{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,11]],"date-time":"2026-03-11T05:47:18Z","timestamp":1773208038663,"version":"3.50.1"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2018,6,25]],"date-time":"2018-06-25T00:00:00Z","timestamp":1529884800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001652","name":"Friedrich-Alexander-Universit\u00e4t Erlangen-N\u00fcrnberg","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100001652","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Cardiothorac Surg"],"published-print":{"date-parts":[[2018,12]]},"DOI":"10.1186\/s13019-018-0767-9","type":"journal-article","created":{"date-parts":[[2018,6,25]],"date-time":"2018-06-25T11:40:18Z","timestamp":1529926818000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":30,"title":["The EZ-blocker for one-lung ventilation in patients undergoing thoracic surgery: clinical applications and experience in 100 cases in a routine clinical setting"],"prefix":"10.1186","volume":"13","author":[{"given":"Andreas","family":"Moritz","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrea","family":"Irouschek","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Torsten","family":"Birkholz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Johannes","family":"Prottengeier","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Horia","family":"Sirbu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joachim","family":"Schmidt","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2018,6,25]]},"reference":[{"key":"767_CR1","doi-asserted-by":"publisher","first-page":"705","DOI":"10.1016\/1053-0770(92)90056-D","volume":"6","author":"JW Lewis","year":"1992","unstructured":"Lewis JW, Serwin JP, Gabriel FS, Bastanfar M, Jacobsen G. The utility of a double-lumen tube for one-lung ventilation in a variety of noncardiac thoracic surgical procedures. J Cardiothorac Vasc Anesth. 1992;6:705\u201310.","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"767_CR2","doi-asserted-by":"publisher","first-page":"471","DOI":"10.1097\/00000542-200609000-00009","volume":"105","author":"H Knoll","year":"2006","unstructured":"Knoll H, Ziegeler S, Schreiber JU, et al. Airway injuries after one-lung ventilation: a comparison between double-lumen tube and endobronchial blocker: a randomized, prospective, controlled trial. Anesthesiology. 2006;105:471\u20137.","journal-title":"Anesthesiology"},{"key":"767_CR3","doi-asserted-by":"publisher","first-page":"322","DOI":"10.1016\/S1053-0770(99)90273-2","volume":"13","author":"BG Fitzmaurice","year":"1999","unstructured":"Fitzmaurice BG, Brodsky JB. Airway rupture from double-lumen tubes. J Cardiothorac Vasc Anesth. 1999;13:322\u20139.","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"767_CR4","doi-asserted-by":"publisher","first-page":"1266","DOI":"10.1213\/01.ANE.0000085301.87286.59","volume":"97","author":"JH Campos","year":"2003","unstructured":"Campos JH. An update on bronchial blockers during lung separation techniques in adults. Anesth Analg. 2003;97:1266\u201374.","journal-title":"Anesth Analg"},{"key":"767_CR5","doi-asserted-by":"publisher","first-page":"1877","DOI":"10.1213\/01.ANE.0000184116.86888.D9","volume":"101","author":"E Cohen","year":"2005","unstructured":"Cohen E. The Cohen flexitip endobronchial blocker: an alternative to a double lumen tube. Anesth Analg. 2005;101:1877\u20139.","journal-title":"Anesth Analg"},{"key":"767_CR6","doi-asserted-by":"crossref","first-page":"940","DOI":"10.1016\/S0022-5223(19)37196-X","volume":"83","author":"H Inoue","year":"1982","unstructured":"Inoue H, Shohtsu A, Ogawa J, Kawada S, Koide S. New device for one-lung anesthesia: endotracheal tube with movable blocker. J Thorac Cardiovasc Surg. 1982;83:940\u20131.","journal-title":"J Thorac Cardiovasc Surg"},{"key":"767_CR7","doi-asserted-by":"publisher","first-page":"356","DOI":"10.1034\/j.1399-6576.1999.430320.x","volume":"43","author":"GA Arndt","year":"1999","unstructured":"Arndt GA, DeLessio ST, Kranner PW, Orzepowski W, Ceranski B, Valtysson B. One-lung ventilation when intubation is difficult--presentation of a new endobronchial blocker. Acta Anaesthesiol Scand. 1999;43:356\u20138.","journal-title":"Acta Anaesthesiol Scand"},{"key":"767_CR8","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1177\/0310057X0903700612","volume":"37","author":"T Zhong","year":"2009","unstructured":"Zhong T, Wang W, Chen J, Ran L. Story DA sore throat or hoarse voice with bronchial blockers or double-lumen tubes for lung isolation: a randomised prospective trial. Anaesth Intensive Care. 2009;37:441\u20136.","journal-title":"Anaesth Intensive Care"},{"key":"767_CR9","doi-asserted-by":"publisher","first-page":"283","DOI":"10.1213\/00000539-200301000-00056","volume":"96","author":"JH Campos","year":"2003","unstructured":"Campos JH, Kernstine KH. A comparison of a left-sided Broncho-Cath with the torque control blocker univent and the wire-guided blocker. Anesth Analg. 2003;96:283\u20139. table of contents","journal-title":"Anesth Analg"},{"key":"767_CR10","doi-asserted-by":"publisher","first-page":"1097","DOI":"10.1213\/ane.0b013e3181999339","volume":"108","author":"M Narayanaswamy","year":"2009","unstructured":"Narayanaswamy M, McRae K, Slinger P, et al. Choosing a lung isolation device for thoracic surgery: a randomized trial of three bronchial blockers versus double-lumen tubes. Anesth Analg. 2009;108:1097\u2013101.","journal-title":"Anesth Analg"},{"key":"767_CR11","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1097\/ACO.0b013e3280111e2a","volume":"20","author":"JH Campos","year":"2007","unstructured":"Campos JH. Which device should be considered the best for lung isolation: double-lumen endotracheal tube versus bronchial blockers. Curr Opin Anaesthesiol. 2007;20:27\u201331.","journal-title":"Curr Opin Anaesthesiol"},{"key":"767_CR12","doi-asserted-by":"publisher","first-page":"896","DOI":"10.1053\/j.jvca.2013.02.006","volume":"28","author":"A Kus","year":"2014","unstructured":"Kus A, Hosten T, Gurkan Y, Gul Akgul A, Solak M, Toker K. A comparison of the EZ-blocker with a Cohen flex-tip blocker for one-lung ventilation. J Cardiothorac Vasc Anesth. 2014;28:896\u20139.","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"767_CR13","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1097\/ACC.0b013e318291d364","volume":"1","author":"JB Brodsky","year":"2013","unstructured":"Brodsky JB, Tzabazis A, Basarb-Tung J, Shrager JB. Sequential bilateral lung isolation with a single bronchial blocker. A A Case Rep. 2013;1:17\u20138.","journal-title":"A A Case Rep"},{"key":"767_CR14","doi-asserted-by":"publisher","first-page":"288","DOI":"10.1016\/j.jclinane.2016.02.008","volume":"31","author":"M Rispoli","year":"2016","unstructured":"Rispoli M, Nespoli MR, Salvi R, Corcione A, Buono S. One-lung ventilation in tracheostomized patients: our experience with EZ-blocker. J Clin Anesth. 2016;31:288\u201390.","journal-title":"J Clin Anesth"},{"key":"767_CR15","doi-asserted-by":"publisher","first-page":"2946","DOI":"10.1007\/s00268-012-1700-3","volume":"36","author":"J Schmidt","year":"2012","unstructured":"Schmidt J, Irouschek A, Heinrich S, Oster O, Klein P, Birkholz T. Recurrent laryngeal nerve monitoring during esophagectomy and mediastinal lymph node dissection: a novel approach using a single-lumen endotracheal EMG tube and the EZ-blocker. World J Surg. 2012;36:2946\u20137. author reply 8","journal-title":"World J Surg"},{"key":"767_CR16","doi-asserted-by":"publisher","first-page":"601","DOI":"10.1016\/0002-9610(84)90122-3","volume":"147","author":"MJ O'Reilly","year":"1984","unstructured":"O'Reilly MJ, Reddick EJ, Black W, et al. Sepsis from sinusitis in nasotracheally intubated patients A diagnostic dilemma. Am J Surg. 1984;147:601\u20134.","journal-title":"Am J Surg"},{"key":"767_CR17","doi-asserted-by":"publisher","first-page":"896","DOI":"10.1093\/bja\/aer086","volume":"106","author":"K Ruetzler","year":"2011","unstructured":"Ruetzler K, Grubhofer G, Schmid W, et al. Randomized clinical trial comparing double-lumen tube and EZ-blocker for single-lung ventilation. Br J Anaesth. 2011;106:896\u2013902.","journal-title":"Br J Anaesth"},{"key":"767_CR18","doi-asserted-by":"publisher","first-page":"550","DOI":"10.1097\/ALN.0b013e3182834f2d","volume":"118","author":"J Mourisse","year":"2013","unstructured":"Mourisse J, Liesveld J, Verhagen A, et al. Efficiency, efficacy, and safety of EZ-blocker compared with left-sided double-lumen tube for one-lung ventilation. Anesthesiology. 2013;118:550\u201361.","journal-title":"Anesthesiology"},{"key":"767_CR19","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1186\/s13054-014-0730-7","volume":"19","author":"J Elmer","year":"2015","unstructured":"Elmer J, Lee S, Rittenberger JC, Dargin J, Winger D, Emlet L. Reintubation in critically ill patients: procedural complications and implications for care. Crit Care. 2015;19:12.","journal-title":"Crit Care"},{"key":"767_CR20","doi-asserted-by":"publisher","first-page":"347","DOI":"10.1111\/pan.13342","volume":"28","author":"TW Templeton","year":"2018","unstructured":"Templeton TW, Templeton LB, Lawrence AE, Sieren LM, Downard MG, Ririe DG. An initial experience with an Extraluminal EZ-blocker. Paediatr Anaesth. 2018;28:347\u201351.","journal-title":"Paediatr Anaesth"},{"key":"767_CR21","doi-asserted-by":"crossref","unstructured":"Wald SH, Mahajan A, Kaplan MB, Atkinson JB. Experience with the Arndt paediatric bronchial blocker. Br J Anaesth. 2005;94:92\u20134.","DOI":"10.1093\/bja\/aeh292"},{"key":"767_CR22","doi-asserted-by":"publisher","first-page":"490","DOI":"10.1097\/ALN.0b013e3182839981","volume":"118","author":"E Cohen","year":"2013","unstructured":"Cohen E. Back to blockers?: the continued search for the ideal endobronchial blocker. Anesthesiology. 2013;118:490\u20133.","journal-title":"Anesthesiology"},{"key":"767_CR23","doi-asserted-by":"publisher","first-page":"375","DOI":"10.1007\/s00540-011-1315-0","volume":"26","author":"T V\u00e9gh","year":"2012","unstructured":"V\u00e9gh T, Juh\u00e1sz M, Enyedi A, Tak\u00e1cs I, Koll\u00e1r J, F\u00fclesdi B. Clinical experience with a new endobrochial blocker: the EZ-blocker. J Anesth. 2012;26:375\u201380.","journal-title":"J Anesth"}],"container-title":["Journal of Cardiothoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s13019-018-0767-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s13019-018-0767-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s13019-018-0767-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,11,4]],"date-time":"2020-11-04T07:18:22Z","timestamp":1604474302000},"score":1,"resource":{"primary":{"URL":"https:\/\/cardiothoracicsurgery.biomedcentral.com\/articles\/10.1186\/s13019-018-0767-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,6,25]]},"references-count":23,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2018,12]]}},"alternative-id":["767"],"URL":"https:\/\/doi.org\/10.1186\/s13019-018-0767-9","relation":{},"ISSN":["1749-8090"],"issn-type":[{"value":"1749-8090","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,6,25]]},"assertion":[{"value":"13 March 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 June 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 June 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Prior to this study, the local ethics committee (Ethics Committee of the Friedrich-Alexander University Erlangen-N\u00fcrnberg) confirmed that no further patients consent and institutional ethical approval were required. This decision was based on the retrospective, descriptive and anonymous study design and the fully closed patient files.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Publisher\u2019s Note"}}],"article-number":"77"}}