{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,10]],"date-time":"2026-02-10T07:55:13Z","timestamp":1770710113879,"version":"3.49.0"},"reference-count":37,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,1,12]],"date-time":"2026-01-12T00:00:00Z","timestamp":1768176000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,2,9]],"date-time":"2026-02-09T00:00:00Z","timestamp":1770595200000},"content-version":"vor","delay-in-days":28,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"DOI":"10.13039\/501100017594","name":"Medical\u00a0and\u00a0Health\u00a0Science and Technology Project of Zhejiang Province","doi-asserted-by":"crossref","award":["2024KY381"],"award-info":[{"award-number":["2024KY381"]}],"id":[{"id":"10.13039\/501100017594","id-type":"DOI","asserted-by":"crossref"}]},{"name":"Funded by Ningbo Clinical Research Center for Orthopedics, Sports Medicine &\u00a0Rehabilitation","award":["2024L004"],"award-info":[{"award-number":["2024L004"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"DOI":"10.1186\/s13018-025-06623-0","type":"journal-article","created":{"date-parts":[[2026,1,12]],"date-time":"2026-01-12T06:44:01Z","timestamp":1768200241000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["The design and biomechanical study of the 3D-printed implanted cervical vertebral cage"],"prefix":"10.1186","volume":"21","author":[{"given":"Ruoheng","family":"Yin","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Weiyu","family":"Jiang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Junhui","family":"Chu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yunlin","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xudong","family":"Hu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Weihu","family":"Ma","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2026,1,12]]},"reference":[{"issue":"3","key":"6623_CR1","doi-asserted-by":"publisher","first-page":"607","DOI":"10.2106\/00004623-195840030-00009","volume":"40-a","author":"GW Smith","year":"1958","unstructured":"Smith GW, Robinson RA. The treatment of certain cervical-spine disorders by anterior removal of the intervertebral disc and interbody fusion. J Bone Joint Surg Am. 1958;40-a(3):607\u201324.","journal-title":"J Bone Joint Surg Am"},{"issue":"6","key":"6623_CR2","doi-asserted-by":"publisher","first-page":"602","DOI":"10.3171\/jns.1958.15.6.0602","volume":"15","author":"RB Cloward","year":"1958","unstructured":"Cloward RB. The anterior approach for removal of ruptured cervical disks. J Neurosurg. 1958;15(6):602\u201317.","journal-title":"J Neurosurg"},{"issue":"49","key":"6623_CR3","doi-asserted-by":"publisher","DOI":"10.1097\/MD.0000000000005437","volume":"95","author":"T Wang","year":"2016","unstructured":"Wang T, Wang H, Liu S, An HD, Liu H, Ding WY. Anterior cervical discectomy and fusion versus anterior cervical corpectomy and fusion in multilevel cervical spondylotic myelopathy: a meta-analysis. Medicine (Baltimore). 2016;95(49):e5437.","journal-title":"Medicine (Baltimore)"},{"key":"6623_CR4","doi-asserted-by":"publisher","DOI":"10.3389\/fsurg.2022.1021643","volume":"9","author":"X Tian","year":"2022","unstructured":"Tian X, Zhao H, Han FY, et al. Treatment of three-level cervical spondylotic myelopathy using ACDF or a combination of ACDF and ACCF. Front Surg. 2022;9:1021643.","journal-title":"Front Surg"},{"issue":"1","key":"6623_CR5","doi-asserted-by":"publisher","first-page":"256","DOI":"10.1186\/s13018-025-05654-x","volume":"20","author":"C Sever","year":"2025","unstructured":"Sever C, Kilinc BE, Akpolat AO, Bozkaya T, Kurtan A, Misir A. A retrospective comparative analysis of anterior cervical discectomy and fusion using stand-alone titanium cage versus cage and plate fixation in two-level cervical disc herniation. J Orthop Surg Res. 2025;20(1):256.","journal-title":"J Orthop Surg Res"},{"issue":"1","key":"6623_CR6","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1272\/jnms.79.37","volume":"79","author":"K Kim","year":"2012","unstructured":"Kim K, Isu T, Morimoto D, Sugawara A, Kobayashi S, Teramoto A. Cervical anterior fusion with the Williams-Isu method: clinical review. J Nippon Med Sch. 2012;79(1):37\u201345.","journal-title":"J Nippon Med Sch"},{"issue":"1","key":"6623_CR7","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1272\/jnms.82.50","volume":"82","author":"K Kogure","year":"2015","unstructured":"Kogure K, Isu T, Node Y, Tamaki T, Kim K, Morimoto D, et al. Technical arrangement of the Williams-Isu method for anterior cervical discectomy and fusion. J Nippon Med Sch. 2015;82(1):50\u20133.","journal-title":"J Nippon Med Sch"},{"issue":"1","key":"6623_CR8","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1186\/s13018-016-0449-z","volume":"11","author":"T Lei","year":"2016","unstructured":"Lei T, Wang H, Tong T, Ma Q, Wang L, Shen Y. Enlarged anterior cervical diskectomy and fusion in the treatment of severe localised ossification of the posterior longitudinal ligament. J Orthop Surg Res. 2016;11(1):129.","journal-title":"J Orthop Surg Res"},{"issue":"6","key":"6623_CR9","doi-asserted-by":"publisher","first-page":"2110","DOI":"10.1007\/s00586-023-07691-8","volume":"32","author":"C Qiu","year":"2023","unstructured":"Qiu C, Zhao Y, Wang L, et al. Anterior cervical tunnectomy and fusion (ACTF): a novel technique for cervical canal decompression. Eur Spine J. 2023;32(6):2110\u20139.","journal-title":"Eur Spine J"},{"issue":"1","key":"6623_CR10","doi-asserted-by":"publisher","first-page":"896","DOI":"10.1186\/s13018-024-05339-x","volume":"19","author":"R Yu","year":"2024","unstructured":"Yu R, Yuan X, Huang K, Wu T, Wang H, Ding C, et al. Impact of titanium mesh cage slotting width on anterior cervical corpectomy and fusion for compression cervical spondylosis with MRI T2WI hyperintensity: a one-year follow-up study. J Orthop Surg Res. 2024;19(1):896.","journal-title":"J Orthop Surg Res"},{"issue":"1","key":"6623_CR11","doi-asserted-by":"publisher","DOI":"10.1002\/jsp2.1138","volume":"4","author":"JJ Costi","year":"2021","unstructured":"Costi JJ, Ledet EH, O\u2019Connell GD. Spine biomechanical testing methodologies: the controversy of consensus vs scientific evidence. JOR Spine. 2021;4(1):e1138.","journal-title":"JOR Spine"},{"issue":"1","key":"6623_CR12","doi-asserted-by":"publisher","first-page":"364","DOI":"10.1186\/s13018-024-04729-5","volume":"19","author":"P Zhang","year":"2024","unstructured":"Zhang P, Zheng H, Luo J, Xu J. Comparative efficacy of zero-profile implant and conventional cage-plate implant in the treatment of single-level degenerative cervical spondylosis: a systematic review and meta-analysis. J Orthop Surg Res. 2024;19(1):364.","journal-title":"J Orthop Surg Res"},{"issue":"1","key":"6623_CR13","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1186\/s13018-024-04539-9","volume":"19","author":"HH Zhao","year":"2024","unstructured":"Zhao HH, Xu HW, Wang SJ, Hu T, Wu DS. Anterior cervical discectomy and fusion with a zero-profile VA spacer device: a clinical and radiological study with two-year follow-up. J Orthop Surg Res. 2024;19(1):51.","journal-title":"J Orthop Surg Res"},{"issue":"1","key":"6623_CR14","doi-asserted-by":"publisher","first-page":"851","DOI":"10.1186\/s13018-025-06286-x","volume":"20","author":"B Zheng","year":"2025","unstructured":"Zheng B, Yu P, Ma K, Zhu Z, Liang Y, Liu H. Radiomics-based machine learning model integrating preoperative vertebral computed tomography and clinical features to predict cage subsidence after single-level anterior cervical discectomy and fusion with a zero-profile anchored spacer. J Orthop Surg Res. 2025;20(1):851.","journal-title":"J Orthop Surg Res"},{"issue":"3","key":"6623_CR15","first-page":"273","volume":"33","author":"Can Xu","year":"2018","unstructured":"Xu Can, Li Mingqing, Wang Chenggong, Li Kanghua, Liu Hua. Research progress on multilevel structure and toughening mechanism of cortical bone. Chin J Biomech. 2018;33(3):273\u20139.","journal-title":"Chin J Biomech"},{"issue":"1","key":"6623_CR16","doi-asserted-by":"publisher","first-page":"436","DOI":"10.1186\/s13018-025-05843-8","volume":"20","author":"J Wang","year":"2025","unstructured":"Wang J, Wang Z, Feng Y, et al. Forearm bone mineral density predicts subsidence of titanium mesh cage after anterior cervical corpectomy and fusion in patients with cervical spondylosis. J Orthop Surg Res. 2025;20(1):436.","journal-title":"J Orthop Surg Res"},{"issue":"8","key":"6623_CR17","doi-asserted-by":"publisher","first-page":"951","DOI":"10.1097\/00007632-200104150-00021","volume":"26","author":"TH Lim","year":"2001","unstructured":"Lim TH, Kwon H, Jeon CH, et al. Effect of endplate conditions and bone mineral density on the compressive strength of the graft-endplate interface in anterior cervical spine fusion. Spine (Phila Pa 1976). 2001;26(8):951\u20136.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"8","key":"6623_CR18","doi-asserted-by":"publisher","first-page":"1011","DOI":"10.1097\/00007632-199306150-00010","volume":"18","author":"RF Closkey","year":"1993","unstructured":"Closkey RF, Parsons JR, Lee CK, Blacksin MF, Zimmerman MC. Mechanics of interbody spinal fusion. Analysis of critical bone graft area. Spine (Phila Pa 1976). 1993;18(8):1011\u20135.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"9","key":"6623_CR19","doi-asserted-by":"publisher","first-page":"1077","DOI":"10.1097\/00007632-200005010-00007","volume":"25","author":"T Steffen","year":"2000","unstructured":"Steffen T, Tsantrizos A, Aebi M. Effect of implant design and endplate preparation on the compressive strength of interbody fusion constructs. Spine (Phila Pa 1976). 2000;25(9):1077\u201384.","journal-title":"Spine (Phila Pa 1976)"},{"key":"6623_CR20","doi-asserted-by":"publisher","first-page":"332","DOI":"10.1016\/j.jmbbm.2015.05.015","volume":"49","author":"AR Knutsen","year":"2015","unstructured":"Knutsen AR, Borkowski SL, Ebramzadeh E, Flanagan CL, Hollister SJ, Sangiorgio SN. Static and dynamic fatigue behavior of topology designed and conventional 3D printed bioresorbable PCL cervical interbody fusion devices. J Mech Behav Biomed Mater. 2015;49:332\u201342.","journal-title":"J Mech Behav Biomed Mater"},{"issue":"1","key":"6623_CR21","doi-asserted-by":"publisher","first-page":"245","DOI":"10.1186\/s13018-024-04716-w","volume":"19","author":"Y Tuo","year":"2024","unstructured":"Tuo Y, Lin K, Yang J, Wang S, Abudouaini H. Preoperative MRI-based endplate quality: a novel tool for predicting cage subsidence after anterior cervical spine surgery. J Orthop Surg Res. 2024;19(1):245.","journal-title":"J Orthop Surg Res"},{"issue":"1","key":"6623_CR22","doi-asserted-by":"publisher","first-page":"569","DOI":"10.1186\/s13018-024-05049-4","volume":"19","author":"Q Jian","year":"2024","unstructured":"Jian Q, Qin S, Hou Z, Zhao X, Liang C, Fan T. Individualized C1-2 intra-articular three-dimensional printed porous titanium alloy cage for craniovertebral deformity. J Orthop Surg Res. 2024;19(1):569.","journal-title":"J Orthop Surg Res"},{"issue":"7","key":"6623_CR23","doi-asserted-by":"publisher","first-page":"1386","DOI":"10.1002\/jbm.a.36652","volume":"107","author":"P Li","year":"2019","unstructured":"Li P, Jiang W, Yan J, et al. A novel 3D printed cage with microporous structure and in vivo fusion function. J Biomed Mater Res A. 2019;107(7):1386\u201392.","journal-title":"J Biomed Mater Res A"},{"issue":"12","key":"6623_CR24","first-page":"1491","volume":"33","author":"Y Yang","year":"2019","unstructured":"Yang Y, Liu H, Wu T, Hu L, Chen L, Rong X. l. Applied anatomy research of the uncovertebral joint for design of uncovertebral joint fusion cage. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2019;33(12):1491\u20137.","journal-title":"Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi"},{"issue":"2","key":"6623_CR25","doi-asserted-by":"publisher","first-page":"148","DOI":"10.1007\/s005860050045","volume":"7","author":"HJ Wilke","year":"1998","unstructured":"Wilke HJ, Wenger K, Claes L. Testing criteria for spinal implants: recommendations for the standardization of in vitro stability testing of spinal implants. Eur Spine J. 1998;7(2):148\u201354.","journal-title":"Eur Spine J"},{"key":"6623_CR26","doi-asserted-by":"crossref","unstructured":"Gonzalez-Blohm SA, Doulgeris JJ, Lee WE, 3rd Shea TM, Aghayev K, Vrionis FD. The current testing protocols for biomechanical evaluation of lumbar spinal implants in laboratory setting: a review of the literature. Biomed Res Int. 2015;2015:506181.","DOI":"10.1155\/2015\/506181"},{"issue":"1","key":"6623_CR27","doi-asserted-by":"publisher","first-page":"106","DOI":"10.1186\/s13018-024-04567-5","volume":"19","author":"H Chen","year":"2024","unstructured":"Chen H, Sun H, Cao L, Xia H, Tu Q. Biomechanical evaluation of the novel assembled internal fixed system in C2-C3 anterior cervical discectomy and fusion: a finite element analysis. J Orthop Surg Res. 2024;19(1):106.","journal-title":"J Orthop Surg Res"},{"issue":"1","key":"6623_CR28","doi-asserted-by":"publisher","first-page":"142","DOI":"10.1186\/s13018-024-04629-8","volume":"19","author":"TT Chung","year":"2024","unstructured":"Chung TT, Hueng DY, Lin SC. Biomechanical comparison of static and dynamic cervical plates in terms of the bone fusion, tissue degeneration, and implant behavior. J Orthop Surg Res. 2024;19(1):142.","journal-title":"J Orthop Surg Res"},{"issue":"1","key":"6623_CR29","doi-asserted-by":"publisher","DOI":"10.1186\/s13018-025-05918-6","volume":"20","author":"XH Lian","year":"2025","unstructured":"Lian XH, Sun WJ, Xue HH, Chen YF, Zeng ZF, Xue JL. Biomechanical comparison of multiple zero-profile systems in anterior cervical discectomy and fusion: a finite element analysis. J Orthop Surg Res. 2025;20(1):511.","journal-title":"J Orthop Surg Res"},{"issue":"1","key":"6623_CR30","doi-asserted-by":"publisher","first-page":"854","DOI":"10.1186\/s13018-025-06237-6","volume":"20","author":"H Yang","year":"2025","unstructured":"Yang H, Wang Y, Miao J, et al. Analysis of the anti-subsidence mechanical properties of novel 3D-printed titanium cages compared to conventional titanium cages. J Orthop Surg Res. 2025;20(1):854.","journal-title":"J Orthop Surg Res"},{"issue":"9","key":"6623_CR31","doi-asserted-by":"publisher","first-page":"1028","DOI":"10.1097\/00007632-200105010-00008","volume":"26","author":"F Kandziora","year":"2001","unstructured":"Kandziora F, Pflugmacher R, Scholz M, Schnake K, Lucke M, Schr\u00f6der R, et al. Comparison between sheep and human cervical spines: an anatomic, radiographic, bone mineral density, and biomechanical study. Spine (Phila Pa 1976). 2001;26(9):1028\u201337.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"3","key":"6623_CR32","doi-asserted-by":"publisher","first-page":"607","DOI":"10.1007\/s10237-018-1104-x","volume":"18","author":"L Wang","year":"2019","unstructured":"Wang L, Wang Y, Shi L, et al. Can the sheep model fully represent the human model for the functional evaluation of cervical interbody fusion cages? Biomech Model Mechanobiol. 2019;18(3):607\u201316.","journal-title":"Biomech Model Mechanobiol"},{"issue":"5","key":"6623_CR33","doi-asserted-by":"publisher","first-page":"614","DOI":"10.3171\/2013.8.SPINE13136","volume":"19","author":"H Yoshihara","year":"2013","unstructured":"Yoshihara H, Passias PG, Errico TJ. Screw-related complications in the subaxial cervical spine with the use of lateral mass versus cervical pedicle screws: a systematic review. J Neurosurg Spine. 2013;19(5):614\u201323.","journal-title":"J Neurosurg Spine"},{"key":"6623_CR34","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1016\/j.jbiomech.2017.01.032","volume":"54","author":"JH Peck","year":"2017","unstructured":"Peck JH, Sing DC, Nagaraja S, Peck DG, Lotz JC, Dmitriev AE. Mechanical performance of cervical intervertebral body fusion devices: a systematic analysis of data submitted to the food and drug administration. J Biomech. 2017;54:26\u201332.","journal-title":"J Biomech"},{"issue":"5","key":"6623_CR35","doi-asserted-by":"publisher","DOI":"10.1115\/1.4036312","volume":"139","author":"LS Chatham","year":"2017","unstructured":"Chatham LS, Patel VV, Yakacki CM, Dana Carpenter R. Interbody spacer material properties and design conformity for reducing subsidence during lumbar interbody fusion. J Biomech Eng. 2017;139(5):0510051-8.","journal-title":"J Biomech Eng"},{"issue":"17","key":"6623_CR36","doi-asserted-by":"publisher","first-page":"1852","DOI":"10.1097\/BRS.0b013e31811ece5a","volume":"32","author":"CC Cheng","year":"2007","unstructured":"Cheng CC, Ordway NR, Zhang X, Lu YM, Fang H, Fayyazi AH. Loss of cervical endplate integrity following minimal surface preparation. Spine (Phila Pa 1976). 2007;32(17):1852\u20135.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"26","key":"6623_CR37","doi-asserted-by":"publisher","first-page":"2970","DOI":"10.1097\/BRS.0b013e31815cde16","volume":"32","author":"EC Clarke","year":"2007","unstructured":"Clarke EC, Appleyard RC, Bilston LE. Immature sheep spines are more flexible than mature spines: an in vitro biomechanical study. Spine (Phila Pa 1976). 2007;32(26):2970\u20139.","journal-title":"Spine (Phila Pa 1976)"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13018-025-06623-0","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-025-06623-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-025-06623-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,9]],"date-time":"2026-02-09T13:18:33Z","timestamp":1770643113000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s13018-025-06623-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,12]]},"references-count":37,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["6623"],"URL":"https:\/\/doi.org\/10.1186\/s13018-025-06623-0","relation":{},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,12]]},"assertion":[{"value":"24 October 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 December 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 January 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study had been approved by IRB of The NINGBO NO.6 hospital(Approval NO.2023-19K).All experimental goat specimens were provided by Shaoxing Shangyu Zhou Laoda Cattle and Sheep Slaughter Co., Ltd.And consent to use the animal specimens in this study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable. No human participants were involved.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"104"}}