{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,4]],"date-time":"2026-01-04T02:46:05Z","timestamp":1767494765534},"reference-count":15,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,10,4]],"date-time":"2022-10-04T00:00:00Z","timestamp":1664841600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,10,4]],"date-time":"2022-10-04T00:00:00Z","timestamp":1664841600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Cardiothorac Surg"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Soft coagulation using the VIO soft coagulation system is used to treat minor lung air leaks during pulmonary resection in Japan. We previously reported that it has a similar effect as the air leak treatment with fibrin glue. We evaluated the efficacy of soft coagulation using the VIO soft coagulation system for lung air leakage during pulmonary resection.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Intraoperative air leaks from the interlobar lung parenchyma were observed in 42 of the 283 patients who underwent video-assisted thoracoscopic surgery lobectomy between 2016 and 2018. We retrospectively reviewed these 42 patients who were treated using the VIO soft coagulation system for air leaks. We classified the air leaks in to grades using the Macchiarini scale score and evaluated the surgical outcomes of air leak treatment.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Air leaks from the interlobar lung parenchyma having Macchiarini scale scores 1, 2, and 3 occurred in 8, 17, and 17 patients, respectively. In all the 8 patients with score 1 air leaks (100%), the air leaks could be controlled using the VIO soft coagulation system alone, and none had delayed pneumothorax requiring intervention. Of the score 2 and 3 air leaks, 52.9% and 35.3% were controlled using the VIO soft coagulation system alone, respectively.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Macchiarini scale score 1 air leaks from the interlobar lung parenchyma could be well controlled using the VIO soft coagulation system. Therefore, soft coagulation with this system may be an alternative method for treating minor air leaks during pulmonary resection surgery.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s13019-022-01948-x","type":"journal-article","created":{"date-parts":[[2022,10,4]],"date-time":"2022-10-04T07:03:03Z","timestamp":1664866983000},"update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Clinical effect of soft coagulation for air leak treatment during pulmonary lobectomy"],"prefix":"10.1186","volume":"17","author":[{"given":"Yuki","family":"Takahashi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ryunosuke","family":"Maki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kodai","family":"Tsuruta","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Makoto","family":"Tada","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wataru","family":"Arai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuma","family":"Shindo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yasuyuki","family":"Nakamura","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masahiro","family":"Miyajima","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Atsushi","family":"Watanabe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,10,4]]},"reference":[{"key":"1948_CR1","doi-asserted-by":"publisher","first-page":"329","DOI":"10.1016\/j.ejcts.2004.11.005","volume":"27","author":"G Varela","year":"2005","unstructured":"Varela G, Jim\u00e9nez MF, Novoa N, Aranda JL. Estimating hospital costs attributable to prolonged air leak in pulmonary lobectomy. Eur J Cardiothorac Surg. 2005;27:329\u201333. https:\/\/doi.org\/10.1016\/j.ejcts.2004.11.005.","journal-title":"Eur J Cardiothorac Surg"},{"key":"1948_CR2","doi-asserted-by":"publisher","first-page":"661","DOI":"10.1093\/icvts\/ivs571","volume":"16","author":"PL Filosso","year":"2013","unstructured":"Filosso PL, Ruffini E, Sandri A, Lausi PO, Giobbe R, Oliaro A. Efficacy and safety of human fibrinogen-thrombin patch (TachoSil\u00ae) in the treatment of postoperative air leakage in patients submitted to redo surgery for lung malignancies: a randomized trial. Interact Cardiovasc Thorac Surg. 2013;16:661\u20136. https:\/\/doi.org\/10.1093\/icvts\/ivs571.","journal-title":"Interact Cardiovasc Thorac Surg"},{"key":"1948_CR3","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1016\/0003-4975(90)90371-c","volume":"49","author":"AG Fleisher","year":"1990","unstructured":"Fleisher AG, Evans KG, Nelems B, Finley RJ. Effect of routine fibrin glue use on the duration of air leaks after lobectomy. Ann Thorac Surg. 1990;49:133\u20134. https:\/\/doi.org\/10.1016\/0003-4975(90)90371-c.","journal-title":"Ann Thorac Surg"},{"key":"1948_CR4","doi-asserted-by":"publisher","first-page":"979","DOI":"10.1016\/s0003-4975(97)00820-5","volume":"64","author":"K Wong","year":"1997","unstructured":"Wong K, Goldstraw P. Effect of fibrin glue in the reduction of postthoracotomy alveolar air leak. Ann Thorac Surg. 1997;64:979\u201381. https:\/\/doi.org\/10.1016\/s0003-4975(97)00820-5.","journal-title":"Ann Thorac Surg"},{"key":"1948_CR5","doi-asserted-by":"publisher","first-page":"180","DOI":"10.1159\/000008637","volume":"31","author":"T Morikawa","year":"1999","unstructured":"Morikawa T, Katoh H. Improved techniques of applying fibrin glue in lung surgery. Eur Surg Res. 1999;31:180\u20136. https:\/\/doi.org\/10.1159\/000008637.","journal-title":"Eur Surg Res"},{"key":"1948_CR6","doi-asserted-by":"publisher","first-page":"1587","DOI":"10.1016\/s0003-4975(02)04994-9","volume":"75","author":"T Fabian","year":"2003","unstructured":"Fabian T, Federico JA, Ponn RB. Fibrin glue in pulmonary resection: a prospective, randomized, blinded study. Ann Thorac Surg. 2003;75:1587\u201392. https:\/\/doi.org\/10.1016\/s0003-4975(02)04994-9.","journal-title":"Ann Thorac Surg"},{"key":"1948_CR7","doi-asserted-by":"publisher","first-page":"1098","DOI":"10.1016\/s0003-4975(02)03415-x","volume":"73","author":"M Kawamura","year":"2002","unstructured":"Kawamura M, Sawafuji M, Watanabe M, Horinouchi H, Kobayashi K. Frequency of transmission of human parvovirus B19 infection by fibrin sealant used during thoracic surgery. Ann Thorac Surg. 2002;73:1098\u2013100. https:\/\/doi.org\/10.1016\/s0003-4975(02)03415-x.","journal-title":"Ann Thorac Surg"},{"key":"1948_CR8","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1007\/s11748-010-0709-5","volume":"59","author":"A Uchiyama","year":"2011","unstructured":"Uchiyama A, Miyoshi K, Nakamura K. VIO soft-coagulation system for major pulmonary resections: results in 68 patients with primary lung cancer. Gen Thorac Cardiovasc Surg. 2011;59:175\u20138. https:\/\/doi.org\/10.1007\/s11748-010-0709-5.","journal-title":"Gen Thorac Cardiovasc Surg"},{"key":"1948_CR9","doi-asserted-by":"publisher","first-page":"764","DOI":"10.1510\/icvts.2008.177923","volume":"7","author":"T Sakuragi","year":"2008","unstructured":"Sakuragi T, Okazaki Y, Mitsuoka M, Itoh T. Dramatic hemostasis of the transected pulmonary artery model using SOFT COAG electrosurgical output. Interact Cardiovasc Thorac Surg. 2008;7:764\u20136. https:\/\/doi.org\/10.1510\/icvts.2008.177923.","journal-title":"Interact Cardiovasc Thorac Surg"},{"key":"1948_CR10","doi-asserted-by":"publisher","first-page":"767","DOI":"10.1510\/icvts.2009.212696","volume":"9","author":"T Sakuragi","year":"2009","unstructured":"Sakuragi T, Ohma H, Ohteki H. Efficacy of SOFT COAG for intraoperative bleeding in thoracic surgery. Interact Cardiovasc Thorac Surg. 2009;9:767\u20138. https:\/\/doi.org\/10.1510\/icvts.2009.212696.","journal-title":"Interact Cardiovasc Thorac Surg"},{"key":"1948_CR11","first-page":"266","volume":"64","author":"S Yamamoto","year":"2011","unstructured":"Yamamoto S, Otani S, Mitsuda S, Endo T, Hasegawa T, Endo S. Electroablation for the treatment of spontaneous pneumothorax using SOFT COAG electrosurgical output system. Kyobu Geka. 2011;64:266\u201370.","journal-title":"Kyobu Geka"},{"key":"1948_CR12","doi-asserted-by":"publisher","first-page":"765","DOI":"10.2995\/jacsurg.29.765","volume":"29","author":"D Taniguchi","year":"2015","unstructured":"Taniguchi D, Kamohara R, Nakamura A. Electroablation using the SOFT COAG electrosurgical output system for the treatment of secondary spontaneous pneumothorax in a patient with non-tuberculous mycobacteriosis. Jpn J Chest Surg. 2015;29:765\u20139. https:\/\/doi.org\/10.2995\/jacsurg.29.765.","journal-title":"Jpn J Chest Surg"},{"key":"1948_CR13","doi-asserted-by":"publisher","first-page":"1521","DOI":"10.1007\/s00595-021-02251-3","volume":"51","author":"Y Takahashi","year":"2021","unstructured":"Takahashi Y, Saito A, Sakuma Y, Tada M, Maki R, Takahashi M, et al. Treatment of air leakage using the VIO soft coagulation system: a mouse pulmonary air leak model. Surg Today. 2021;51:1521\u20139. https:\/\/doi.org\/10.1007\/s00595-021-02251-3.","journal-title":"Surg Today"},{"key":"1948_CR14","doi-asserted-by":"publisher","first-page":"751","DOI":"10.1016\/S0022-5223(99)70296-5","volume":"117","author":"P Macchiarini","year":"1999","unstructured":"Macchiarini P, Wain J, Almy S, Dartevelle P. Experimental and clinical evaluation of a new synthetic, absorbable sealant to reduce air leaks in thoracic operations. J Thorac Cardiovasc Surg. 1999;117:751\u20138. https:\/\/doi.org\/10.1016\/S0022-5223(99)70296-5.","journal-title":"J Thorac Cardiovasc Surg"},{"key":"1948_CR15","doi-asserted-by":"publisher","first-page":"383","DOI":"10.1016\/j.jtcvs.2008.04.014","volume":"136","author":"A Droghetti","year":"2008","unstructured":"Droghetti A, Schiavini A, Muriana P, Folloni A, Picarone M, Bonadiman C, et al. A prospective randomized trial comparing completion technique of fissures for lobectomy: stapler versus precision dissection and sealant. J Thorac Cardiovasc Surg. 2008;136:383\u201391.https:\/\/doi.org\/10.1016\/j.jtcvs.2008.04.014.","journal-title":"J Thorac Cardiovasc Surg"}],"container-title":["Journal of Cardiothoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13019-022-01948-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13019-022-01948-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13019-022-01948-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,10,4]],"date-time":"2022-10-04T07:11:58Z","timestamp":1664867518000},"score":1,"resource":{"primary":{"URL":"https:\/\/cardiothoracicsurgery.biomedcentral.com\/articles\/10.1186\/s13019-022-01948-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,10,4]]},"references-count":15,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["1948"],"URL":"https:\/\/doi.org\/10.1186\/s13019-022-01948-x","relation":{},"ISSN":["1749-8090"],"issn-type":[{"value":"1749-8090","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,10,4]]},"assertion":[{"value":"24 January 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 August 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 October 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This retrospective study was approved by our institutional review board (Sapporo Medical University Institutional Review Board clinical registration number: 322-310).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"The requirement to obtain informed consent was waived.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"253"}}