{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,17]],"date-time":"2026-10-17T16:10:14Z","timestamp":1792253414471,"version":"4.4.0"},"reference-count":8,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,10,4]],"date-time":"2022-10-04T00:00:00Z","timestamp":1664841600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,10,4]],"date-time":"2022-10-04T00:00:00Z","timestamp":1664841600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Cardiothorac Surg"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Perigraft seroma is a persistent and sterile fluid confined within a fibrous pseudomembrane surrounding a graft that develops after graft replacement. Development of perigraft seroma is an uncommon complication that occurs after the surgical repair of the thoracic aorta using woven polyester grafts. mechanism underlying perigraft seroma formation remains unclear.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Case presentation<\/jats:title>\n                <jats:p>Herein, we describe the case of 77-year-old man who underwent repeat sternotomy for the treatment of large perigraft seroma 1\u00a0year after ascending aorta replacement for acute type A dissection. After removing a cloudy yellow fluid, we covered the prosthetic graft with fibrin glue and wrapped it with a new graft. Bacterial culture and laboratory examination of the fluid confirmed the final diagnosis of perigraft seroma, and there was no evidence of recurrence. The area in which fluid accumulated around the graft shrunk 1\u00a0year after surgery.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>The cause of a expanding perigraft after repair of the thoracic aorta remains unknown. Physicians should be aware that chronic expanding mediastinal seroma with Dacron grafts is one of the rare postoperative complications of thoracic aortic surgery. Applying fibrin glue to the graft surface might effectively prevent the recurrence of perigraft seroma.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s13019-022-02018-y","type":"journal-article","created":{"date-parts":[[2022,10,4]],"date-time":"2022-10-04T07:03:03Z","timestamp":1664866983000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Expanding perigraft seroma after ascending aorta replacement"],"prefix":"10.1186","volume":"17","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1823-5962","authenticated-orcid":false,"given":"Shinji","family":"Kanemitsu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shunsuke","family":"Sakamoto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Satoshi","family":"Teranishi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Toru","family":"Mizumoto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,10,4]]},"reference":[{"key":"2018_CR1","doi-asserted-by":"publisher","first-page":"1273","DOI":"10.2214\/AJR.05.1654","volume":"188","author":"B Sundaram","year":"2007","unstructured":"Sundaram B, Quint LE, Patel S, Patel HJ, Deeb GM. CT appearance of thoracic aortic graft complications. AJR Am J Roentgenol. 2007;188:1273\u20137.","journal-title":"AJR Am J Roentgenol"},{"key":"2018_CR2","doi-asserted-by":"publisher","first-page":"44","DOI":"10.3400\/avd.cr08010","volume":"2","author":"Y Kondo","year":"2009","unstructured":"Kondo Y, Muto A, Dardik A, Nishibe M, Nishibe T. Perigraft seroma after surgical aortoiliac aneurysm repair with knitted polyester grafts: report of two cases. Ann Vasc Dis. 2009;2:44\u20136.","journal-title":"Ann Vasc Dis"},{"key":"2018_CR3","doi-asserted-by":"publisher","first-page":"637","DOI":"10.1016\/j.jvs.2011.03.258","volume":"54","author":"AK Kadakol","year":"2011","unstructured":"Kadakol AK, Nypaver TJ, Lin JC, Weaver MR, Karam JL, Reddy DJ, Haddad GK, Shepard AD. Frequency, risk factors, and management of perigraft seroma after open abdominal aortic aneurysm repair. J Vasc Surg. 2011;54:637\u201343.","journal-title":"J Vasc Surg"},{"key":"2018_CR4","doi-asserted-by":"publisher","first-page":"1010","DOI":"10.1111\/j.1525-1594.1993.tb03183.x","volume":"17","author":"K Yamamoto","year":"1993","unstructured":"Yamamoto K, Noishiki Y, Mo M, Kondo J, Matsumoto A. Unusual inflammatory responses around a collagen-impregnated vascular prosthesis. Artif Organs. 1993;17:1010\u20136.","journal-title":"Artif Organs"},{"key":"2018_CR5","first-page":"194","volume":"97","author":"RM Blumenberg","year":"1985","unstructured":"Blumenberg RM, Gelfand ML, Dale WA. Perigraft seromas complicating arterial grafts. Surgery. 1985;97:194\u2013204.","journal-title":"Surgery"},{"key":"2018_CR6","doi-asserted-by":"publisher","first-page":"813","DOI":"10.1583\/06-2037.1","volume":"14","author":"H Ohtake","year":"2007","unstructured":"Ohtake H, Kimura K, Soga S, Sanada J, Matsui O, Watanabe G. Stent-graft deployment to treat a perigraft seroma formed after descending thoracic aortic surgery. J Endovasc Ther. 2007;14:813\u20135.","journal-title":"J Endovasc Ther"},{"key":"2018_CR7","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1097\/SAP.0000000000002408","volume":"86","author":"N Chow","year":"2021","unstructured":"Chow N, Miears H, Cox C, MacKay B. Fibrin glue and its alternatives in peripheral nerve repair. Ann Plast Surg. 2021;86:103\u20138.","journal-title":"Ann Plast Surg"},{"key":"2018_CR8","doi-asserted-by":"publisher","first-page":"174","DOI":"10.1007\/s10047-010-0504-1","volume":"13","author":"M Hisagi","year":"2010","unstructured":"Hisagi M, Nishimura T, Ono M, Gojo S, Nawata K, Kyo S. New pre-clotting method for fibrin glue in a non-sealed graft used in an LVAD: the KYO method. J Artif Organs. 2010;13:174\u20137.","journal-title":"J Artif Organs"}],"container-title":["Journal of Cardiothoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13019-022-02018-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13019-022-02018-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13019-022-02018-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,10,4]],"date-time":"2022-10-04T07:11:56Z","timestamp":1664867516000},"score":1,"resource":{"primary":{"URL":"https:\/\/cardiothoracicsurgery.biomedcentral.com\/articles\/10.1186\/s13019-022-02018-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,10,4]]},"references-count":8,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["2018"],"URL":"https:\/\/doi.org\/10.1186\/s13019-022-02018-y","relation":{},"ISSN":["1749-8090"],"issn-type":[{"value":"1749-8090","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,10,4]]},"assertion":[{"value":"16 September 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 September 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 October 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study protocol was approved by the institutional review board of Anjo Kosei Hospital (approval date, April 26, 2021; Approval Number, C21-002), and informed consent was obtained.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"The patient has provided permission to publish these features of his case, and the identity of the patient has been protected.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"None of authors have a conflict of interest.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"252"}}