{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,6]],"date-time":"2026-11-06T15:49:50Z","timestamp":1793980190982,"version":"4.8.0"},"reference-count":94,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,3,24]],"date-time":"2026-03-24T00:00:00Z","timestamp":1774310400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,4,9]],"date-time":"2026-04-09T00:00:00Z","timestamp":1775692800000},"content-version":"vor","delay-in-days":16,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Universit\u00e4tsklinikum Halle (Saale)"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Introduction<\/jats:title>\n                    <jats:p>Medial pivot total knee arthroplasty (TKA) has been developed to reproduce physiological tibiofemoral kinematics and improve patient satisfaction. The choice of alignment philosophy, whether mechanical alignment (MA) or kinematic alignment (KA), may influence outcomes in this context, yet evidence remains conflicting. This systematic review and meta-analysis aimed to compare clinical, functional, and radiological outcomes as well as revision rates between MA and KA in medial pivot TKA.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A systematic search was conducted in PubMed, Web of Science, Embase, and Google Scholar in August 2025, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Comparative and non-comparative clinical studies reporting outcomes of medial pivot TKA performed with either MA or KA were included. Data extracted included Knee Society Score (KSS), KSS functional subscale (KSS-F), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Oxford Knee Score (OKS), Forgotten Joint Score (FJS), Knee Injury and Osteoarthritis Outcome Score (KOOS), Range of Motion (ROM), and revision rates. Meta-analyses were performed when at least two studies reported comparable data.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Thirty-five studies comprising 5,216 patients were included, of whom 4,325 underwent medial pivot TKA with MA and 891 with KA. The dataset consisted of 12 comparative studies and 22 single-arm cohorts. Mean follow-up across studies was 62.4\u00a0months (range 12\u2013180). At baseline, the two groups were comparable in age, sex distribution, and most outcome measures, although the KA group presented with a higher BMI and greater ROM. At final follow-up, there were no qualitatively significant differences in KSS, OKS, WOMAC, KOOS, or FJS between groups. The KA group achieved a statistically greater ROM (mean difference 4.9\u00b0, p\u2009=\u20090.01), and pooled analysis demonstrated a higher FJS (MD 8.36, 95% CI 4.18 to 12.55, p\u2009&lt;\u20090.0001). However, the magnitude of these differences did not exceed the minimal clinically important difference. Revision rates and complication profiles were comparable between alignment strategies, although follow-up timepoints varied across studies.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Both kinematic and mechanical alignment in medial pivot TKA yielded reliable improvements in clinical and functional outcomes, with only minor differences in motion and joint awareness that did not reach thresholds of clinical relevance. Surgical decision-making should therefore prioritise intraoperative soft tissue balance, implant-specific design, and surgeon expertise rather than the expectation of meaningful superiority of one alignment philosophy over the other.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s13018-026-06668-9","type":"journal-article","created":{"date-parts":[[2026,3,24]],"date-time":"2026-03-24T13:16:44Z","timestamp":1774358204000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Alignment strategy does not confer clinically meaningful advantages in medial pivot total knee arthroplasty: a systematic review and meta-analysis"],"prefix":"10.1186","volume":"21","author":[{"given":"Filippo","family":"Migliorini","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marco","family":"Pilone","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luise","family":"Sch\u00e4fer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Raju","family":"Vaishya","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giorgio","family":"Moretti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Memminger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicola","family":"Maffulli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,3,24]]},"reference":[{"issue":"1","key":"6668_CR1","doi-asserted-by":"publisher","DOI":"10.1186\/s10195-024-00798-8","volume":"25","author":"DJ Haslhofer","year":"2024","unstructured":"Haslhofer DJ, Anelli-Monti V, Hausbrandt P, Kammerlander C, Klasan A. No difference in surgical time and total theatre time between robotically assisted and computer assisted total knee arthroplasty. J Orthop Traumatol. 2024;25(1):52. https:\/\/doi.org\/10.1186\/s10195-024-00798-8.","journal-title":"J Orthop Traumatol"},{"issue":"1","key":"6668_CR2","doi-asserted-by":"publisher","DOI":"10.1186\/s10195-024-00775-1","volume":"25","author":"C Hamoudi","year":"2024","unstructured":"Hamoudi C, Hamon M, Reiter-Schatz A, Debordes PA, Gaudias J, Ronde-Oustau C, et al. Cement loaded with high-dose gentamicin and clindamycin does not reduce the risk of subsequent infection after aseptic total hip or knee revision arthroplasty: a preliminary study. J Orthop Traumatol. 2024;25(1):37. https:\/\/doi.org\/10.1186\/s10195-024-00775-1.","journal-title":"J Orthop Traumatol"},{"issue":"1","key":"6668_CR3","doi-asserted-by":"publisher","DOI":"10.1186\/s10195-024-00765-3","volume":"25","author":"G Piovan","year":"2024","unstructured":"Piovan G, De Berardinis L, Screpis D, Senarighi M, Povegliano L, Natali S, et al. Metal-backed or all-poly tibial components: which are better for medial unicompartmental knee arthroplasty? A propensity-score-matching retrospective study at the 5-year follow-up. J Orthop Traumatol. 2024;25(1):24. https:\/\/doi.org\/10.1186\/s10195-024-00765-3.","journal-title":"J Orthop Traumatol"},{"key":"6668_CR4","doi-asserted-by":"publisher","first-page":"258","DOI":"10.1016\/j.knee.2025.05.020","volume":"56","author":"M Innocenti","year":"2025","unstructured":"Innocenti M, Leggieri F, Civinini A, Martin Cocilova FN, Stimolo D, Civinini R. Long-term outcomes, satisfaction, and survival rates of a medial pivot knee design. Knee. 2025;56:258\u201366. https:\/\/doi.org\/10.1016\/j.knee.2025.05.020.","journal-title":"Knee"},{"issue":"6","key":"6668_CR5","doi-asserted-by":"publisher","first-page":"1778","DOI":"10.1016\/j.knee.2020.09.009","volume":"27","author":"H Ueyama","year":"2020","unstructured":"Ueyama H, Kanemoto N, Minoda Y, Yamamoto N, Taniguchi Y, Nakamura H. Long-term clinical outcomes of medial pivot total knee arthroplasty for Asian patients: a mean 10-year follow-up study. Knee. 2020;27(6):1778\u201386. https:\/\/doi.org\/10.1016\/j.knee.2020.09.009.","journal-title":"Knee"},{"issue":"2","key":"6668_CR6","doi-asserted-by":"publisher","first-page":"422","DOI":"10.1016\/j.arth.2019.09.021","volume":"35","author":"SR French","year":"2020","unstructured":"French SR, Munir S, Brighton R. A single surgeon series comparing the outcomes of a cruciate retaining and medially stabilized total knee arthroplasty using kinematic alignment principles. J Arthroplasty. 2020;35(2):422\u20138. https:\/\/doi.org\/10.1016\/j.arth.2019.09.021.","journal-title":"J Arthroplasty"},{"issue":"6","key":"6668_CR7","doi-asserted-by":"publisher","first-page":"522","DOI":"10.1016\/j.knee.2014.11.011","volume":"22","author":"A Shimmin","year":"2015","unstructured":"Shimmin A, Martinez-Martos S, Owens J, Iorgulescu AD, Banks S. Fluoroscopic motion study confirming the stability of a medial pivot design total knee arthroplasty. Knee. 2015;22(6):522\u20136. https:\/\/doi.org\/10.1016\/j.knee.2014.11.011.","journal-title":"Knee"},{"issue":"3","key":"6668_CR8","doi-asserted-by":"publisher","DOI":"10.1002\/jeo2.70358","volume":"12","author":"PF Indelli","year":"2025","unstructured":"Indelli PF, Violante B, Skowronek P, Ostojic M, Bouguennec N, Aloisi G, et al. The combination of a medial pivot design with kinematic alignment principles in total knee arthroplasty can ensure a closer to normal knee kinematics than combining mechanical alignment and more traditional implant designs: an umbrella review. J Exp Orthop. 2025;12(3):e70358. https:\/\/doi.org\/10.1002\/jeo2.70358.","journal-title":"J Exp Orthop"},{"issue":"2","key":"6668_CR9","doi-asserted-by":"publisher","first-page":"447","DOI":"10.1016\/j.knee.2017.01.008","volume":"24","author":"GA Macheras","year":"2017","unstructured":"Macheras GA, Galanakos SP, Lepetsos P, Anastasopoulos PP, Papadakis SA. A long term clinical outcome of the Medial Pivot Knee Arthroplasty System. Knee. 2017;24(2):447\u201353. https:\/\/doi.org\/10.1016\/j.knee.2017.01.008.","journal-title":"Knee"},{"issue":"1","key":"6668_CR10","doi-asserted-by":"publisher","DOI":"10.1186\/s13018-025-06369-9","volume":"20","author":"G Pipino","year":"2025","unstructured":"Pipino G, Anzano F, Moretti EC, Borghi R, Vaccarisi DC, Caldora P, et al. Clinical outcomes of intramedullary tibial guides in total knee arthroplasty: experience from a single-centre cohort. J Orthop Surg Res. 2025;20(1):918. https:\/\/doi.org\/10.1186\/s13018-025-06369-9.","journal-title":"J Orthop Surg Res"},{"key":"6668_CR11","doi-asserted-by":"publisher","DOI":"10.1007\/s00132-025-04711-x","author":"F Migliorini","year":"2025","unstructured":"Migliorini F, Schafer L, Schneider J, Nobili AM, Kammer D, Bell A. Improved accuracy of functional alignment restoration with robotic-assisted total knee arthroplasty\u202f: A quasi-randomized controlled trial. Orthopadie (Heidelb). 2025. https:\/\/doi.org\/10.1007\/s00132-025-04711-x.","journal-title":"Orthopadie (Heidelb)"},{"issue":"9","key":"6668_CR12","doi-asserted-by":"publisher","first-page":"1245","DOI":"10.1007\/s00402-020-03478-4","volume":"140","author":"F Migliorini","year":"2020","unstructured":"Migliorini F, Eschweiler J, Mansy YE, Quack V, Schenker H, Tingart M, et al. Gap balancing versus measured resection for primary total knee arthroplasty: a meta-analysis study. Arch Orthop Trauma Surg. 2020;140(9):1245\u201353. https:\/\/doi.org\/10.1007\/s00402-020-03478-4.","journal-title":"Arch Orthop Trauma Surg"},{"issue":"4","key":"6668_CR13","doi-asserted-by":"publisher","first-page":"937","DOI":"10.1007\/s00590-019-02370-1","volume":"29","author":"F Migliorini","year":"2019","unstructured":"Migliorini F, Eschweiler J, Tingart M, Rath B. Posterior-stabilized versus cruciate-retained implants for total knee arthroplasty: a meta-analysis of clinical trials. Eur J Orthop Surg Traumatol. 2019;29(4):937\u201346. https:\/\/doi.org\/10.1007\/s00590-019-02370-1.","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"6668_CR14","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1016\/j.jor.2025.03.046","volume":"70","author":"C Fernandez","year":"2025","unstructured":"Fernandez C, Brownell M, Eom R, Nwankwo T, Gulati J, Bellaire CP, et al. Patellar alignment compared between kinematic and mechanical unicompartmental knee arthroplasties. J Orthop. 2025;70:77\u201381. https:\/\/doi.org\/10.1016\/j.jor.2025.03.046.","journal-title":"J Orthop"},{"issue":"7","key":"6668_CR15","doi-asserted-by":"publisher","first-page":"1047","DOI":"10.1016\/j.otsr.2017.07.010","volume":"103","author":"C Riviere","year":"2017","unstructured":"Riviere C, Iranpour F, Auvinet E, Howell S, Vendittoli PA, Cobb J, et al. Alignment options for total knee arthroplasty: A systematic review. Orthop Traumatol Surg Res. 2017;103(7):1047\u201356. https:\/\/doi.org\/10.1016\/j.otsr.2017.07.010.","journal-title":"Orthop Traumatol Surg Res"},{"key":"6668_CR16","doi-asserted-by":"publisher","DOI":"10.1007\/s00132-025-04709-5","author":"F Migliorini","year":"2025","unstructured":"Migliorini F, Schafer L, Schneider J, Nobili AM, Kammer D, Maffulli N, et al. Perioperative comparison between robotic-assisted and freehand total knee arthroplasty\u202f: A quasi-randomized controlled trial. Orthopadie (Heidelb). 2025. https:\/\/doi.org\/10.1007\/s00132-025-04709-5.","journal-title":"Orthopadie (Heidelb)"},{"issue":"1","key":"6668_CR17","doi-asserted-by":"publisher","first-page":"212","DOI":"10.1007\/s00402-025-05835-7","volume":"145","author":"F Migliorini","year":"2025","unstructured":"Migliorini F, Maffulli N, Pilone M, Schafer L, Ullmann D, Huber T, et al. Mechanical versus kinematic alignment for total knee arthroplasty: a meta-analysis. Arch Orthop Trauma Surg. 2025;145(1):212. https:\/\/doi.org\/10.1007\/s00402-025-05835-7.","journal-title":"Arch Orthop Trauma Surg"},{"issue":"12","key":"6668_CR18","doi-asserted-by":"publisher","first-page":"7153","DOI":"10.1007\/s00402-023-05008-4","volume":"143","author":"J Koettnitz","year":"2023","unstructured":"Koettnitz J, Tigges J, Migliorini F, Peterlein CD, Gotze C. Analysis of gender differences with traditional posterior stabilized versus kinematic designs in total knee arthroplasty. Arch Orthop Trauma Surg. 2023;143(12):7153\u20138. https:\/\/doi.org\/10.1007\/s00402-023-05008-4.","journal-title":"Arch Orthop Trauma Surg"},{"issue":"5","key":"6668_CR19","doi-asserted-by":"publisher","first-page":"1410","DOI":"10.1007\/s00167-018-5174-1","volume":"27","author":"W Blakeney","year":"2019","unstructured":"Blakeney W, Clement J, Desmeules F, Hagemeister N, Riviere C, Vendittoli PA. Kinematic alignment in total knee arthroplasty better reproduces normal gait than mechanical alignment. Knee Surg Sports Traumatol Arthrosc. 2019;27(5):1410\u20137. https:\/\/doi.org\/10.1007\/s00167-018-5174-1.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"5","key":"6668_CR20","doi-asserted-by":"publisher","first-page":"1275","DOI":"10.1002\/ksa.12143","volume":"32","author":"M Ettinger","year":"2024","unstructured":"Ettinger M, Tuecking LR, Savov P, Windhagen H. Higher satisfaction and function scores in restricted kinematic alignment versus mechanical alignment with medial pivot design total knee arthroplasty: A prospective randomised controlled trial. Knee Surg Sports Traumatol Arthrosc. 2024;32(5):1275\u201386. https:\/\/doi.org\/10.1002\/ksa.12143.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"5","key":"6668_CR21","doi-asserted-by":"publisher","first-page":"921","DOI":"10.1016\/j.otsr.2020.04.005","volume":"106","author":"DV Jeremic","year":"2020","unstructured":"Jeremic DV, Massouh WM, Sivaloganathan S, Rosali AR, Haaker RG, Riviere C. Short-term follow-up of kinematically vs. mechanically aligned total knee arthroplasty with medial pivot components: a case-control study. Orthop Traumatol Surg Res. 2020;106(5):921\u20137. https:\/\/doi.org\/10.1016\/j.otsr.2020.04.005.","journal-title":"Orthop Traumatol Surg Res"},{"key":"6668_CR22","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1016\/j.artd.2021.10.004","volume":"13","author":"K Kaneda","year":"2022","unstructured":"Kaneda K, Niki Y, Kuroyanagi Y, Kobayashi S, Harato K, Iwama Y, et al. Kinematically aligned total knee arthroplasty using medial pivot knee prosthesis enhances medial pivot motion: a comparative kinematic study with mechanically aligned total knee arthroplasty. Arthroplast Today. 2022;13:24\u20138. https:\/\/doi.org\/10.1016\/j.artd.2021.10.004.","journal-title":"Arthroplast Today"},{"issue":"1","key":"6668_CR23","doi-asserted-by":"publisher","DOI":"10.1186\/s10195-024-00762-6","volume":"25","author":"AA Dewidar","year":"2024","unstructured":"Dewidar AA, Mesregah MK, Mesriga MM, El-Behiry AM. Autogenous structural bone graft reconstruction of >\/= 10-mm-deep uncontained medial proximal tibial defects in primary total knee arthroplasty. J Orthop Traumatol. 2024;25(1):22. https:\/\/doi.org\/10.1186\/s10195-024-00762-6.","journal-title":"J Orthop Traumatol"},{"issue":"1","key":"6668_CR24","doi-asserted-by":"publisher","DOI":"10.1186\/s10195-024-00750-w","volume":"25","author":"WS Lee","year":"2024","unstructured":"Lee WS, Park KK, Cho BW, Park JY, Kim I, Kwon HM. Risk factors for early septic failure after two-stage exchange total knee arthroplasty for treatment of periprosthetic joint infection. J Orthop Traumatol. 2024;25(1):6. https:\/\/doi.org\/10.1186\/s10195-024-00750-w.","journal-title":"J Orthop Traumatol"},{"key":"6668_CR25","doi-asserted-by":"publisher","DOI":"10.1002\/ksa.12751","author":"A Koutp","year":"2025","unstructured":"Koutp A, Schroedter R, Leitner L, Vielgut I, Leithner A, Sadoghi P. Unrestricted kinematic alignment offers limited functional benefit over mechanical alignment in medial pivot total knee arthroplasty: a randomized controlled trial using conventional instrumentation. Knee Surg Sports Traumatol Arthrosc. 2025. https:\/\/doi.org\/10.1002\/ksa.12751.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"6","key":"6668_CR26","doi-asserted-by":"publisher","first-page":"596","DOI":"10.1055\/s-0041-1740392","volume":"36","author":"YD Song","year":"2023","unstructured":"Song YD, Nakamura S, Kuriyama S, Nishitani K, Ito H, Morita Y, et al. Biomechanical comparison of kinematic and mechanical knee alignment techniques in a computer simulation medial pivot total knee arthroplasty model. J Knee Surg. 2023;36(6):596\u2013604. https:\/\/doi.org\/10.1055\/s-0041-1740392.","journal-title":"J Knee Surg"},{"issue":"4","key":"6668_CR27","doi-asserted-by":"publisher","first-page":"1741","DOI":"10.1007\/s00402-023-05195-0","volume":"144","author":"F Migliorini","year":"2024","unstructured":"Migliorini F, Pilone M, Schafer L, Simeone F, Bell A, Maffulli N. Functional alignment in robotic-assisted total knee arthroplasty: a systematic review. Arch Orthop Trauma Surg. 2024;144(4):1741\u20139. https:\/\/doi.org\/10.1007\/s00402-023-05195-0.","journal-title":"Arch Orthop Trauma Surg"},{"issue":"3","key":"6668_CR28","doi-asserted-by":"publisher","first-page":"693","DOI":"10.1002\/ksa.12089","volume":"32","author":"AE Niesen","year":"2024","unstructured":"Niesen AE, Tirumalai PA, Howell SM, Hull ML. Risk of tibial baseplate loosening is low in patients following unrestricted kinematic alignment total knee arthroplasty using a cruciate-retaining medial conforming insert: a study using radiostereometric analysis at 2 years. Knee Surg Sports Traumatol Arthrosc. 2024;32(3):693\u2013703. https:\/\/doi.org\/10.1002\/ksa.12089.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"7","key":"6668_CR29","doi-asserted-by":"publisher","first-page":"2133","DOI":"10.1016\/j.arth.2017.02.028","volume":"32","author":"AM Almaawi","year":"2017","unstructured":"Almaawi AM, Hutt JRB, Masse V, Lavigne M, Vendittoli PA. The impact of mechanical and restricted kinematic alignment on knee anatomy in total knee arthroplasty. J Arthroplasty. 2017;32(7):2133\u201340. https:\/\/doi.org\/10.1016\/j.arth.2017.02.028.","journal-title":"J Arthroplasty"},{"issue":"2","key":"6668_CR30","doi-asserted-by":"publisher","first-page":"654","DOI":"10.1002\/ksa.12452","volume":"33","author":"MW Morcos","year":"2025","unstructured":"Morcos MW, Beckers G, Salvi AG, Bennani M, Masse V, Vendittoli PA. Excellent results of restricted kinematic alignment total knee arthroplasty at a minimum of 10 years of follow-up. Knee Surg Sports Traumatol Arthrosc. 2025;33(2):654\u201365. https:\/\/doi.org\/10.1002\/ksa.12452.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"6668_CR31","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1007\/978-3-030-24243-5_17","volume":"1","author":"WG Blakeney","year":"2020","unstructured":"Blakeney WG, Vendittoli PA. Restricted kinematic alignment: the ideal compromise? Personal Hip Knee Joint Replace. 2020;1:197\u2013206.","journal-title":"Personal Hip Knee Joint Replace"},{"key":"6668_CR32","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1016\/j.knee.2023.10.003","volume":"45","author":"G Cortina","year":"2023","unstructured":"Cortina G, Za P, Papalia GF, Gregori P, Condello V, Vasta S, et al. Restricted kinematic alignment is clinically non-inferior to mechanical alignment in the short and mid-term: a systematic review. Knee. 2023;45:137\u201346. https:\/\/doi.org\/10.1016\/j.knee.2023.10.003.","journal-title":"Knee"},{"issue":"1","key":"6668_CR33","doi-asserted-by":"publisher","DOI":"10.1186\/s10195-023-00702-w","volume":"24","author":"F Matassi","year":"2023","unstructured":"Matassi F, Pettinari F, Frascona F, Innocenti M, Civinini R. Coronal alignment in total knee arthroplasty: a review. J Orthop Traumatol. 2023;24(1):24. https:\/\/doi.org\/10.1186\/s10195-023-00702-w.","journal-title":"J Orthop Traumatol"},{"issue":"2","key":"6668_CR34","doi-asserted-by":"publisher","first-page":"273","DOI":"10.1007\/s00264-013-2227-4","volume":"38","author":"R Rossi","year":"2014","unstructured":"Rossi R, Rosso F, Cottino U, Dettoni F, Bonasia DE, Bruzzone M. Total knee arthroplasty in the valgus knee. Int Orthop. 2014;38(2):273\u201383. https:\/\/doi.org\/10.1007\/s00264-013-2227-4.","journal-title":"Int Orthop"},{"key":"6668_CR35","doi-asserted-by":"publisher","DOI":"10.3390\/jcm13051302","author":"CM Sterneder","year":"2024","unstructured":"Sterneder CM, Faschingbauer M, Haralambiev L, Kasparek MF, Boettner F. Why kinematic alignment makes little sense in valgus osteoarthritis of the knee: a narrative review. J Clin Med. 2024. https:\/\/doi.org\/10.3390\/jcm13051302.","journal-title":"J Clin Med"},{"key":"6668_CR36","unstructured":"Howick J CI, Glasziou P, Greenhalgh T, Carl Heneghan, Liberati A, Moschetti I, Phillips B, Thornton H, Goddard O, Hodgkinson M (2011) The 2011 Oxford CEBM Levels of Evidence. Oxford Centre for Evidence-Based Medicine. Available at https:\/\/wwwcebmnet\/indexaspx"},{"key":"6668_CR37","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.n71","volume":"372","author":"MJ Page","year":"2021","unstructured":"Page MJ, McKenzie JE, Bossuyt PM, Boutron I, Hoffmann TC, Mulrow CD, et al. The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. BMJ. 2021;372:n71. https:\/\/doi.org\/10.1136\/bmj.n71.","journal-title":"BMJ"},{"key":"6668_CR38","unstructured":"Higgins JPT TJ, Chandler J, Cumpston M, Li T, Page MJ, Welch VA (editors). Cochrane Handbook for Systematic Reviews of Interventions version 6.3 (updated February 2022). Cochrane, 2022. Available from www.training.cochrane.org\/handbook."},{"key":"6668_CR39","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.l4898","volume":"366","author":"JAC Sterne","year":"2019","unstructured":"Sterne JAC, Savovic J, Page MJ, Elbers RG, Blencowe NS, Boutron I, et al. RoB 2: a revised tool for assessing risk of bias in randomised trials. BMJ. 2019;366:l4898. https:\/\/doi.org\/10.1136\/bmj.l4898.","journal-title":"BMJ"},{"key":"6668_CR40","unstructured":"Higgins JPT SJ, Page MJ, Elbers RG, Sterne JAC. Chapter 8: Assessing risk of bias in a randomized trial. In: Higgins JPT, Thomas J, Chandler J, Cumpston M, Li T, Page MJ, Welch VA (editors). Cochrane Handbook for Systematic Reviews of Interventions version 6.3 (updated February 2022). Cochrane, 2022. Available from www.training.cochrane.org\/handbook."},{"key":"6668_CR41","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.d5928","volume":"343","author":"JP Higgins","year":"2011","unstructured":"Higgins JP, Altman DG, Gotzsche PC, Juni P, Moher D, Oxman AD, et al. The Cochrane Collaboration\u2019s tool for assessing risk of bias in randomised trials. BMJ. 2011;343:d5928. https:\/\/doi.org\/10.1136\/bmj.d5928.","journal-title":"BMJ"},{"key":"6668_CR42","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.i4919","volume":"355","author":"JA Sterne","year":"2016","unstructured":"Sterne JA, Hernan MA, Reeves BC, Savovic J, Berkman ND, Viswanathan M, et al. ROBINS-I: a tool for assessing risk of bias in non-randomised studies of interventions. BMJ. 2016;355:i4919. https:\/\/doi.org\/10.1136\/bmj.i4919.","journal-title":"BMJ"},{"key":"6668_CR43","doi-asserted-by":"publisher","DOI":"10.1002\/jrsm.1411","author":"LA McGuinness","year":"2020","unstructured":"McGuinness LA, Higgins JPT. Risk-of-bias VISualization (robvis): an R package and Shiny web app for visualizing risk-of-bias assessments. Res Synth Methods. 2020. https:\/\/doi.org\/10.1002\/jrsm.1411.","journal-title":"Res Synth Methods"},{"key":"6668_CR44","unstructured":"Higgins JPT TJ, Chandler J, Cumpston M, Li T, Page MJ, Welch VA . Cochrane Handbook for Systematic Reviews of Interventions version 6.2. Cochrane 2021. Available from www.training.cochrane.org\/handbook. Accessed on February 2022."},{"issue":"5","key":"6668_CR45","doi-asserted-by":"publisher","first-page":"693","DOI":"10.1016\/j.arth.2010.04.022","volume":"26","author":"DK Bae","year":"2011","unstructured":"Bae DK, Song SJ, Cho SD. Clinical outcome of total knee arthroplasty with medial pivot prosthesis a comparative study between the cruciate retaining and sacrificing. J Arthroplasty. 2011;26(5):693\u20138. https:\/\/doi.org\/10.1016\/j.arth.2010.04.022.","journal-title":"J Arthroplasty"},{"issue":"1","key":"6668_CR46","doi-asserted-by":"publisher","first-page":"90","DOI":"10.4055\/cios20268","volume":"14","author":"S Batra","year":"2022","unstructured":"Batra S, Malhotra R. Medial ball and socket total knee arthroplasty in Indian population: 5-year clinical results. Clin Orthop Surg. 2022;14(1):90\u20135. https:\/\/doi.org\/10.4055\/cios20268.","journal-title":"Clin Orthop Surg"},{"issue":"12","key":"6668_CR47","doi-asserted-by":"publisher","first-page":"5856","DOI":"10.1007\/s00167-023-07634-2","volume":"31","author":"NC Budhiparama","year":"2023","unstructured":"Budhiparama NC, Lumban-Gaol I, Novito K, Hidayat H, De Meo F, Cacciola G, et al. PCL retained is safe in medial pivot TKA-a prospective randomized trial. Knee Surg Sports Traumatol Arthrosc. 2023;31(12):5856\u201363. https:\/\/doi.org\/10.1007\/s00167-023-07634-2.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"2","key":"6668_CR48","doi-asserted-by":"publisher","first-page":"387","DOI":"10.1016\/j.knee.2013.10.005","volume":"21","author":"N Chinzei","year":"2014","unstructured":"Chinzei N, Ishida K, Tsumura N, Matsumoto T, Kitagawa A, Iguchi T, et al. Satisfactory results at 8 years mean follow-up after ADVANCE(R) medial-pivot total knee arthroplasty. Knee. 2014;21(2):387\u201390. https:\/\/doi.org\/10.1016\/j.knee.2013.10.005.","journal-title":"Knee"},{"issue":"3","key":"6668_CR49","doi-asserted-by":"publisher","first-page":"824","DOI":"10.1016\/j.arth.2016.08.028","volume":"32","author":"NY Choi","year":"2017","unstructured":"Choi NY, In Y, Bae JH, Do JH, Chung SJ, Koh IJ. Are midterm patient-reported outcome measures between rotating-platform mobile-bearing prosthesis and medial-pivot prosthesis different? A minimum of 5-year follow-up study. J Arthroplasty. 2017;32(3):824\u20139. https:\/\/doi.org\/10.1016\/j.arth.2016.08.028.","journal-title":"J Arthroplasty"},{"issue":"9","key":"6668_CR50","doi-asserted-by":"publisher","first-page":"3627","DOI":"10.1007\/s00167-021-06668-8","volume":"31","author":"CM Delman","year":"2023","unstructured":"Delman CM, Ridenour D, Howell SM, Hull ML. The posterolateral upslope of a low-conforming insert blocks the medial pivot during a deep knee bend in TKA: a comparative analysis of two implants with different insert conformities. Knee Surg Sports Traumatol Arthrosc. 2023;31(9):3627\u201336. https:\/\/doi.org\/10.1007\/s00167-021-06668-8.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"7","key":"6668_CR51","doi-asserted-by":"publisher","first-page":"1737","DOI":"10.1007\/s00264-023-05834-6","volume":"47","author":"SP Elorza","year":"2023","unstructured":"Elorza SP, O\u2019Donnell E, Nedopil A, Howell SM, Hull ML. Ball-in-socket medial conformity with posterior cruciate ligament retention neither limits internal tibial rotation and knee flexion nor lowers clinical outcome scores after unrestricted kinematically aligned total knee arthroplasty. Int Orthop. 2023;47(7):1737\u201346. https:\/\/doi.org\/10.1007\/s00264-023-05834-6.","journal-title":"Int Orthop"},{"key":"6668_CR52","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1016\/j.knee.2023.05.012","volume":"43","author":"S Pacheco Elorza","year":"2023","unstructured":"Pacheco Elorza S, O\u2019Donnell E, Delman C, Howell SM, Hull ML. Posterior cruciate ligament retention with medial ball-in-socket conformity promotes internal tibial rotation and knee flexion while providing high clinical outcome scores. Knee. 2023;43:153\u201362. https:\/\/doi.org\/10.1016\/j.knee.2023.05.012.","journal-title":"Knee"},{"issue":"3","key":"6668_CR53","doi-asserted-by":"publisher","first-page":"492","DOI":"10.1016\/j.arth.2009.05.008","volume":"25","author":"CY Fan","year":"2010","unstructured":"Fan CY, Hsieh JT, Hsieh MS, Shih YC, Lee CH. Primitive results after medial-pivot knee arthroplasties: a minimum 5-year follow-up study. J Arthroplasty. 2010;25(3):492\u20136. https:\/\/doi.org\/10.1016\/j.arth.2009.05.008.","journal-title":"J Arthroplasty"},{"key":"6668_CR54","doi-asserted-by":"publisher","DOI":"10.1002\/ksa.12712","author":"SM Howell","year":"2025","unstructured":"Howell SM, Zabiba A, Nedopil AJ, Hull ML. The forgotten joint score after total knee arthroplasty with a kinematic alignment-optimized femoral component matches total hip arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2025. https:\/\/doi.org\/10.1002\/ksa.12712.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"12","key":"6668_CR55","doi-asserted-by":"publisher","DOI":"10.1016\/j.heliyon.2023.e22741","volume":"9","author":"M Hu","year":"2023","unstructured":"Hu M, Xiang S, Xu H, Wang Y, Lv C, Zhang H. Equivalence of clinical and radiological outcomes in cruciate-retaining and cruciate-substituting total knee arthroplasty with medial pivot knee: a comparative study. Heliyon. 2023;9(12):e22741. https:\/\/doi.org\/10.1016\/j.heliyon.2023.e22741.","journal-title":"Heliyon"},{"issue":"3","key":"6668_CR56","doi-asserted-by":"publisher","first-page":"576","DOI":"10.1007\/s00167-012-2314-x","volume":"22","author":"K Ishida","year":"2014","unstructured":"Ishida K, Matsumoto T, Tsumura N, Iwakura T, Kubo S, Iguchi T, et al. No difference between double-high insert and medial-pivot insert in TKA. Knee Surg Sports Traumatol Arthrosc. 2014;22(3):576\u201380. https:\/\/doi.org\/10.1007\/s00167-012-2314-x.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"4","key":"6668_CR57","doi-asserted-by":"publisher","DOI":"10.1002\/jeo2.70013","volume":"11","author":"T Kage","year":"2024","unstructured":"Kage T, Kono K, Tomita T, Yamazaki T, Taketomi S, Yamagami R, et al. Medial pivot total knee arthroplasty for valgus knees provides equivalent medial stability compared to that for varus knees: in vivo kinematic study. J Exp Orthop. 2024;11(4):e70013. https:\/\/doi.org\/10.1002\/jeo2.70013.","journal-title":"J Exp Orthop"},{"issue":"8","key":"6668_CR58","doi-asserted-by":"publisher","first-page":"2771","DOI":"10.1016\/j.arth.2021.03.007","volume":"36","author":"T Karachalios","year":"2021","unstructured":"Karachalios T, Komnos G, Hantes M, Varitimidis S. Evaluating the \u201cPatella-Friendly\u201d concept in total knee arthroplasty: a minimum 15-year follow-up outcome study comparing constant radius, multiradius cruciate-retaining, and nonanatomical cruciate-retaining implants. J Arthroplasty. 2021;36(8):2771\u20138. https:\/\/doi.org\/10.1016\/j.arth.2021.03.007.","journal-title":"J Arthroplasty"},{"issue":"8","key":"6668_CR59","doi-asserted-by":"publisher","first-page":"1050","DOI":"10.1302\/0301-620X.98B8.36208","volume":"98-B","author":"T Karachalios","year":"2016","unstructured":"Karachalios T, Varitimidis S, Bargiotas K, Hantes M, Roidis N, Malizos KN. An 11- to 15-year clinical outcome study of the Advance Medial Pivot total knee arthroplasty: pivot knee arthroplasty. Bone Joint J. 2016;98-B(8):1050\u20135. https:\/\/doi.org\/10.1302\/0301-620X.98B8.36208.","journal-title":"Bone Joint J"},{"issue":"1","key":"6668_CR60","doi-asserted-by":"publisher","first-page":"97","DOI":"10.52628\/89.1.10252","volume":"89","author":"M Karahan","year":"2023","unstructured":"Karahan M, Acar E, Serarslan U, Gultekin A. Medial pivot total knee arthroplasty: mid-term results. Acta Orthop Belg. 2023;89(1):97\u2013102. https:\/\/doi.org\/10.52628\/89.1.10252.","journal-title":"Acta Orthop Belg"},{"issue":"1","key":"6668_CR61","doi-asserted-by":"publisher","DOI":"10.1186\/s12891-018-2138-z","volume":"19","author":"J Nakamura","year":"2018","unstructured":"Nakamura J, Inoue T, Suguro T, Suzuki M, Sasho T, Hagiwara S, et al. A comparative study of flat surface design and medial pivot design in posterior cruciate-retaining total knee arthroplasty: a matched pair cohort study of two years. BMC Musculoskelet Disord. 2018;19(1):234. https:\/\/doi.org\/10.1186\/s12891-018-2138-z.","journal-title":"BMC Musculoskelet Disord"},{"issue":"2","key":"6668_CR62","doi-asserted-by":"publisher","first-page":"434","DOI":"10.1016\/j.knee.2016.12.011","volume":"24","author":"S Nakamura","year":"2017","unstructured":"Nakamura S, Minoda Y, Nakagawa S, Kadoya Y, Takemura S, Kobayashi A, et al. Clinical results of alumina medial pivot total knee arthroplasty at a minimum follow-up of 10years. Knee. 2017;24(2):434\u20138. https:\/\/doi.org\/10.1016\/j.knee.2016.12.011.","journal-title":"Knee"},{"key":"6668_CR63","doi-asserted-by":"publisher","first-page":"758","DOI":"10.2340\/17453674.2024.42489","volume":"95","author":"AE Niesen","year":"2024","unstructured":"Niesen AE, Tirumalai PA, Howell SM, Hull ML. A new tibial insert design with ball-in-socket medial conformity and posterior cruciate ligament retention has low tibial baseplate migration after unrestricted kinematically aligned total knee arthroplasty: a cohort study using radiostereometric analysis. Acta Orthop. 2024;95:758\u201364. https:\/\/doi.org\/10.2340\/17453674.2024.42489.","journal-title":"Acta Orthop"},{"issue":"3","key":"6668_CR64","doi-asserted-by":"publisher","first-page":"629","DOI":"10.1007\/s00264-025-06420-8","volume":"49","author":"B Obada","year":"2025","unstructured":"Obada B, Iliescu MG, Costea DO, Petcu L, Popescu AI. Comparative study of outcomes with total knee arthroplasty: medial pivot prosthesis vs posterior stabilized implant. Prospective randomized control. Int Orthop. 2025;49(3):629\u201339. https:\/\/doi.org\/10.1007\/s00264-025-06420-8.","journal-title":"Int Orthop"},{"issue":"4","key":"6668_CR65","doi-asserted-by":"publisher","DOI":"10.1002\/jeo2.70075","volume":"11","author":"D Razick","year":"2024","unstructured":"Razick D, Akhtar M, Howell SM, Nedopil AJ, Hull ML. The location of the centre of the proximal quadriceps tendon in kinematically aligned total knee arthroplasty is not associated with poor outcome scores or symptomatic patellar instability. J Exp Orthop. 2024;11(4):e70075. https:\/\/doi.org\/10.1002\/jeo2.70075.","journal-title":"J Exp Orthop"},{"key":"6668_CR66","doi-asserted-by":"publisher","first-page":"427","DOI":"10.1016\/j.jor.2020.08.025","volume":"21","author":"S Risitano","year":"2020","unstructured":"Risitano S, Sabatini L, Barberis L, Fusini F, Malavolta M, Indelli PF. Combining kinematic alignment and medial stabilized design in total knee arthroplasty: basic rationale and preliminary clinical evidences. J Orthop. 2020;21:427\u201331. https:\/\/doi.org\/10.1016\/j.jor.2020.08.025.","journal-title":"J Orthop"},{"key":"6668_CR67","doi-asserted-by":"publisher","DOI":"10.3390\/jcm12237258","author":"C Sosio","year":"2023","unstructured":"Sosio C, Rossi N, Sirtori P, Ciliberto R, Lombardo MDM, Peretti GM, et al. Clinical and functional outcomes of kinematic aligned total knee arthroplasty with a medial pivot design: two-year follow-up. J Clin Med. 2023. https:\/\/doi.org\/10.3390\/jcm12237258.","journal-title":"J Clin Med"},{"issue":"1","key":"6668_CR68","doi-asserted-by":"publisher","DOI":"10.1186\/s42836-023-00180-9","volume":"5","author":"H Ueyama","year":"2023","unstructured":"Ueyama H, Nakagawa S, Kishimura Y, Minoda Y, Nakamura S, Koyanagi J, et al. Long-term clinical results of alumina ceramic medial pivot total knee arthroplasty: a 10-year follow-up study. Arthroplasty. 2023;5(1):27. https:\/\/doi.org\/10.1186\/s42836-023-00180-9.","journal-title":"Arthroplasty"},{"issue":"8","key":"6668_CR69","doi-asserted-by":"publisher","first-page":"2057","DOI":"10.1007\/s00402-021-04121-6","volume":"142","author":"H Ueyama","year":"2022","unstructured":"Ueyama H, Kanemoto N, Minoda Y, Yamamoto N, Taniguchi Y, Nakamura H. Comparison of postoperative knee flexion and patient satisfaction between newly and conventionally designed medial pivot total knee arthroplasty: a 5-year follow-up matched cohort study. Arch Orthop Trauma Surg. 2022;142(8):2057\u201364. https:\/\/doi.org\/10.1007\/s00402-021-04121-6.","journal-title":"Arch Orthop Trauma Surg"},{"issue":"2","key":"6668_CR70","doi-asserted-by":"publisher","first-page":"279","DOI":"10.1016\/j.arth.2021.11.016","volume":"37","author":"H Ueyama","year":"2022","unstructured":"Ueyama H, Kanemoto N, Minoda Y, Yamamoto N, Taniguchi Y, Nakamura H. No difference in postoperative knee flexion and patient joint awareness between cruciate-substituting and cruciate-retaining medial pivot total knee prostheses: a 10-year follow-up study. J Arthroplasty. 2022;37(2):279\u201385. https:\/\/doi.org\/10.1016\/j.arth.2021.11.016.","journal-title":"J Arthroplasty"},{"issue":"6","key":"6668_CR71","doi-asserted-by":"publisher","first-page":"851","DOI":"10.1016\/j.knee.2012.04.002","volume":"19","author":"E Vecchini","year":"2012","unstructured":"Vecchini E, Christodoulidis A, Magnan B, Ricci M, Regis D, Bartolozzi P. Clinical and radiologic outcomes of total knee arthroplasty using the Advance Medial Pivot prosthesis. A mean 7 years follow-up. Knee. 2012;19(6):851\u20135. https:\/\/doi.org\/10.1016\/j.knee.2012.04.002.","journal-title":"Knee"},{"issue":"11","key":"6668_CR72","doi-asserted-by":"publisher","first-page":"2877","DOI":"10.1007\/s00264-021-05017-1","volume":"45","author":"S Xiang","year":"2021","unstructured":"Xiang S, Wang Y, Lv C, Wang C, Zhang H. Mid-term clinical outcomes and survivorship of medial-pivot total knee arthroplasty-a mean five year follow-up based on one thousand, one hundred and twenty eight cases. Int Orthop. 2021;45(11):2877\u201383. https:\/\/doi.org\/10.1007\/s00264-021-05017-1.","journal-title":"Int Orthop"},{"issue":"3","key":"6668_CR73","doi-asserted-by":"publisher","first-page":"135","DOI":"10.5792\/ksrr.2014.26.3.135","volume":"26","author":"YS Youm","year":"2014","unstructured":"Youm YS, Cho SD, Lee SH, Cho HY. Total knee arthroplasty using a posterior cruciate ligament sacrificing medial pivot knee: minimum 5-year follow-up results. Knee Surg Relat Res. 2014;26(3):135\u201340. https:\/\/doi.org\/10.5792\/ksrr.2014.26.3.135.","journal-title":"Knee Surg Relat Res"},{"issue":"1","key":"6668_CR74","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1186\/s13643-023-02393-0","volume":"13","author":"MDC Silva","year":"2024","unstructured":"Silva MDC, Woodward AP, Fearon AM, Perriman DM, Spencer TJ, Couldrick JM, et al. Minimal clinically important change of knee flexion in people with knee osteoarthritis after non-surgical interventions using a meta-analytical approach. Syst Rev. 2024;13(1):50. https:\/\/doi.org\/10.1186\/s13643-023-02393-0.","journal-title":"Syst Rev"},{"issue":"5","key":"6668_CR75","doi-asserted-by":"publisher","first-page":"846","DOI":"10.1302\/0301-620X.103B5.BJJ-2020-0396.R1","volume":"103-B","author":"ND Clement","year":"2021","unstructured":"Clement ND, Scott CEH, Hamilton DF, MacDonald D, Howie CR. Meaningful values in the Forgotten Joint Score after total knee arthroplasty. Bone Joint J. 2021;103-B(5):846\u201354. https:\/\/doi.org\/10.1302\/0301-620X.103B5.BJJ-2020-0396.R1.","journal-title":"Bone Joint J"},{"issue":"3","key":"6668_CR76","doi-asserted-by":"publisher","first-page":"591","DOI":"10.1016\/j.arth.2023.11.023","volume":"39","author":"G Beckers","year":"2024","unstructured":"Beckers G, Meneghini RM, Hirschmann MT, Kostretzis L, Kiss MO, Vendittoli PA. Ten flaws of systematic mechanical alignment total knee arthroplasty. J Arthroplasty. 2024;39(3):591\u20139. https:\/\/doi.org\/10.1016\/j.arth.2023.11.023.","journal-title":"J Arthroplasty"},{"key":"6668_CR77","doi-asserted-by":"publisher","DOI":"10.3390\/medicina59101852","author":"LE Streck","year":"2023","unstructured":"Streck LE, Faschingbauer M, Brenneis M, Boettner CS, List K, Kasparek MF, et al. Individual phenotype does not impact the outcome of mechanical aligned total knee arthroplasties for valgus osteoarthritis. Medicina Kaunas. 2023. https:\/\/doi.org\/10.3390\/medicina59101852.","journal-title":"Medicina Kaunas"},{"issue":"9","key":"6668_CR78","doi-asserted-by":"publisher","first-page":"4475","DOI":"10.1007\/s00402-024-05551-8","volume":"144","author":"I Shichman","year":"2024","unstructured":"Shichman I, Hadad A, Brandstetter AS, Ashkenazi I, Warschwaski Y, Gold A, et al. Better restoration of joint line obliquity in tibia first restricted kinematic alignment versus mechanical alignment TKA. Arch Orthop Trauma Surg. 2024;144(9):4475\u201381. https:\/\/doi.org\/10.1007\/s00402-024-05551-8.","journal-title":"Arch Orthop Trauma Surg"},{"key":"6668_CR79","doi-asserted-by":"publisher","first-page":"142","DOI":"10.1016\/j.jor.2025.05.051","volume":"69","author":"A Pintore","year":"2025","unstructured":"Pintore A, Notarfrancesco D, Zara A, Oliva F, Migliorini F, Maffulli N. Kinematic alignment in total knee arthroplasty restores the native anatomy, with a joint line parallel to the ground on a standing view. J Orthop. 2025;69:142\u20139. https:\/\/doi.org\/10.1016\/j.jor.2025.05.051.","journal-title":"J Orthop"},{"issue":"1","key":"6668_CR80","doi-asserted-by":"publisher","DOI":"10.1186\/s40001-025-02747-5","volume":"30","author":"L Shao","year":"2025","unstructured":"Shao L, Wu X, Fang C, Zhu H, Tao K, Wang S. Effect of tibial rotational alignment and posterior slope on joint biomechanics in posterior-stabilized total knee arthroplasty: a finite element study. Eur J Med Res. 2025;30(1):476. https:\/\/doi.org\/10.1186\/s40001-025-02747-5.","journal-title":"Eur J Med Res"},{"key":"6668_CR81","doi-asserted-by":"publisher","DOI":"10.3389\/fbioe.2024.1352794","volume":"12","author":"N Guo","year":"2024","unstructured":"Guo N, Smith CR, Schutz P, Trepczynski A, Moewis P, Damm P, et al. Posterior tibial slope influences joint mechanics and soft tissue loading after total knee arthroplasty. Front Bioeng Biotechnol. 2024;12:1352794. https:\/\/doi.org\/10.3389\/fbioe.2024.1352794.","journal-title":"Front Bioeng Biotechnol"},{"key":"6668_CR82","doi-asserted-by":"publisher","DOI":"10.1002\/ksa.70022","author":"Y Ohyama","year":"2025","unstructured":"Ohyama Y, Minoda Y, Masuda S, Sugama R, Ueyama H, Terai H. Posterior femoral condylar morphology following mechanical vs. kinematic alignment using a medial-pivot implant designed for mechanical alignment: A CT-based comparative study. Knee Surg Sports Traumatol Arthrosc. 2025. https:\/\/doi.org\/10.1002\/ksa.70022.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"3","key":"6668_CR83","doi-asserted-by":"publisher","DOI":"10.1002\/jeo2.70343","volume":"12","author":"F Mancino","year":"2025","unstructured":"Mancino F, Fontalis A, Plastow R, Haddad FS. A medial pivot kinematic pattern could be achieved in a significant proportion of patients with varus knees after primary total knee arthroplasty using functional positioning. J Exp Orthop. 2025;12(3):e70343. https:\/\/doi.org\/10.1002\/jeo2.70343.","journal-title":"J Exp Orthop"},{"issue":"12","key":"6668_CR84","doi-asserted-by":"publisher","first-page":"22","DOI":"10.5435\/JAAOSGlobal-D-22-00170","volume":"6","author":"W Hoskins","year":"2022","unstructured":"Hoskins W, Smith G, Spelman T, Vince KG. Medial pivot designs versus conventional bearing types in primary total knee arthroplasty: a systematic review and meta-analysis of randomized controlled trials. J Am Acad Orthop Surg Glob Res Rev. 2022;6(12):22. https:\/\/doi.org\/10.5435\/JAAOSGlobal-D-22-00170.","journal-title":"J Am Acad Orthop Surg Glob Res Rev"},{"issue":"1","key":"6668_CR85","doi-asserted-by":"publisher","first-page":"3052","DOI":"10.1038\/s41598-022-06909-x","volume":"12","author":"G Putame","year":"2022","unstructured":"Putame G, Terzini M, Rivera F, Kebbach M, Bader R, Bignardi C. Kinematics and kinetics comparison of ultra-congruent versus medial-pivot designs for total knee arthroplasty by multibody analysis. Sci Rep. 2022;12(1):3052. https:\/\/doi.org\/10.1038\/s41598-022-06909-x.","journal-title":"Sci Rep"},{"issue":"9","key":"6668_CR86","doi-asserted-by":"publisher","first-page":"3734","DOI":"10.1007\/s00167-023-07307-0","volume":"31","author":"D Zou","year":"2023","unstructured":"Zou D, Ling Z, Tan J, Zheng N, Dimitriou D, Chen Y, et al. Medial stability and lateral flexibility of the collateral ligaments during mid-range flexion in medial-pivot total knee arthroplasty patients demonstrates favorable postoperative outcomes. Knee Surg Sports Traumatol Arthrosc. 2023;31(9):3734\u201344. https:\/\/doi.org\/10.1007\/s00167-023-07307-0.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"7","key":"6668_CR87","doi-asserted-by":"publisher","first-page":"2527","DOI":"10.1002\/ksa.12624","volume":"33","author":"L Bauer","year":"2025","unstructured":"Bauer L, Niethammer TR, Thorwachter C, Woiczinski M, Muller PE, Simon F, et al. Improved quadriceps efficiency with a medial pivot in comparison to a cruciate-retaining design in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2025;33(7):2527\u201336. https:\/\/doi.org\/10.1002\/ksa.12624.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"1","key":"6668_CR88","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1002\/jor.25642","volume":"42","author":"N Soltanihafshejani","year":"2024","unstructured":"Soltanihafshejani N, Bitter T, Verdonschot N, Janssen D. The effect of periprosthetic bone loss on the failure risk of tibial total knee arthroplasty. J Orthop Res. 2024;42(1):90\u20139. https:\/\/doi.org\/10.1002\/jor.25642.","journal-title":"J Orthop Res"},{"issue":"1","key":"6668_CR89","doi-asserted-by":"publisher","first-page":"338","DOI":"10.1186\/s13018-025-05709-z","volume":"20","author":"JY Tran","year":"2025","unstructured":"Tran JY, Chan EO, Wong CK, Lam GY, Choi TL, Mak RW, et al. Coronal plane alignment changes do not affect outcome for total knee implant design with 3 degree varus joint line. J Orthop Surg Res. 2025;20(1):338. https:\/\/doi.org\/10.1186\/s13018-025-05709-z.","journal-title":"J Orthop Surg Res"},{"key":"6668_CR90","doi-asserted-by":"publisher","first-page":"274","DOI":"10.1016\/j.knee.2023.01.015","volume":"41","author":"T Kaneko","year":"2023","unstructured":"Kaneko T, Yamamoto A, Takada K, Yoshizawa S. Coronal alignment classes after robotic-assisted total knee arthroplasty are not associated with variation in patient-reported outcome measurements: a single-center cohort study. Knee. 2023;41:274\u201382. https:\/\/doi.org\/10.1016\/j.knee.2023.01.015.","journal-title":"Knee"},{"issue":"9","key":"6668_CR91","doi-asserted-by":"publisher","first-page":"S45","DOI":"10.1016\/j.arth.2024.02.078","volume":"39","author":"ZA Mosher","year":"2024","unstructured":"Mosher ZA, Bolognesi MP, Malkani AL, Meneghini RM, Oni JK, Fricka KB. Cementless total knee arthroplasty: a resurgence\u2014who, when, where, and how? J Arthroplasty. 2024;39(9):S45\u201353.","journal-title":"J Arthroplasty"},{"key":"6668_CR92","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1016\/j.artd.2022.06.012","volume":"17","author":"D Torino","year":"2022","unstructured":"Torino D, Damsgaard C, Kolessar DJ, Hayes DS, Foster B, Constantino J, et al. Tibial baseplate-cement interface debonding in the ATTUNE total knee arthroplasty system. Arthroplast Today. 2022;17:165\u201371. https:\/\/doi.org\/10.1016\/j.artd.2022.06.012.","journal-title":"Arthroplast Today"},{"key":"6668_CR93","doi-asserted-by":"publisher","first-page":"327","DOI":"10.2147\/JHL.S383916","volume":"15","author":"F Migliorini","year":"2023","unstructured":"Migliorini F, Feierabend M, Hofmann UK. Fostering excellence in knee arthroplasty: developing optimal patient care pathways and inspiring knowledge transfer of advanced surgical techniques. J Healthc Leadersh. 2023;15:327\u201338. https:\/\/doi.org\/10.2147\/JHL.S383916.","journal-title":"J Healthc Leadersh"},{"issue":"7S1","key":"6668_CR94","doi-asserted-by":"publisher","first-page":"S243","DOI":"10.1016\/j.arth.2025.03.021","volume":"40","author":"ZJ Parisi","year":"2025","unstructured":"Parisi ZJ, Stambough JB, Siegel ER, Mears SC, Barnes CL, Stronach BM. Outcomes of Medial Pivot Total Knee Arthroplasty based on preoperative coronal deformity. J Arthroplasty. 2025;40(7S1):S243\u20139. https:\/\/doi.org\/10.1016\/j.arth.2025.03.021.","journal-title":"J Arthroplasty"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13018-026-06668-9","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-026-06668-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-026-06668-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,9]],"date-time":"2026-04-09T08:04:16Z","timestamp":1775721856000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s13018-026-06668-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,24]]},"references-count":94,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["6668"],"URL":"https:\/\/doi.org\/10.1186\/s13018-026-06668-9","relation":{},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,24]]},"assertion":[{"value":"14 October 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 January 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 March 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study complies with ethical standards.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethicas approval"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}},{"value":"Not applicable.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to publish"}},{"value":"The present review was not registered.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Registration and protocol"}},{"value":"Language editing was performed using Grammarly (Superhuman Platform Inc., San Francisco, CA, USA).","order":6,"name":"Ethics","group":{"name":"EthicsHeading","label":"Use of AI"}},{"value":"The authors declare that they have no competing interests in this article.","order":7,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"245"}}