{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,3,27]],"date-time":"2025-03-27T08:28:57Z","timestamp":1743064137450,"version":"3.37.3"},"reference-count":5,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,4,19]],"date-time":"2020-04-19T00:00:00Z","timestamp":1587254400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2020,4,19]],"date-time":"2020-04-19T00:00:00Z","timestamp":1587254400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100003847","name":"Ningbo Municipal People's Government","doi-asserted-by":"publisher","award":["PPXK2018-05"],"award-info":[{"award-number":["PPXK2018-05"]}],"id":[{"id":"10.13039\/501100003847","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Cardiothorac Surg"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n<jats:title>Background<\/jats:title>\n<jats:p>CT-guided hook wire has been recognized to be a safe and effective percutaneous localizer to identify small pulmonary lesions with ground-glass opacity (GGO) component, while several association complications including pneumothorax, hemothorax, intrapulmonary hemorrhaging, aeroembolism and dislodgement have been reproted. However, sliding into pulmonary artery is an extremly rare comlication of hook wire localization.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Case presentation<\/jats:title>\n<jats:p>A 61-year-old male suffered from multiple pulmonary nodules received right upper lobectomy and right lower lobe wedge resection by video-assisted thoracic surgery (VATS) 3\u2009months ago. Since it might be difficult to identify the ground-glass opacity located in the right lower lobe, a CT-guided hook wire was placed before surgery. During the operation, the hook wire unexpectedly slided into left upper lobe pulmonary artery. With the help of vascular surgery department, the hook wire was extracted by interventional therapy under digital substraction angiography (DSA). The patient was eventually recovered and discharged.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Conclusions<\/jats:title>\n<jats:p>During localization procedure, the tip of hook wire should be far from pulmonary vessels. At the beginning of the operation, the hook wire might as well be removed first. Even if the hook wire was still required to be in the pulmonary parenchyma, it should be fixed to the pleural by a titanic clip or a hemolock clip.<\/jats:p>\n<\/jats:sec>","DOI":"10.1186\/s13019-020-01105-2","type":"journal-article","created":{"date-parts":[[2020,4,19]],"date-time":"2020-04-19T16:02:21Z","timestamp":1587312141000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["A hook wire sliding into pulmonary artery and being extracted under DSA: a case report about a rare complication associated with lung nodule localization"],"prefix":"10.1186","volume":"15","author":[{"given":"Xu","family":"Song","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jie","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Di","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,4,19]]},"reference":[{"issue":"2","key":"1105_CR1","doi-asserted-by":"publisher","first-page":"279","DOI":"10.2214\/ajr.161.2.8333361","volume":"161","author":"RM Shah","year":"1993","unstructured":"Shah RM, Spirn PW, Salazar AM, et al. Localization of peripheral pulmonary nodules for thoracoscopic excision: value of CT-guided wire placement. Am J Roentgenol. 1993;161(2):279\u201383. https:\/\/doi.org\/10.2214\/ajr.161.2.8333361.","journal-title":"Am J Roentgenol"},{"issue":"4","key":"1105_CR2","doi-asserted-by":"publisher","first-page":"1203","DOI":"10.1016\/j.athoracsur.2013.05.026","volume":"96","author":"J Ichinose","year":"2013","unstructured":"Ichinose J, Kohno T, Fujimori S, et al. Efficacy and complications of computed tomography-guided hook wire localization. Ann Thorac Surg. 2013;96(4):1203\u20138. https:\/\/doi.org\/10.1016\/j.athoracsur.2013.05.026.","journal-title":"Ann Thorac Surg"},{"key":"1105_CR3","doi-asserted-by":"publisher","unstructured":"Park CH, Han K, Hur J, et al. Comparative effectiveness and safety of pre-operative lung localization for pulmonary nodules: a systematic review and meta-analysis. Chest. 2016;S0012369216593106. https:\/\/doi.org\/10.1016\/j.chest.2016.09.017.","DOI":"10.1016\/j.chest.2016.09.017"},{"issue":"3","key":"1105_CR4","doi-asserted-by":"publisher","first-page":"53","DOI":"10.21037\/atm.2018.12.49","volume":"7","author":"Z Shi","year":"2019","unstructured":"Shi Z, Jin Y, Chen C, et al. Ann Transl Med. 2019;7(3):53. https:\/\/doi.org\/10.21037\/atm.2018.12.49.","journal-title":"Ann Transl Med"},{"key":"1105_CR5","doi-asserted-by":"publisher","unstructured":"Kleedehn M, Kim DH, Lee FT, et al. Preoperative pulmonary nodule localization: a comparison of methylene blue and Hookwire techniques. Am J Roentgenol. 2016:1\u20136. https:\/\/doi.org\/10.2214\/AJR.16.16272.","DOI":"10.2214\/AJR.16.16272"}],"container-title":["Journal of Cardiothoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13019-020-01105-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13019-020-01105-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13019-020-01105-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,4,18]],"date-time":"2021-04-18T23:27:33Z","timestamp":1618788453000},"score":1,"resource":{"primary":{"URL":"https:\/\/cardiothoracicsurgery.biomedcentral.com\/articles\/10.1186\/s13019-020-01105-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,4,19]]},"references-count":5,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["1105"],"URL":"https:\/\/doi.org\/10.1186\/s13019-020-01105-2","relation":{},"ISSN":["1749-8090"],"issn-type":[{"type":"electronic","value":"1749-8090"}],"subject":[],"published":{"date-parts":[[2020,4,19]]},"assertion":[{"value":"20 January 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 April 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 April 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This case report was reviewed and approved by human research ethics commette of Hwa Mei hospital, University of Chinese academy of sciences (No. PJ-NBEY-KY-2019-154-01). There is an informed consent form about publishing from the patient himself.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"There is an informed consent from the patient to publish (V 1.0).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"63"}}