{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,2]],"date-time":"2026-05-02T15:26:48Z","timestamp":1777735608295,"version":"3.51.4"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,4,5]],"date-time":"2026-04-05T00:00:00Z","timestamp":1775347200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T00:00:00Z","timestamp":1777420800000},"content-version":"vor","delay-in-days":24,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Proximal humerus fractures are common injuries in the elderly, frequently treated with plate osteosynthesis. Intraoperative 2D fluoroscopy provides only limited visualization of the humeral head\u2019s complex anatomy, often leading to undetected intra-articular screw perforations. Intraoperative 3D imaging provides enhanced assessment but is technically limited by the confined operating field and the risk of collisions between the C-arm, patient, and operating table. This cadaveric study systematically investigated how progressive reduction of orbital rotation during intraoperative 3D imaging of the proximal humerus affects image quality and intra-articular screw detection accuracy in plate osteosynthesis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Five fresh-frozen cadaveric shoulders were scanned using an isocentric C-arm. Full 200\u00b0 scans served as the gold standard. From these datasets, reconstructions with reduced orbital rotations (100\u00b0\u2013200\u00b0, in 20\u00b0 increments) were generated under three imaging conditions: (1) without a metal implant, (2) with plate osteosynthesis and extra-articular screw configuration, and (3) with plate osteosynthesis and intra-articular screw configuration. Both configurations were reconstructed with and without metal artifact reduction (MAR), resulting in 30 datasets per specimen. Three blinded raters independently assessed subjective image quality, visualization of the articular surface, intra-articular screw detection, and diagnostic certainty.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      A reduction of orbital rotation had a significant overall effect on subjective image quality and assessability of articular surfaces (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001). Post-hoc analysis showed no further significant improvement in image quality beyond 160\u00b0 of orbital rotation. MAR significantly enhanced image quality and surface visualization (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001). Sensitivity in detecting intra-articular screws was preserved down to an orbital rotation of 160\u00b0, while specificity was unaffected by rotation reduction (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.519). MAR did not significantly influence screw detection accuracy.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Intraoperative 3D imaging with a 160\u00b0 orbital rotation yields sufficient image quality, enabling the reliable identification of intra-articular screws during plate osteosynthesis of the proximal humerus. The additional use of MAR enhances visualization in the presence of metal without increasing the detection rate of misplaced screws. 3D imaging with reduced orbital rotation minimizes spatial demands and collision risks, supporting its practical application as an effective intraoperative imaging technique for the shoulder.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s13018-026-06800-9","type":"journal-article","created":{"date-parts":[[2026,4,5]],"date-time":"2026-04-05T12:54:01Z","timestamp":1775393641000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Effect of reduced orbital rotation on image quality and intra-articular screw detection in intraoperative 3D imaging of proximal humerus plate fixation: a cadaveric study"],"prefix":"10.1186","volume":"21","author":[{"given":"Benno","family":"Bullert","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Livia","family":"Morlock","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fenna","family":"Brunken","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paul A.","family":"Gruetzner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sven Y.","family":"Vetter","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nils","family":"Beisemann","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2026,4,5]]},"reference":[{"issue":"12","key":"6800_CR1","doi-asserted-by":"publisher","first-page":"2117","DOI":"10.1016\/j.jse.2017.05.029","volume":"26","author":"D Passaretti","year":"2017","unstructured":"Passaretti D, Candela V, Sessa P, Gumina S. Epidemiology of proximal humeral fractures: a detailed survey of 711 patients in a metropolitan area. J Shoulder Elb Surg. 2017;26(12):2117\u201324.","journal-title":"J Shoulder Elb Surg"},{"issue":"10","key":"6800_CR2","doi-asserted-by":"publisher","first-page":"1037","DOI":"10.1001\/jama.2015.1629","volume":"313","author":"A Rangan","year":"2015","unstructured":"Rangan A, Handoll H, Brealey S, et al. Surgical versus nonsurgical treatment of adults with displaced fractures of the proximal humerus: the PROFHER randomized clinical trial. JAMA. 2015;313(10):1037\u201347.","journal-title":"JAMA"},{"issue":"8","key":"6800_CR3","doi-asserted-by":"publisher","first-page":"691","DOI":"10.1016\/j.injury.2006.04.130","volume":"37","author":"CM Court-Brown","year":"2006","unstructured":"Court-Brown CM, Caesar B. Epidemiology of adult fractures: a review. Injury. 2006;37(8):691\u20137.","journal-title":"Injury"},{"issue":"8","key":"6800_CR4","doi-asserted-by":"publisher","first-page":"1697","DOI":"10.1007\/s00264-014-2362-6","volume":"38","author":"C Bahrs","year":"2014","unstructured":"Bahrs C, Stojicevic T, Blumenstock G, et al. Trends in epidemiology and patho-anatomical pattern of proximal humeral fractures. Int Orthop. 2014;38(8):1697\u2013704.","journal-title":"Int Orthop"},{"key":"6800_CR5","doi-asserted-by":"publisher","first-page":"750","DOI":"10.2340\/17453674.2022.4578","volume":"93","author":"S Brorson","year":"2022","unstructured":"Brorson S, Viberg B, Gundtoft P, Jalal B, Ohrt-Nissen S. Epidemiology and trends in management of acute proximal humeral fractures in adults: an observational study of 137,436 cases from the Danish National Patient Register, 1996\u20132018. Acta Orthop. 2022;93:750\u20135.","journal-title":"Acta Orthop"},{"issue":"3","key":"6800_CR6","doi-asserted-by":"publisher","first-page":"251","DOI":"10.2106\/JBJS.L.01293","volume":"96","author":"D Maier","year":"2014","unstructured":"Maier D, Jaeger M, Izadpanah K, Strohm PC, Suedkamp NP. Proximal humeral fracture treatment in adults. J bone joint Surg Am volume. 2014;96(3):251\u201361.","journal-title":"J bone joint Surg Am volume"},{"issue":"2","key":"6800_CR7","first-page":"311","volume":"12","author":"LM Oldrini","year":"2022","unstructured":"Oldrini LM, Feltri P, Albanese J, Marbach F, Filardo G, Candrian C. PHILOS synthesis for proximal humerus fractures has high complications and reintervention rates: a systematic review and meta-analysis. Life (Basel). 2022;12(2):311.","journal-title":"Life (Basel)"},{"issue":"8","key":"6800_CR8","doi-asserted-by":"publisher","first-page":"4993","DOI":"10.1007\/s00402-023-04820-2","volume":"143","author":"A B\u00f6hringer","year":"2023","unstructured":"B\u00f6hringer A, Cintean R, Eickhoff A, Gebhard F, Sch\u00fctze K. Intraoperative 3D imaging in plate osteosynthesis of proximal humerus fractures. Arch Orthop Trauma Surg. 2023;143(8):4993\u20135000.","journal-title":"Arch Orthop Trauma Surg"},{"issue":"5","key":"6800_CR9","first-page":"437","volume":"117","author":"P Hepp","year":"2014","unstructured":"Hepp P, Theopold J, Jarvers JS, Marquass B, von Dercks N, Josten C. [Multiplanar reconstruction with mobile 3D image intensifier. Surgical treatment of proximal humerus fractures]. Unfallchirurg. 2014;117(5):437\u201344.","journal-title":"Unfallchirurg"},{"issue":"8","key":"6800_CR10","doi-asserted-by":"publisher","first-page":"1150","DOI":"10.1016\/j.jse.2013.12.007","volume":"23","author":"YA Weil","year":"2014","unstructured":"Weil YA, Beyth S, Abu-Ahmad A, Khoury A, Liebergall M, Safran O. Use of three-dimensional fluoroscopy to determine intra-articular screw penetration in proximal humeral fracture model. J Shoulder Elb Surg. 2014;23(8):1150\u20135.","journal-title":"J Shoulder Elb Surg"},{"issue":"11","key":"6800_CR11","doi-asserted-by":"publisher","first-page":"1491","DOI":"10.1007\/s00402-017-2763-2","volume":"137","author":"J Theopold","year":"2017","unstructured":"Theopold J, Weihs K, Marqua\u00df B, Josten C, Hepp P. Detection of primary screw perforation in locking plate osteosynthesis of proximal humerus fracture by intra-operative 3D fluoroscopy. Arch Orthop Trauma Surg. 2017;137(11):1491\u20138.","journal-title":"Arch Orthop Trauma Surg"},{"key":"6800_CR12","doi-asserted-by":"crossref","unstructured":"Dobbins JT 3rd. Tomosynthesis imaging: at a translational crossroads. Med Phys. 2009;36(6):1956\u201367.","DOI":"10.1118\/1.3120285"},{"issue":"12","key":"6800_CR13","doi-asserted-by":"publisher","first-page":"4664","DOI":"10.1118\/1.2799492","volume":"34","author":"G Bachar","year":"2007","unstructured":"Bachar G, Siewerdsen J, Daly M, Jaffray D, Irish J. Image quality and localization accuracy in C-arm tomosynthesis\u2010guided head and neck surgery. Med Phys. 2007;34(12):4664\u201377.","journal-title":"Med Phys"},{"issue":"3","key":"6800_CR14","first-page":"821","volume":"66","author":"T Stubig","year":"2009","unstructured":"Stubig T, Kendoff D, Citak M, et al. Comparative study of different intraoperative 3-D image intensifiers in orthopedic trauma care. J Trauma. 2009;66(3):821\u201330.","journal-title":"J Trauma"},{"issue":"1","key":"6800_CR15","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1037\/0033-2909.112.1.155","volume":"112","author":"J Cohen","year":"1992","unstructured":"Cohen J. A power primer. Psychol Bull. 1992;112(1):155\u20139.","journal-title":"Psychol Bull"},{"issue":"4","key":"6800_CR16","doi-asserted-by":"publisher","first-page":"284","DOI":"10.1037\/1040-3590.6.4.284","volume":"6","author":"DV Cicchetti","year":"1994","unstructured":"Cicchetti DV. Guidelines, criteria, and rules of thumb for evaluating normed and standardized assessment instruments in psychology. Psychol Assess. 1994;6(4):284\u201390.","journal-title":"Psychol Assess"},{"issue":"10","key":"6800_CR17","doi-asserted-by":"publisher","first-page":"e401","DOI":"10.1097\/BOT.0000000000000333","volume":"29","author":"JB Lowe","year":"2015","unstructured":"Lowe JB, Monazzam S, Walton B, Nelson E, Wolinsky PR. How to use fluoroscopic imaging to prevent intraarticular screw perforation during locked plating of proximal humerus fractures: a cadaveric study. J Orthop Trauma. 2015;29(10):e401\u20137.","journal-title":"J Orthop Trauma"},{"issue":"10","key":"6800_CR18","doi-asserted-by":"publisher","first-page":"630","DOI":"10.1097\/BOT.0b013e318206eb65","volume":"25","author":"MJ Bengard","year":"2011","unstructured":"Bengard MJ, Gardner MJ. Screw depth sounding in proximal humerus fractures to avoid iatrogenic intra-articular penetration. J Orthop Trauma. 2011;25(10):630\u20133.","journal-title":"J Orthop Trauma"},{"issue":"Suppl 5","key":"6800_CR19","doi-asserted-by":"publisher","first-page":"S17","DOI":"10.1016\/j.injury.2020.10.049","volume":"52","author":"P Holweg","year":"2021","unstructured":"Holweg P, Dauwe J, Grechenig P, et al. Screw placement in two different implants for proximal humeral fractures regarding regional differences in bone mineral density: An anatomical study. Injury. 2021;52(Suppl 5):S17\u201321.","journal-title":"Injury"},{"issue":"1","key":"6800_CR20","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1007\/s00113-006-1202-6","volume":"110","author":"T Hufner","year":"2007","unstructured":"Hufner T, Stubig T, Gosling T, Kendoff D, Geerling J, Krettek C. Cost-benefit analysis of intraoperative 3D imaging. Unfallchirurg. 2007;110(1):14\u201321.","journal-title":"Unfallchirurg"},{"issue":"3","key":"6800_CR21","doi-asserted-by":"publisher","first-page":"328","DOI":"10.1016\/j.oooo.2020.03.049","volume":"130","author":"K de Faria Vasconcelos","year":"2020","unstructured":"de Faria Vasconcelos K, Queiroz PM, Codari M, et al. A quantitative analysis of metal artifact reduction algorithm performance in volume correction with 3 CBCT devices. Oral Surg Oral Med Oral Pathol Oral Radiol. 2020;130(3):328\u201335.","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13018-026-06800-9","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-026-06800-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-026-06800-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T11:14:08Z","timestamp":1777461248000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s13018-026-06800-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,5]]},"references-count":21,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["6800"],"URL":"https:\/\/doi.org\/10.1186\/s13018-026-06800-9","relation":{},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,5]]},"assertion":[{"value":"2 November 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 March 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 April 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was reviewed and approved by the responsible Ethics Committee (Rhineland-Palatinate Medical Association, Application No. 2024\u201317547; date: May 7, 2024). The legal and ethically correct handling of the human cadavers was reviewed by the ethics committee and confirmed by a positive vote. All procedures were in accordance with the ethical standards of the institutional and national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"The cadavers were obtained from Science Care (Science Care, Phoenix, AZ). Consent from the body donors for use in medical research was obtained during the donor\u2019s lifetime.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"283"}}