{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,5]],"date-time":"2025-11-05T21:00:07Z","timestamp":1762376407801,"version":"3.37.3"},"reference-count":17,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2018,6,19]],"date-time":"2018-06-19T00:00:00Z","timestamp":1529366400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Cardiothorac Surg"],"published-print":{"date-parts":[[2018,12]]},"DOI":"10.1186\/s13019-018-0759-9","type":"journal-article","created":{"date-parts":[[2018,6,19]],"date-time":"2018-06-19T06:51:51Z","timestamp":1529391111000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Controller and battery changes due to technical problems related to the HVAD\u00ae left ventricular assist device - a single center experience"],"prefix":"10.1186","volume":"13","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8066-2423","authenticated-orcid":false,"given":"Emil","family":"Najjar","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ann","family":"Hallberg Kristensen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tonje","family":"Thorvaldsen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Laila","family":"Hubbert","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peter","family":"Svenarud","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Magnus","family":"Dal\u00e9n","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Agneta","family":"M\u00e5nsson Broberg","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lars H.","family":"Lund","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2018,6,19]]},"reference":[{"issue":"14","key":"759_CR1","doi-asserted-by":"publisher","first-page":"1787","DOI":"10.1093\/eurheartj\/ehs104","volume":"33","author":"JJ McMurray","year":"2012","unstructured":"McMurray JJ, et al. ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure 2012: The Task Force for the Diagnosis and Treatment of Acute and Chronic Heart Failure 2012 of the European Society of Cardiology Developed in collaboration with the Heart Failure Association (HFA) of the ESC. Eur Heart J. 2012;33(14):1787\u2013847.","journal-title":"Eur Heart J"},{"issue":"14","key":"759_CR2","doi-asserted-by":"publisher","first-page":"1418","DOI":"10.1056\/NEJMsa0803563","volume":"360","author":"SF Jencks","year":"2009","unstructured":"Jencks SF, Williams MV, Coleman EA. Rehospitalizations among patients in the Medicare fee-for-service program. N Engl J Med. 2009;360(14):1418\u201328.","journal-title":"N Engl J Med"},{"issue":"15","key":"759_CR3","doi-asserted-by":"publisher","first-page":"1669","DOI":"10.1001\/jama.2011.1474","volume":"306","author":"J Chen","year":"2011","unstructured":"Chen J, et al. National and regional trends in heart failure hospitalization and mortality rates for Medicare beneficiaries, 1998-2008. JAMA. 2011;306(15):1669\u201378.","journal-title":"JAMA"},{"issue":"12","key":"759_CR4","doi-asserted-by":"publisher","first-page":"1495","DOI":"10.1016\/j.healun.2015.10.003","volume":"34","author":"JK Kirklin","year":"2015","unstructured":"Kirklin JK, et al. Seventh INTERMACS annual report: 15,000 patients and counting. J Heart Lung Transplant. 2015;34(12):1495\u2013504.","journal-title":"J Heart Lung Transplant"},{"issue":"5","key":"759_CR5","doi-asserted-by":"publisher","first-page":"434","DOI":"10.1093\/eurjhf\/hfq006","volume":"12","author":"LH Lund","year":"2010","unstructured":"Lund LH, Matthews J, Aaronson K. Patient selection for left ventricular assist devices. Eur J Heart Fail. 2010;12(5):434\u201343.","journal-title":"Eur J Heart Fail"},{"issue":"25","key":"759_CR6","doi-asserted-by":"publisher","first-page":"3191","DOI":"10.1161\/CIRCULATIONAHA.111.058412","volume":"125","author":"KD Aaronson","year":"2012","unstructured":"Aaronson KD, et al. Use of an intrapericardial, continuous-flow, centrifugal pump in patients awaiting heart transplantation. Circulation. 2012;125(25):3191\u2013200.","journal-title":"Circulation"},{"issue":"5","key":"759_CR7","doi-asserted-by":"publisher","first-page":"1593","DOI":"10.1016\/j.athoracsur.2011.06.081","volume":"92","author":"R John","year":"2011","unstructured":"John R, et al. Lessons learned from experience with over 100 consecutive HeartMate II left ventricular assist devices. Ann Thorac Surg. 2011;92(5):1593\u20139. discussion 1599\u2013600","journal-title":"Ann Thorac Surg"},{"issue":"23","key":"759_CR8","doi-asserted-by":"publisher","first-page":"2241","DOI":"10.1056\/NEJMoa0909938","volume":"361","author":"MS Slaughter","year":"2009","unstructured":"Slaughter MS, et al. Advanced heart failure treated with continuous-flow left ventricular assist device. N Engl J Med. 2009;361(23):2241\u201351.","journal-title":"N Engl J Med"},{"issue":"12","key":"759_CR9","doi-asserted-by":"publisher","first-page":"1375","DOI":"10.1016\/j.jacc.2010.10.040","volume":"57","author":"M Strueber","year":"2011","unstructured":"Strueber M, et al. Multicenter evaluation of an intrapericardial left ventricular assist system. J Am Coll Cardiol. 2011;57(12):1375\u201382.","journal-title":"J Am Coll Cardiol"},{"issue":"1","key":"759_CR10","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1016\/j.jtcvs.2015.09.100","volume":"151","author":"JM Stulak","year":"2016","unstructured":"Stulak JM, et al. Adverse events in contemporary continuous-flow left ventricular assist devices: a multi-institutional comparison shows significant differences. J Thorac Cardiovasc Surg. 2016;151(1):177\u201389.","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"5","key":"759_CR11","doi-asserted-by":"publisher","first-page":"440","DOI":"10.1056\/NEJMoa1610426","volume":"376","author":"MR Mehra","year":"2017","unstructured":"Mehra MR, et al. A fully magnetically levitated circulatory pump for advanced heart failure. N Engl J Med. 2017;376(5):440\u201350.","journal-title":"N Engl J Med"},{"issue":"5","key":"759_CR12","doi-asserted-by":"publisher","first-page":"486","DOI":"10.1016\/j.healun.2014.01.856","volume":"33","author":"M Strueber","year":"2014","unstructured":"Strueber M, et al. Results of the post-market registry to evaluate the HeartWare left ventricular assist system (ReVOLVE). J Heart Lung Transplant. 2014;33(5):486\u201391.","journal-title":"J Heart Lung Transplant"},{"issue":"5","key":"759_CR13","doi-asserted-by":"publisher","first-page":"755","DOI":"10.1016\/j.jamcollsurg.2008.11.016","volume":"208","author":"WL Holman","year":"2009","unstructured":"Holman WL, et al. INTERMACS: interval analysis of registry data. J Am Coll Surg. 2009;208(5):755\u201361. discussion 761\u20132","journal-title":"J Am Coll Surg"},{"issue":"5","key":"759_CR14","doi-asserted-by":"publisher","first-page":"451","DOI":"10.1056\/NEJMoa1602954","volume":"376","author":"JG Rogers","year":"2017","unstructured":"Rogers JG, et al. Intrapericardial left ventricular assist device for advanced heart failure. N Engl J Med. 2017;376(5):451\u201360.","journal-title":"N Engl J Med"},{"issue":"7","key":"759_CR15","doi-asserted-by":"publisher","first-page":"675","DOI":"10.1016\/j.healun.2013.04.004","volume":"32","author":"MS Slaughter","year":"2013","unstructured":"Slaughter MS, et al. HeartWare ventricular assist system for bridge to transplant: combined results of the bridge to transplant and continued access protocol trial. J Heart Lung Transplant. 2013;32(7):675\u201383.","journal-title":"J Heart Lung Transplant"},{"unstructured":"FDA. HeartWare Ventricular Assist Device (HVAD) Pumps by HeartWare Inc. Class I Recall - Loose Connectors May Prevent Alarm from Sounding. 2016. Available from: \n                    https:\/\/www.fda.gov\/medicaldevices\/safety\/listofrecalls\/ucm529494.htm\n                    \n                  .","key":"759_CR16"},{"unstructured":"FDA. HeartWare Ventricular Assist Device (HVAD) Batteries by HeartWare Inc. Class I Recall - Premature Power Depletion. 2016. Available from: \n                    https:\/\/www.fda.gov\/medicaldevices\/safety\/listofrecalls\/ucm509185.htm\n                    \n                  .","key":"759_CR17"}],"container-title":["Journal of Cardiothoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s13019-018-0759-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s13019-018-0759-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s13019-018-0759-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,6,18]],"date-time":"2019-06-18T19:29:58Z","timestamp":1560886198000},"score":1,"resource":{"primary":{"URL":"https:\/\/cardiothoracicsurgery.biomedcentral.com\/articles\/10.1186\/s13019-018-0759-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,6,19]]},"references-count":17,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2018,12]]}},"alternative-id":["759"],"URL":"https:\/\/doi.org\/10.1186\/s13019-018-0759-9","relation":{},"ISSN":["1749-8090"],"issn-type":[{"type":"electronic","value":"1749-8090"}],"subject":[],"published":{"date-parts":[[2018,6,19]]},"assertion":[{"value":"19 February 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 June 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 June 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The study complies with the Declaration of Helsinki and was approved by the regional ethical review board (Dnr2016\/2576\u201332). There was no need to have informed consent since the study was a retrospective analysis of available data from patients with LVADs.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"LHL: No disclosures directly related to the present work. Unrelated disclosures are: Research grants from Astra Zeneca, Boston Scientific; consulting or speaker\u2019s honoraria from Novartis, Astra Zeneca, Bayer, St Jude, Medtronic, HeartWare, Vifor Pharma.LH: No disclosures directly related to the present work. Unrelated disclosures are: speaker\u2019s honoraria from MSD and Novartis.Other authors none.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Publisher\u2019s Note"}}],"article-number":"74"}}