{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T02:13:23Z","timestamp":1788401603005,"version":"build-2803163510"},"reference-count":41,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,6,23]],"date-time":"2026-06-23T00:00:00Z","timestamp":1782172800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T00:00:00Z","timestamp":1788393600000},"content-version":"vor","delay-in-days":72,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"crossref","award":["No. 8225024"],"award-info":[{"award-number":["No. 8225024"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"crossref"}]},{"name":"Key R&D sub project of the Ministry of Science and Technology","award":["No. 2023YFF1204804"],"award-info":[{"award-number":["No. 2023YFF1204804"]}]},{"name":"Shanghai Municipal Commission of Science and Technology Explorer Program","award":["No. 23TS1400400"],"award-info":[{"award-number":["No. 23TS1400400"]}]},{"name":"Shanghai Jiao Tong University, Medicine and engineering interdisciplinary program","award":["No. YG2024LC08"],"award-info":[{"award-number":["No. YG2024LC08"]}]},{"name":"Shanghai key discipline of medical imaging","award":["No. 2017ZZ02005"],"award-info":[{"award-number":["No. 2017ZZ02005"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"DOI":"10.1186\/s13018-026-07046-1","type":"journal-article","created":{"date-parts":[[2026,6,23]],"date-time":"2026-06-23T00:36:59Z","timestamp":1782175019000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["C1 pedicle screw placement risks in patients with ponticulus posticus: a CTA retrospective simulation study"],"prefix":"10.1186","volume":"21","author":[{"given":"Ping","family":"Wang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Han","family":"Meng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lifeng","family":"Yu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ruipeng","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xinyu","family":"Song","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tiantian","family":"She","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dan","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuehua","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,6,23]]},"reference":[{"key":"7046_CR1","doi-asserted-by":"publisher","first-page":"314","DOI":"10.3171\/2018.8.SPINE18160","volume":"30","author":"G Cadena","year":"2019","unstructured":"Cadena G, Duong HT, Liu JJ, et al. Atlantoaxial fixation using C1 posterior arch screws: feasibility study, morphometric data, and biomechanical analysis. J Neurosurg Spine. 2019;30:314\u201322. https:\/\/doi.org\/10.3171\/2018.8.SPINE18160.","journal-title":"J Neurosurg Spine"},{"key":"7046_CR2","doi-asserted-by":"publisher","first-page":"775","DOI":"10.1016\/j.spinee.2013.04.005","volume":"13","author":"JS Yeom","year":"2013","unstructured":"Yeom JS, Buchowski JM, Kim HJ, et al. Risk of vertebral artery injury: comparison between C1-C2 transarticular and C2 pedicle screws. Spine J. 2013;13:775\u201385. https:\/\/doi.org\/10.1016\/j.spinee.2013.04.005.","journal-title":"Spine J"},{"key":"7046_CR3","doi-asserted-by":"publisher","first-page":"2271","DOI":"10.1016\/j.spinee.2015.07.008","volume":"15","author":"DG Huang","year":"2015","unstructured":"Huang DG, Hao DJ, He BR, et al. Posterior atlantoaxial fixation: a review of all techniques. Spine J. 2015;15:2271\u201381. https:\/\/doi.org\/10.1016\/j.spinee.2015.07.008.","journal-title":"Spine J"},{"key":"7046_CR4","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1097\/BRS.0b013e318193a21b","volume":"34","author":"XY Ma","year":"2009","unstructured":"Ma XY, Yin QS, Wu ZH, et al. C1 pedicle screws versus C1 lateral mass screws: comparisons of pullout strengths and biomechanical stabilities. Spine (Phila Pa 1976). 2009;34:371\u20137. https:\/\/doi.org\/10.1097\/BRS.0b013e318193a21b.","journal-title":"Spine (Phila Pa 1976)"},{"key":"7046_CR5","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1186\/s13018-025-05472-1","volume":"20","author":"LG Leonhardt","year":"2025","unstructured":"Leonhardt LG, Rorup L, Kammal AL, et al. Superior biomechanical stability of pedicle screws compared to lateral mass screws: recommendations for bicortical positioning and enhancing bone contact in geriatric C1 vertebrae. J Orthop Surg Res. 2025;20:63. https:\/\/doi.org\/10.1186\/s13018-025-05472-1.","journal-title":"J Orthop Surg Res"},{"key":"7046_CR6","doi-asserted-by":"publisher","first-page":"634","DOI":"10.14245\/ns.2550960.480","volume":"22","author":"SH Hwang","year":"2025","unstructured":"Hwang SH, Ryu SJ, Kim MH, et al. Atlantoaxial Reconstruction: The Artful Evolution of Craniovertebral Junctional Spine Surgery. Neurospine. 2025;22:634\u201349. https:\/\/doi.org\/10.14245\/ns.2550960.480.","journal-title":"Neurospine"},{"key":"7046_CR7","doi-asserted-by":"publisher","first-page":"822","DOI":"10.3171\/2021.8.SPINE21695","volume":"36","author":"HR Lee","year":"2022","unstructured":"Lee HR, Lee DH, Cho JH, et al. Feasibility of lateral mass screw insertion in patients with the risky triad of C1: evaluation of the over-the-arch technique. J Neurosurg Spine. 2022;36:822\u20139. https:\/\/doi.org\/10.3171\/2021.8.SPINE21695.","journal-title":"J Neurosurg Spine"},{"key":"7046_CR8","doi-asserted-by":"publisher","first-page":"774","DOI":"10.1016\/j.spinee.2024.11.012","volume":"25","author":"P Wang","year":"2025","unstructured":"Wang P, Shan Y, Yu L, et al. Potential causes of iatrogenic intraoperative bleeding during C1 surgeries: a CT 3D rendering study. Spine J. 2025;25:774\u201384. https:\/\/doi.org\/10.1016\/j.spinee.2024.11.012.","journal-title":"Spine J"},{"key":"7046_CR9","doi-asserted-by":"publisher","first-page":"1286","DOI":"10.1007\/s00586-017-5445-4","volume":"27","author":"S Xu","year":"2018","unstructured":"Xu S, Ruan S, Song X, et al. Evaluation of vertebral artery anomaly in basilar invagination and prevention of vascular injury during surgical intervention: CTA features and analysis. Eur Spine J. 2018;27:1286\u201394. https:\/\/doi.org\/10.1007\/s00586-017-5445-4.","journal-title":"Eur Spine J"},{"key":"7046_CR10","doi-asserted-by":"publisher","first-page":"e474","DOI":"10.1016\/j.wneu.2020.07.182","volume":"143","author":"T Klepinowski","year":"2020","unstructured":"Klepinowski T, Pala B, Cembik J, et al. Prevalence of High-Riding Vertebral Artery: A Meta-Analysis of the Anatomical Variant Affecting Choice of Craniocervical Fusion Method and Its Outcome. World Neurosurg. 2020;143:e474\u201381. https:\/\/doi.org\/10.1016\/j.wneu.2020.07.182.","journal-title":"World Neurosurg"},{"key":"7046_CR11","doi-asserted-by":"publisher","first-page":"276","DOI":"10.3171\/2017.1.SPINE161092","volume":"27","author":"PA Pekala","year":"2017","unstructured":"Pekala PA, Henry BM, Pekala JR, et al. Prevalence of foramen arcuale and its clinical significance: a meta-analysis of 55,985 subjects. J Neurosurg Spine. 2017;27:276\u201390. https:\/\/doi.org\/10.3171\/2017.1.SPINE161092.","journal-title":"J Neurosurg Spine"},{"key":"7046_CR12","doi-asserted-by":"publisher","first-page":"E436","DOI":"10.1097\/BRS.0000000000002400","volume":"43","author":"A Saleh","year":"2018","unstructured":"Saleh A, Gruber J, Bakhsh W, et al. How Common Is the Ponticulus Posticus? A Computed Tomography Based Analysis of 2917 Patients. Spine (Phila Pa 1976). 2018;43:E436\u201341. https:\/\/doi.org\/10.1097\/BRS.0000000000002400.","journal-title":"Spine (Phila Pa 1976)"},{"key":"7046_CR13","doi-asserted-by":"publisher","first-page":"834551","DOI":"10.3389\/fsurg.2022.834551","volume":"9","author":"X Xu","year":"2022","unstructured":"Xu X, Zhu Y, Ding X, et al. Research Progress of Ponticulus Posticus: A Narrative Literature Review. Front Surg. 2022;9:834551. https:\/\/doi.org\/10.3389\/fsurg.2022.834551.","journal-title":"Front Surg"},{"key":"7046_CR14","doi-asserted-by":"publisher","first-page":"2495","DOI":"10.2106\/JBJS.E.00184","volume":"87","author":"JP Young","year":"2005","unstructured":"Young JP, Young PH, Ackermann MJ, et al. The ponticulus posticus: implications for screw insertion into the first cervical lateral mass. J Bone Joint Surg Am. 2005;87:2495\u20138. https:\/\/doi.org\/10.2106\/JBJS.E.00184.","journal-title":"J Bone Joint Surg Am"},{"key":"7046_CR15","unstructured":"Cumhur Oner RL, Daniel Riew K, Schnake. Posterior C1\u2013C2 fusion. In: Vialle L editor. AO surgery reference, 2nd ed. Online: AO Foundation. 2024; https:\/\/surgeryreference.aofoundation.org\/spine\/trauma\/occipitocervical\/2b-nondisplaced-ligamentous-injury\/posterior-c1-c2-fusion. Accessed 22 May 2026."},{"key":"7046_CR16","doi-asserted-by":"publisher","first-page":"610","DOI":"10.1055\/s-0045-1806836","volume":"20","author":"M Fujisawa","year":"2025","unstructured":"Fujisawa M, Wakahara S, Inamasu J. Unstable Upper Cervical Spine Injury with Concomitant Bilateral Ponticulus Posticus: A Case Report. Asian J Neurosurg. 2025;20:610\u20134. https:\/\/doi.org\/10.1055\/s-0045-1806836.","journal-title":"Asian J Neurosurg"},{"key":"7046_CR17","doi-asserted-by":"publisher","first-page":"1058","DOI":"10.1007\/s00586-016-4589-y","volume":"26","author":"XL Zhang","year":"2017","unstructured":"Zhang XL, Huang DG, Wang XD, et al. The feasibility of inserting a C1 pedicle screw in patients with ponticulus posticus: a retrospective analysis of eleven patients. Eur Spine J. 2017;26:1058\u201363. https:\/\/doi.org\/10.1007\/s00586-016-4589-y.","journal-title":"Eur Spine J"},{"key":"7046_CR18","doi-asserted-by":"publisher","first-page":"E298","DOI":"10.1093\/ons\/opaa397","volume":"20","author":"YG Jung","year":"2021","unstructured":"Jung YG, Lee BJ, Park W, et al. C1-2 Pedicle Screw Fixation for Ponticulus Posticus and Duplication of Vertebral Artery: 2-Dimensional Operative Video. Oper Neurosurg. 2021;20:E298\u20139. https:\/\/doi.org\/10.1093\/ons\/opaa397.","journal-title":"Oper Neurosurg"},{"key":"7046_CR19","doi-asserted-by":"publisher","first-page":"1777","DOI":"10.1177\/15266028241229062","volume":"32","author":"P Wang","year":"2025","unstructured":"Wang P, Shan Y, Xiao B, et al. How to Omit the Potential Pitfalls in Distal Radial Access: Lessons From Cadaveric and CTA Analysis. J Endovasc Ther. 2025;32:1777\u201387. https:\/\/doi.org\/10.1177\/15266028241229062.","journal-title":"J Endovasc Ther"},{"key":"7046_CR20","unstructured":"Lasso A, PedicleScrewSimulator. Github. 2018; https:\/\/github.com\/lassoan\/PedicleScrewSimulator. Accessed 22 May 2026."},{"key":"7046_CR21","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1016\/j.spinee.2008.03.006","volume":"9","author":"CW Peng","year":"2009","unstructured":"Peng CW, Chou BT, Bendo JA, et al. Vertebral artery injury in cervical spine surgery: anatomical considerations, management, and preventive measures. Spine J. 2009;9:70\u20136. https:\/\/doi.org\/10.1016\/j.spinee.2008.03.006.","journal-title":"Spine J"},{"key":"7046_CR22","doi-asserted-by":"publisher","first-page":"654","DOI":"10.1016\/j.spinee.2011.04.022","volume":"11","author":"JW Savage","year":"2011","unstructured":"Savage JW, Limthongkul W, Park HS, et al. A comparison of biomechanical stability and pullout strength of two C1-C2 fixation constructs. Spine J. 2011;11:654\u20138. https:\/\/doi.org\/10.1016\/j.spinee.2011.04.022.","journal-title":"Spine J"},{"key":"7046_CR23","doi-asserted-by":"publisher","first-page":"1892","DOI":"10.1016\/j.spinee.2013.06.015","volume":"13","author":"CM Zarro","year":"2013","unstructured":"Zarro CM, Ludwig SC, Hsieh AH, et al. Biomechanical comparison of the pullout strengths of C1 lateral mass screws and C1 posterior arch screws. Spine J. 2013;13:1892\u20136. https:\/\/doi.org\/10.1016\/j.spinee.2013.06.015.","journal-title":"Spine J"},{"key":"7046_CR24","doi-asserted-by":"publisher","first-page":"1519","DOI":"10.1097\/01.brs.0000168546.17788.49","volume":"30","author":"XY Ma","year":"2005","unstructured":"Ma XY, Yin QS, Wu ZH, et al. Anatomic considerations for the pedicle screw placement in the first cervical vertebra. Spine (Phila Pa 1976). 2005;30:1519\u201323. https:\/\/doi.org\/10.1097\/01.brs.0000168546.17788.49.","journal-title":"Spine (Phila Pa 1976)"},{"key":"7046_CR25","doi-asserted-by":"publisher","first-page":"1651","DOI":"10.1007\/s00586-021-06744-0","volume":"30","author":"I Lvov","year":"2021","unstructured":"Lvov I, Grin A, Talypov A, et al. Fluoroscopic landmarks and trajectories for safe posterior percutaneous transarticular C1-C2 screw insertion: a CT-based simulation study. Eur Spine J. 2021;30:1651\u201361. https:\/\/doi.org\/10.1007\/s00586-021-06744-0.","journal-title":"Eur Spine J"},{"key":"7046_CR26","doi-asserted-by":"publisher","first-page":"E340","DOI":"10.1097\/BRS.0000000000001807","volume":"42","author":"T Sugawara","year":"2017","unstructured":"Sugawara T, Higashiyama N, Kaneyama S, et al. Accurate and Simple Screw Insertion Procedure With Patient-Specific Screw Guide Templates for Posterior C1-C2 Fixation. Spine (Phila Pa 1976). 2017;42:E340\u20136. https:\/\/doi.org\/10.1097\/BRS.0000000000001807.","journal-title":"Spine (Phila Pa 1976)"},{"key":"7046_CR27","doi-asserted-by":"publisher","first-page":"337","DOI":"10.3171\/2009.10.SPINE08541","volume":"12","author":"JA Thomas","year":"2010","unstructured":"Thomas JA, Tredway T, Fessler RG, et al. An alternate method for placement of C-1 screws. J Neurosurg Spine. 2010;12:337\u201341. https:\/\/doi.org\/10.3171\/2009.10.SPINE08541.","journal-title":"J Neurosurg Spine"},{"key":"7046_CR28","doi-asserted-by":"publisher","first-page":"E1133","DOI":"10.1097\/BRS.0b013e3181e215ff","volume":"35","author":"J Pan","year":"2010","unstructured":"Pan J, Li L, Qian L, et al. C1 lateral mass screw insertion with protection of C1-C2 venous sinus: technical note and review of the literature. Spine (Phila Pa 1976). 2010;35:E1133\u20131136. https:\/\/doi.org\/10.1097\/BRS.0b013e3181e215ff.","journal-title":"Spine (Phila Pa 1976)"},{"key":"7046_CR29","doi-asserted-by":"publisher","first-page":"1109","DOI":"10.1007\/s00586-014-3217-y","volume":"23","author":"DG Huang","year":"2014","unstructured":"Huang DG, He SM, Pan JW, et al. Is the 4\u00a0mm height of the vertebral artery groove really a limitation of C1 pedicle screw insertion? Eur Spine J. 2014;23:1109\u201314. https:\/\/doi.org\/10.1007\/s00586-014-3217-y.","journal-title":"Eur Spine J"},{"key":"7046_CR30","doi-asserted-by":"publisher","first-page":"15731","DOI":"10.1038\/s41598-025-99884-y","volume":"15","author":"Y Li","year":"2025","unstructured":"Li Y, Wang H, Li X, et al. Comparison of accuracy in C1-C2 pedicle screw placement: O-arm, 3D guides, and C-arm fluoroscopy. Sci Rep. 2025;15:15731. https:\/\/doi.org\/10.1038\/s41598-025-99884-y.","journal-title":"Sci Rep"},{"key":"7046_CR31","doi-asserted-by":"publisher","first-page":"269","DOI":"10.1111\/os.12136","volume":"6","author":"DG Huang","year":"2014","unstructured":"Huang DG, Hao DJ, Li GL, et al. C2 nerve dysfunction associated with C1 lateral mass screw fixation. Orthop Surg. 2014;6:269\u201373. https:\/\/doi.org\/10.1111\/os.12136.","journal-title":"Orthop Surg"},{"key":"7046_CR32","doi-asserted-by":"publisher","first-page":"E341","DOI":"10.1097\/BRS.0000000000000772","volume":"40","author":"S Kaneyama","year":"2015","unstructured":"Kaneyama S, Sugawara T, Sumi M. Safe and accurate midcervical pedicle screw insertion procedure with the patient-specific screw guide template system. Spine (Phila Pa 1976). 2015;40:E341\u2013348. https:\/\/doi.org\/10.1097\/BRS.0000000000000772.","journal-title":"Spine (Phila Pa 1976)"},{"key":"7046_CR33","doi-asserted-by":"publisher","first-page":"621","DOI":"10.1016\/j.spinee.2019.10.012","volume":"20","author":"F Muller","year":"2020","unstructured":"Muller F, Roner S, Liebmann F, et al. Augmented reality navigation for spinal pedicle screw instrumentation using intraoperative 3D imaging. Spine J. 2020;20:621\u20138. https:\/\/doi.org\/10.1016\/j.spinee.2019.10.012.","journal-title":"Spine J"},{"key":"7046_CR34","doi-asserted-by":"publisher","first-page":"E986","DOI":"10.1097\/BRS.0000000000000960","volume":"40","author":"JD van Dijk","year":"2015","unstructured":"van Dijk JD, van den Ende RP, Stramigioli S, et al. Clinical pedicle screw accuracy and deviation from planning in robot-guided spine surgery: robot-guided pedicle screw accuracy. Spine (Phila Pa 1976). 2015;40:E986\u2013991. https:\/\/doi.org\/10.1097\/BRS.0000000000000960.","journal-title":"Spine (Phila Pa 1976)"},{"key":"7046_CR35","doi-asserted-by":"publisher","first-page":"103027","DOI":"10.1016\/j.media.2023.103027","volume":"91","author":"F Liebmann","year":"2024","unstructured":"Liebmann F, von Atzigen M, Stutz D, et al. Automatic registration with continuous pose updates for marker-less surgical navigation in spine surgery. Med Image Anal. 2024;91:103027. https:\/\/doi.org\/10.1016\/j.media.2023.103027.","journal-title":"Med Image Anal"},{"key":"7046_CR36","doi-asserted-by":"publisher","first-page":"514","DOI":"10.14245\/ns.2550110.055","volume":"22","author":"Y Yamamoto","year":"2025","unstructured":"Yamamoto Y, Nishimura Y, Ishii M, Fukaya N, Tsukamoto E, Saito R, Hara M, Takayasu M. Optimization of paravertebral foramen screw placement: a stepwise approach considering O-arm navigation errors: technical note and case series. Neurospine. 2025;22:514\u201322. https:\/\/doi.org\/10.14245\/ns.2550110.055.","journal-title":"Neurospine"},{"key":"7046_CR37","doi-asserted-by":"publisher","first-page":"2304","DOI":"10.1007\/s00586-024-08232-7","volume":"33","author":"J Gierse","year":"2024","unstructured":"Gierse J, Mandelka E, Medrow A, Bullert B, Gruetzner PA, Franke J, Vetter SY. Comparison of iCT-based navigation and fluoroscopic-guidance for atlantoaxial screw placement in 78 patients with traumatic cervical spine injuries. Eur Spine J. 2024;33:2304\u201313. https:\/\/doi.org\/10.1007\/s00586-024-08232-7.","journal-title":"Eur Spine J"},{"key":"7046_CR38","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1016\/j.spinee.2024.08.021","volume":"25","author":"T Klepinowski","year":"2025","unstructured":"Klepinowski T, Zylka N, Pettersson SD, et al. Types of high-riding vertebral artery: a classification system for preoperative planning of C2 instrumentation based on 908 potential screw insertion sites. Spine J. 2025;25:59\u201368. https:\/\/doi.org\/10.1016\/j.spinee.2024.08.021.","journal-title":"Spine J"},{"key":"7046_CR39","doi-asserted-by":"publisher","first-page":"1263","DOI":"10.1007\/s00586-025-08700-8","volume":"34","author":"LF Holler","year":"2025","unstructured":"Holler LF, Holler S, Jackle K, Roch PJ, Lehmann W, Weiser L. Revealing the potential: radiological assessment of pedicle screw placement in the craniocervical junction and upper cervical spine. Eur Spine J. 2025;34:1263\u20139. https:\/\/doi.org\/10.1007\/s00586-025-08700-8.","journal-title":"Eur Spine J"},{"key":"7046_CR40","doi-asserted-by":"publisher","first-page":"281","DOI":"10.3171\/2020.2.SPINE191517","volume":"33","author":"YQ Du","year":"2020","unstructured":"Du YQ, Yin YH, Qiao GY, Yu XG. C2 medial pedicle screw: a novel in-out-in technique as an alternative option for posterior C2 fixation in cases with a narrow C2 isthmus. J Neurosurg Spine. 2020;33:281\u20137. https:\/\/doi.org\/10.3171\/2020.2.SPINE191517.","journal-title":"J Neurosurg Spine"},{"key":"7046_CR41","doi-asserted-by":"publisher","first-page":"667","DOI":"10.1186\/s13018-025-06095-2","volume":"20","author":"XH Lian","year":"2025","unstructured":"Lian XH, He W, Sun WJ, et al. Biomechanical evaluation of In-Out-In pedicle screws for atlantoaxial posterior fixation in the presence of high-riding vertebral artery and narrow C2 pedicles: a finite element analysis. J Orthop Surg Res. 2025;20:667. https:\/\/doi.org\/10.1186\/s13018-025-06095-2.","journal-title":"J Orthop Surg Res"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13018-026-07046-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-026-07046-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-026-07046-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T01:23:30Z","timestamp":1788398610000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s13018-026-07046-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,23]]},"references-count":41,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["7046"],"URL":"https:\/\/doi.org\/10.1186\/s13018-026-07046-1","relation":{},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,23]]},"assertion":[{"value":"12 April 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 June 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 June 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"All CTA images were obtained at, and remained within, a single institutional imaging archive; no images left the hospital or entered the public domain. The first author (PW) was affiliated with Tarim University, and the study protocol was reviewed and approved by the institutional review board of Tarim University (approval number 2024041502), which remained the IRB of record for this retrospective analysis after his subsequent affiliation change to Shanghai Sixth People\u2019s Hospital. No additional center contributed imaging data; the work is therefore single-center retrospective imaging research. Informed consent for retrospective research use was waived.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"530"}}