{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,7,13]],"date-time":"2024-07-13T07:40:58Z","timestamp":1720856458384},"reference-count":6,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,7,13]],"date-time":"2024-07-13T00:00:00Z","timestamp":1720828800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,7,13]],"date-time":"2024-07-13T00:00:00Z","timestamp":1720828800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Research on the application value of left bundle branch pacing under the guidance of multi-parameter cardiac magnetic resonance technique","award":["202319"],"award-info":[{"award-number":["202319"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Cardiothorac Surg"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Lead dislodgements, tricuspid valve failure, and wound infections are prominent issues addressed by leadless pacemakers (LPM). These devises have emerged as viable alternatives to conventional transvenous pacemakers. LPMs offer minimized complications and effective pacing, particularly beneficial for elderly patients with a low body mass index (BMI) who are at heightened infection of risk. The Micra AV leadless pacemaker was released in the US in 2020, featuring a VDD pacing mode akin to conventional pacemakers. It senses atrial activity to pace ventricular beats while maintaining the natural atrioventricular activation sequence. Micra AV achieves atrioventricular synchronization through mechanical sensing principles. Ongoing research aims to assess its efficacy, implantation feasibility, and clinical safety.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Case presentation<\/jats:title>\n                <jats:p>An 83-year-old man with a history of syncope was the focus of this case study. An implantable cardiac monitor (ICM) recorded occasional high-degree atrioventricular block in the patient. Subsequently, the Micra AV was implanted via the left femoral vein, and its settings were adjusted in accordance with data obtained from the ICM. No significant issues regarding pacing threshold or impedance were found during the follow-up examinations post-surgery. Importantly, the patient experienced a noticeable reduction in symptoms compared to before the implantation.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Discussion<\/jats:title>\n                <jats:p>This case underscores the significance of ICM monitoring in elucidating cardiac events leading to syncope and guiding appropriate treatment. It also highlights the successful outcomes and reliable implantation of the Micra AV for managing high-degree atrioventricular block. This study contributes to the growing body of evidence supporting the adoption of leadless pacemakers as a viable option for patients requiring cardiac pacing, particularly those vulnerable to complications associated with traditional pacemakers. It provides real-world evidence of Micra AV\u2019s efficacy and safety, further validating its role in clinical practice.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s13019-024-02962-x","type":"journal-article","created":{"date-parts":[[2024,7,13]],"date-time":"2024-07-13T07:01:53Z","timestamp":1720854113000},"update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Implantable cardiac monitor and leadless pacemaker in the management of syncope due to intermittent high-degree atrioventricular block: a case report"],"prefix":"10.1186","volume":"19","author":[{"given":"Nian","family":"Tang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiaoxiao","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Denghong","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hongfei","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2024,7,13]]},"reference":[{"issue":"35","key":"2962_CR1","doi-asserted-by":"publisher","first-page":"3427","DOI":"10.1093\/eurheartj\/ehab364","volume":"42","author":"M Glikson","year":"2021","unstructured":"Glikson M, Nielsen JC, Kronborg MB, Michowitz Y, Auricchio A, Barbash IM, et al. 2021 ESC guidelines on cardiac pacing and cardiac resynchronization therapy. Eur Heart J. 2021;42(35):3427\u2013520.","journal-title":"Eur Heart J"},{"issue":"21","key":"2962_CR2","doi-asserted-by":"publisher","first-page":"1883","DOI":"10.1093\/eurheartj\/ehy037","volume":"39","author":"M Brignole","year":"2018","unstructured":"Brignole M, Moya A, de Lange FJ, Deharo JC, Elliott PM, Fanciulli A, et al. 2018 ESC guidelines for the diagnosis and management of syncope. Eur Heart J. 2018;39(21):1883\u2013948.","journal-title":"Eur Heart J"},{"issue":"16","key":"2962_CR3","doi-asserted-by":"publisher","first-page":"e025339","DOI":"10.1161\/JAHA.122.025339","volume":"11","author":"A Bodin","year":"2022","unstructured":"Bodin A, Clementy N, Bisson A, Pierre B, Herbert J, Babuty D, et al. Leadless or Conventional Transvenous Ventricular Permanent pacemakers: a Nationwide Matched Control Study. J Am Heart Assoc. 2022;11(16):e025339.","journal-title":"J Am Heart Assoc"},{"issue":"1","key":"2962_CR4","doi-asserted-by":"publisher","first-page":"94","DOI":"10.1016\/j.jacep.2019.10.017","volume":"6","author":"C Steinwender","year":"2020","unstructured":"Steinwender C, Khelae SK, Garweg C, Chan JYS, Ritter P, Johansen JB, et al. Atrioventricular synchronous pacing using a Leadless Ventricular Pacemaker: results from the MARVEL 2 study. JACC Clin Electrophysiol. 2020;6(1):94\u2013106.","journal-title":"JACC Clin Electrophysiol"},{"issue":"9","key":"2962_CR5","doi-asserted-by":"publisher","first-page":"1363","DOI":"10.1016\/j.hrthm.2018.05.004","volume":"15","author":"L Chinitz","year":"2018","unstructured":"Chinitz L, Ritter P, Khelae SK, Iacopino S, Garweg C, Grazia-Bongiorni M, et al. Accelerometer-based atrioventricular synchronous pacing with a ventricular leadless pacemaker: results from the Micra atrioventricular feasibility studies. Heart Rhythm. 2018;15(9):1363\u201371.","journal-title":"Heart Rhythm"},{"issue":"9","key":"2962_CR6","doi-asserted-by":"publisher","first-page":"1456","DOI":"10.1093\/europace\/euab083","volume":"23","author":"J Jelisejevas","year":"2021","unstructured":"Jelisejevas J, Breitenstein A, Hofer D, Winnik S, Steffel J, Saguner AM. Left femoral venous access for leadless pacemaker implantation: patient characteristics and outcomes. Europace. 2021;23(9):1456\u201361.","journal-title":"Europace"}],"container-title":["Journal of Cardiothoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13019-024-02962-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13019-024-02962-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13019-024-02962-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,7,13]],"date-time":"2024-07-13T07:03:03Z","timestamp":1720854183000},"score":1,"resource":{"primary":{"URL":"https:\/\/cardiothoracicsurgery.biomedcentral.com\/articles\/10.1186\/s13019-024-02962-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,7,13]]},"references-count":6,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["2962"],"URL":"https:\/\/doi.org\/10.1186\/s13019-024-02962-x","relation":{},"ISSN":["1749-8090"],"issn-type":[{"value":"1749-8090","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,7,13]]},"assertion":[{"value":"2 April 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 June 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 July 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The protocol was approved by the Clinical Research Ethics Committee of Chengdu Fifth People\u2019s Hospital with informed consent from patients and their families.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Written informed consent was obtained from the patient for publication of this case report and any accompanying images.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"443"}}