{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T02:38:41Z","timestamp":1787020721708,"version":"build-2736575974"},"reference-count":13,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,4,10]],"date-time":"2025-04-10T00:00:00Z","timestamp":1744243200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,4,10]],"date-time":"2025-04-10T00:00:00Z","timestamp":1744243200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Cardiothorac Surg"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Pulmonary valve failure requiring replacement (PVR) is more commonly seen in children and young adults with congenital heart disease (CHD). Adults with CHD and pulmonary regurgitation have traditionally undergone PVR with bioprosthetic valves. The inspiris resilia bovine pericardial valve is an FDA-approved bioprosthesis for the aortic position with encouraging data on 7-year outcomes. Previous reports on PVR using the Inspiris valve in young patients with CHD have demonstrated early failure of the valve. We report the early failure of this device in an elder patient with idiopathic pulmonary regurgitation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Case presentation<\/jats:title>\n                    <jats:p>The patient is a 69-year-old male with preoperative evaluation demonstrating idiopathic pulmonary valve regurgitation with moderately depressed right ventricular ejection fraction. The patient declined receiving a porcine valve, and therefore underwent PVR using the inspiris resilia (IR) valve due to known encouraging results when implanted in the aortic position in elder patients. A 27\u00a0mm IR valve was utilized, and intraoperative transesophageal echocardiography showed no regurgitation at the time of surgery. Surveillance echocardiography at 17\u00a0months, however, already demonstrated moderate to severe pulmonary prosthetic valve regurgitation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>This report highlights an early failure of the IR valve used for PVR in an elder patient with idiopathic pulmonary regurgitation. Data on the IR valve in the pulmonic position is limited to mostly small cohorts of young patients with CHD, and immediate outcomes are nearly universally satisfactory. However, recent reports in this specific population indicate early recurrence of regurgitation in the IR cohort compared to patients managed with a commercially available porcine aortic bioprosthetic valve, when used in the pulmonic position. Our reported case suggests that utilization of IR in the pulmonic position should be approached with caution in elderly patients as well.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s13019-025-03398-7","type":"journal-article","created":{"date-parts":[[2025,4,10]],"date-time":"2025-04-10T08:45:36Z","timestamp":1744274736000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Early inspiris resilia valve failure in a patient with idiopathic pulmonary valve regurgitation"],"prefix":"10.1186","volume":"20","author":[{"given":"Benjamin D.","family":"Seadler","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hannah K.","family":"Holland","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jutta","family":"Novalija","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefano","family":"Schena","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G. Hossein","family":"Almassi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,4,10]]},"reference":[{"issue":"5","key":"3398_CR1","doi-asserted-by":"publisher","first-page":"1333","DOI":"10.1016\/j.jtcvs.2016.06.064","volume":"152","author":"R Nomoto","year":"2016","unstructured":"Nomoto R, Sleeper LA, Borisuk MJ, et al. Outcome and performance of bioprosthetic pulmonary valve replacement in patients with congenital heart disease. J Thorac Cardiovasc Surg. 2016;152(5):1333-1342.e3.","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"3","key":"3398_CR2","doi-asserted-by":"publisher","first-page":"781","DOI":"10.1016\/j.jtcvs.2023.09.047","volume":"168","author":"T Beaver","year":"2023","unstructured":"Beaver T, Bavaria JE, Griffith B, et al. Seven-year outcomes following aortic valve replacement with a novel tissue bioprosthesis. J Thorac Cardiovasc Surg. 2024;168(3):781\u201391. https:\/\/doi.org\/10.1016\/j.jtcvs.2023.09.047.","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"4","key":"3398_CR3","doi-asserted-by":"publisher","first-page":"1000","DOI":"10.1016\/j.athoracsur.2022.09.026","volume":"115","author":"SM Said","year":"2023","unstructured":"Said SM, Hiremath G, Aggarwal V, et al. Early concerning outcomes for the Edwards Inspiris Resilia bioprosthesis in the pulmonary position. Ann Thorac Surg. 2023;115(4):1000\u20137.","journal-title":"Ann Thorac Surg"},{"issue":"1","key":"3398_CR4","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1080\/24748706.2020.1846826","volume":"5","author":"JM Arribas-Leal","year":"2021","unstructured":"Arribas-Leal JM, Garcia-Vieites M, Jimenez-Aceituna A, et al. Results of pulmonary valve replacement with a newly introduced bioprosthesis in children and young adults with congenital heart disease. Structural Heart. 2021;5(1):75\u20138.","journal-title":"Structural Heart"},{"issue":"2","key":"3398_CR5","doi-asserted-by":"publisher","first-page":"345","DOI":"10.1016\/j.jtcvs.2020.06.157","volume":"161","author":"CW Baird","year":"2021","unstructured":"Baird CW, Ch\u00e1vez M, Sleeper LA, et al. Reintervention rates after bioprosthetic pulmonary valve replacement in patients younger than 30 years of age: a multicenter analysis. J Thorac Cardiovasc Surg. 2021;161(2):345-362.e2.","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"19","key":"3398_CR6","doi-asserted-by":"publisher","DOI":"10.1161\/JAHA.120.018506","volume":"9","author":"AE Kostyunin","year":"2020","unstructured":"Kostyunin AE, Yuzhalin AE, Rezvova MA, Ovcharenko EA, Glushkova TV, Kutikhin AG. Degeneration of bioprosthetic heart valves: update 2020. J Am Heart Assoc. 2020;9(19): e018506.","journal-title":"J Am Heart Assoc"},{"issue":"1","key":"3398_CR7","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1177\/21501351231178750","volume":"15","author":"A Sengupta","year":"2024","unstructured":"Sengupta A, Pastuszko P, Zaidi AN, et al. Early outcomes of pulmonary valve replacement with the Edwards Inspiris Resilia pericardial bioprosthesis. World J Pediatr Congenit Heart Surg. 2024;15(1):52\u20139.","journal-title":"World J Pediatr Congenit Heart Surg"},{"issue":"6","key":"3398_CR8","doi-asserted-by":"publisher","first-page":"1203","DOI":"10.1016\/j.athoracsur.2023.07.049","volume":"117","author":"DK Ragheb","year":"2024","unstructured":"Ragheb DK, Martin E, Jaggi A, et al. Short- and mid-term results of pulmonary valve replacement with the inspiris valve. Ann Thorac Surg. 2024;117(6):1203\u201310.","journal-title":"Ann Thorac Surg"},{"issue":"4","key":"3398_CR9","doi-asserted-by":"publisher","first-page":"1210","DOI":"10.1016\/j.jtcvs.2023.04.018","volume":"166","author":"SN Nguyen","year":"2023","unstructured":"Nguyen SN, Vinogradsky AV, Sevensky R, et al. Use of the inspiris valve in the native right ventricular outflow tract is associated with early prosthetic regurgitation. J Thorac Cardiovasc Surg. 2023;166(4):1210-1221.e8.","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"3","key":"3398_CR10","doi-asserted-by":"publisher","first-page":"641","DOI":"10.1016\/j.athoracsur.2021.12.025","volume":"115","author":"PM Patel","year":"2023","unstructured":"Patel PM, Zapata D, Qu W, et al. Bioprosthetic pulmonary valve dysfunction in congenital heart disease. Ann Thorac Surg. 2023;115(3):641\u20138.","journal-title":"Ann Thorac Surg"},{"issue":"6","key":"3398_CR11","doi-asserted-by":"publisher","first-page":"1211","DOI":"10.1016\/j.athoracsur.2023.09.030","volume":"117","author":"RH MacIver","year":"2024","unstructured":"MacIver RH, Overman DM. Inspiris Resilia valve in the pulmonary position: modify or abandon? Ann Thorac Surg. 2024;117(6):1211.","journal-title":"Ann Thorac Surg"},{"issue":"6","key":"3398_CR12","doi-asserted-by":"publisher","first-page":"e170","DOI":"10.1016\/j.jtcvs.2024.01.036","volume":"167","author":"F Shikata","year":"2024","unstructured":"Shikata F, Miyaji K. The use of Inspiris Resilia valves in the pulmonary position for repaired congenital heart defects. J Thorac Cardiovasc Surg. 2024;167(6):e170\u20131.","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"6","key":"3398_CR13","doi-asserted-by":"publisher","first-page":"e171","DOI":"10.1016\/j.jtcvs.2024.03.004","volume":"167","author":"SN Nguyen","year":"2024","unstructured":"Nguyen SN, Vinogradsky AV, Bacha EA, Goldstone AB. Reply from authors: inspiris durability in the pulmonic position: age may matter, but more than for other valves? J Thorac Cardiovasc Surg. 2024;167(6):e171\u20134.","journal-title":"J Thorac Cardiovasc Surg"}],"container-title":["Journal of Cardiothoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13019-025-03398-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13019-025-03398-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13019-025-03398-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,10]],"date-time":"2025-04-10T08:45:36Z","timestamp":1744274736000},"score":1,"resource":{"primary":{"URL":"https:\/\/cardiothoracicsurgery.biomedcentral.com\/articles\/10.1186\/s13019-025-03398-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,10]]},"references-count":13,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["3398"],"URL":"https:\/\/doi.org\/10.1186\/s13019-025-03398-7","relation":{},"ISSN":["1749-8090"],"issn-type":[{"value":"1749-8090","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4,10]]},"assertion":[{"value":"6 November 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 March 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 April 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"Ethics approval was waived in the setting of a case report detailing retrospective review of the clinical course of a single patient who provided written consent for publication.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Written informed consent was obtained for this publication.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}}],"article-number":"183"}}