{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T13:28:38Z","timestamp":1740144518918,"version":"3.37.3"},"reference-count":7,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,12,1]],"date-time":"2021-12-01T00:00:00Z","timestamp":1638316800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,12,7]],"date-time":"2021-12-07T00:00:00Z","timestamp":1638835200000},"content-version":"vor","delay-in-days":6,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Cardiothorac Surg"],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Pseudoaneurysm of ascending aorta is a rare but serious complication of cardiovascular surgeries and it infrequently occurs in the normal prosthetic graft materials. We share our experience with an unusual case of\u00a0ascending aorta Dacron graft pseudoaneurysm caused by a fractured sternal wire.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Case presentation<\/jats:title>\n                <jats:p>A 34-year-old man, known case of Marfan syndrome, with history of two prior aortic surgeries for aneurysm of ascending aorta, arch and thoracoabdominal aorta, presented with hemoptysis. The hemoptysis originated from an aortobronchial fistula secondary to a huge ascending aorta Dacron graft pseudoaneurysm. The graft erosion and subsequent pseudoaneurysm was caused by a fractured sternal wire. Surgical repair of the pseudoaneurysm was performed successfully and a Gore-tex patch was placed behind the sternum over the graft to prevent further direct contact of the wire and the graft.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>Sternal wires can damage the adjacent vascular grafts and lead to fatal complications such as pseudoaneurysm formation. Thus, preventive measures such as using sternal bands and placing a covering layer between the sternal wires and aortic grafts are recommended in patients with dilated or replaced ascending aorta.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s13019-021-01737-y","type":"journal-article","created":{"date-parts":[[2021,12,7]],"date-time":"2021-12-07T11:02:33Z","timestamp":1638874953000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Ascending aorta graft pseudoaneurysm and aortobronchial fistula caused by a fractured sternal wire: a case report"],"prefix":"10.1186","volume":"16","author":[{"given":"Ahmad Ali","family":"Amirghofran","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9236-3057","authenticated-orcid":false,"given":"Elahe","family":"Nirooei","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohammad Ali","family":"Ostovan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,12,7]]},"reference":[{"issue":"3","key":"1737_CR1","first-page":"240","volume":"30","author":"C-L Kao","year":"2003","unstructured":"Kao C-L, Chang J-P. Aortic graft pseudoaneurysm secondary to fracture of sternal wires. Tex Heart Inst J. 2003;30(3):240\u20132.","journal-title":"Tex Heart Inst J"},{"issue":"3","key":"1737_CR2","first-page":"320","volume":"29","author":"L Lantsberg","year":"1988","unstructured":"Lantsberg L, Khodadadi J, Golcman L, Hertzanu Y, Szendro G. Unusual pseudoaneurysm of Dacron femoro-popliteal graft shaft. A case report. J Cardiovasc Surg (Torino). 1988;29(3):320\u20131.","journal-title":"J Cardiovasc Surg (Torino)"},{"issue":"5","key":"1737_CR3","doi-asserted-by":"publisher","first-page":"1682","DOI":"10.1016\/S0003-4975(00)02311-0","volume":"71","author":"AJ Schreffler","year":"2001","unstructured":"Schreffler AJ, Rumisek JD. Intravascular migration of fractured sternal wire presenting with hemoptysis. Ann Thorac Surg. 2001;71(5):1682\u20134.","journal-title":"Ann Thorac Surg"},{"issue":"5","key":"1737_CR4","doi-asserted-by":"publisher","first-page":"812","DOI":"10.1016\/j.ejcts.2003.11.043","volume":"25","author":"C-C Shih","year":"2004","unstructured":"Shih C-C, Shih C-M, Su Y-Y, Lin S-J. Potential risk of sternal wires. Eur J Cardiothorac Surg. 2004;25(5):812\u20138.","journal-title":"Eur J Cardiothorac Surg"},{"issue":"5","key":"1737_CR5","doi-asserted-by":"publisher","first-page":"453","DOI":"10.1177\/021849230701500522","volume":"15","author":"Z Al Halees","year":"2007","unstructured":"Al Halees Z, Abdoun F, Canver CC, Kharabsheh S. A right ventricle to aorta fistula caused by a fractured sternal wire. Asian Cardiovasc Thorac Ann. 2007;15(5):453\u20134.","journal-title":"Asian Cardiovasc Thorac Ann"},{"issue":"4","key":"1737_CR6","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1016\/j.jccase.2016.05.004","volume":"14","author":"OAA Ghani","year":"2016","unstructured":"Ghani OAA, Lau J, Kemble A. A runaway sternal wire: a rare case and outcome of sternal wire intravascular embolization. J Cardiol Cases. 2016;14(4):100\u20132.","journal-title":"J Cardiol Cases"},{"issue":"4","key":"1737_CR7","doi-asserted-by":"publisher","first-page":"1023","DOI":"10.1016\/0003-4975(94)90232-1","volume":"57","author":"SR Hazelrigg","year":"1994","unstructured":"Hazelrigg SR, Staller B. Migration of sternal wire into ascending aorta. Ann Thorac Surg. 1994;57(4):1023\u20134.","journal-title":"Ann Thorac Surg"}],"container-title":["Journal of Cardiothoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13019-021-01737-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13019-021-01737-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13019-021-01737-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,12,7]],"date-time":"2021-12-07T12:48:42Z","timestamp":1638881322000},"score":1,"resource":{"primary":{"URL":"https:\/\/cardiothoracicsurgery.biomedcentral.com\/articles\/10.1186\/s13019-021-01737-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,12]]},"references-count":7,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["1737"],"URL":"https:\/\/doi.org\/10.1186\/s13019-021-01737-y","relation":{},"ISSN":["1749-8090"],"issn-type":[{"type":"electronic","value":"1749-8090"}],"subject":[],"published":{"date-parts":[[2021,12]]},"assertion":[{"value":"15 June 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 November 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 December 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study followed the ethical standards of the Shiraz University of Medical Sciences research committee with the ethics committee code number of IR.sums.med.rec.1400.087.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Written consent was obtained from the patient.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"348"}}