{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T16:47:41Z","timestamp":1790182061099,"version":"4.1.0"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,4,10]],"date-time":"2023-04-10T00:00:00Z","timestamp":1681084800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,4,10]],"date-time":"2023-04-10T00:00:00Z","timestamp":1681084800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Cardiothorac Surg"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Lung biopsy (LB) procedures performed with computed tomography (CT guidance can enable the reliable diagnosis of lung lesions. These diagnostic efforts can be further expedited through a rapid on-site evaluation (ROSE) approach, allowing for the rapid assessment of collected tissue samples to gauge the adequacy of these samples, their features, and associated cytomorphological characteristics. The present analysis was developed to examine the safety and efficacy of CT-guided LB with ROSE as a means of diagnosing lung lesions.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Studies published as of July 31, 2022 in the PubMed, Embase, and Wanfang databases were identified for this meta-analysis. Diagnostic accuracy was the primary endpoint, while secondary endpoints included the operative duration, the number of punctures, and rates of lung hemorrhage, pneumothorax, and secondary LB.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>This meta-analysis included 6 total studies. Relative to CT alone, CT with ROSE was associated with a significant increase in diagnostic accuracy (<jats:italic>P<\/jats:italic>\u2009&lt;\u20090.00001). In contrast, there were no significant differences between these two groups with respect to the operative duration (<jats:italic>P<\/jats:italic>\u2009=\u20090.86), the number of punctures (<jats:italic>P<\/jats:italic>\u2009=\u20090.60), or the rates of pneumothorax (<jats:italic>P<\/jats:italic>\u2009=\u20090.82) or lung hemorrhage (<jats:italic>P<\/jats:italic>\u2009=\u20090.81). Pooled secondary LB rates were significantly lower for patients that underwent CT with ROSE relative to patients in the CT only group (<jats:italic>P<\/jats:italic>\u2009=\u20090.0008). Significant heterogeneity was detected for the operative duration (<jats:italic>I<\/jats:italic><jats:sup>2<\/jats:sup>\u2009=\u200994%) and number of punctures (<jats:italic>I<\/jats:italic><jats:sup>2<\/jats:sup>\u2009=\u200998%) endpoints, while no publication bias was detected for any study endpoints.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>These results suggest that ROSE may contribute to significant improvements in the diagnostic accuracy of CT-guided LB without contributing to higher rates of complications.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s13019-023-02212-6","type":"journal-article","created":{"date-parts":[[2023,4,10]],"date-time":"2023-04-10T12:03:04Z","timestamp":1681128184000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":18,"title":["Computed tomography-guided lung biopsy with rapid on-site evaluation for diagnosis of lung lesions: a meta-analysis"],"prefix":"10.1186","volume":"18","author":[{"given":"Di","family":"Wu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yue-Yue","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tao","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ya-Yong","family":"Huang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ping","family":"Xia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,4,10]]},"reference":[{"key":"2212_CR1","doi-asserted-by":"publisher","DOI":"10.1016\/j.tvir.2021.100770","volume":"24","author":"PP Bourgouin","year":"2021","unstructured":"Bourgouin PP, Rodriguez KJ, Fintelmann FJ. Image-guided percutaneous lung needle biopsy: how we do it. Tech Vasc Interv Radiol. 2021;24: 100770.","journal-title":"Tech Vasc Interv Radiol"},{"key":"2212_CR2","doi-asserted-by":"publisher","first-page":"727","DOI":"10.1016\/j.diii.2020.07.007","volume":"101","author":"J Brioulet","year":"2020","unstructured":"Brioulet J, David A, Sagan C, Cellerin L, Frampas E, Morla O. Percutaneous CT-guided lung biopsy for the diagnosis of persistent pulmonary consolidation. Diagn Interv Imaging. 2020;101:727\u201332.","journal-title":"Diagn Interv Imaging"},{"key":"2212_CR3","doi-asserted-by":"publisher","first-page":"449","DOI":"10.4067\/S0034-98872013000400005","volume":"141","author":"C Besa","year":"2013","unstructured":"Besa C, Huele A, B\u00e4chler P, Cruz F. Percutaneous CT-guided cutting needle biopsy of pulmonary lesions: retrospective analysis of 153 procedures. Rev Med Chil. 2013;141:449\u201356.","journal-title":"Rev Med Chil"},{"key":"2212_CR4","doi-asserted-by":"publisher","first-page":"1584","DOI":"10.1007\/s00330-019-06464-6","volume":"30","author":"YF Fu","year":"2020","unstructured":"Fu YF, Li GC, Xu QS, Shi YB, Wang C, Wang T. Computed tomography-guided lung biopsy: a randomized controlled trial of low-dose versus standard-dose protocol. Eur Radiol. 2020;30:1584\u201392.","journal-title":"Eur Radiol"},{"key":"2212_CR5","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1111\/crj.13275","volume":"15","author":"YF Fu","year":"2021","unstructured":"Fu YF, Zhang JH, Wang T, Shi YB. Endobronchial ultrasound-guided versus computed tomography-guided biopsy for peripheral pulmonary lesions: a meta-analysis. Clin Respir J. 2021;15:3\u201310.","journal-title":"Clin Respir J"},{"key":"2212_CR6","doi-asserted-by":"publisher","DOI":"10.1097\/MD.0000000000029016","volume":"101","author":"Y Li","year":"2022","unstructured":"Li Y, Yang F, Huang YY, Cao W. Comparison between computed tomography-guided core and fine needle lung biopsy: a meta-analysis. Medicine (Baltimore). 2022;101: e29016.","journal-title":"Medicine (Baltimore)"},{"key":"2212_CR7","doi-asserted-by":"publisher","first-page":"571","DOI":"10.1097\/RCT.0000000000001044","volume":"44","author":"YF Fu","year":"2020","unstructured":"Fu YF, Li GC, Cao W, Wang T, Shi YB. Computed tomography fluoroscopy-guided versus conventional computed tomography-guided lung biopsy: a systematic review and meta-analysis. J Comput Assist Tomogr. 2020;44:571\u20137.","journal-title":"J Comput Assist Tomogr"},{"key":"2212_CR8","doi-asserted-by":"publisher","first-page":"581","DOI":"10.1097\/01.RVI.0000071087.76348.C7","volume":"14","author":"KM Yeow","year":"2003","unstructured":"Yeow KM, Tsay PK, Cheung YC, Lui KW, Pan KT, Chou AS. Factors affecting diagnostic accuracy of CT-guided coaxial cutting needle lung biopsy: retrospective analysis of 631 procedures. J Vasc Interv Radiol. 2003;14:581\u20138.","journal-title":"J Vasc Interv Radiol"},{"key":"2212_CR9","doi-asserted-by":"publisher","first-page":"1612","DOI":"10.1378\/chest.09-0370","volume":"136","author":"T Hiraki","year":"2009","unstructured":"Hiraki T, Mimura H, Gobara H, Iguchi T, Fujiwara H, Sakurai J, et al. CT fluoroscopy-guided biopsy of 1000 pulmonary lesions performed with 20-gauge coaxial cutting needles: diagnostic yield and risk factors for diagnostic failure. Chest. 2009;136:1612\u20137.","journal-title":"Chest"},{"key":"2212_CR10","doi-asserted-by":"publisher","first-page":"479","DOI":"10.21037\/tcr-20-3294","volume":"10","author":"Z Huang","year":"2021","unstructured":"Huang Z, Zhuang D, Feng A, Ye L, Hong L. Real-time and accuracy of rapid on-site cytological evaluation of lung cancer. Transl Cancer Res. 2021;10:479\u201386.","journal-title":"Transl Cancer Res"},{"key":"2212_CR11","doi-asserted-by":"publisher","first-page":"1684","DOI":"10.1016\/j.jfma.2020.01.001","volume":"119","author":"CK Lin","year":"2020","unstructured":"Lin CK, Jan IS, Yu KL, Chang LY, Fan HJ, Wen YF, et al. Rapid on-site cytologic evaluation by pulmonologist improved diagnostic accuracy of endobronchial ultrasound-guided transbronchial biopsy. J Formos Med Assoc. 2020;119:1684\u201392.","journal-title":"J Formos Med Assoc"},{"key":"2212_CR12","first-page":"S418","volume":"7","author":"CH Chen","year":"2015","unstructured":"Chen CH, Cheng WC, Wu BR, Chen CY, Chen WC, Hsia TC, et al. Improved diagnostic yield of bronchoscopy in peripheral pulmonary lesions: combination of radial probe endobronchial ultrasound and rapid on-site evaluation. J Thorac Dis. 2015;7:S418\u201325.","journal-title":"J Thorac Dis"},{"key":"2212_CR13","doi-asserted-by":"publisher","first-page":"253","DOI":"10.5858\/arpa.2017-0114-SA","volume":"142","author":"D Jain","year":"2018","unstructured":"Jain D, Allen TC, Aisner DL, Beasley MB, Cagle PT, Capelozzi VL, et al. Rapid on-site evaluation of endobronchial ultrasound-guided transbronchial needle aspirations for the diagnosis of lung cancer: a perspective from members of the pulmonary pathology society. Arch Pathol Lab Med. 2018;142:253\u201362.","journal-title":"Arch Pathol Lab Med"},{"key":"2212_CR14","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1097\/LBR.0000000000000339","volume":"24","author":"K Madan","year":"2017","unstructured":"Madan K, Dhungana A, Mohan A, Hadda V, Jain D, Arava S, et al. Conventional transbronchial needle aspiration versus endobronchial ultrasound-guided transbronchial needle aspiration, with or without rapid on-site evaluation, for the diagnosis of sarcoidosis: a randomized controlled trial. J Bronchology Interv Pulmonol. 2017;24:48\u201358.","journal-title":"J Bronchology Interv Pulmonol"},{"key":"2212_CR15","doi-asserted-by":"publisher","first-page":"929","DOI":"10.1016\/j.chest.2017.11.004","volume":"153","author":"IS Sehgal","year":"2018","unstructured":"Sehgal IS, Dhooria S, Aggarwal AN, Agarwal R. Impact of rapid on-site cytological evaluation (ROSE) on the diagnostic yield of transbronchial needle aspiration during mediastinal lymph node sampling: systematic review and meta-analysis. Chest. 2018;153:929\u201338.","journal-title":"Chest"},{"key":"2212_CR16","first-page":"2885","volume":"49","author":"Y Huang","year":"2020","unstructured":"Huang Y, Xia L, Tang C, Yi S, Yang Z. Application research of cell rapid on-site evaluation in CT-guided percutaneous lung biopsy. Chong Qing Yi Xue. 2020;49:2885\u20138.","journal-title":"Chong Qing Yi Xue"},{"key":"2212_CR17","first-page":"18","volume":"17","author":"Y Li","year":"2020","unstructured":"Li Y, Li K, Wang X, Shan C, Li C. Rapid on-site evaluation in CT-guided percutaneous biopsy of peripheral pulmonary nodules. Chin J Interv Imaging. 2020;17:18\u201321.","journal-title":"Chin J Interv Imaging"},{"key":"2212_CR18","doi-asserted-by":"publisher","first-page":"153303382211187","DOI":"10.1177\/15330338221118718","volume":"21","author":"W Liu","year":"2022","unstructured":"Liu W, Xu C, Li L, Yuan Q, Wang W, Zou J. The value of computed tomography-guided percutaneous lung biopsy combined with rapid on-site evaluation in diagnosis of peripheral pulmonary nodules. Technol Cancer Res Treat. 2022;21:15330338221118718.","journal-title":"Technol Cancer Res Treat"},{"key":"2212_CR19","doi-asserted-by":"publisher","first-page":"9842768","DOI":"10.1155\/2020\/9842768","volume":"2020","author":"TF Peng","year":"2020","unstructured":"Peng TF, Ren T, Wang HS, Feng ZX, Wang MF. Diagnostic value of rapid on-site evaluation for CT-guided percutaneous fine needle aspiration in the diagnosis of pulmonary occupying lesions. Biomed Res Int. 2020;2020:9842768.","journal-title":"Biomed Res Int"},{"key":"2212_CR20","first-page":"94","volume":"49","author":"C Wang","year":"2021","unstructured":"Wang C, Wang Y, Yang Q. The application of rapid on-site cytological evaluation for percutaneous lung biopsy. Tianjin Med J. 2021;49:94\u20137.","journal-title":"Tianjin Med J"},{"key":"2212_CR21","doi-asserted-by":"publisher","first-page":"439","DOI":"10.1111\/cyt.13123","volume":"33","author":"R Yiminniyaze","year":"2022","unstructured":"Yiminniyaze R, Zhang X, Zhang Y, Chen K, Li C, Zhu N, et al. Diagnostic efficiency and safety of rapid on-site evaluation combined with CT-guided transthoracic core needle biopsy in suspected lung cancer patients. Cytopathology. 2022;33:439\u201344.","journal-title":"Cytopathology"},{"key":"2212_CR22","first-page":"99","volume":"18","author":"L Zhang","year":"2021","unstructured":"Zhang L, Tao L, Wang X, Li X, Wang Y, Zhang Y. Application of C-ROSE combined with 4D navigation-guided CT localization in percutaneous puncture lung biopsy. China Med Equip. 2021;18:99\u2013102.","journal-title":"China Med Equip"},{"key":"2212_CR23","doi-asserted-by":"publisher","first-page":"277","DOI":"10.3904\/kjim.2016.195","volume":"33","author":"YH Lee","year":"2018","unstructured":"Lee YH. An overview of meta-analysis for clinicians. Korean J Intern Med. 2018;33:277\u201383.","journal-title":"Korean J Intern Med"},{"key":"2212_CR24","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/2046-4053-4-1","volume":"4","author":"D Moher","year":"2015","unstructured":"Moher D, Shamseer L, Clarke M, Ghersi D, Liberati A, Petticrew M, et al. Preferred reporting items for systematic review and meta-analysis protocols (PRISMA-P) 2015 statement. Syst Rev. 2015;4:1.","journal-title":"Syst Rev"},{"key":"2212_CR25","doi-asserted-by":"publisher","first-page":"603","DOI":"10.1007\/s10654-010-9491-z","volume":"25","author":"A Stang","year":"2010","unstructured":"Stang A. Critical evaluation of the Newcastle-Ottawa scale for the assessment of the quality of nonrandomized studies in meta-analyses. Eur J Epidemiol. 2010;25:603\u20135.","journal-title":"Eur J Epidemiol"},{"key":"2212_CR26","first-page":"355","volume":"16","author":"YY Huang","year":"2021","unstructured":"Huang YY, Cheng H, Li GC. Computed tomography-guided core needle biopsy for lung nodules: low-dose versus standard-dose protocols. Wideochir Inne Tech Maloinwazyjne. 2021;16:355\u201361.","journal-title":"Wideochir Inne Tech Maloinwazyjne"},{"key":"2212_CR27","doi-asserted-by":"publisher","first-page":"1319","DOI":"10.1016\/j.jvir.2021.06.022","volume":"32","author":"AM Zlevor","year":"2021","unstructured":"Zlevor AM, Mauch SC, Knott EA, Pickhardt PJ, Mankowski Gettle L, Mao L, et al. Percutaneous lung biopsy with pleural and parenchymal blood patching: results and complications from 1112 core biopsies. J Vasc Interv Radiol. 2021;32:1319\u201327.","journal-title":"J Vasc Interv Radiol"},{"key":"2212_CR28","doi-asserted-by":"publisher","DOI":"10.1097\/MD.0000000000008703","volume":"96","author":"GC Li","year":"2017","unstructured":"Li GC, Fu YF, Cao W, Shi YB, Wang T. Computed tomography-guided percutaneous cutting needle biopsy for small (\u2264 20 mm) lung nodules. Medicine (Baltimore). 2017;96: e8703.","journal-title":"Medicine (Baltimore)"}],"container-title":["Journal of Cardiothoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13019-023-02212-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13019-023-02212-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13019-023-02212-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,4,10]],"date-time":"2023-04-10T12:09:16Z","timestamp":1681128556000},"score":1,"resource":{"primary":{"URL":"https:\/\/cardiothoracicsurgery.biomedcentral.com\/articles\/10.1186\/s13019-023-02212-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,4,10]]},"references-count":28,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["2212"],"URL":"https:\/\/doi.org\/10.1186\/s13019-023-02212-6","relation":{},"ISSN":["1749-8090"],"issn-type":[{"value":"1749-8090","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,4,10]]},"assertion":[{"value":"1 September 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 April 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 April 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This is a meta-analysis and ethics approval and consent to participate are not required.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"This is a meta-analysis and consent for publication is not required.Availability of data and materials: The data that support the findings of this study are available from the corresponding author upon reasonable request.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declared that they have no Competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"122"}}