{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,23]],"date-time":"2026-06-23T00:29:42Z","timestamp":1782174582987,"version":"3.54.5"},"reference-count":39,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,2,23]],"date-time":"2026-02-23T00:00:00Z","timestamp":1771804800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,3,30]],"date-time":"2026-03-30T00:00:00Z","timestamp":1774828800000},"content-version":"vor","delay-in-days":35,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>\n                      Diagnosis of compartment syndrome remains challenging, as intracompartmental pressure (ICP) monitoring measures mechanical pressure rather than tissue perfusion. Near-infrared spectroscopy (NIRS) enables non-invasive, continuous assessment of tissue oxygen saturation (StO\n                      <jats:sub>2<\/jats:sub>\n                      ), potentially identifying ischemia earlier. However, its diagnostic accuracy remains uncertain.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      Following PRISMA-ScR guidelines, PubMed, EMBASE, Cochrane Library, ClinicalTrials.gov, and WHO-ICTRP were searched to April 2025 for studies evaluating NIRS in acute (ACS) or chronic exertional (CECS) compartment syndrome. Data on diagnostic accuracy, device protocols, and patient characteristics were extracted. Studies reporting comparable StO\n                      <jats:sub>2<\/jats:sub>\n                      data in CECS and controls were pooled using a random-effects meta-analysis.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Twenty-three studies (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u20091000) were included. In ACS, some demonstrated strong correlation with perfusion pressure and post-fasciotomy StO\n                      <jats:sub>2<\/jats:sub>\n                      recovery, while others found poor agreement with ICP or no diagnostic discrimination. There was heterogeneity in device type, patient demographics (particularly skin pigmentation), and protocols. In CECS, pooled analysis showed lower baseline StO\n                      <jats:sub>2<\/jats:sub>\n                      (mean difference \u2212\u20093.4%, 95% CI \u2212\u20096.2 to \u2212\u20090.7) and greater exercise-induced deoxygenation (+\u200915.0%, 95% CI 0.4\u201329.7) versus controls.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>NIRS provides a physiologically relevant but technically variable indicator of compartmental perfusion, which may complement, but not replace, ICP monitoring for compartment syndrome. The results presented are hypothesis-generating and require prospective trials with standardised protocols, inclusive calibration, and prospective validation before clinical adoption of NIRS.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s13018-026-06763-x","type":"journal-article","created":{"date-parts":[[2026,2,23]],"date-time":"2026-02-23T03:45:20Z","timestamp":1771818320000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Regional oximetry for diagnosing compartment syndrome: a scoping review"],"prefix":"10.1186","volume":"21","author":[{"ORCID":"https:\/\/orcid.org\/0009-0002-0395-3408","authenticated-orcid":false,"given":"Linda Yuhan","family":"Tang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0005-8396-6146","authenticated-orcid":false,"given":"Dave Osinachukwu","family":"Duru","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4215-7842","authenticated-orcid":false,"given":"Andrew","family":"Browne","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6656-8123","authenticated-orcid":false,"given":"Andrew Kailin","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Saroop","family":"Nandra","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2172-2849","authenticated-orcid":false,"given":"Matija","family":"Krkovic","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,2,23]]},"reference":[{"key":"6763_CR1","doi-asserted-by":"publisher","DOI":"10.26444\/jpccr\/163321","author":"M Miciak","year":"2023","unstructured":"Miciak M, Jurkiewicz K. Compartment syndrome\u2014a complex and insidious medical problem. J Pre-Clin Clin Res. 2023. https:\/\/doi.org\/10.26444\/jpccr\/163321.","journal-title":"J Pre-Clin Clin Res"},{"key":"6763_CR2","doi-asserted-by":"publisher","first-page":"2429","DOI":"10.1007\/s00264-019-04386-y","volume":"43","author":"TE McMillan","year":"2019","unstructured":"McMillan TE, Gardner WT, Schmidt AH, Johnstone AJ. Diagnosing acute compartment syndrome\u2014Where have we got to? Int Orthop. 2019;43:2429\u201335. https:\/\/doi.org\/10.1007\/s00264-019-04386-y.","journal-title":"Int Orthop"},{"key":"6763_CR3","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1016\/j.nurpra.2015.10.013","volume":"12","author":"J Pechar","year":"2016","unstructured":"Pechar J, Lyons MM. Acute compartment syndrome of the lower leg: a review. J Nurse Pract JNP. 2016;12:265\u201370. https:\/\/doi.org\/10.1016\/j.nurpra.2015.10.013.","journal-title":"J Nurse Pract JNP"},{"key":"6763_CR4","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1007\/978-3-030-22331-1_14","volume-title":"Compartment syndrome: a guide to diagnosis and management","author":"C Lee","year":"2019","unstructured":"Lee C, O\u2019Toole RV. Compartment syndrome in polytrauma patients. In: Mauffrey C, Hak DJ, Martin MP, editors. Compartment syndrome: a guide to diagnosis and management. Cham: Springer; 2019. p. 133\u201344."},{"key":"6763_CR5","doi-asserted-by":"publisher","first-page":"71","DOI":"10.2147\/OAJSM.S168368","volume":"10","author":"RA Buerba","year":"2019","unstructured":"Buerba RA, Fretes NF, Devana SK, Beck JJ. Chronic exertional compartment syndrome: current management strategies. Open Access J Sports Med. 2019;10:71\u20139. https:\/\/doi.org\/10.2147\/OAJSM.S168368.","journal-title":"Open Access J Sports Med"},{"key":"6763_CR6","volume-title":"Diagnosis and management of compartment syndrome of the extremities (BOAST)","author":"British Orthopaedic Association","year":"2025","unstructured":"British Orthopaedic Association. Diagnosis and management of compartment syndrome of the extremities (BOAST). London: British Orthopaedic Association; 2025."},{"key":"6763_CR7","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.OA.22.00041","author":"S Vogels","year":"2022","unstructured":"Vogels S, de Vries D, Bakker EWP, et al. Measuring intracompartmental pressures in the lower leg: assessing the use of unilateral measurements in patients with bilateral symptoms. JB JS Open Access. 2022. https:\/\/doi.org\/10.2106\/JBJS.OA.22.00041.","journal-title":"JB JS Open Access"},{"key":"6763_CR8","doi-asserted-by":"publisher","first-page":"279","DOI":"10.1007\/s10877-012-9348-y","volume":"26","author":"TWL Scheeren","year":"2012","unstructured":"Scheeren TWL, Schober P, Schwarte LA. Monitoring tissue oxygenation by near infrared spectroscopy (NIRS): background and current applications. J Clin Monit Comput. 2012;26:279\u201387. https:\/\/doi.org\/10.1007\/s10877-012-9348-y.","journal-title":"J Clin Monit Comput"},{"key":"6763_CR9","doi-asserted-by":"publisher","DOI":"10.1097\/bto.0b013e31824881f6","author":"AL Cole","year":"2012","unstructured":"Cole AL, Smith EK, Austin AV, et al. Near-infrared spectroscopy monitoring for compartment syndrome. Tech Orthop. 2012. https:\/\/doi.org\/10.1097\/bto.0b013e31824881f6.","journal-title":"Tech Orthop"},{"key":"6763_CR10","doi-asserted-by":"publisher","first-page":"467","DOI":"10.7326\/M18-0850","volume":"169","author":"AC Tricco","year":"2018","unstructured":"Tricco AC, Lillie E, Zarin W, et al. PRISMA extension for scoping reviews (PRISMA-ScR): checklist and explanation. Ann Intern Med. 2018;169:467\u201373. https:\/\/doi.org\/10.7326\/M18-0850.","journal-title":"Ann Intern Med"},{"key":"6763_CR11","doi-asserted-by":"publisher","first-page":"417","DOI":"10.2307\/3001616","volume":"10","author":"WG Cochran","year":"1954","unstructured":"Cochran WG. Some methods for strengthening the common \u03c7 2 tests. Biometrics. 1954;10:417. https:\/\/doi.org\/10.2307\/3001616.","journal-title":"Biometrics"},{"key":"6763_CR12","doi-asserted-by":"publisher","first-page":"1539","DOI":"10.1002\/sim.1186","volume":"21","author":"JPT Higgins","year":"2002","unstructured":"Higgins JPT, Thompson SG. Quantifying heterogeneity in a meta-analysis. Stat Med. 2002;21:1539\u201358. https:\/\/doi.org\/10.1002\/sim.1186.","journal-title":"Stat Med"},{"key":"6763_CR13","doi-asserted-by":"crossref","unstructured":"Deeks JJ, Higgins JP, Altman DG, on behalf of the Cochrane Statistical Methods Group. Analysing data and undertaking meta-analyses. In: Cochrane Handbook for Systematic Reviews of Interventions. 2019. pp. 241\u2013284.","DOI":"10.1002\/9781119536604.ch10"},{"key":"6763_CR14","doi-asserted-by":"publisher","DOI":"10.1097\/00005373-200003000-00005","author":"G Giannotti","year":"2000","unstructured":"Giannotti G, Cohn SM, Brown M, et al. Utility of near-infrared spectroscopy in the diagnosis of lower extremity compartment syndrome. J Trauma Injury Infect Crit Care. 2000. https:\/\/doi.org\/10.1097\/00005373-200003000-00005.","journal-title":"J Trauma Injury Infect Crit Care"},{"key":"6763_CR15","doi-asserted-by":"publisher","DOI":"10.26603\/001c.71357","author":"LU T\u00f8nning","year":"2023","unstructured":"T\u00f8nning LU, Mygind-Klavsen B, Kjeldsen T, et al. Muscle strength, oxygen saturation and physical activity in patients with chronic exertional compartment syndrome compared to asymptomatic controls. Int J Sports Phys Ther. 2023. https:\/\/doi.org\/10.26603\/001c.71357.","journal-title":"Int J Sports Phys Ther"},{"key":"6763_CR16","first-page":"209","volume":"35","author":"K Jagadeesan","year":"2022","unstructured":"Jagadeesan K, John AM, Ramachandran V, John PS. Near infrared spectroscopy in monitoring compartment pressure. J Int Med Sci Acad. 2022;35:209\u201312.","journal-title":"J Int Med Sci Acad"},{"key":"6763_CR17","doi-asserted-by":"publisher","first-page":"1645","DOI":"10.2106\/JBJS.17.01495","volume":"100","author":"AH Schmidt","year":"2018","unstructured":"Schmidt AH, Bosse MJ, Obremskey WT, et al. Continuous near-infrared spectroscopy demonstrates limitations in monitoring the development of acute compartment syndrome in patients with leg injuries. J Bone Joint Surg. 2018;100:1645\u201352. https:\/\/doi.org\/10.2106\/JBJS.17.01495.","journal-title":"J Bone Joint Surg"},{"key":"6763_CR18","doi-asserted-by":"publisher","first-page":"699","DOI":"10.1177\/0363546504270565","volume":"33","author":"JGH Van Den Brand","year":"2005","unstructured":"Van Den Brand JGH, Nelson T, Verleisdonk EJMM, Van Der Werken C. The diagnostic value of intracompartmental pressure measurement, magnetic resonance imaging, and near-infrared spectroscopy in chronic exertional compartment syndrome: a prospective study in 50 patients. Am J Sports Med. 2005;33:699\u2013704. https:\/\/doi.org\/10.1177\/0363546504270565.","journal-title":"Am J Sports Med"},{"key":"6763_CR19","doi-asserted-by":"publisher","first-page":"e0186790","DOI":"10.1371\/journal.pone.0186790","volume":"12","author":"P Gustafsson","year":"2017","unstructured":"Gustafsson P, Crenshaw AG, Edmundsson D, et al. Muscle oxygenation in Type 1 diabetic and non-diabetic patients with and without chronic compartment syndrome. PLoS ONE. 2017;12:e0186790. https:\/\/doi.org\/10.1371\/journal.pone.0186790.","journal-title":"PLoS ONE"},{"key":"6763_CR20","doi-asserted-by":"publisher","first-page":"1453","DOI":"10.2106\/JBJS.16.01191","volume":"99","author":"ST Challa","year":"2017","unstructured":"Challa ST, Hargens AR, Uzosike A, Macias BR. Muscle microvascular blood flow, oxygenation, pH, and perfusion pressure decrease in simulated acute compartment syndrome. J Bone Jt Surg. 2017;99:1453\u20139. https:\/\/doi.org\/10.2106\/JBJS.16.01191.","journal-title":"J Bone Jt Surg"},{"key":"6763_CR21","doi-asserted-by":"publisher","DOI":"10.1097\/00005373-200107000-00001","author":"LM Gentilello","year":"2001","unstructured":"Gentilello LM, Sanzone A, Wang L, et al. Near-infrared spectroscopy versus compartment pressure for the diagnosis of lower extremity compartmental syndrome using electromyography-determined measurements of neuromuscular function. J Trauma Injury Infect Crit Care. 2001. https:\/\/doi.org\/10.1097\/00005373-200107000-00001.","journal-title":"J Trauma Injury Infect Crit Care"},{"key":"6763_CR22","doi-asserted-by":"publisher","first-page":"5","DOI":"10.13188\/2334-2846.1000005","volume":"1","author":"SH Lee","year":"2013","unstructured":"Lee SH, Padilla M, Lynch JE, Hargens AR. Noninvasive measurements of pressure for detecting compartment syndromes. J Orthop Rheumatol. 2013;1:5.","journal-title":"J Orthop Rheumatol"},{"key":"6763_CR23","doi-asserted-by":"publisher","first-page":"292","DOI":"10.1016\/j.jemermed.2012.06.018","volume":"44","author":"WM Reisman","year":"2013","unstructured":"Reisman WM, Shuler MS, Kinsey TL, et al. Relationship between near infrared spectroscopy and intra-compartmental pressures. J Emerg Med. 2013;44:292\u20138. https:\/\/doi.org\/10.1016\/j.jemermed.2012.06.018.","journal-title":"J Emerg Med"},{"key":"6763_CR24","doi-asserted-by":"publisher","first-page":"838","DOI":"10.2106\/00004623-199706000-00006","volume":"79","author":"GA Briet","year":"1997","unstructured":"Briet GA, Gross JH, WATENPAUGH DE, et al. Near-infrared spectroscopy for monitoring of tissue oxygenation of exercising skeletal muscle in a chronic compartment syndrome model. JBJS. 1997;79:838\u201343.","journal-title":"JBJS"},{"key":"6763_CR25","doi-asserted-by":"publisher","DOI":"10.1097\/BPO.0b013e3180326591","author":"JD Tobias","year":"2007","unstructured":"Tobias JD, Hoernschemeyer DG. Near-infrared spectroscopy identifies compartment syndrome in an infant. J Pediatr Orthop. 2007. https:\/\/doi.org\/10.1097\/BPO.0b013e3180326591.","journal-title":"J Pediatr Orthop"},{"key":"6763_CR26","doi-asserted-by":"publisher","first-page":"836","DOI":"10.1053\/j.jvca.2010.06.023","volume":"25","author":"J de Sanchez Toledo","year":"2011","unstructured":"de Sanchez Toledo J, Chrysostomou C, Wearden PD. Acute compartment syndrome in a patient on extracorporeal support: utility of near-infrared spectroscopy. J Cardiothorac Vasc Anesth. 2011;25:836\u20137. https:\/\/doi.org\/10.1053\/j.jvca.2010.06.023.","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"6763_CR27","doi-asserted-by":"publisher","first-page":"e475","DOI":"10.1093\/milmed\/usy270","volume":"184","author":"D Aedo-Mart\u00edn","year":"2019","unstructured":"Aedo-Mart\u00edn D, Navarro-Suay R, Garc\u00eda-Ca\u00f1as R, et al. Use of oxygen tissue monitoring in patients with compartment syndrome: two clinical cases and literature review. Mil Med. 2019;184:e475\u20139. https:\/\/doi.org\/10.1093\/milmed\/usy270.","journal-title":"Mil Med"},{"key":"6763_CR28","doi-asserted-by":"publisher","first-page":"452","DOI":"10.1177\/0363546503261733","volume":"32","author":"JGH Van Den Brand","year":"2004","unstructured":"Van Den Brand JGH, Verleisdonk EJMM, Van Der Werken C. Near infrared spectroscopy in the diagnosis of chronic exertional compartment syndrome. Am J Sports Med. 2004;32:452\u20136. https:\/\/doi.org\/10.1177\/0363546503261733.","journal-title":"Am J Sports Med"},{"key":"6763_CR29","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-199706000-00007","author":"LR Mohler","year":"1997","unstructured":"Mohler LR, Styf JR, Pedowitz RA, et al. Intramuscular deoxygenation during exercise in patients who have chronic anterior compartment syndrome of the leg*. J Bone Joint Surg Am. 1997. https:\/\/doi.org\/10.2106\/00004623-199706000-00007.","journal-title":"J Bone Joint Surg Am"},{"key":"6763_CR30","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.N.01280","author":"K Rennerfelt","year":"2016","unstructured":"Rennerfelt K, Zhang Q, Karlsson J, Styf J. Changes in muscle oxygen saturation have low sensitivity in diagnosing chronic anterior compartment syndrome of the leg. J Bone Joint Surg Am. 2016. https:\/\/doi.org\/10.2106\/JBJS.N.01280.","journal-title":"J Bone Joint Surg Am"},{"key":"6763_CR31","doi-asserted-by":"publisher","first-page":"690","DOI":"10.1111\/j.1600-0838.2011.01392.x","volume":"22","author":"Q Zhang","year":"2012","unstructured":"Zhang Q, Rennerfelt K, Styf J. The magnitude of intramuscular deoxygenation during exercise is an unreliable measure to diagnose the cause of leg pain. Scand J Med Sci Sports. 2012;22:690\u20134. https:\/\/doi.org\/10.1111\/j.1600-0838.2011.01392.x.","journal-title":"Scand J Med Sci Sports"},{"key":"6763_CR32","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3233\/CH-2009-1145","volume":"41","author":"E Arat\u00f3","year":"2009","unstructured":"Arat\u00f3 E, K\u00fcrthy M, S\u00ednay L, et al. Pathology and diagnostic options of lower limb compartment syndrome. Clin Hemorheol Microcirc. 2009;41:1\u20138. https:\/\/doi.org\/10.3233\/CH-2009-1145.","journal-title":"Clin Hemorheol Microcirc"},{"key":"6763_CR33","doi-asserted-by":"publisher","first-page":"178","DOI":"10.3928\/01477447-20110124-12","volume":"34","author":"JT Bariteau","year":"2011","unstructured":"Bariteau JT, Beutel BG, Kamal R, et al. The use of near-infrared spectrometry for the diagnosis of lower-extremity compartment syndrome. Orthopedics. 2011;34:178. https:\/\/doi.org\/10.3928\/01477447-20110124-12.","journal-title":"Orthopedics"},{"key":"6763_CR34","doi-asserted-by":"publisher","first-page":"863","DOI":"10.2106\/JBJS.I.00816","volume":"92","author":"MS Shuler","year":"2010","unstructured":"Shuler MS, Reisman WM, Kinsey TL, et al. Correlation between muscle oxygenation and compartment pressures in acute compartment syndrome of the leg. J Bone Jt Surg-Am. 2010;92:863\u201370. https:\/\/doi.org\/10.2106\/JBJS.I.00816.","journal-title":"J Bone Jt Surg-Am"},{"key":"6763_CR35","doi-asserted-by":"publisher","first-page":"1506","DOI":"10.1016\/j.injury.2011.03.022","volume":"42","author":"MS Shuler","year":"2011","unstructured":"Shuler MS, Reisman WM, Cole AL, et al. Near-infrared spectroscopy in acute compartment syndrome: case report. Injury. 2011;42:1506\u20138. https:\/\/doi.org\/10.1016\/j.injury.2011.03.022.","journal-title":"Injury"},{"key":"6763_CR36","doi-asserted-by":"publisher","first-page":"787","DOI":"10.1302\/0301-620X.100B6.BJJ-2017-0736.R3","volume":"100-B","author":"MS Shuler","year":"2018","unstructured":"Shuler MS, Roskosky M, Kinsey T, et al. Continual near-infrared spectroscopy monitoring in the injured lower limb and acute compartment syndrome: an FDA-IDE trial. Bone Joint J. 2018;100-B:787\u201397. https:\/\/doi.org\/10.1302\/0301-620X.100B6.BJJ-2017-0736.R3.","journal-title":"Bone Joint J"},{"key":"6763_CR37","doi-asserted-by":"publisher","first-page":"539","DOI":"10.1088\/1361-6579\/aa5dd5","volume":"38","author":"VM Niemeijer","year":"2017","unstructured":"Niemeijer VM, Jansen JP, van Dijk T, et al. The influence of adipose tissue on spatially resolved near-infrared spectroscopy derived skeletal muscle oxygenation: the extent of the problem. Physiol Meas. 2017;38:539. https:\/\/doi.org\/10.1088\/1361-6579\/aa5dd5.","journal-title":"Physiol Meas"},{"key":"6763_CR38","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1042\/cs20000247","volume":"101","author":"MC van Beekvelt","year":"1979","unstructured":"van Beekvelt MC, Borghuis MS, van Engelen BG, et al. (2001) Adipose tissue thickness affects in vivo quantitative near-IR spectroscopy in human skeletal muscle. Clin Sci Lond Engl. 1979;101:21\u20138. https:\/\/doi.org\/10.1042\/cs20000247.","journal-title":"Clin Sci Lond Engl"},{"key":"6763_CR39","doi-asserted-by":"publisher","first-page":"S33310","DOI":"10.1117\/1.JBO.29.S3.S33310","volume":"29","author":"S Roy","year":"2024","unstructured":"Roy S, Wu J, Cao J, et al. Exploring the impact and influence of melanin on frequency-domain near-infrared spectroscopy measurements. J Biomed Opt. 2024;29:S33310. https:\/\/doi.org\/10.1117\/1.JBO.29.S3.S33310.","journal-title":"J Biomed Opt"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13018-026-06763-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-026-06763-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-026-06763-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,30]],"date-time":"2026-03-30T14:55:16Z","timestamp":1774882516000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s13018-026-06763-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,23]]},"references-count":39,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["6763"],"URL":"https:\/\/doi.org\/10.1186\/s13018-026-06763-x","relation":{},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,23]]},"assertion":[{"value":"16 December 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 February 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 February 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"All authors have consented for publication.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"227"}}