{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,1,7]],"date-time":"2024-01-07T00:16:10Z","timestamp":1704586570386},"reference-count":1,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,1,6]],"date-time":"2024-01-06T00:00:00Z","timestamp":1704499200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,1,6]],"date-time":"2024-01-06T00:00:00Z","timestamp":1704499200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Cardiothorac Surg"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Anastomotic aneurysms present as a life-threatening emergency after descending aortic replacement for aortic dissection. Thoracic endovascular aneurysm repair (TEVAR) has been performed since the early 2000s for complicated cases in which re-thoracotomy cannot be adopted. We report the case of a 57-year-old male patient, during a 5-year follow-up after descending aortic replacement for aortic dissection, developed aneurysm expansion around the false lumen on the peripheral side of the artificial graft. Considering the risk and the patient\u2019s desires, we opted to perform TEVAR with different calibers into the true and false lumens \u201cmodified kissing stents technique\u201d. His postoperative course was uneventful without any complications. This case highlights the utility of the modified kissing stents technique for anastomotic aneurysms after descending aortic replacement for aortic dissection using stent grafts with different calibers into the true and false lumens.<\/jats:p>","DOI":"10.1186\/s13019-023-02477-x","type":"journal-article","created":{"date-parts":[[2024,1,6]],"date-time":"2024-01-06T17:01:49Z","timestamp":1704560509000},"update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Placement of stent grafts with different calibers into the true and false lumens of anastomotic aneurysms after descending aortic replacement for aortic dissection"],"prefix":"10.1186","volume":"19","author":[{"given":"Hiroo","family":"Uehara","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masateru","family":"Uchiyama","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomohiro","family":"Imazuru","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2024,1,6]]},"reference":[{"key":"2477_CR1","doi-asserted-by":"publisher","first-page":"995","DOI":"10.1016\/j.jtcvs.2015.07.004","volume":"150","author":"A Yoshitake","year":"2015","unstructured":"Yoshitake A, Hachiya T, Hayashi K, Shimizu H. The kissing stents technique for a patient with chronic type B aortic dissection. J Thorac Cardiovasc Surg. 2015;150:995\u20137.","journal-title":"J Thorac Cardiovasc Surg"}],"container-title":["Journal of Cardiothoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13019-023-02477-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13019-023-02477-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13019-023-02477-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,1,6]],"date-time":"2024-01-06T17:03:40Z","timestamp":1704560620000},"score":1,"resource":{"primary":{"URL":"https:\/\/cardiothoracicsurgery.biomedcentral.com\/articles\/10.1186\/s13019-023-02477-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,6]]},"references-count":1,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["2477"],"URL":"https:\/\/doi.org\/10.1186\/s13019-023-02477-x","relation":{},"ISSN":["1749-8090"],"issn-type":[{"value":"1749-8090","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,1,6]]},"assertion":[{"value":"15 October 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 December 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 January 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Ethics approval and consent for this study have been obtained from participants.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"All subjects enrolled in this research have given their informed consent which alongside the described protocol.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"All authors have no conflict of interest to disclosure as described by <i>Journal of Cardiothoracic Surgery<\/i>.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"9"}}