{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T17:01:44Z","timestamp":1786122104375,"version":"build-2736575974"},"reference-count":37,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T00:00:00Z","timestamp":1780444800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T00:00:00Z","timestamp":1786060800000},"content-version":"vor","delay-in-days":65,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"DOI":"10.13039\/501100019331","name":"Henan Medical Science and Technique Foundation","doi-asserted-by":"publisher","award":["LHGJ20230937"],"award-info":[{"award-number":["LHGJ20230937"]}],"id":[{"id":"10.13039\/501100019331","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"DOI":"10.1186\/s13018-026-06988-w","type":"journal-article","created":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T14:49:16Z","timestamp":1780498156000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Self-stabilizing zero-profile 3D-printed vertebral body versus traditional titanium mesh-cage with plate in anterior cervical corpectomy and fusion: an open-label randomized controlled trial on efficacy and complications for cervical spondylotic myelopathy"],"prefix":"10.1186","volume":"21","author":[{"given":"Yuwei","family":"Li","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiuzhi","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Citing","family":"Guo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei","family":"Cui","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shifeng","family":"Gu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Haijiao","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,6,3]]},"reference":[{"key":"6988_CR1","doi-asserted-by":"publisher","first-page":"E675","DOI":"10.1097\/BRS.0000000000000913","volume":"40","author":"A Nouri","year":"2015","unstructured":"Nouri A, Tetreault L, Singh A, Karadimas SK, Fehlings MG. Degenerative cervical myelopathy: epidemiology, genetics, and pathogenesis. Spine (Phila Pa 1976). 2015;40:E675\u2013693. https:\/\/doi.org\/10.1097\/BRS.0000000000000913.","journal-title":"Spine (Phila Pa 1976)"},{"key":"6988_CR2","doi-asserted-by":"publisher","first-page":"303","DOI":"10.3122\/jabfm.2020.02.190195","volume":"33","author":"JR McCormick","year":"2020","unstructured":"McCormick JR, Sama AJ, Schiller NC, Butler AJ, Donnally CJ. Cervical spondylotic myelopathy: a guide to diagnosis and management. J Am Board Fam Med. 2020;33:303\u201313. https:\/\/doi.org\/10.3122\/jabfm.2020.02.190195.","journal-title":"J Am Board Fam Med"},{"key":"6988_CR3","doi-asserted-by":"publisher","first-page":"7139","DOI":"10.3390\/jcm13237139","volume":"13","author":"M Balmaceno-Criss","year":"2024","unstructured":"Balmaceno-Criss M, Singh M, Daher M, Buchbinder R, Diebo BG, Daniels AH. Degenerative cervical myelopathy: history, physical examination, and diagnosis. J Clin Med. 2024;13:7139. https:\/\/doi.org\/10.3390\/jcm13237139.","journal-title":"J Clin Med"},{"key":"6988_CR4","doi-asserted-by":"publisher","first-page":"1839","DOI":"10.1177\/21925682241297586","volume":"15","author":"L Chen","year":"2025","unstructured":"Chen L, Zhang Z, Li J, Tong P, Xu T. Meta-analysis of treatment for adjacent two-segment cervical spondylotic myelopathy: a comparison between anterior cervical corpectomy and fusion and anterior cervical discectomy and fusion. Global Spine J. 2025;15:1839\u201348. https:\/\/doi.org\/10.1177\/21925682241297586.","journal-title":"Global Spine J"},{"key":"6988_CR5","doi-asserted-by":"publisher","unstructured":"Verma A, Kumar A, Anand U, Sethy SS, Jain A, Abrol V, et al. Anterior cervical discectomy and fusion vs. anterior cervical corpectomy and fusion for 2-level degenerative cervical myelopathy: a systematic review and meta-analysis. JBJS Rev. 2025;13. https:\/\/doi.org\/10.2106\/JBJS.RVW.24.00204.","DOI":"10.2106\/JBJS.RVW.24.00204"},{"key":"6988_CR6","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1016\/j.aott.2017.12.003","volume":"52","author":"C Doria","year":"2018","unstructured":"Doria C, Mosele GR, Balsano M, Maestretti G, Caggiari G. Anterior decompression and plate fixation in treatment of cervical myelopathy: a multicentric retrospective review. Acta Orthop Traumatol Turc. 2018;52:185\u201390. https:\/\/doi.org\/10.1016\/j.aott.2017.12.003.","journal-title":"Acta Orthop Traumatol Turc"},{"key":"6988_CR7","doi-asserted-by":"publisher","first-page":"E4","DOI":"10.3171\/foc.2003.15.3.4","volume":"15","author":"I Thongtrangan","year":"2003","unstructured":"Thongtrangan I, Balabhadra RSV, Kim DH. Management of strut graft failure in anterior cervical spine surgery. Neurosurg Focus. 2003;15:E4. https:\/\/doi.org\/10.3171\/foc.2003.15.3.4.","journal-title":"Neurosurg Focus"},{"key":"6988_CR8","first-page":"607","volume":"47","author":"X Ma","year":"2009","unstructured":"Ma X, Zhao X, Zhao Y. A clinical study on different decompression methods in cervical spondylosis. Zhonghua Wai Ke Za Zhi. 2009;47:607\u20139.","journal-title":"Zhonghua Wai Ke Za Zhi"},{"key":"6988_CR9","doi-asserted-by":"publisher","first-page":"1077551","DOI":"10.3389\/fsurg.2022.1077551","volume":"9","author":"H Cheng","year":"2022","unstructured":"Cheng H, Luo G, Xu D, Li Y, Wang Z, Yang H, et al. Comparison of radiological and clinical outcomes of 3D-printed artificial vertebral body with Titanium mesh cage in single-level anterior cervical corpectomy and fusion: a meta-analysis. Front Surg. 2022;9:1077551. https:\/\/doi.org\/10.3389\/fsurg.2022.1077551.","journal-title":"Front Surg"},{"key":"6988_CR10","doi-asserted-by":"publisher","first-page":"515","DOI":"10.1186\/s13018-022-03409-6","volume":"17","author":"Y Tang","year":"2022","unstructured":"Tang Y, Geng X, Li F, Sun Y, Jia L, Zhou S, et al. Factors affecting titanium mesh cage subsidence in single-level anterior cervical corpectomy and fusion for ossification of the posterior longitudinal ligament. J Orthop Surg Res. 2022;17:515. https:\/\/doi.org\/10.1186\/s13018-022-03409-6.","journal-title":"J Orthop Surg Res"},{"key":"6988_CR11","doi-asserted-by":"publisher","first-page":"1327319","DOI":"10.3389\/fonc.2024.1327319","volume":"14","author":"M Dong","year":"2024","unstructured":"Dong M, Gao Y, Fan H, Wang Y, Lv J, Bai J, et al. Comparison of clinical efficacy of 3D-printed artificial vertebral body and conventional titanium mesh cage in spinal reconstruction after total en bloc spondylectomy for spinal tumors: a systematic review and meta-analysis. Front Oncol. 2024;14:1327319. https:\/\/doi.org\/10.3389\/fonc.2024.1327319.","journal-title":"Front Oncol"},{"key":"6988_CR12","doi-asserted-by":"publisher","first-page":"1024","DOI":"10.3390\/jpm14101024","volume":"14","author":"R Kiselev","year":"2024","unstructured":"Kiselev R, Zheravin A. Clinical application of 3D-Printed artificial vertebral body (3DP AVB): a review. J Pers Med. 2024;14:1024. https:\/\/doi.org\/10.3390\/jpm14101024.","journal-title":"J Pers Med"},{"key":"6988_CR13","doi-asserted-by":"publisher","first-page":"88","DOI":"10.1097\/BRS.0000000000005126","volume":"50","author":"J Li","year":"2025","unstructured":"Li J, Zhang J, Wang B, Huang K, Yang X, Song Y, et al. Comparison of titanium mesh cage, nano-hydroxyapatite\/polyamide cage, and three-dimensional-printed vertebral body for anterior cervical corpectomy and fusion. Spine (Phila Pa 1976). 2025;50:88\u201395. https:\/\/doi.org\/10.1097\/BRS.0000000000005126.","journal-title":"Spine (Phila Pa 1976)"},{"key":"6988_CR14","doi-asserted-by":"publisher","first-page":"1248","DOI":"10.1007\/s00586-019-06236-2","volume":"29","author":"JL Burnard","year":"2020","unstructured":"Burnard JL, Parr WCH, Choy WJ, Walsh WR, Mobbs RJ. 3D-printed spine surgery implants: a systematic review of the efficacy and clinical safety profile of patient-specific and off-the-shelf devices. Eur Spine J. 2020;29:1248\u201360. https:\/\/doi.org\/10.1007\/s00586-019-06236-2.","journal-title":"Eur Spine J"},{"key":"6988_CR15","doi-asserted-by":"publisher","first-page":"833","DOI":"10.1016\/j.spinee.2019.11.004","volume":"20","author":"Y Tong","year":"2020","unstructured":"Tong Y, Kaplan DJ, Spivak JM, Bendo JA. Three-dimensional printing in spine surgery: a review of current applications. Spine J. 2020;20:833\u201346. https:\/\/doi.org\/10.1016\/j.spinee.2019.11.004.","journal-title":"Spine J"},{"key":"6988_CR16","doi-asserted-by":"publisher","first-page":"404","DOI":"10.1186\/s12891-025-08625-9","volume":"26","author":"K-R Zhang","year":"2025","unstructured":"Zhang K-R, Yang Y, Li Y-Q, Ma L-T, Wang B-Y, Ding C, et al. Effects of new assembled titanium mesh cage on the improvement in biomechanical performance of single-level anterior cervical corpectomy and fusion: a finite element analysis. BMC Musculoskelet Disord. 2025;26:404. https:\/\/doi.org\/10.1186\/s12891-025-08625-9.","journal-title":"BMC Musculoskelet Disord"},{"key":"6988_CR17","doi-asserted-by":"publisher","first-page":"975","DOI":"10.1007\/s00586-016-4914-5","volume":"26","author":"S Xiao","year":"2017","unstructured":"Xiao S, Liang Z, Wei W, Ning J. Zero-profile anchored cage reduces risk of postoperative dysphagia compared with cage with plate fixation after anterior cervical discectomy and fusion. Eur Spine J. 2017;26:975\u201384. https:\/\/doi.org\/10.1007\/s00586-016-4914-5.","journal-title":"Eur Spine J"},{"key":"6988_CR18","doi-asserted-by":"publisher","first-page":"1025","DOI":"10.1007\/s00455-022-10535-0","volume":"38","author":"J McRae","year":"2023","unstructured":"McRae J, Morgan S, Wallace E, Miles A. Oropharyngeal dysphagia in acute cervical spinal cord injury: a literature review. Dysphagia. 2023;38:1025\u201338. https:\/\/doi.org\/10.1007\/s00455-022-10535-0.","journal-title":"Dysphagia"},{"key":"6988_CR19","doi-asserted-by":"publisher","first-page":"3534","DOI":"10.1038\/s41598-025-88151-9","volume":"15","author":"S Ni","year":"2025","unstructured":"Ni S, Yang R, Liu S, Hu Y. Biomechanical analysis of a newly designed and 3D printed plate-locking interbody cage: an observational study of finite element analysis. Sci Rep. 2025;15:3534. https:\/\/doi.org\/10.1038\/s41598-025-88151-9.","journal-title":"Sci Rep"},{"key":"6988_CR20","doi-asserted-by":"publisher","first-page":"1059","DOI":"10.1186\/s13018-025-06351-5","volume":"20","author":"H Lv","year":"2025","unstructured":"Lv H, Xu M, Ai Q, Wang F, Zhang Z, Hou T. 3D-printed tantalum artificial vertebral body or titanium mesh in anterior column reconstruction post-spondylectomy for thoracic vertebral tumors: a retrospective comparative cohort study and finite element analysis. J Orthop Surg Res. 2025;20:1059. https:\/\/doi.org\/10.1186\/s13018-025-06351-5.","journal-title":"J Orthop Surg Res"},{"key":"6988_CR21","doi-asserted-by":"publisher","first-page":"526","DOI":"10.3760\/cma.j.cn112137-20230801-00128","volume":"104","author":"YW Li","year":"2024","unstructured":"Li YW, Li XZ, Gu SF, Xu JY, Cui W, Wang HJ. Clinical observation on the treatment of ossification of the posterior longitudinal ligament of the cervical spine using 3D printed self-stable zero-profile artificial vertebral body. Zhonghua Yi Xue Za Zhi. 2024;104:526\u201332. https:\/\/doi.org\/10.3760\/cma.j.cn112137-20230801-00128.","journal-title":"Zhonghua Yi Xue Za Zhi"},{"key":"6988_CR22","doi-asserted-by":"publisher","first-page":"2","DOI":"10.70389\/PJS.100082","volume-title":"Transparency in the Reporting of Artificial Intelligence \u2013 The TITAN Guideline. Premier Journal of Science [Internet]","author":"AA Riaz","year":"2025","unstructured":"Riaz AA, Ginimol M, Rasha R, Ahmed K, Ahmed A, Catrin S, et al. Transparency in the reporting of artificial intelligence \u2013 the TITAN guideline. Premier J Sci. 2025. p. 2. https:\/\/doi.org\/10.70389\/PJS.100082."},{"key":"6988_CR23","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(25)00672-5","author":"S Hopewell","year":"2025","unstructured":"Hopewell S, Chan A-W, Collins GS, Hr\u00f3bjartsson A, Moher D, Schulz KF, et al. CONSORT 2025 statement: updated guideline for reporting randomised trials. Lancet. 2025. https:\/\/doi.org\/10.1016\/S0140-6736(25)00672-5. S0140-6736(25)00672-5.","journal-title":"Lancet"},{"key":"6988_CR24","doi-asserted-by":"publisher","first-page":"2450","DOI":"10.1177\/21925682241303107","volume":"15","author":"CT Martin","year":"2025","unstructured":"Martin CT, Yoon ST, Alluri RK, Benzel EC, Bono CM, Cho SK, et al. How reliable is the assessment of fusion status following ACDF using dynamic flexion-extension radiographs? Global Spine J. 2025;15:2450\u20137. https:\/\/doi.org\/10.1177\/21925682241303107.","journal-title":"Global Spine J"},{"key":"6988_CR25","doi-asserted-by":"publisher","first-page":"919","DOI":"10.1177\/000348940811701210","volume":"117","author":"PC Belafsky","year":"2008","unstructured":"Belafsky PC, Mouadeb DA, Rees CJ, Pryor JC, Postma GN, Allen J, et al. Validity and reliability of the eating assessment tool (EAT-10). Ann Otol Rhinol Laryngol. 2008;117:919\u201324. https:\/\/doi.org\/10.1177\/000348940811701210.","journal-title":"Ann Otol Rhinol Laryngol"},{"key":"6988_CR26","doi-asserted-by":"publisher","unstructured":"Alentado VJ, Bisson EF, Potts EA. Dysphagia after cervical spine surgery: a review of risk factors and preventative measures. 2022 [cited 2025 Aug 27]; https:\/\/doi.org\/10.3171\/2022.11.SPINE221247","DOI":"10.3171\/2022.11.SPINE221247"},{"key":"6988_CR27","doi-asserted-by":"publisher","first-page":"455","DOI":"10.1007\/s004150050122","volume":"244","author":"H Baba","year":"1997","unstructured":"Baba H, Maezawa Y, Uchida K, Furusawa N, Wada M, Imura S. Plasticity of the spinal cord contributes to neurological improvement after treatment by cervical decompression. A magnetic resonance imaging study. J Neurol. 1997;244:455\u201360. https:\/\/doi.org\/10.1007\/s004150050122.","journal-title":"J Neurol"},{"key":"6988_CR28","first-page":"409","volume":"14","author":"H Vernon","year":"1991","unstructured":"Vernon H, Mior S. The Neck Disability Index: a study of reliability and validity. J Manip Physiol Ther. 1991;14:409\u201315.","journal-title":"J Manipulative Physiol Ther"},{"key":"6988_CR29","doi-asserted-by":"publisher","first-page":"415","DOI":"10.1007\/BF00562315","volume":"8","author":"CR Joyce","year":"1975","unstructured":"Joyce CR, Zutshi DW, Hrubes V, Mason RM. Comparison of fixed interval and visual analogue scales for rating chronic pain. Eur J Clin Pharmacol. 1975;8:415\u201320. https:\/\/doi.org\/10.1007\/BF00562315.","journal-title":"Eur J Clin Pharmacol"},{"key":"6988_CR30","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1016\/j.jot.2025.04.010","volume":"53","author":"T Zhang","year":"2025","unstructured":"Zhang T, Li J, Li X, Pan X, Gao X, Yang X, et al. An innovative self-stabilised 3D-printed artificial vertebral body designed for clinical application and comparison with the conventional implants. J Orthop Translation. 2025;53:52\u201362. https:\/\/doi.org\/10.1016\/j.jot.2025.04.010.","journal-title":"J Orthop Translation"},{"key":"6988_CR31","doi-asserted-by":"publisher","first-page":"161","DOI":"10.19723\/j.issn.1671-167X.2024.01.025","volume":"56","author":"P Hu","year":"2024","unstructured":"Hu P, Li Y, Liu X, Tang Y, Li Z, Liu Z. Clinical outcomes of 3D-printing stand-alone artificial vertebral body in anterior cervical surgeries. Beijing Da Xue Xue Bao Yi Xue Ban. 2024;56:161\u20136. https:\/\/doi.org\/10.19723\/j.issn.1671-167X.2024.01.025.","journal-title":"Beijing Da Xue Xue Bao Yi Xue Ban"},{"key":"6988_CR32","doi-asserted-by":"publisher","first-page":"1060","DOI":"10.1186\/s12891-025-09308-1","volume":"26","author":"H Wang","year":"2025","unstructured":"Wang H, Qu R, Xia T, Geng H, Yi Z, Sun Y, et al. Artificial vertebral body versus titanium mesh cage for single-level anterior cervical corpectomy and fusion (ACCF): a propensity score matching analysis of fusion, implant subsidence and clinical outcomes. BMC Musculoskelet Disord. 2025;26:1060. https:\/\/doi.org\/10.1186\/s12891-025-09308-1.","journal-title":"BMC Musculoskelet Disord"},{"key":"6988_CR33","doi-asserted-by":"publisher","first-page":"96","DOI":"10.1186\/s12891-024-07213-7","volume":"25","author":"H He","year":"2024","unstructured":"He H, Fan L, L\u00fc G, Li X, Li Y, Zhang O, et al. Myth or fact: 3D-printed off-the-shelf prosthesis is superior to titanium mesh cage in anterior cervical corpectomy and fusion? BMC Musculoskelet Disord. 2024;25:96. https:\/\/doi.org\/10.1186\/s12891-024-07213-7.","journal-title":"BMC Musculoskelet Disord"},{"key":"6988_CR34","doi-asserted-by":"publisher","first-page":"2891","DOI":"10.1007\/s00586-013-2976-1","volume":"22","author":"Y Fengbin","year":"2013","unstructured":"Fengbin Y, Jinhao M, Xinyuan L, Xinwei W, Yu C, Deyu C. Evaluation of a new type of titanium mesh cage versus the traditional titanium mesh cage for single-level, anterior cervical corpectomy and fusion. Eur Spine J. 2013;22:2891\u20136. https:\/\/doi.org\/10.1007\/s00586-013-2976-1.","journal-title":"Eur Spine J"},{"key":"6988_CR35","doi-asserted-by":"publisher","first-page":"e928022","DOI":"10.12659\/MSM.928022","volume":"27","author":"T Fang","year":"2021","unstructured":"Fang T, Zhang M, Yan J, Zhao J, Pan W, Wang X, et al. Comparative analysis of 3D-printed artificial vertebral body versus titanium mesh cage in repairing bone defects following single-level anterior cervical corpectomy and fusion. Med Sci Monit. 2021;27:e928022. https:\/\/doi.org\/10.12659\/MSM.928022.","journal-title":"Med Sci Monit"},{"key":"6988_CR36","doi-asserted-by":"publisher","first-page":"168","DOI":"10.1016\/j.spinee.2015.10.032","volume":"16","author":"MF Shriver","year":"2016","unstructured":"Shriver MF, Lubelski D, Sharma AM, Steinmetz MP, Benzel EC, Mroz TE. Adjacent segment degeneration and disease following cervical arthroplasty: a systematic review and meta-analysis. Spine J. 2016;16:168\u201381. https:\/\/doi.org\/10.1016\/j.spinee.2015.10.032.","journal-title":"Spine J"},{"key":"6988_CR37","doi-asserted-by":"publisher","first-page":"1549","DOI":"10.1016\/j.spinee.2017.06.010","volume":"17","author":"L Dong","year":"2017","unstructured":"Dong L, Xu Z, Chen X, Wang D, Li D, Liu T, et al. The change of adjacent segment after cervical disc arthroplasty compared with anterior cervical discectomy and fusion: a meta-analysis of randomized controlled trials. Spine J. 2017;17:1549\u201358. https:\/\/doi.org\/10.1016\/j.spinee.2017.06.010.","journal-title":"Spine J"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13018-026-06988-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-026-06988-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-026-06988-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T08:06:05Z","timestamp":1786089965000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s13018-026-06988-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,3]]},"references-count":37,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["6988"],"URL":"https:\/\/doi.org\/10.1186\/s13018-026-06988-w","relation":{},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,3]]},"assertion":[{"value":"18 January 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 May 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 June 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The study protocol received approval from the Ethics Committee of Luohe Central Hospital (approval number: LH-KY-2022-001-118). Written informed consent was obtained from all participants prior to study inclusion.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"477"}}