{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,20]],"date-time":"2026-06-20T15:21:08Z","timestamp":1781968868835,"version":"3.54.5"},"reference-count":13,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,12,2]],"date-time":"2025-12-02T00:00:00Z","timestamp":1764633600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,1,6]],"date-time":"2026-01-06T00:00:00Z","timestamp":1767657600000},"content-version":"vor","delay-in-days":35,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Cardiothorac Surg"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Competitive flow (CF) in coronary artery bypass grafting (CABG) occurs when graft flow is impaired due to higher competing flow from either the native circulation or another graft and may result in functional graft occlusion. We report a case of functional graft occlusion of a left internal mammary artery (LIMA) due to flow competition with a saphenous vein graft (SVG) and discuss the rationale of ligating the graft responsible for the CF.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Case presentation<\/jats:title>\n                    <jats:p>The case refers to a 56-year-old man with an isolated subtotal ostial left anterior descending (LAD) lesion who underwent conventional double on-pump CABG with an in situ (LIMA) to the LAD and a centrally anastomosed SVG to the Diagonal branch (D1). Concerning the initial Transit-time flow measurements (TTFM), the SVG had a mean graft flow (MGF) of 49\u00a0ml\/min, a Pulsatility index (PI) of 1 and a Diastolic flow (DF) of 66%. The LIMA graft had an MGF of 31\u00a0ml\/minute, a PI of 3.8, a DF of 80%, but a Backward flow (BF) of 8%. As the LIMA BF was quite high, we suspected competitive flow of the graft and thus decided to transiently apply a bulldog clamp to the SVG, to check if the LIMA TTFM would change. Indeed, MGF was 44\u00a0ml\/minute, the PI was 2.3, DF was 60%, and BF was 0.9%. Despite these results, the operating surgeon did not alter the revascularization plan and the operation was finished. The patient was discharged uneventfully. However, in a 6-month follow-up, the patient was symptomatic and with poor ejection fraction, and the diagnostic work-up revealed the functional occlusion of the LIMA graft with a string sign, and a patent SVG. After Heart Team consultation and patient update, he underwent left main stent implantation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>There should be a great degree of suspicion for CF with high BF values, even when the rest of the parameters measured during TTFM are normal or marginal. Also, the location of the LAD stenosis proximal to the D1 is a risk factor for CF when both arteries are grafted. Changing the revascularization plan based on TTFM is warranted for optimal outcomes.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s13019-025-03529-0","type":"journal-article","created":{"date-parts":[[2025,12,2]],"date-time":"2025-12-02T17:16:28Z","timestamp":1764695788000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Should we ligate coronary conduits when flow measurements indicate competitive flow? a case report"],"prefix":"10.1186","volume":"21","author":[{"given":"Konstantinos","family":"Papakonstantinou","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Panagiotis","family":"Lerios","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mihalis","family":"Argiriou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vasilios","family":"Patris","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ilias","family":"Gissis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John","family":"Kokotsakis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Panagiotis","family":"Dedeilias","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Periklis","family":"Tomos","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,12,2]]},"reference":[{"issue":"6","key":"3529_CR1","doi-asserted-by":"publisher","first-page":"1622","DOI":"10.1016\/j.jtcvs.2015.02.050","volume":"149","author":"K Honda","year":"2015","unstructured":"Honda K, Okamura Y, Nishimura Y, Uchita S, Yuzaki M, Kaneko M, et al. Graft flow assessment using a transit time flow meter in fractional flow reserve-guided coronary artery bypass surgery. J Thorac Cardiovasc Surg. 2015;149(6):1622\u20138.","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"3","key":"3529_CR2","doi-asserted-by":"publisher","first-page":"468","DOI":"10.1016\/j.jtcvs.2006.02.014","volume":"132","author":"G Di Giammarco","year":"2006","unstructured":"Di Giammarco G, Pano M, Cirmeni S, Pelini P, Vitolla G, Di Mauro M. Predictive value of intraoperative transit-time flow measurement for short-term graft patency in coronary surgery. J Thorac Cardiovasc Surg. 2006;132(3):468\u201374.","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"1","key":"3529_CR3","doi-asserted-by":"publisher","first-page":"223","DOI":"10.1186\/1752-1947-7-223","volume":"7","author":"JJ Gagnier","year":"2013","unstructured":"Gagnier JJ, Kienle G, Altman DG, Moher D, Sox H, Riley D, et al. The CARE guidelines: consensus-based clinical case reporting guideline development. J Med Case Rep. 2013;7(1):223.","journal-title":"J Med Case Rep"},{"issue":"2","key":"3529_CR4","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1161\/CIRCULATIONAHA.115.015549","volume":"133","author":"RE Harskamp","year":"2016","unstructured":"Harskamp RE, Alexander JH, Ferguson TB Jr., Hager R, Mack MJ, Englum B, et al. Frequency and predictors of internal mammary artery graft failure and subsequent clinical outcomes: insights from the project of Ex-vivo vein graft engineering via transfection (PREVENT) IV trial. Circulation. 2016;133(2):131\u20138.","journal-title":"Circulation"},{"issue":"4","key":"3529_CR5","doi-asserted-by":"publisher","first-page":"833","DOI":"10.1016\/j.ejcts.2008.07.011","volume":"34","author":"M Kawamura","year":"2008","unstructured":"Kawamura M, Nakajima H, Kobayashi J, Funatsu T, Otsuka Y, Yagihara T, et al. Patency rate of the internal thoracic artery to the left anterior descending artery bypass is reduced by competitive flow from the concomitant saphenous vein graft in the left coronary artery. Eur J Cardiothorac Surg. 2008;34(4):833\u20138.","journal-title":"Eur J Cardiothorac Surg"},{"issue":"2","key":"3529_CR6","doi-asserted-by":"publisher","first-page":"481","DOI":"10.1016\/j.athoracsur.2004.03.003","volume":"78","author":"H Nakajima","year":"2004","unstructured":"Nakajima H, Kobayashi J, Tagusari O, Bando K, Niwaya K, Kitamura S. Competitive flow in arterial composite grafts and effect of graft arrangement in Off-Pump coronary revascularization. Ann Thorac Surg. 2004;78(2):481\u20136.","journal-title":"Ann Thorac Surg"},{"issue":"2","key":"3529_CR7","doi-asserted-by":"publisher","first-page":"305","DOI":"10.1111\/jocs.16103","volume":"37","author":"FR Halfwerk","year":"2022","unstructured":"Halfwerk FR, Spoor P, Mariani S, Hagmeijer R, Grandjean JG. Intraoperative transit time flow measurements during off-pump coronary artery bypass surgery: the impact of coronary stenosis on competitive flow. J Card Surg. 2022;37(2):305\u201313.","journal-title":"J Card Surg"},{"issue":"3","key":"3529_CR8","doi-asserted-by":"publisher","first-page":"589","DOI":"10.1016\/j.athoracsur.2024.05.026","volume":"118","author":"Y Kang","year":"2024","unstructured":"Kang Y, Kim JS, Sohn SH, Hwang HY. Competitive flow of terminal anastomosis to right coronary territory in Y coronary artery bypass. Ann Thorac Surg. 2024;118(3):589\u201395.","journal-title":"Ann Thorac Surg"},{"key":"3529_CR9","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1016\/j.xjtc.2020.12.040","volume":"7","author":"R Akhrass","year":"2021","unstructured":"Akhrass R, Bakaeen FG. Intraoperative graft patency validation: friend or foe? JTCVS Techniques. 2021;7:131\u20137.","journal-title":"JTCVS Techniques"},{"key":"3529_CR10","doi-asserted-by":"publisher","first-page":"116","DOI":"10.1016\/j.xjon.2022.06.006","volume":"11","author":"JS Kim","year":"2022","unstructured":"Kim JS, Kang Y, Sohn SH, Hwang HY. Occurrence rate and fate of competitive flow of the left internal thoracic artery used in Y-composite grafts. JTCVS Open. 2022;11:116\u201326.","journal-title":"JTCVS Open"},{"issue":"1","key":"3529_CR11","doi-asserted-by":"publisher","first-page":"50","DOI":"10.4103\/heartviews.heartviews_38_23","volume":"25","author":"S Kumar","year":"2024","unstructured":"Kumar S, Pandey P. Internal mammary artery-saphenous vein Y anastomosis in coronary artery bypass Grafting - Is there a possibility of coronary steal?? Heart Views. 2024;25(1):50\u20131.","journal-title":"Heart Views"},{"issue":"6","key":"3529_CR12","doi-asserted-by":"publisher","first-page":"620","DOI":"10.1097\/HCO.0b013e3283583000","volume":"27","author":"D Glineur","year":"2012","unstructured":"Glineur D, Hanet C. Competitive flow in coronary bypass surgery: is it a problem? Curr Opin Cardiol. 2012;27(6):620\u20138.","journal-title":"Curr Opin Cardiol"},{"issue":"14","key":"3529_CR13","doi-asserted-by":"publisher","first-page":"1160","DOI":"10.1161\/CIRCULATIONAHA.121.054311","volume":"144","author":"M Gaudino","year":"2021","unstructured":"Gaudino M, Sandner S, Giammarco GD, Franco AD, Arai H, Asai T, et al. The use of intraoperative transit time flow measurement for coronary artery bypass surgery: systematic review of the evidence and expert opinion statements. Circulation. 2021;144(14):1160\u201371.","journal-title":"Circulation"}],"container-title":["Journal of Cardiothoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13019-025-03529-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13019-025-03529-0","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13019-025-03529-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,6]],"date-time":"2026-01-06T14:54:30Z","timestamp":1767711270000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s13019-025-03529-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,2]]},"references-count":13,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["3529"],"URL":"https:\/\/doi.org\/10.1186\/s13019-025-03529-0","relation":{},"ISSN":["1749-8090"],"issn-type":[{"value":"1749-8090","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,12,2]]},"assertion":[{"value":"31 December 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 July 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 December 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Institutional approval was waived to publish the case details due to local regulation. Patient informed consent was obtained.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Obtained.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"12"}}