{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,21]],"date-time":"2026-04-21T01:43:47Z","timestamp":1776735827959,"version":"3.51.2"},"reference-count":40,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,3,13]],"date-time":"2026-03-13T00:00:00Z","timestamp":1773360000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,4,21]],"date-time":"2026-04-21T00:00:00Z","timestamp":1776729600000},"content-version":"vor","delay-in-days":39,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"DOI":"10.1186\/s13018-026-06784-6","type":"journal-article","created":{"date-parts":[[2026,3,13]],"date-time":"2026-03-13T05:33:20Z","timestamp":1773380000000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Parallel versus non-parallel cannulated screw fixation for femoral neck fractures: a systematic review and meta-analysis"],"prefix":"10.1186","volume":"21","author":[{"given":"Mingwang","family":"Jia","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chenning","family":"Ding","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xing","family":"Han","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jiahui","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xin","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhiyong","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiguang","family":"Sang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2026,3,13]]},"reference":[{"key":"6784_CR1","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/S0020-1383(02)00324-8","volume":"33","author":"KG Thorngren","year":"2002","unstructured":"Thorngren KG, Hommel A, Norrman PO, et al. Epidemiology of femoral neck fractures. Injury. 2002;33:1\u20137.","journal-title":"Injury"},{"key":"6784_CR2","doi-asserted-by":"publisher","first-page":"1726","DOI":"10.1007\/s00198-006-0172-4","volume":"17","author":"O Johnell","year":"2006","unstructured":"Johnell O, Kanis JA. An estimate of the worldwide prevalence and disability associated with osteoporotic fractures. Osteoporos Int. 2006;17:1726\u201333.","journal-title":"Osteoporos Int"},{"issue":"21","key":"6784_CR3","doi-asserted-by":"publisher","first-page":"2053","DOI":"10.1056\/NEJMcp1611090","volume":"377","author":"M Bhandari","year":"2017","unstructured":"Bhandari M, Swiontkowski M. Management of acute hip fracture. N Engl J Med. 2017;377(21):2053\u201362.","journal-title":"N Engl J Med"},{"issue":"1","key":"6784_CR4","doi-asserted-by":"publisher","first-page":"758","DOI":"10.1038\/s41598-020-57696-2","volume":"10","author":"N Ramadanov","year":"2020","unstructured":"Ramadanov N, Toma I, Herkner H, et al. Factors that influence the complications and outcomes of femoral neck fractures treated by cannulated screw fixation. Sci Rep. 2020;10(1):758.","journal-title":"Sci Rep"},{"issue":"1","key":"6784_CR5","doi-asserted-by":"publisher","first-page":"625","DOI":"10.1186\/s13018-023-04114-8","volume":"18","author":"N Ramadanov","year":"2023","unstructured":"Ramadanov N, J\u00f3\u017awiak K, Hauptmann M, et al. Cannulated screws versus dynamic hip screw versus hemiarthroplasty versus total hip arthroplasty in patients with displaced and non-displaced femoral neck fractures: a systematic review and frequentist network meta-analysis of 5703 patients. J Orthop Surg Res. 2023;18(1):625.","journal-title":"J Orthop Surg Res"},{"issue":"3","key":"6784_CR6","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1097\/BOT.0000000000000291","volume":"29","author":"AV Florschutz","year":"2015","unstructured":"Florschutz AV, Langford JR, Haidukewych GJ, et al. Femoral neck fractures: current management. J Orthop Trauma. 2015;29(3):121\u20139.","journal-title":"J Orthop Trauma"},{"issue":"1","key":"6784_CR7","first-page":"131","volume":"36","author":"DS Damany","year":"2005","unstructured":"Damany DS, Parker MJ, Chojnowski A. Complications after intracapsular hip fractures in young adults: a meta-analysis of 18 published studies involving 564 fractures. Injury. 2005;36(1):131\u201341.","journal-title":"Injury"},{"key":"6784_CR8","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s13018-021-02619-8","volume":"16","author":"D Jiang","year":"2021","unstructured":"Jiang D, Zhan S, Cai Q, et al. Enhanced interfragmentary stability and improved clinical prognosis with use of the off-axis screw technique to treat vertical femoral neck fractures in nongeriatric patients. J Orthop Surg Res. 2021;16:1\u201311.","journal-title":"J Orthop Surg Res"},{"issue":"4","key":"6784_CR9","doi-asserted-by":"publisher","first-page":"595","DOI":"10.1111\/os.12503","volume":"11","author":"Q Dong","year":"2019","unstructured":"Dong Q, Han Z, Zhang YG, et al. Comparison of transverse cancellous lag screw and ordinary cannulated screw fixations in treatment of vertical femoral neck fractures. Orthop Surg. 2019;11(4):595\u2013603.","journal-title":"Orthop Surg"},{"issue":"1","key":"6784_CR10","doi-asserted-by":"publisher","first-page":"350","DOI":"10.1186\/s12891-023-06297-x","volume":"24","author":"M Wang","year":"2023","unstructured":"Wang M, Wang Y, Zou F, et al. Mechanical study of the application of compression screw nails in the cross-inverted triangular pattern for internal fixation of femoral neck fractures. BMC Musculoskelet Disord. 2023;24(1):350.","journal-title":"BMC Musculoskelet Disord"},{"key":"6784_CR11","unstructured":"Page MJ, McKenzie JE, Bossuyt PM et al. The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. Int J Surg. 2021: 88105906."},{"key":"6784_CR12","doi-asserted-by":"publisher","first-page":"j4008","DOI":"10.1136\/bmj.j4008","volume":"358","author":"BJ Shea","year":"2017","unstructured":"Shea BJ, Reeves BC, Wells G, et al. AMSTAR 2: a critical appraisal tool for systematic reviews that include randomised or non-randomised studies of healthcare interventions, or both. BMJ. 2017;358:j4008.","journal-title":"BMJ"},{"issue":"4","key":"6784_CR13","doi-asserted-by":"publisher","first-page":"e376","DOI":"10.3928\/01477447-20190321-03","volume":"42","author":"DJ Stockton","year":"2019","unstructured":"Stockton DJ, Dua K, O\u2019Brien PJ, et al. Failure patterns of femoral neck fracture fixation in young patients . Orthopedics. 2019;42(4):e376\u201380.","journal-title":"Orthopedics"},{"key":"6784_CR14","unstructured":"Higgins JPT, Thomas J, Chandler J, Cumpston M, Li T, Page MJ, Welch VA, editors. Cochrane Handbook for Systematic Reviews of Interventions version 6.5 (updated August 2024). Cochrane, 2024. Available from www.training.cochrane.org\/handbook"},{"issue":"11","key":"6784_CR15","doi-asserted-by":"publisher","first-page":"1539","DOI":"10.1002\/sim.1186","volume":"21","author":"JPT Higgins","year":"2002","unstructured":"Higgins JPT, Thompson SG. Quantifying heterogeneity in a meta-analysis. Stat Med. 2002;21(11):1539\u201358.","journal-title":"Stat Med"},{"key":"6784_CR16","doi-asserted-by":"crossref","unstructured":"Ramadanov N, Voss M, Diallo RM, et al. Do meta-analyses of total hip arthroplasty produce reliable results? A systematic review and meta\u2010epidemiological study of statistical methods. Orthopaedic Surgery; 2025.","DOI":"10.1111\/os.70077"},{"issue":"10","key":"6784_CR17","first-page":"1921","volume":"29","author":"Z Wang","year":"2024","unstructured":"Wang Z, Wang FX. Effect of non-parallel hollow screws in the treatment of femoral neck fracture. Zhejiang J Trauma Surg. 2024;29(10):1921\u20133.","journal-title":"Zhejiang J Trauma Surg"},{"issue":"08","key":"6784_CR18","first-page":"961","volume":"38","author":"YH Zhou","year":"2024","unstructured":"Zhou YH, Li L, Li C, Li M, et al. Effectiveness analysis of biplanar vertical fixation and inverted triangle fixation with hollow screw for Pauwels type \u2162 femoral neck fracture in young and middle-aged patients. Chin J Reparative Reconstr Surg. 2024;38(08):961\u20137.","journal-title":"Chin J Reparative Reconstr Surg"},{"issue":"04","key":"6784_CR19","first-page":"412","volume":"38","author":"YH Liu","year":"2024","unstructured":"Liu YH, Ma WL, Tian KW, et al. Comparison of effectiveness of three surgical methods in treatment of Pauwels type \u2162 femoral neck fracture in young and middle-aged patients. Chin J Reparative Reconstr Surg. 2024;38(04):412\u201321.","journal-title":"Chin J Reparative Reconstr Surg"},{"issue":"2","key":"6784_CR20","first-page":"129","volume":"37","author":"XL Zhao","year":"2024","unstructured":"Zhao XL, Shen JJ, Feng KH, et al. Comparison of the efficacy of TiRobot orthopaedic robot assisted F screw technique and inverted triangle parallel nail internal fixation in the treatment of unstable femoral neck fractures. China J Orthop Traumatol. 2024;37(2):129\u201334.","journal-title":"China J Orthop Traumatol"},{"issue":"06","key":"6784_CR21","first-page":"449","volume":"23","author":"ZZ Cui","year":"2023","unstructured":"Cui ZZ, Xu XY, Cao Y, et al. Comparison of Four Non-parallel Cannulated Screws and Three Parallel Cannulated Screws in the Treatment of Femoral Neck Fracture. Chin J Minim Invasive Surg. 2023;23(06):449\u201355.","journal-title":"Chin J Minim Invasive Surg"},{"issue":"04","key":"6784_CR22","first-page":"26","volume":"19","author":"M Shen","year":"2022","unstructured":"Shen M, Cao XD, Gu JW, et al. Analysis of the effect of biplane fixation in the stabilization and optimization of femoral neck fracture. Orthop Biomech Mater Clin Study. 2022;19(04):26\u201330.","journal-title":"Orthop Biomech Mater Clin Study"},{"issue":"7","key":"6784_CR23","first-page":"678","volume":"35","author":"WJ Cheng","year":"2022","unstructured":"Cheng WJ, Ding GZ, Xie JB, et al. Comparison of curative effect between F shaped hollow screw and traditional three parallel screws in the treatment of Pauwels type \u2162 femoral neck fracture. China J Orthop Traumatol. 2022;35(7):678\u201382.","journal-title":"China J Orthop Traumatol"},{"key":"6784_CR24","unstructured":"Tian B. Biomechanical analysis and clinical study of different screw configurations in the treatment of Pauwels type \u2162 femoral neck fractures. Jilin University; 2022."},{"issue":"4","key":"6784_CR25","first-page":"249","volume":"11","author":"B Wang","year":"2022","unstructured":"Wang B, Chen JL, Yu GR, et al. Comparison of transverse cancellous bone lag screw and ordinary hollow screw in the treatment of femoral neck fracture. Chin J Bone Joint. 2022;11(4):249\u201354.","journal-title":"Chin J Bone Joint"},{"issue":"6","key":"6784_CR26","first-page":"543","volume":"30","author":"Z Guo","year":"2022","unstructured":"Guo Z, Li B, Yao MW, et al. Comparison of interlocking versus parallel cannulated screws for internal fixation of Garden type I and II femoral neck fractures. Orthop J China. 2022;30(6):543\u20136.","journal-title":"Orthop J China"},{"issue":"8","key":"6784_CR27","first-page":"113","volume":"33","author":"YL He","year":"2022","unstructured":"He YL, Li Q, Li GL. Comparison of the Effect ofFShaped Hollow nail and Hollow Screw Internal Fixation on Femoral Neck Fracture. Med Inform. 2022;33(8):113\u20135.","journal-title":"Med Inform"},{"key":"6784_CR28","unstructured":"Bai P. Biomechanical analysis of 3 and 4 cannulated screws for the treatment of Pauwels III femoral neck fracture and its influence on the prognosis of the fracture. Kunming Medical University; 2017."},{"issue":"24","key":"6784_CR29","first-page":"2242","volume":"24","author":"J Wang","year":"2016","unstructured":"Wang J, Ran J, Liu XX, et al. Therapeutic effect of cannulated screws placed with F - technique versus inverted triangle arrangement in treatment of femoral neck fracture. Orthop J China. 2016;24(24):2242\u20136.","journal-title":"Orthop J China"},{"key":"6784_CR30","doi-asserted-by":"crossref","unstructured":"Papanastassiou ID, Mavrogenis AF, Kokkalis ZT et al. Fixation of femoral neck fractures using divergent versus parallel cannulated screws. J Long Term Eff Med Implants, 2011, 21(1).","DOI":"10.1615\/JLongTermEffMedImplants.v21.i1.50"},{"key":"6784_CR31","doi-asserted-by":"publisher","first-page":"826159","DOI":"10.3389\/fsurg.2022.826159","volume":"9","author":"X Xu","year":"2022","unstructured":"Xu X, Lv Y, Cui Z, et al. Non-sliding fixation shows improved clinical outcomes for displaced femoral neck fractures as compared to sliding fixation. Front Surg. 2022;9:826159.","journal-title":"Front Surg"},{"issue":"12","key":"6784_CR32","doi-asserted-by":"publisher","first-page":"2011","DOI":"10.1007\/s43465-023-01006-1","volume":"57","author":"S Garg","year":"2023","unstructured":"Garg S, Tank G. Role of biplane double-supported screw fixation (BDSF) in management of fracture neck femur and its comparison with conventional CC screw fixation. Indian J Orthop. 2023;57(12):2011\u20137.","journal-title":"Indian J Orthop"},{"issue":"2","key":"6784_CR33","doi-asserted-by":"publisher","first-page":"230949901984025","DOI":"10.1177\/2309499019840252","volume":"27","author":"Y Wu","year":"2019","unstructured":"Wu Y, Leu TH, Chuang TY, et al. Screw trajectory affects screw cut-out risk after fixation for nondisplaced femoral neck fracture in elderly patients. J Orthop Surg. 2019;27(2):2309499019840252.","journal-title":"J Orthop Surg"},{"key":"6784_CR34","doi-asserted-by":"crossref","unstructured":"Cao D, Yin J, Yu P, et al. Treatment of Pauwels III femoral neck fracture in young patients using biplane double support screw internal fixation technology based on X-ray image. Volume 125. Medical Engineering & Physics; 2024. p. 104135.","DOI":"10.1016\/j.medengphy.2024.104135"},{"key":"6784_CR35","doi-asserted-by":"publisher","first-page":"S28","DOI":"10.1097\/BOT.0000000000000467","volume":"29","author":"M Bottlang","year":"2015","unstructured":"Bottlang M, Schemitsch CE, Nauth A, et al. Biomechanical concepts for fracture fixation. J Orthop Trauma. 2015;29:S28\u201333.","journal-title":"J Orthop Trauma"},{"key":"6784_CR36","doi-asserted-by":"crossref","unstructured":"Bray TJ. Femoral Neck Fracture Fixation: clinical decision making. Clinical Orthopaedics and Related Research (1976\u20132007), 1997, 339: 20\u201331.","DOI":"10.1097\/00003086-199706000-00004"},{"key":"6784_CR37","doi-asserted-by":"crossref","unstructured":"Tianye L, Peng Y, Jingli X, et al. Finite element analysis of different internal fixation methods for the treatment of Pauwels type III femoral neck fracture. Volume 112. Biomedicine & Pharmacotherapy; 2019. p. 108658.","DOI":"10.1016\/j.biopha.2019.108658"},{"key":"6784_CR38","doi-asserted-by":"publisher","first-page":"S1","DOI":"10.1097\/BOT.0000000000001369","volume":"33","author":"S Medda","year":"2019","unstructured":"Medda S, Snoap T, Carroll EA. Treatment of young femoral neck fractures. J Orthop Trauma. 2019;33:S1\u20136.","journal-title":"J Orthop Trauma"},{"issue":"1","key":"6784_CR39","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1097\/01.ta.0000241143.71274.63","volume":"64","author":"M Zlowodzki","year":"2008","unstructured":"Zlowodzki M, Ayieni O, Petrisor BA, et al. Femoral neck shortening after fracture fixation with multiple cancellous screws: incidence and effect on function. J Trauma Acute Care Surg. 2008;64(1):163\u20139.","journal-title":"J Trauma Acute Care Surg"},{"issue":"10","key":"6784_CR40","doi-asserted-by":"publisher","first-page":"487","DOI":"10.1097\/BOT.0000000000001551","volume":"33","author":"J Felton","year":"2019","unstructured":"Felton J, Slobogean GP, Jackson SS, et al. Femoral neck shortening after hip fracture fixation is associated with inferior hip function: results from the FAITH trial. J Orthop Trauma. 2019;33(10):487\u201396.","journal-title":"J Orthop Trauma"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13018-026-06784-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-026-06784-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-026-06784-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,21]],"date-time":"2026-04-21T01:35:36Z","timestamp":1776735336000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s13018-026-06784-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,13]]},"references-count":40,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["6784"],"URL":"https:\/\/doi.org\/10.1186\/s13018-026-06784-6","relation":{},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,13]]},"assertion":[{"value":"30 December 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 February 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 March 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"270"}}