{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,17]],"date-time":"2026-04-17T02:00:38Z","timestamp":1776391238561,"version":"3.51.2"},"reference-count":38,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,3,11]],"date-time":"2026-03-11T00:00:00Z","timestamp":1773187200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,4,17]],"date-time":"2026-04-17T00:00:00Z","timestamp":1776384000000},"content-version":"vor","delay-in-days":37,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"DOI":"10.1186\/s13018-026-06773-9","type":"journal-article","created":{"date-parts":[[2026,3,11]],"date-time":"2026-03-11T02:48:01Z","timestamp":1773197281000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Safety and efficacy of the polymer enhanced AS-ELARIS\u00ae pedicle screw system using ultrasonically liquefied polylactide: a short-, mid-, and long-term posterolateral fusion study in sheep"],"prefix":"10.1186","volume":"21","author":[{"given":"Isabel","family":"Heel","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Agnieszka A.","family":"Karol","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7689-7534","authenticated-orcid":false,"given":"Peter W. M.","family":"Kronen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Brigitte","family":"von Rechenberg","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6878-5583","authenticated-orcid":false,"given":"Karina","family":"Klein","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2026,3,11]]},"reference":[{"issue":"2","key":"6773_CR1","first-page":"135","volume":"121","author":"R Cailliet","year":"1974","unstructured":"Cailliet R. Low back pain. Western J Med. 1974;121(2):135.","journal-title":"Western J Med"},{"issue":"4","key":"6773_CR2","doi-asserted-by":"publisher","first-page":"785","DOI":"10.1016\/S1042-3680(18)30700-9","volume":"2","author":"AL Nachemson","year":"1991","unstructured":"Nachemson AL. Instability of the lumbar spine: pathology, treatment, and clinical evaluation. Neurosurg Clin North Am. 1991;2(4):785\u201390.","journal-title":"Neurosurg Clin North Am"},{"issue":"sup281","key":"6773_CR3","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1080\/17453674.1998.11744790","volume":"69","author":"GB Andersson","year":"1998","unstructured":"Andersson GB. Epidemiology of low back pain. Acta Orthop Scand. 1998;69(sup281):28\u201331.","journal-title":"Acta Orthop Scand"},{"issue":"3","key":"6773_CR4","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1016\/j.jphys.2019.04.010","volume":"65","author":"T da Silva","year":"2019","unstructured":"da Silva T, Mills K, Brown BT, Pocovi N, de Campos T, Maher C, et al. Recurrence of low back pain is common: a prospective inception cohort study. J Physiother. 2019;65(3):159\u201365.","journal-title":"J Physiother"},{"issue":"4","key":"6773_CR5","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1016\/S1050-6411(03)00044-0","volume":"13","author":"MM Panjabi","year":"2003","unstructured":"Panjabi MM. Clinical spinal instability and low back pain. J Electromyogr Kinesiol. 2003;13(4):371\u20139.","journal-title":"J Electromyogr Kinesiol"},{"issue":"1","key":"6773_CR6","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1097\/01.BRS.0000103942.81227.7F","volume":"29","author":"JA Kopec","year":"2004","unstructured":"Kopec JA, Sayre EC, Esdaile JM. Predictors of back pain in a general population cohort. Spine. 2004;29(1):70\u20137.","journal-title":"Spine"},{"issue":"4","key":"6773_CR7","doi-asserted-by":"publisher","first-page":"777","DOI":"10.1016\/j.mcna.2014.03.005","volume":"98","author":"N Patrick","year":"2014","unstructured":"Patrick N, Emanski E, Knaub MA. Acute and chronic low back pain. Med Clin North Am. 2014;98(4):777\u201389.","journal-title":"Med Clin North Am"},{"key":"6773_CR8","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1016\/j.tvjl.2016.12.007","volume":"220","author":"M Teunissen","year":"2017","unstructured":"Teunissen M, Van Der Veen A, Smit T, Tryfonidou M, Meij B. Effect of a titanium cage as a stand-alone device on biomechanical stability in the lumbosacral spine of canine cadavers. Vet J. 2017;220:17\u201323.","journal-title":"Vet J"},{"issue":"8","key":"6773_CR9","doi-asserted-by":"publisher","first-page":"1063","DOI":"10.1007\/s00402-016-2487-8","volume":"136","author":"J Bredow","year":"2016","unstructured":"Bredow J, Boese CK, Werner CM, Siewe J, Lohrer L, Zarghooni K, et al. Predictive validity of preoperative CT scans and the risk of pedicle screw loosening in spinal surgery. Arch Orthop Trauma Surg. 2016;136(8):1063\u20137.","journal-title":"Arch Orthop Trauma Surg"},{"issue":"12","key":"6773_CR10","doi-asserted-by":"publisher","first-page":"2673","DOI":"10.1002\/jor.23575","volume":"35","author":"HB Pearson","year":"2017","unstructured":"Pearson HB, Dobbs CJ, Grantham E, Niebur GL, Chappuis JL, Boerckel JD. Intraoperative biomechanics of lumbar pedicle screw loosening following successful arthrodesis. J Orthop Res. 2017;35(12):2673\u201381.","journal-title":"J Orthop Res"},{"key":"6773_CR11","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1016\/j.medengphy.2016.11.012","volume":"40","author":"V Varghese","year":"2017","unstructured":"Varghese V, Saravana Kumar G, Krishnan V. Effect of various factors on pull out strength of pedicle screw in normal and osteoporotic cancellous bone models. Med Eng Phys. 2017;40:28\u201338.","journal-title":"Med Eng Phys"},{"issue":"4","key":"6773_CR12","doi-asserted-by":"publisher","first-page":"607","DOI":"10.3233\/THC-140815","volume":"22","author":"H Goost","year":"2014","unstructured":"Goost H, Deborre C, Wirtz D, Burger C, Prescher A, F\u00f6lsch C, et al. PMMA-augmentation of incompletely cannulated pedicle screws: a cadaver study to determine the benefits in the osteoporotic spine. Technol Health Care. 2014;22(4):607\u201315.","journal-title":"Technol Health Care"},{"issue":"1","key":"6773_CR13","doi-asserted-by":"publisher","first-page":"3","DOI":"10.4184\/asj.2018.12.1.3","volume":"12","author":"G Kiyak","year":"2018","unstructured":"Kiyak G, Balikci T, Heydar AM, Bezer M. Comparison of the pullout strength of different pedicle screw designs and augmentation techniques in an osteoporotic bone model. Asian spine J. 2018;12(1):3.","journal-title":"Asian spine J"},{"issue":"3","key":"6773_CR14","doi-asserted-by":"publisher","first-page":"238","DOI":"10.1016\/j.clinbiomech.2010.10.008","volume":"26","author":"M Gao","year":"2011","unstructured":"Gao M, Lei W, Wu Z, Liu D, Shi L. Biomechanical evaluation of fixation strength of conventional and expansive pedicle screws with or without calcium based cement augmentation. Clin Biomech Elsevier Ltd. 2011;26(3):238\u201344.","journal-title":"Clin Biomech Elsevier Ltd"},{"issue":"2","key":"6773_CR15","doi-asserted-by":"publisher","first-page":"e0229328","DOI":"10.1371\/journal.pone.0229328","volume":"15","author":"M-Y Liu","year":"2020","unstructured":"Liu M-Y, Tsai T-T, Lai P-L, Hsieh M-K, Chen L-H, Tai C-L. Biomechanical comparison of pedicle screw fixation strength in synthetic bones: Effects of screw shape, core\/thread profile and cement augmentation. PLoS ONE. 2020;15(2):e0229328.","journal-title":"PLoS ONE"},{"issue":"24","key":"6773_CR16","doi-asserted-by":"publisher","first-page":"2618","DOI":"10.1097\/BRS.0b013e3181882cac","volume":"33","author":"DW Kiner","year":"2008","unstructured":"Kiner DW, Wybo CD, Sterba W, Yeni YN, Bartol SW, Vaidya R. Biomechanical analysis of different techniques in revision spinal instrumentation: larger diameter screws: versus: cement augmentation. Spine. 2008;33(24):2618\u201322.","journal-title":"Spine"},{"key":"6773_CR17","first-page":"278","volume":"296","author":"RH Wittenberg","year":"1993","unstructured":"Wittenberg RH, Lee K-S, Shea M, White AAI, Hayes WC. Effect of screw diameter, insertion technique, and bone cement augmentation of pedicular screw fixation strength. Clin Orthop Relat Res\u00ae. 1993;296:278\u201387.","journal-title":"Clin Orthop Relat Res\u00ae"},{"issue":"1","key":"6773_CR18","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1302\/0301-620X.76B1.8300663","volume":"76","author":"R Wilkes","year":"1994","unstructured":"Wilkes R, Mackinnon J, Thomas W. Neurological deterioration after cement injection into a vertebral body. J bone joint Surg Br volume. 1994;76(1):155.","journal-title":"J bone joint Surg Br volume"},{"issue":"1","key":"6773_CR19","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1007\/s00776-004-0862-8","volume":"10","author":"M Yazu","year":"2005","unstructured":"Yazu M, Kin A, Kosaka R, Kinoshita M, Abe M. Efficacy of novel-concept pedicle screw fixation augmented with calcium phosphate cement in the osteoporotic spine. J Orthop Sci. 2005;10(1):56\u201361.","journal-title":"J Orthop Sci"},{"issue":"2","key":"6773_CR20","doi-asserted-by":"publisher","first-page":"117","DOI":"10.1055\/s-0043-1761943","volume":"85","author":"P Lenga","year":"2024","unstructured":"Lenga P, Bajwa AA, Schneider T, Iwanaga J, Tubbs RS, Kiening KL, et al. High rate of pulmonary cement embolism after cement-augmented pedicle screw fixation: a 12-year single-center study. J Neurol Surg Cent Eur Neurosurg. 2024;85(2):117\u201325.","journal-title":"J Neurol Surg Cent Eur Neurosurg"},{"issue":"1","key":"6773_CR21","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1002\/jbm.b.30427","volume":"77","author":"SJ Ferguson","year":"2006","unstructured":"Ferguson SJ, Weber U, von Rechenberg B, Mayer J. Enhancing the mechanical integrity of the implant-bone interface with BoneWelding technology: determination of quasi-static interfacial strength and fatigue resistance. J Biomed Mater Res B Appl Biomater. 2006;77(1):13\u201320.","journal-title":"J Biomed Mater Res B Appl Biomater"},{"issue":"6","key":"6773_CR22","doi-asserted-by":"publisher","first-page":"817","DOI":"10.3390\/polym16060817","volume":"16","author":"M Nonhoff","year":"2024","unstructured":"Nonhoff M, Puetzler J, Hasselmann J, Fobker M, Gosheger G, Schulze M. The Potential for foreign body reaction of implanted poly-l-lactic acid: a systematic review. Polym (Basel). 2024;16(6):817.","journal-title":"Polym (Basel)"},{"issue":"11","key":"6773_CR23","doi-asserted-by":"publisher","first-page":"1821","DOI":"10.1007\/s00586-011-1799-1","volume":"20","author":"D Heidenreich","year":"2011","unstructured":"Heidenreich D, Langhoff JD, Nuss K, Kluge K, K\u00e4mpf K, Zlinsky K, et al. The use of BoneWelding\u00ae technology in spinal surgery: an experimental study in sheep. Eur Spine J. 2011;20(11):1821\u201336.","journal-title":"Eur Spine J"},{"key":"6773_CR24","doi-asserted-by":"publisher","first-page":"40","DOI":"10.2174\/1874325000903010040","volume":"3","author":"JD Langhoff","year":"2009","unstructured":"Langhoff JD, Kuemmerle JM, Mayer J, Weber U, Berra M, Mueller JM, et al. An ultrasound assisted anchoring technique (Bonewelding\u00ae technology) for fixation of implants to bone\u2013a histological pilot study in sheep. open Orthop J. 2009;3:40.","journal-title":"open Orthop J"},{"issue":"1","key":"6773_CR25","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1016\/0022-3913(83)90174-9","volume":"50","author":"A Eriksson","year":"1983","unstructured":"Eriksson A, Albrektsson T. Temperature threshold levels for heat-induced bone tissue injury: a vital-microscopic study in the rabbit. J Prosthet Dent. 1983;50(1):101\u20137.","journal-title":"J Prosthet Dent"},{"issue":"1","key":"6773_CR26","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/1471-2474-14-200","volume":"14","author":"K Klein","year":"2013","unstructured":"Klein K, Zamparo E, Kronen PW, K\u00e4mpf K, Makara M, Steffen T, et al. Bone augmentation for cancellous bone-development of a new animal model. BMC Musculoskelet Disord. 2013;14(1):1\u201313.","journal-title":"BMC Musculoskelet Disord"},{"issue":"4","key":"6773_CR27","doi-asserted-by":"publisher","first-page":"325","DOI":"10.1007\/s005860000232","volume":"10","author":"H Defino","year":"2001","unstructured":"Defino H, Vendrame J. Role of cortical and cancellous bone of the vertebral pedicle in implant fixation. Eur Spine J. 2001;10(4):325\u201333.","journal-title":"Eur Spine J"},{"issue":"8","key":"6773_CR28","doi-asserted-by":"publisher","first-page":"822","DOI":"10.1016\/j.medengphy.2010.05.005","volume":"32","author":"PS Patel","year":"2010","unstructured":"Patel PS, Shepherd DE, Hukins DW. The effect of screw insertion angle and thread type on the pullout strength of bone screws in normal and osteoporotic cancellous bone models. Med Eng Phys. 2010;32(8):822\u20138.","journal-title":"Med Eng Phys"},{"issue":"37","key":"6773_CR29","doi-asserted-by":"publisher","first-page":"E674","DOI":"10.1073\/pnas.1107019108","volume":"108","author":"JD Boerckel","year":"2011","unstructured":"Boerckel JD, Uhrig BA, Willett NJ, Huebsch N, Guldberg RE. Mechanical regulation of vascular growth and tissue regeneration in vivo. Proc National Acad Sci. 2011;108(37):E674-80.","journal-title":"Proc National Acad Sci"},{"issue":"7","key":"6773_CR30","doi-asserted-by":"publisher","first-page":"735","DOI":"10.1097\/01.BRS.0000112072.83196.0F","volume":"29","author":"P Korovessis","year":"2004","unstructured":"Korovessis P, Papazisis Z, Koureas G, Lambiris E. Rigid, semirigid versus dynamic instrumentation for degenerative lumbar spinal stenosis: a correlative radiological and clinical analysis of short-term results. Spine. 2004;29(7):735\u201342.","journal-title":"Spine"},{"issue":"1","key":"6773_CR31","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1016\/j.smallrumres.2005.07.028","volume":"62","author":"J Fitzpatrick","year":"2006","unstructured":"Fitzpatrick J, Scott M, Nolan A. Assessment of pain and welfare in sheep. Small Ruminant Res. 2006;62(1):55\u201361.","journal-title":"Small Ruminant Res"},{"issue":"5","key":"6773_CR32","doi-asserted-by":"publisher","first-page":"839","DOI":"10.1001\/archsurg.1966.01330050143023","volume":"93","author":"RK KULKARNI","year":"1966","unstructured":"Kulkarni RK, Pani KC. Polylactic acid for surgical implants. Arch Surg. 1966;93(5):839\u201343.","journal-title":"Arch Surg"},{"key":"6773_CR33","doi-asserted-by":"publisher","first-page":"28","DOI":"10.22141\/2224-1507.9.1.2019.163056","volume":"9","author":"N Dedukh","year":"2019","unstructured":"Dedukh N, Makarov V, Pavlov A. Polylactide-based biomaterial and its use as bone implants (analytical literature review). Pain Jt Spine. 2019;9:28\u201335.","journal-title":"Pain Jt Spine"},{"issue":"2","key":"6773_CR34","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1016\/S0142-9612(03)00496-4","volume":"25","author":"A Prokop","year":"2004","unstructured":"Prokop A, Jubel A, Helling H, Eibach T, Peters C, Baldus S, et al. Soft tissue reactions of different biodegradable polylactide implants. Biomaterials. 2004;25(2):259\u201367.","journal-title":"Biomaterials"},{"issue":"8443","key":"6773_CR35","doi-asserted-by":"publisher","first-page":"1422","DOI":"10.1016\/S0140-6736(85)91847-1","volume":"325","author":"P Rokkanen","year":"1985","unstructured":"Rokkanen P, Vainionp\u00e4\u00e4 S, T\u00f6rm\u00e4l\u00e4 P, Kilpikari J, B\u00f6stman O, Vihtonen K, et al. Biodegradable implants in fracture fixation: early results of treatment of fractures of the ankle. lancet. 1985;325(8443):1422\u20134.","journal-title":"lancet"},{"issue":"1","key":"6773_CR36","doi-asserted-by":"publisher","first-page":"148","DOI":"10.2106\/00004623-199173010-00022","volume":"73","author":"O B\u00f6stman","year":"1991","unstructured":"B\u00f6stman O. Absorbable implants for the fixation of fractures. JBJS. 1991;73(1):148\u201353.","journal-title":"JBJS"},{"issue":"3","key":"6773_CR37","doi-asserted-by":"publisher","first-page":"305","DOI":"10.1016\/S0749-8063(00)90055-0","volume":"16","author":"A Weiler","year":"2000","unstructured":"Weiler A, Hoffmann RF, Stahelin AC, Helling HJ, Sudkamp NP. Biodegradable implants in sports medicine: the biological base. Arthroscopy. 2000;16(3):305\u201321.","journal-title":"Arthroscopy"},{"issue":"12","key":"6773_CR38","doi-asserted-by":"publisher","first-page":"1803","DOI":"10.1016\/j.jbiomech.2004.03.002","volume":"37","author":"M Sta\u0144czyk","year":"2004","unstructured":"Sta\u0144czyk M, Van Rietbergen B. Thermal analysis of bone cement polymerisation at the cement\u2013bone interface. J Biomech. 2004;37(12):1803\u201310.","journal-title":"J Biomech"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13018-026-06773-9","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-026-06773-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-026-06773-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,17]],"date-time":"2026-04-17T01:31:53Z","timestamp":1776389513000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s13018-026-06773-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,11]]},"references-count":38,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["6773"],"URL":"https:\/\/doi.org\/10.1186\/s13018-026-06773-9","relation":{},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,11]]},"assertion":[{"value":"25 September 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 February 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 March 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All animal experiments were conducted according to the Swiss laws of animal protection and welfare and were approved by the local governmental veterinary authorities (license number: ZH013\/16).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"265"}}