{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,25]],"date-time":"2026-05-25T05:03:00Z","timestamp":1779685380887,"version":"3.53.1"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,5,20]],"date-time":"2026-05-20T00:00:00Z","timestamp":1779235200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,5,25]],"date-time":"2026-05-25T00:00:00Z","timestamp":1779667200000},"content-version":"vor","delay-in-days":5,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Universit\u00e4tsklinikum Freiburg"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Displaced or unstable radial head fractures are commonly treated with fragment-preserving fixation to restore joint congruity, maintain stability, and allow early mobilization. Biodegradable implants have become attractive alternatives to metallic implants. However, polymer-based pins may be limited by inferior mechanical strength and a higher risk of secondary loss of reduction. Recently, zinc pins have emerged as a potential alternative, but clinical data and biomechanical testing in human bone models are scarce. This study aimed to compare the biomechanical performance of zinc pins (ZP) and polylactide pins (PP) for the fixation of Mason type II radial head fractures using a human cadaver model.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Sixteen human cadaver radii from eight donors were used to create standardized Mason type II radial head fractures. Paired left and right radii from each donor were randomly assigned to fixation with either two 2.0\u00a0mm ZP or PP. After fracture fixation, specimens underwent cyclic transverse loading (10 cycles), followed by cyclic axial loading (1,000 cycles) between 15 and 50 N at 0.1\u00a0Hz, and final load-to-failure testing with continuously increasing axial load (2 N\/s). Construct stiffness, micromotion at the fracture site, axial migration (implant loosening), as well as failure loads at 2\u00a0mm displacement and construct failure were recorded. A paired statistical analysis was performed to account for donor-specific variability.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Fixation with ZP demonstrated higher construct stiffness (0.77\u2009\u00b1\u20090.21 vs. 0.33\u2009\u00b1\u20090.05 kN\/mm; p-adj.\u2009=\u20090.028) compared to PP constructs under axial load. Further, lower micromotion at the fracture site (0.05\u2009\u00b1\u20090.01 vs. 0.10\u2009\u00b1\u20090.02\u00a0mm; p-adj.\u2009=\u20090.042) and higher resistance to progressive loading with higher loads at construct failure were measured in ZP compared to PP (190\u2009\u00b1\u200944 vs. 116\u2009\u00b1\u200962 N; p-adj.\u2009=\u20090.042). However, no differences were observed between groups in axial migration (0.36\u2009\u00b1\u20090.08\u00a0mm vs. 0.36\u2009\u00b1\u20090.08\u00a0mm) during cyclic testing, indicating comparable resistance to implant loosening. Notably, construct stiffness under transverse loading and the loads required to reach a clinically relevant fracture displacement of 2\u00a0mm (161\u2009\u00b1\u200937 vs. 112\u2009\u00b1\u200960 N; p-adj.\u2009=\u20090.116) did not differ between ZP and PP constructs, suggesting adequate stability of both constructs within functional loading ranges.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>In this cadaveric biomechanical study, zinc pins provided superior overall mechanical stability compared with polylactide pins for fixation of Mason type II radial head fractures, suggesting they are a promising alternative to the widely used polylactide pins. Importantly, polylactide pins also demonstrated sufficient primary stability without increased implant loosening or reduced resistance to clinically relevant fracture displacement. However, based on our data, zinc pins demonstrated favorable biomechanical performance in terms of construct stiffness and load to failure, offering a greater mechanical safety margin. Further clinical studies are required to evaluate in vivo performance and long-term outcomes of zinc-based biodegradable implants.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s13018-026-06964-4","type":"journal-article","created":{"date-parts":[[2026,5,20]],"date-time":"2026-05-20T14:56:28Z","timestamp":1779288988000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Biomechanical evaluation of biodegradable zinc and polylactide pins for radial head fracture fixation: a human cadaver study"],"prefix":"10.1186","volume":"21","author":[{"given":"Julian P.","family":"Maier","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Leon","family":"Pohl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonas","family":"Eck","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Benjamin","family":"Erdle","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nils","family":"M\u00fchlenfeld","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kilian","family":"Reising","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Seidenstuecker","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hagen","family":"Schmal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ferdinand C.","family":"Wagner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,5,20]]},"reference":[{"key":"6964_CR1","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1016\/j.jhsa.2020.05.029","volume":"46","author":"A Klug","year":"2021","unstructured":"Klug A, Gramlich Y, Wincheringer D, Hoffmann R, Schmidt-Horloh\u00e9 K. Epidemiology and treatment of radial head fractures: a database analysis of over 70,000 inpatient cases. J Hand Surg Am. 2021;46:27\u201335.","journal-title":"J Hand Surg Am"},{"key":"6964_CR2","doi-asserted-by":"publisher","first-page":"677","DOI":"10.1016\/S0268-0033(03)00115-3","volume":"18","author":"DM Beingessner","year":"2003","unstructured":"Beingessner DM, Dunning CE, Beingessner CJ, Johnson JA, King GJW. The effect of radial head fracture size on radiocapitellar joint stability. Clin Biomech (Bristol, Avon). 2003;18:677\u201381.","journal-title":"Clin Biomech (Bristol, Avon)"},{"issue":"1 Suppl S","key":"6964_CR3","doi-asserted-by":"publisher","first-page":"174S","DOI":"10.1016\/j.jse.2004.09.031","volume":"14","author":"BF Morrey","year":"2005","unstructured":"Morrey BF, An K-N. Stability of the elbow: osseous constraints. J Shoulder Elbow Surg. 2005;14(1 Suppl S):174S-178S.","journal-title":"J Shoulder Elbow Surg"},{"key":"6964_CR4","doi-asserted-by":"publisher","first-page":"315","DOI":"10.1177\/036354658301100506","volume":"11","author":"BF Morrey","year":"1983","unstructured":"Morrey BF, An KN. Articular and ligamentous contributions to the stability of the elbow joint. Am J Sports Med. 1983;11:315\u20139.","journal-title":"Am J Sports Med"},{"key":"6964_CR5","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1016\/j.jse.2004.07.001","volume":"14","author":"P Herbertsson","year":"2005","unstructured":"Herbertsson P, Josefsson PO, Hasserius R, Karlsson C, Besjakov J, Karlsson MK. Displaced Mason type I fractures of the radial head and neck in adults: a fifteen- to thirty-three-year follow-up study. J Shoulder Elbow Surg. 2005;14:73\u20137.","journal-title":"J Shoulder Elbow Surg"},{"key":"6964_CR6","first-page":"643","volume":"71","author":"AD Duckworth","year":"2011","unstructured":"Duckworth AD, Watson BS, Will EM, Petrisor BA, Walmsley PJ, Court-Brown CM, et al. Radial head and neck fractures: functional results and predictors of outcome. J Trauma. 2011;71:643\u20138.","journal-title":"J Trauma"},{"key":"6964_CR7","first-page":"1909","volume":"88","author":"T Akesson","year":"2006","unstructured":"Akesson T, Herbertsson P, Josefsson P-O, Hasserius R, Besjakov J, Karlsson MK. Primary nonoperative treatment of moderately displaced two-part fractures of the radial head. J Bone Joint Surg Am. 2006;88:1909\u201314.","journal-title":"J Bone Joint Surg Am"},{"key":"6964_CR8","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1007\/s00113-018-0504-9","volume":"122","author":"A von Glinski","year":"2019","unstructured":"von Glinski A, Rausch V, K\u00f6nigshausen M, Dudda M, Schildhauer TA, Seybold D, et al. Instability after operative and conservative treatment of isolated Mason type II fractures. Unfallchirurg. 2019;122:219\u201324.","journal-title":"Unfallchirurg"},{"key":"6964_CR9","doi-asserted-by":"publisher","first-page":"112","DOI":"10.1007\/s11678-018-0456-2","volume":"13","author":"R Nietschke","year":"2018","unstructured":"Nietschke R, Burkhart KJ, Hollinger B, Dehlinger FI, Zimmerer A, Schneider MM. Reasons for surgical revision after conservatively treated radial head fractures-retrospective study of 70 patients. Obere Extrem. 2018;13:112\u201320.","journal-title":"Obere Extrem"},{"key":"6964_CR10","doi-asserted-by":"publisher","first-page":"1540","DOI":"10.1016\/j.injury.2013.04.003","volume":"44","author":"J Zwingmann","year":"2013","unstructured":"Zwingmann J, Welzel M, Dovi-Akue D, Schmal H, S\u00fcdkamp NP, Strohm PC. Clinical results after different operative treatment methods of radial head and neck fractures: a systematic review and meta-analysis of clinical outcome. Injury. 2013;44:1540\u201350.","journal-title":"Injury"},{"key":"6964_CR11","volume":"16","author":"M Mannan","year":"2024","unstructured":"Mannan M, Hamid MA, Shrivastava N, Akbar R, Sarwar AR. Functional outcomes of radial head fractures treated with open reduction and internal fixation (ORIF). Cureus. 2024;16:e74801.","journal-title":"Cureus"},{"key":"6964_CR12","doi-asserted-by":"publisher","first-page":"233","DOI":"10.13107\/jocr.2025.v15.i03.5398","volume":"15","author":"V Nair","year":"2025","unstructured":"Nair V, Patil V, Kaneria S, Kumar H, Todkar A, Shah M. Functional outcome of radial head fracture treated with open reduction internal fixation using plating versus Herbert screw fixation: a case series. J Orthop Case Reports. 2025;15:233\u20138.","journal-title":"J Orthop Case Reports"},{"key":"6964_CR13","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1016\/j.jse.2024.07.016","volume":"34","author":"A Afifi","year":"2025","unstructured":"Afifi A, Othman M, Moharram AN, Abdel-Ati EA. Miniplates vs. headless screws for fixation of displaced radial head fractures: a randomized controlled trial. J Shoulder Elbow Surg. 2025;34:10\u20137.","journal-title":"J Shoulder Elbow Surg"},{"key":"6964_CR14","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1177\/0954411919884794","volume":"234","author":"FC Wagner","year":"2020","unstructured":"Wagner FC, Feucht MJ, Konstantinidis L, Hohloch L, Yilmaz T, Bernstein A, et al. Biomechanical dynamic comparison of biodegradable pins and titanium screws for operative stabilization of displaced radial head fractures. Proc Inst Mech Eng H. 2020;234:74\u201380.","journal-title":"Proc Inst Mech Eng H"},{"key":"6964_CR15","doi-asserted-by":"publisher","first-page":"1013","DOI":"10.4055\/cios23074","volume":"15","author":"C-H Lee","year":"2023","unstructured":"Lee C-H, Woo S, Choi HD. Results of the use of bioabsorbable magnesium screws for surgical treatment of Mason type II radial head fractures. Clin Orthop Surg. 2023;15:1013\u201321.","journal-title":"Clin Orthop Surg"},{"key":"6964_CR16","doi-asserted-by":"publisher","first-page":"479","DOI":"10.1016\/j.jse.2005.10.010","volume":"15","author":"H-J Helling","year":"2006","unstructured":"Helling H-J, Prokop A, Schmid HU, Nagel M, Lilienthal J, Rehm KE. Biodegradable implants versus standard metal fixation for displaced radial head fractures. A prospective, randomized, multicenter study. J Shoulder Elbow Surg. 2006;15:479\u201385.","journal-title":"J Shoulder Elbow Surg"},{"key":"6964_CR17","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1055\/s-0033-1351079","volume":"151","author":"A Prokop","year":"2013","unstructured":"Prokop A, Chmielnicki M. [Management of dislocated radial head fractures with biodegradable implants]. Z Orthop Unfall. 2013;151:565\u20138.","journal-title":"Z Orthop Unfall"},{"key":"6964_CR18","doi-asserted-by":"publisher","first-page":"997","DOI":"10.1007\/s00104-002-0545-y","volume":"73","author":"A Prokop","year":"2002","unstructured":"Prokop A, Jubel A, Helling HJ, Udomkaewkanjana C, Brochhagen HG, Rehm KE. [New biodegradable polylactide implants (Polypin-C) in therapy for radial head fractures]. Chirurg. 2002;73:997\u20131004.","journal-title":"Chirurg"},{"key":"6964_CR19","doi-asserted-by":"publisher","first-page":"94","DOI":"10.1186\/s12891-018-2014-x","volume":"19","author":"L Tarallo","year":"2018","unstructured":"Tarallo L, Mugnai R, Rocchi M, Capra F, Catani F. Comparison between absorbable pins and mini-screw fixations for the treatment of radial head fractures Mason type II-III. BMC Musculoskelet Disord. 2018;19:94.","journal-title":"BMC Musculoskelet Disord"},{"key":"6964_CR20","doi-asserted-by":"publisher","first-page":"365","DOI":"10.1016\/j.jse.2020.06.007","volume":"30","author":"FC Wagner","year":"2021","unstructured":"Wagner FC, Polossek L, Yilmaz T, Jaeger M, Maier D, Feucht MJ, et al. Biodegradable magnesium vs. polylactide pins for radial head fracture stabilization: a biomechanical study. J Shoulder Elbow Surg. 2021;30:365\u201372.","journal-title":"J Shoulder Elbow Surg"},{"key":"6964_CR21","doi-asserted-by":"publisher","DOI":"10.3390\/ma16155224","volume":"16","author":"M Roesner","year":"2023","unstructured":"Roesner M, Zankovic S, Kovacs A, Benner M, Barkhoff R, Seidenstuecker M. Biocompatibility assessment of zinc alloys as a new potential material for bioabsorbable implants for osteosynthesis. Materials. 2023;16:16.","journal-title":"Materials"},{"key":"6964_CR22","doi-asserted-by":"publisher","DOI":"10.3390\/jfb15020028","volume":"15","author":"M Roesner","year":"2024","unstructured":"Roesner M, Zankovic S, Kovacs A, Benner M, Barkhoff R, Seidenstuecker M. Mechanical properties and corrosion rate of znag3 as a novel bioabsorbable material for osteosynthesis. J Funct Biomat. 2024;15:15.","journal-title":"J Funct Biomat"},{"key":"6964_CR23","doi-asserted-by":"publisher","DOI":"10.3390\/ma15020421","volume":"15","author":"S Hagelstein","year":"2022","unstructured":"Hagelstein S, Zankovic S, Kovacs A, Barkhoff R, Seidenstuecker M. Mechanical analysis and corrosion analysis of zinc alloys for bioabsorbable implants for osteosynthesis. Materials. 2022;15:15.","journal-title":"Materials"},{"key":"6964_CR24","first-page":"4607","volume":"6","author":"X Qu","year":"2021","unstructured":"Qu X, Yang H, Jia B, Wang M, Yue B, Zheng Y, et al. Zinc alloy-based bone internal fixation screw with antibacterial and anti-osteolytic properties. Bioact Mater. 2021;6:4607\u201324.","journal-title":"Bioact Mater"},{"key":"6964_CR25","doi-asserted-by":"publisher","first-page":"870","DOI":"10.1186\/s13018-025-06346-2","volume":"20","author":"JP Maier","year":"2025","unstructured":"Maier JP, Eck J, Erdle B, M\u00fchlenfeld N, Seidenstuecker M, Reising K, et al. Biomechanical analysis of biodegradable magnesium, zinc, and polylactide pins for fixation of radial head fractures. J Orthop Surg Res. 2025;20:870.","journal-title":"J Orthop Surg Res"},{"key":"6964_CR26","doi-asserted-by":"publisher","first-page":"6809","DOI":"10.1021\/acsami.8b20634","volume":"11","author":"D Zhu","year":"2019","unstructured":"Zhu D, Cockerill I, Su Y, Zhang Z, Fu J, Lee K-W, et al. Mechanical strength, biodegradation, and in vitro and in vivo biocompatibility of Zn biomaterials. ACS Appl Mater Interfaces. 2019;11:6809\u201319.","journal-title":"ACS Appl Mater Interfaces"},{"key":"6964_CR27","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1002\/ca.70007","volume":"39","author":"J Iwanaga","year":"2026","unstructured":"Iwanaga J, Obata K, Kato T, Samrid R, Lesser ER, Cardona JJ, et al. What is the appropriate sample size in human cadaveric studies? A quantitative review of 770 articles. Clin Anat. 2026;39:14\u20139.","journal-title":"Clin Anat"},{"key":"6964_CR28","doi-asserted-by":"publisher","first-page":"2253","DOI":"10.1016\/j.injury.2020.07.041","volume":"51","author":"L Guo","year":"2020","unstructured":"Guo L, Li R, Yang X, Yu C, Gui F. Polylactide pins can effectively fix severely comminuted and unsalvageable radial head fracture: a retrospective study of 40 patients. Injury. 2020;51:2253\u20138.","journal-title":"Injury"},{"key":"6964_CR29","doi-asserted-by":"publisher","first-page":"258","DOI":"10.1007\/BF00419939","volume":"109","author":"E Hirvensalo","year":"1990","unstructured":"Hirvensalo E, B\u00f6stman O, Rokkanen P. Absorbable polyglycolide pins in fixation of displaced fractures of the radial head. Arch Orthop Trauma Surg. 1990;109:258\u201361.","journal-title":"Arch Orthop Trauma Surg"},{"key":"6964_CR30","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-024-70602-4","volume":"14","author":"L Yang","year":"2024","unstructured":"Yang L, Zhang X, Zhong Z, Li J, Xiong Z. Patient-specific finite element analysis of four different fixation methods for transversely unstable radial head fractures. Sci Rep. 2024;14:21134.","journal-title":"Sci Rep"},{"key":"6964_CR31","doi-asserted-by":"publisher","first-page":"212","DOI":"10.1177\/1758573219876921","volume":"12","author":"RP van Riet","year":"2020","unstructured":"van Riet RP, van den Bekerom M, Van Tongel A, Spross C, Barco R, Watts AC. Radial head fractures. Shoulder Elbow. 2020;12:212\u201323.","journal-title":"Shoulder Elbow"},{"key":"6964_CR32","doi-asserted-by":"publisher","first-page":"469","DOI":"10.2106\/JBJS.J.01989","volume":"95","author":"DE Ruchelsman","year":"2013","unstructured":"Ruchelsman DE, Christoforou D, Jupiter JB. Fractures of the radial head and neck. J Bone Joint Surg Am. 2013;95:469\u201378.","journal-title":"J Bone Joint Surg Am"},{"key":"6964_CR33","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiomech.2025.106557","volume":"126","author":"JF Teilmann","year":"2025","unstructured":"Teilmann JF, Kipp JO, Petersen ET, Hemmingsen CK, Stilling M, Thillemann TM. Type II coronoid fracture in a terrible triad elbow: An experimental study of the elbow kinematics using dynamic radiostereometric analysis. Clin Biomech (Bristol, Avon). 2025;126:106557.","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"6964_CR34","doi-asserted-by":"publisher","first-page":"e906","DOI":"10.1016\/j.jse.2025.01.032","volume":"34","author":"JP Hockmann","year":"2025","unstructured":"Hockmann JP, Heck V, Thei\u00dfen N, Prescher A, Leschinger T, M\u00fcller LP, et al. Bone graft augmentation of comminuted radial neck fractures improves the initial stability of plate fixation. A biomechanical study. J Shoulder Elbow Surg. 2025;34:e906\u201312.","journal-title":"J Shoulder Elbow Surg"},{"key":"6964_CR35","doi-asserted-by":"publisher","first-page":"600","DOI":"10.2106\/JBJS.23.00417","volume":"106","author":"T France","year":"2024","unstructured":"France T, Lockwood W, Gu S, Tucker N, Baldini T, Lauder A, et al. Radiocapitellar and ulnotrochlear pressures increase in a radial head fracture model: A cadaveric biomechanical analysis. J Bone Joint Surg Am. 2024;106:600\u20137.","journal-title":"J Bone Joint Surg Am"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13018-026-06964-4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-026-06964-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-026-06964-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,25]],"date-time":"2026-05-25T04:20:48Z","timestamp":1779682848000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s13018-026-06964-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,20]]},"references-count":35,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["6964"],"URL":"https:\/\/doi.org\/10.1186\/s13018-026-06964-4","relation":{},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,20]]},"assertion":[{"value":"30 January 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 May 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 May 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The local ethics committee of the University of Freiburg approved the experimental design (protocol 25-1014-S1), and all methods were carried out in accordance with the approved guidelines. Human cadaveric specimens were obtained from Science Care (Phoenix, AZ, USA) with informed consent for research and educational use. This study was conducted in accordance with the ethical principles of the Declaration of Helsinki.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"315"}}