. 2019;101-b(8):929\u201340.","journal-title":"Bone Joint J"},{"issue":"2","key":"6517_CR23","doi-asserted-by":"publisher","first-page":"488","DOI":"10.1007\/s00167-020-06165-4","volume":"30","author":"P Winnock de Grave","year":"2022","unstructured":"Winnock de Grave P, Luyckx T, Claeys K, Tampere T, Kellens J, M\u00fcller J, et al. Higher satisfaction after total knee arthroplasty using restricted inverse kinematic alignment compared to adjusted mechanical alignment. Knee Surg Sports Traumatol Arthrosc Off J ESSKA. 2022;30(2):488\u201399.","journal-title":"Knee Surg Sports Traumatol Arthrosc Off J ESSKA"},{"issue":"5","key":"6517_CR24","doi-asserted-by":"publisher","first-page":"103305","DOI":"10.1016\/j.otsr.2022.103305","volume":"108","author":"P Winnock de Grave","year":"2022","unstructured":"Winnock de Grave P, Kellens J, Luyckx T, Tampere T, Lacaze F, Claeys K. Inverse kinematic alignment for total knee arthroplasty. Orthop Traumatol Surg Res OTSR. 2022;108(5):103305.","journal-title":"Orthop Traumatol Surg Res OTSR."},{"key":"6517_CR25","doi-asserted-by":"publisher","first-page":"283","DOI":"10.2340\/17453674.2025.43081","volume":"96","author":"\u00d8 Sk\u00e5den","year":"2025","unstructured":"Sk\u00e5den \u00d8, Furnes ON, Lygre SHL, Moldestad IO, Hallan G, Fenstad AM, et al. Radiostereometric measurement of implant migration in robotically assisted vs conventional bi-cruciate stabilized cemented total knee arthroplasty: secondary analysis of a randomized controlled trial. Acta Orthop. 2025;96:283\u20139.","journal-title":"Acta Orthop"},{"issue":"1","key":"6517_CR26","doi-asserted-by":"publisher","first-page":"1238","DOI":"10.1186\/s12885-022-10310-2","volume":"22","author":"CF Cao","year":"2022","unstructured":"Cao CF, Ma KL, Shan H, Liu TF, Zhao SQ, Wan Y, et al. CT scans and cancer risks: a systematic review and dose-response meta-analysis. BMC Cancer. 2022;22(1):1238.","journal-title":"BMC Cancer"},{"issue":"9","key":"6517_CR27","doi-asserted-by":"publisher","first-page":"737","DOI":"10.1302\/2633-1462.29.BJO-2021-0115.R1","volume":"2","author":"FD \u00d8hrn","year":"2021","unstructured":"\u00d8hrn FD, Lian \u00d8B, Tsukanaka M, R\u00f6hrl SM. Early migration of a medially stabilized total knee arthroplasty\u202f: a radiostereometric analysis study up to two years. Bone Joint Open. 2021;2(9):737\u201344.","journal-title":"Bone Joint Open"},{"key":"6517_CR28","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2023.111276","volume":"170","author":"M Selles","year":"2024","unstructured":"Selles M, van Osch JAC, Maas M, Boomsma MF, Wellenberg RHH. Advances in metal artifact reduction in CT images: a review of traditional and novel metal artifact reduction techniques. Eur J Radiol. 2024;170:111276.","journal-title":"Eur J Radiol"},{"key":"6517_CR29","unstructured":"Consort transparent reporting of trials. Available at http:\/\/www.consort-spirit.org [Assessed 22 June 2025]"},{"key":"6517_CR30","unstructured":"NorTrials MU. Avaliable at https:\/\/www.nortrials.no\/news\/nortrials-mu-article\/. [Assessed 22 June 2025]"},{"key":"6517_CR31","unstructured":"International Committee of Medical Journal Editors. Available at https:\/\/www.icmje.org\/ [Assessed 22 June 2025]"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-025-06517-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13018-025-06517-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-025-06517-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,8]],"date-time":"2026-04-08T11:33:12Z","timestamp":1775647992000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s13018-025-06517-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,28]]},"references-count":31,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["6517"],"URL":"https:\/\/doi.org\/10.1186\/s13018-025-06517-1","relation":{},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11,28]]},"assertion":[{"value":"18 September 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 November 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 November 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study has service user involvement, as a service user, who was not a patient in the study, was appointed to participate in the conceptualization of the study. This person also participated in meetings and phone calls during the study to ensure service user involvement. The study was approved by the Central Norway Regional Ethics Committee (ID number 520246) and the data access committee of M\u00f8re and Romsdal Hospital Trust. It was registered at Clinicaltrials.gov (ID NCT05651009) and adheres to the CONSORT statement [\n                      \n                      ]. All patients received oral and written information and provided signed consent prior to inclusion in the study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"The authors declare no competing interests.BMI, body mass index; HKA, hip knee ankle angle; CI, confidence interval; N, number.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"1043"}}