{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,27]],"date-time":"2026-02-27T04:24:56Z","timestamp":1772166296753,"version":"3.50.1"},"reference-count":10,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,9,16]],"date-time":"2020-09-16T00:00:00Z","timestamp":1600214400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,9,16]],"date-time":"2020-09-16T00:00:00Z","timestamp":1600214400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Cardiothorac Surg"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Pocket-related complications following the implantation of cardiovascular implantable electronic devices primarily include pocket hematoma, infection, skin erosion or decubitus, device migration, and Twiddler's syndrome, with other pathologies such as nerve impairment or bone lesions being extremely rarely encountered. We report a case of a 20-year old asthenic, non-athlete female patient presenting with a device-generated fracture of the second rib several months after sub-muscular permanent pacemaker implantation due to repeated bilateral pre-pectoral pocket infections.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Case presentation<\/jats:title>\n                    <jats:p>A 20-year old female patient was readmitted to our institution 9\u00a0months following sub-pectoral implantation of a permanent pacemaker, complaining of severe pocket-related pain, which arose spontaneously in the absence of direct trauma, intense physical activity or vigorous coughing, and was associated with normal day-to-day activity. To rule out a pacemaker re-infection, a native computed tomography and a positron emission tomography\u2014computed tomography of the thorax were performed. Both modalities excluded an infection but showed a healing fracture and a focus of enhanced metabolic activity in the anterolateral part of the right second rib, indicating a non-traumatic or stress fracture of the bone. Consequently, a complete extraction of the pulse generator and both leads was performed and the smallest available single-chamber pulse generator with a single atrial electrode was implanted in the sub-fascial, pre-muscular pocket in the now recovered and uninfected left subclavicular region, alleviating patient\u2019s severe pain symptoms and significantly enhancing her quality of life.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>In the absence of direct trauma, intense physical activity or vigorous coughing, we assume that in this asthenic girl a normal day-to-day motion of the right shoulder has persistently forced the sub-muscularly placed pulse generator toward thoracic wall, putting increased repetitive pressure force on the underlying bones, finally causing a fatigue stress fracture of the second rib. In asthenic phenotype patients with small thorax and short subclavicular distance, a sub-muscular pacemaker implantation can potentially cause unique and unexpected pocket-related adverse events necessitating advanced diagnostics and timely treatment.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s13019-020-01303-y","type":"journal-article","created":{"date-parts":[[2020,9,16]],"date-time":"2020-09-16T07:05:01Z","timestamp":1600239901000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Pacemaker-generated stress fracture of the second rib: a case report"],"prefix":"10.1186","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9297-8492","authenticated-orcid":false,"given":"Jus","family":"Ksela","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mark","family":"Racman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rok","family":"Zbacnik","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anze","family":"Djordjevic","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Matevz","family":"Jan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,9,16]]},"reference":[{"issue":"3","key":"1303_CR1","first-page":"42","volume":"3","author":"M Kotsakou","year":"2015","unstructured":"Kotsakou M, Kioumis I, Lazaridis G, et al. Pacemaker insertion Ann Transl Med. 2015;3(3):42. .","journal-title":"Pacemaker insertion Ann Transl Med"},{"key":"1303_CR2","unstructured":"Gul EE, Kayrak M. Common Pacemaker Problems: Lead and Pocket Complications. Modern Pacemakers - Present and Future, Prof. Das MR (Ed.), ISBN: 978\u2013953\u2013307\u2013214\u20132, InTech, 2011. Available from: https:\/\/www.intechopen.com\/books\/modern-pacemakers-present-and-future\/commonpacemaker-problems-lead-and-pocket-complications."},{"issue":"5","key":"1303_CR3","doi-asserted-by":"publisher","first-page":"428","DOI":"10.4070\/kcj.2015.45.5.428","volume":"45","author":"SY Kim","year":"2015","unstructured":"Kim SY, Park JS, Bang JH, et al. Brachial Plexus Injury Caused by Indwelling Axillary Venous Pacing Leads. Korean Circ J. 2015;45(5):428\u201331. .","journal-title":"Korean Circ J"},{"key":"1303_CR4","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1016\/j.ihj.2015.07.013","volume":"67","author":"S Kamath","year":"2015","unstructured":"Kamath S, Rao BS. Complex regional pain syndrome type I following pacemaker implantation. Indian Heart J. 2015;67:103\u20136. .","journal-title":"Indian Heart J"},{"issue":"10","key":"1303_CR5","doi-asserted-by":"publisher","first-page":"614","DOI":"10.1097\/00003072-200410000-00002","volume":"29","author":"LP Connolly","year":"2004","unstructured":"Connolly LP, Connolly SA. Rib Stress Fractures. Clin Nucl Med. 2004;29(10):614\u20136. .","journal-title":"Clin Nucl Med"},{"issue":"4","key":"1303_CR6","doi-asserted-by":"publisher","first-page":"365","DOI":"10.1007\/s10140-016-1390-5","volume":"23","author":"GR Matcuk","year":"2016","unstructured":"Matcuk GR, Mahanty SR, Skalski MR, et al. Stress fractures: pathophysiology, clinical presentation, imaging features, and treatment options. Emerg Radiol. 2016;23(4):365\u201375. .","journal-title":"Emerg Radiol"},{"issue":"6","key":"1303_CR7","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1016\/j.athoracsur.2010.02.035","volume":"69","author":"GS Kamath","year":"2010","unstructured":"Kamath GS, Borkar S, Chauhan A, et al. Isolated cervical rib fracture. Ann Thorac Surg. 2010;69(6):41\u20132. .","journal-title":"Ann Thorac Surg"},{"key":"1303_CR8","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1016\/j.jacr.2017.02.035","volume":"14","author":"JT Bencardino","year":"2017","unstructured":"Bencardino JT, Stone TJ, Roberts CC, et al. ACR Appropriateness Criteria\u00ae Stress (Fatigue\/Insufficiency) Fracture, Including Sacrum, Excluding Other Vertebrae. J Am Coll Radiol. 2017;14:293\u2013306. .","journal-title":"J Am Coll Radiol"},{"issue":"1","key":"1303_CR9","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1177\/03635465010290010201","volume":"29","author":"BP Boden","year":"2001","unstructured":"Boden BP, Osbahr DC, Jimenez C. Low-risk stress fractures. Am J Sports Med. 2001;29(1):100\u201311. .","journal-title":"Am J Sports Med"},{"issue":"6","key":"1303_CR10","doi-asserted-by":"publisher","first-page":"817","DOI":"10.23736\/S0021-9509.18.10462-9","volume":"59","author":"F Blokzijl","year":"2018","unstructured":"Blokzijl F, Dieperink W, Keus F, et al. Cardiac Rehabilitation for Patients Having Cardiac Surgery: A Systematic Review. J Cardiovasc Surg. 2018;59(6):817\u201329. .","journal-title":"J Cardiovasc Surg"}],"container-title":["Journal of Cardiothoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13019-020-01303-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13019-020-01303-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13019-020-01303-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,9,15]],"date-time":"2021-09-15T19:53:54Z","timestamp":1631735634000},"score":1,"resource":{"primary":{"URL":"https:\/\/cardiothoracicsurgery.biomedcentral.com\/articles\/10.1186\/s13019-020-01303-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,9,16]]},"references-count":10,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["1303"],"URL":"https:\/\/doi.org\/10.1186\/s13019-020-01303-y","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-42299\/v1","asserted-by":"object"},{"id-type":"doi","id":"10.21203\/rs.3.rs-42299\/v2","asserted-by":"object"}]},"ISSN":["1749-8090"],"issn-type":[{"value":"1749-8090","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,9,16]]},"assertion":[{"value":"13 July 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 September 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 September 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Not applicable.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"A written informed consent to publish the report was obtained from the patient before preparing the manuscript.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"Authors declare that they do not have any competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"258"}}