{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,27]],"date-time":"2026-02-27T04:25:37Z","timestamp":1772166337734,"version":"3.50.1"},"reference-count":14,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,2,6]],"date-time":"2024-02-06T00:00:00Z","timestamp":1707177600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,2,6]],"date-time":"2024-02-06T00:00:00Z","timestamp":1707177600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Shanxi Provincial Natural Science Basic Research Program","award":["20210302124094"],"award-info":[{"award-number":["20210302124094"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Cardiothorac Surg"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Electrical storm (ES) is a clinical emergency characterized by multiple malignant ventricular arrhythmias or ICD discharges within 24\u00a0h, requiring early rational management.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Case presentation<\/jats:title>\n                    <jats:p>We report a 55-year-old man who underwent aortic valve replacement experienced recurrent ventricular tachycardia\/ventricular fibrillation. A temporary permanent pacemaker with the EnSite system was implanted, and significant inhibition of the electrical storm, attributed to the atrial overdrive pacing, ensued.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>In emergency regarding an electrical storm, the bedside temporary permanent pacemaker implantation with the EnSite system is concluded to be feasible and safe.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s13019-024-02579-0","type":"journal-article","created":{"date-parts":[[2024,2,6]],"date-time":"2024-02-06T03:02:37Z","timestamp":1707188557000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Bedside zero-fluoroscopy temporary permanent pacemaker implantation in the electrical storm treatment under the guidance of EnSite 3D system: a case report"],"prefix":"10.1186","volume":"19","author":[{"given":"Lei","family":"Wang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pengfei","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jun","family":"li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jicheng","family":"Xi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhibiao","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fang","family":"Yan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yanan","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Haixiong","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Huiyuan","family":"Han","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2024,2,6]]},"reference":[{"issue":"4","key":"2579_CR1","doi-asserted-by":"publisher","first-page":"439","DOI":"10.1016\/j.cjca.2021.12.015","volume":"38","author":"I Elsokkari","year":"2022","unstructured":"Elsokkari I, Tsuji Y, Sapp JL, Nattel S. Recent insights into mechanisms and clinical approaches to Electrical Storm. Can J Cardiol. 2022;38(4):439\u201353.","journal-title":"Can J Cardiol"},{"issue":"5","key":"2579_CR2","doi-asserted-by":"publisher","first-page":"613","DOI":"10.1253\/circj.69.613","volume":"69","author":"S Kurisu","year":"2005","unstructured":"Kurisu S, Inoue I, Kawagoe T, Ishihara M, Shimatani Y, Mitsuba N, Hata T, Nakama Y, Kisaka T, Kijima Y. Temporary overdriving pacing as an adjunct to antiarrhythmic drug therapy for electrical storm in acute myocardial infarction. Circ J. 2005;69(5):613\u20136.","journal-title":"Circ J"},{"issue":"8","key":"2579_CR3","doi-asserted-by":"publisher","first-page":"875","DOI":"10.1111\/j.1540-8159.2006.00454.x","volume":"29","author":"MU Braun","year":"2006","unstructured":"Braun MU, Rauwolf T, Bock M, Kappert U, Boscheri A, Schnabel A, Strasser RH. Percutaneous lead implantation connected to an external device in stimulation-dependent patients with systemic infection\u2013a prospective and controlled study. Pacing Clin Electrophysiol. 2006;29(8):875\u20139.","journal-title":"Pacing Clin Electrophysiol"},{"issue":"3","key":"2579_CR4","doi-asserted-by":"publisher","first-page":"677","DOI":"10.1536\/ihj.20-487","volume":"62","author":"T Hasegawa","year":"2021","unstructured":"Hasegawa T, Tachibana T, Kimura H, Yazaki Y. Successful treatment of refractory cardiogenic shock and electrical storm using the IMPELLA 5.0 with Atrial Overdrive Pacing, in a patient with severe peripheral arterial disease. Int Heart J. 2021;62(3):677\u201381.","journal-title":"Int Heart J"},{"issue":"5","key":"2579_CR5","doi-asserted-by":"publisher","first-page":"3652","DOI":"10.19102\/icrm.2019.100506","volume":"10","author":"K Suarez","year":"2019","unstructured":"Suarez K, Banchs JE. A review of Temporary Permanent pacemakers and a comparison with Conventional Temporary pacemakers. J Innov Card Rhythm Manag. 2019;10(5):3652\u201361.","journal-title":"J Innov Card Rhythm Manag"},{"key":"2579_CR6","doi-asserted-by":"crossref","unstructured":"de Cock CC, Van Campen CM, In\u2019t Veld JA, Visser CA. Utility and safety of prolonged temporary transvenous pacing using an active-fixation lead: comparison with a conventional lead. Pacing Clin Electrophysiol. 2003;26(5):1245\u20138.","DOI":"10.1046\/j.1460-9592.2003.t01-1-00175.x"},{"key":"2579_CR7","doi-asserted-by":"crossref","unstructured":"Zhou X, Ze F, Li D, Li X, Wang B. Outcomes of temporary pacing using active fixation leads and externalized permanent pacemakers in patients with cardiovascular implantable electronic device infection and pacemaker dependency. Cardiovasc Electrophysiol. 2021;32(11):3051\u20136.","DOI":"10.1111\/jce.15236"},{"key":"2579_CR8","doi-asserted-by":"crossref","unstructured":"Zweiker D, Melillo F, D\u2019Angelo G, Radinovic A, Marzi A, Cianfanelli L, Altizio S, Limite LR, Paglino G, Frontera A, Nakajima K, Brugliera L, Malatino L, Della Bella P, Mazzone P. Working on the dirty side-the ipsilateral subclavian access for temporary pacing after lead extraction. J Arrhythm. 2022;38(2):192\u20138.","DOI":"10.1002\/joa3.12677"},{"key":"2579_CR9","doi-asserted-by":"crossref","unstructured":"Hu Y, Ding L, Hua W, Gu M, Cai M, Chen X, Fan X, Niu H, Zhang S. Comparison between his-bundle pacing guided by Ensite NavX system and conventional fluoroscopy. J Interv Card Electrophysiol. 2020;57(1):107\u201314.","DOI":"10.1007\/s10840-019-00660-6"},{"issue":"2","key":"2579_CR10","doi-asserted-by":"publisher","first-page":"122","DOI":"10.1111\/pace.13248","volume":"41","author":"P Guo","year":"2018","unstructured":"Guo P, Qiu J, Wang Y, Chen G, Proietti R, Fadhle AS, Zhao C, Wen Wang D. Zero-fluoroscopy permanent pacemaker implantation using Ensite NavX system: clinical viability or fanciful technique? Pacing Clin Electrophysiol. 2018;41(2):122\u20137.","journal-title":"Pacing Clin Electrophysiol"},{"issue":"7","key":"2579_CR11","doi-asserted-by":"publisher","first-page":"1481","DOI":"10.1016\/j.hrthm.2016.03.021","volume":"13","author":"A Colella","year":"2016","unstructured":"Colella A, Giaccardi M, Colella T, Modesti PA. Zero x-ray cardiac resynchronization therapy device implantation guided by a nonfluoroscopic mapping system: a pilot study. Heart Rhythm. 2016;13(7):1481\u20138.","journal-title":"Heart Rhythm"},{"issue":"40","key":"2579_CR12","doi-asserted-by":"publisher","first-page":"3997","DOI":"10.1093\/eurheartj\/ehac262","volume":"43","author":"K Zeppenfeld","year":"2022","unstructured":"Zeppenfeld K, Tfelt-Hansen J, de Riva M, Winkel BG, Behr ER, Blom NA, Charron P, Corrado D, Dagres N, de Chillou C, Eckardt L, Friede T, Haugaa KH, Hocini M, Lambiase PD, Marijon E, Merino JL, Peichl P, Priori SG, Reichlin T, Schulz-Menger J, Sticherling C, Tzeis S, Verstrael A, Volterrani M, ESC Scientific Document Group. 2022 ESC guidelines for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death. Eur Heart J. 2022;43(40):3997\u20134126.","journal-title":"Eur Heart J"},{"issue":"4","key":"2579_CR13","doi-asserted-by":"publisher","first-page":"252","DOI":"10.1016\/j.medin.2016.03.004","volume":"41","author":"S Aguiar Rosa","year":"2017","unstructured":"Aguiar Rosa S, Oliveira M, Valente B, Silva Cunha P, Almeida Morais L, Cruz Ferreira R. Ventricular electrical storm after acute myocardial infarction successfully treated with temporary atrial overdrive pacing. Med Intensiva. 2017;41(4):252\u20134.","journal-title":"Med Intensiva"},{"key":"2579_CR14","doi-asserted-by":"crossref","unstructured":"Dhir S, Gould GE. Complete atrioventricular block with Intact Retrograde Conduction in Cardiac Rhythm Management devices: implications of the Phenomenon.J Innov Card Rhythm Manag. 2019;10(4):3617\u20139.","DOI":"10.19102\/icrm.2019.100408"}],"container-title":["Journal of Cardiothoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13019-024-02579-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13019-024-02579-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13019-024-02579-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,6]],"date-time":"2024-02-06T03:04:18Z","timestamp":1707188658000},"score":1,"resource":{"primary":{"URL":"https:\/\/cardiothoracicsurgery.biomedcentral.com\/articles\/10.1186\/s13019-024-02579-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2,6]]},"references-count":14,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["2579"],"URL":"https:\/\/doi.org\/10.1186\/s13019-024-02579-0","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-1878053\/v1","asserted-by":"object"}]},"ISSN":["1749-8090"],"issn-type":[{"value":"1749-8090","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,2,6]]},"assertion":[{"value":"20 July 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 January 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 February 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Ethics approval was not sought as this report contains a single case report for which patient consent was obtained.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Written informed consent was obtained from the patient\u2019s next of kin for publication of this case report and any accompanying images. A copy of the written consent is available for review by the Editor-in-Chief of this journal.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"62"}}